Free-focus radiography using conventional films--radiation exposures in a simulated clinical study.

Abstract:

:This study compared air exposures during conventional dental and maxillofacial radiography and similar views using free-focus radiography with conventional image receptors. The results show that periapical type surveys on nonscreen film placed extraorally or in the buccal fold may be carried out with an exposure to the surface tissues, which is similar to or less than conventional dental radiography. Extraoral survey type radiographs of the jaws may be carried out with significantly less surface exposure than lateral oblique views of the jaws. The least exposure was required, when the film was placed in the buccla fold instead of against the face during free-focus radiography. The exposures with film screen combinations were reduced by an order of magnitude when compared to the nonscreen techniques. Proper filtration of the beam of the miniaturized x-ray machines radiography in dentistry may thus be desirable and applications in other parts of the body encouraged.

journal_name

Med Phys

journal_title

Medical physics

authors

Jensen TW,Randall GJ,Goldberg AJ

doi

10.1118/1.594690

subject

Has Abstract

pub_date

1980-07-01 00:00:00

pages

341-7

issue

4

eissn

0094-2405

issn

2473-4209

journal_volume

7

pub_type

杂志文章
  • Neutron and gamma spectroscopy for clinical dosimetry.

    abstract::Neutron and photon energy spectra were measured in different depths and lateral positions in tissue-equivalent phantoms exposed to a therapeutical 14.1 MeV neutron beam. Intensity weighted mass energy absorption coefficients were derived for application in ionization chamber dosimetry in mixed neutron-gamma fields. Th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594744

    authors: Schmidt R,Magiera E,Scobel W

    更新日期:1980-09-01 00:00:00

  • General strategy for the protection of organs at risk in IMRT therapy of a moving