Comparison of measured and estimated maximum skin doses during CT fluoroscopy lung biopsies.

Abstract:

PURPOSE:To measure patient-specific maximum skin dose (MSD) associated with CT fluoroscopy (CTF) lung biopsies and to compare measured MSD with the MSD estimated from phantom measurements, as well as with the CTDIvol of patient examinations. METHODS:Data from 50 patients with lung lesions who underwent a CT fluoroscopy-guided biopsy were collected. The CT protocol consisted of a low-kilovoltage (80 kV) protocol used in combination with an algorithm for dose reduction to the radiology staff during the interventional procedure, HandCare (HC). MSD was assessed during each intervention using EBT2 gafchromic films positioned on patient skin. Lesion size, position, total fluoroscopy time, and patient-effective diameter were registered for each patient. Dose rates were also estimated at the surface of a normal-size anthropomorphic thorax phantom using a 10 cm pencil ionization chamber placed at every 30°, for a full rotation, with and without HC. Measured MSD was compared with MSD values estimated from the phantom measurements and with the cumulative CTDIvol of the procedure. RESULTS:The median measured MSD was 141 mGy (range 38-410 mGy) while the median cumulative CTDIvol was 72 mGy (range 24-262 mGy). The ratio between the MSD estimated from phantom measurements and the measured MSD was 0.87 (range 0.12-4.1) on average. In 72% of cases the estimated MSD underestimated the measured MSD, while in 28% of the cases it overestimated it. The same trend was observed for the ratio of cumulative CTDIvol and measured MSD. No trend was observed as a function of patient size. CONCLUSIONS:On average, estimated MSD from dose rate measurements on phantom as well as from CTDIvol of patient examinations underestimates the measured value of MSD. This can be attributed to deviations of the patient's body habitus from the standard phantom size and to patient positioning in the gantry during the procedure.

journal_name

Med Phys

journal_title

Medical physics

authors

Zanca F,Jacobs A,Crijns W,De Wever W

doi

10.1118/1.4884231

subject

Has Abstract

pub_date

2014-07-01 00:00:00

pages

073901

issue

7

eissn

0094-2405

issn

2473-4209

journal_volume

41

pub_type

杂志文章
  • Penumbral measurements in water for high-energy x rays.

    abstract::Ionization chambers of varying inside diameter have been used to investigate the penumbral region of 60Co, 6-MV, and 31-MV x-ray beams. Measurements were made in water at varying depths up to 25 cm for a square field of side length 10 cm. The dependence of the penumbral widths on both the inside diameter of the ioniza...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595963

    authors: Dawson DJ,Schroeder NJ,Hoya JD

    更新日期:1986-01-01 00:00:00

  • Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee.

    abstract::A comprehensive performance testing program is an essential ingredient of high-quality single-photon emission computed tomography (SPECT). Many of the procedures previously published are complicated, time consuming, or require a special testing environment. This Task Group developed a protocol for evaluating SPECT ima...

    journal_title:Medical physics

    pub_type: 指南,杂志文章

    doi:10.1118/1.597605

    authors: Graham LS,Fahey FH,Madsen MT,van Aswegen A,Yester MV

    更新日期:1995-04-01 00:00:00

  • Technical note: An algorithm to calculate the tissue phantom ratio from depth dose in radiosurgery.

    abstract:PURPOSE:To propose a method to calculate the tissue phantom ratio (TPR) using the depth dose and to compare the proposed method with two other methods. METHODS:An analytical dose model from Bjärngard was used to describe the depth dose and the TPR. The parameters of the model were derived from depth dose measurements,...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3570575

    authors: Ramos Garcia LI,Almansa JF

    更新日期:2011-05-01 00:00:00

  • Development of a Monte Carlo multiple source model for inclusion in a dose calculation auditing tool.

    abstract:PURPOSE:The Imaging and Radiation Oncology Core Houston (IROC-H) (formerly the Radiological Physics Center) has reported varying levels of agreement in their anthropomorphic phantom audits. There is reason to believe one source of error in this observed disagreement is the accuracy of the dose calculation algorithms an...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12426

    authors: Faught AM,Davidson SE,Fontenot J,Kry SF,Etzel C,Ibbott GS,Followill DS

    更新日期:2017-09-01 00:00:00

  • Evaluating IMRT and VMAT dose accuracy: practical examples of failure to detect systematic errors when applying a commonly used metric and action levels.

    abstract:PURPOSE:This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detai...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4826166

    authors: Nelms BE,Chan MF,Jarry G,Lemire M,Lowden J,Hampton C,Feygelman V

    更新日期:2013-11-01 00:00:00

  • Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo-based MRI.

    abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12318

    authors: Fatnassi C,Boucenna R,Zaidi H

    更新日期:2017-07-01 00:00:00

  • Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation.

    abstract::A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2776255

    authors: Lu HM,Brett R,Engelsman M,Slopsema R,Kooy H,Flanz J

    更新日期:2007-10-01 00:00:00

  • Modification of the University of Washington Neutron Radiotherapy Facility for optimization of neutron capture enhanced fast-neutron therapy.

    abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598839

    authors: Nigg DW,Wemple CA,Risler R,Hartwell JK,Harker YD,Laramore GE

    更新日期:2000-02-01 00:00:00

  • Investigation of intensity-modulated radiotherapy optimization with gEUD-based objectives by means of simulated annealing.

    abstract::Inverse treatment planning of intensity-modulated radiation therapy (IMRT) is complicated by several sources of error, which can cause deviations of optimized plans from the true optimal solution. These errors include the systematic and convergence error, the local minima error, and the optimizer convergence error. We...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2896070

    authors: Hartmann M,Bogner L

    更新日期:2008-05-01 00:00:00

  • The prediction of breast cancer biopsy outcomes using two CAD approaches that both emphasize an intelligible decision process.

    abstract::Mammography is the most effective method for breast cancer screening available today. However, the low positive predictive value of breast biopsy resulting from mammogram interpretation leads to approximately 70% unnecessary biopsies with benign outcomes. To reduce the high number of unnecessary breast biopsies, sever...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2786864

    authors: Elter M,Schulz-Wendtland R,Wittenberg T

    更新日期:2007-11-01 00:00:00

  • Study of the secondary neutral radiation in proton therapy: toward an indirect in vivo dosimetry.

    abstract:PURPOSE:Secondary particles produced in the collision of protons with beam modifiers are of concern in proton therapy. Nevertheless, secondary radiation can provide information on the dosimetric parameters through its dependency on the modulating accessories (range shifter and range modulating wheel). Relatively little...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4765049

    authors: Carnicer A,Letellier V,Rucka G,Angellier G,Sauerwein W,Herault J

    更新日期:2012-12-01 00:00:00

  • Characterization of statistical prior image constrained compressed sensing (PICCS): II. Application to dose reduction.

    abstract:PURPOSE:The ionizing radiation imparted to patients during computed tomography exams is raising concerns. This paper studies the performance of a scheme called dose reduction using prior image constrained compressed sensing (DR-PICCS). The purpose of this study is to characterize the effects of a statistical model of x...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773866

    authors: Lauzier PT,Chen GH

    更新日期:2013-02-01 00:00:00

  • Sinusoidal modulation analysis for optical system MTF measurements.

    abstract::The modulation transfer function (MTF) is a commonly used metric for defining the spatial resolution characteristics of imaging systems. While the MTF is defined in terms of how an imaging system demodulates the amplitude of a sinusoidal input, this approach has not been in general use to measure MTFs in the medical i...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597840

    authors: Boone JM,Yu T,Seibert JA

    更新日期:1996-12-01 00:00:00

  • Rotationally resliced 3D prostate TRUS segmentation using convex optimization with shape priors.

    abstract:PURPOSE:Efficient and accurate segmentations of 3D end-firing transrectal ultrasound (TRUS) images play an important role in planning of 3D TRUS guided prostate biopsy. However, poor image quality of the input 3D TRUS images, such as strong imaging artifacts and speckles, often makes it a challenging task to extract th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4906129

    authors: Qiu W,Yuan J,Ukwatta E,Fenster A

    更新日期:2015-02-01 00:00:00

  • SU-E-T-126: Non-Reference Condition Correction Factor KNR of Typical Radiation Detectors for the Dosimetry of High-Energy Photons.

    abstract:PURPOSE:To correct for the deviations of the detector response when typical radiation detectors are used under non-reference conditions, factor kNR was calculated from the known energy dependence of the detector response at photon energies from 10 keV upwards and from clinical photon spectra within a large water phanto...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735184

    authors: Chofor N,Poppe B,Harder D

    更新日期:2012-06-01 00:00:00

  • Characterization and identification of spatial artifacts during 4D-CT imaging.

    abstract:PURPOSE:The purpose of this work is twofold: First, to characterize the artifacts occurring in helical 4D-CT imaging; second, to propose a method that can automatically identify the artifacts in 4D-CT images. The authors have designed a process that can automatically identify the artifacts in 4D-CT images, which may be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3553556

    authors: Han D,Bayouth J,Bhatia S,Sonka M,Wu X

    更新日期:2011-04-01 00:00:00

  • Accurate assessment and prediction of noise in clinical CT images.

    abstract:PURPOSE:The objectives of this study were (a) to devise a technique for measuring quantum noise in clinical body computed tomography (CT) images and (b) to develop a model for predicting that noise with high accuracy. METHODS:The study included 83 clinical image sets at two dose levels (clinical and 50% reduced dose l...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4938588

    authors: Tian X,Samei E

    更新日期:2016-01-01 00:00:00

  • Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning.

    abstract::The Monte Carlo (MC) method has been shown through many research studies to calculate accurate dose distributions for clinical radiotherapy, particularly in heterogeneous patient tissues where the effects of electron transport cannot be accurately handled with conventional, deterministic dose algorithms. Despite its p...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2795842

    authors: Chetty IJ,Curran B,Cygler JE,DeMarco JJ,Ezzell G,Faddegon BA,Kawrakow I,Keall PJ,Liu H,Ma CM,Rogers DW,Seuntjens J,Sheikh-Bagheri D,Siebers JV

    更新日期:2007-12-01 00:00:00

  • Measured and calculated K-fluorescence effects on the MTF of an amorphous-selenium based CCD x-ray detector.

    abstract:PURPOSE:Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3673957

    authors: Hunter DM,Belev G,Kasap S,Yaffe MJ

    更新日期:2012-02-01 00:00:00

  • Cascaded systems analysis of noise reduction algorithms in dual-energy imaging.

    abstract::An important aspect of dual-energy (DE) x-ray image decomposition is the incorporation of noise reduction techniques to mitigate the amplification of quantum noise. This article extends cascaded systems analysis of imaging performance to DE imaging systems incorporating linear noise reduction algorithms. A general ana...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2826556

    authors: Richard S,Siewerdsen JH

    更新日期:2008-02-01 00:00:00

  • Prostatome: a combined anatomical and disease based MRI atlas of the prostate.

    abstract:PURPOSE:In this work, the authors introduce a novel framework, the anatomically constrained registration (AnCoR) scheme and apply it to create a fused anatomic-disease atlas of the prostate which the authors refer to as the prostatome. The prostatome combines a MRI based anatomic and a histology based disease atlas. St...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4881515

    authors: Rusu M,Bloch BN,Jaffe CC,Genega EM,Lenkinski RE,Rofsky NM,Feleppa E,Madabhushi A

    更新日期:2014-07-01 00:00:00

  • Spectrally resolved bioluminescence tomography using the reciprocity approach.

    abstract::Spectrally resolved bioluminescence optical tomography is an approach to recover images of, for example, Luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminesc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982138

    authors: Dehghani H,Davis SC,Pogue BW

    更新日期:2008-11-01 00:00:00

  • On charged particle equilibrium violation in external photon fields.

    abstract:PURPOSE:In a recent paper by Bouchard et al. [Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al. [Med. Phys. 3...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3684952

    authors: Bouchard H,Seuntjens J,Palmans H

    更新日期:2012-03-01 00:00:00

  • Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT).

    abstract:PURPOSE:The number of pencil beam scanned proton therapy (PBS-PT) facilities equipped with cone-beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS-PT treatments of thoracic tumors, we assess the performance of Motion-Aware Re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14521

    authors: den Otter LA,Chen K,Janssens G,Meijers A,Both S,Langendijk JA,Rosen LR,Wu HT,Knopf AC

    更新日期:2020-12-01 00:00:00

  • A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery.

    abstract::The trend toward conformal techniques in stereotactic radiosurgery necessitates an accurate and practical method for verification of irregular three-dimensional dose distributions. This work presents the design and evaluation of a phantom system facilitating the measurement of conformal dose distributions using one or...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598962

    authors: Robar JL,Clark BG

    更新日期:2000-05-01 00:00:00

  • Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung.

    abstract:PURPOSE:Target localization accuracy of cone-beam CT (CBCT) images used in radiation treatment of respiratory disease sites is affected by motion artifacts (blurring and streaking). The authors have previously reported on a method of respiratory motion correction in thoracic CBCT at end expiration (EE). The previous re...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4896101

    authors: Dzyubak O,Kincaid R,Hertanto A,Hu YC,Pham H,Rimner A,Yorke E,Zhang Q,Mageras GS

    更新日期:2014-10-01 00:00:00

  • Three-dimensional reconstruction of vascular trees. Theory and methodology.

    abstract::In this paper we examine the few-view reconstruction problem as it applies to imaging vascular trees. A fully automated reconstruction algorithm is described that circumvents the traditional "correspondence problem," using only notions of consistency and connectivity. It is assumed that the vascular tree is a connecte...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597704

    authors: Henri CJ,Peters TM

    更新日期:1996-02-01 00:00:00

  • SU-E-T-178: Optically Stimulated Luminescence (OSL) Dosimetry: A Study of A-Al2O3:C Assessed by PENELOPE Monte Carlo Simulation.

    abstract:PURPOSE:To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. METHODS:Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735237

    authors: Nicolucci P,Schuch F

    更新日期:2012-06-01 00:00:00

  • The enhancement of radiotherapy verification images by an automated edge detection technique.

    abstract::Adaptive histogram equalization techniques are known to be effective for the enhancement of contrast in portal images acquired during radiotherapy treatments. A significant drawback is the loss of definition on the edges of the treatment field. Analysis of this problem shows that it can be remedied by separating the t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596807

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1992-05-01 00:00:00

  • Evaluation of the microangiographic fluoroscope (MAF) using generalized system performance metrics.

    abstract:PURPOSE:The performance of a newly developed, high resolution, microangiographic fluoroscope (MAF) (35 μm pixel pitch and 300 μm thick CsI phosphor) was evaluated using a generalized linear system analysis and compared with that of a standard amorphous Si thin film transistor flat panel detector (FPD) (194 μm pixel pit...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4792460

    authors: Jain A,Bednarek DR,Rudin S

    更新日期:2013-03-01 00:00:00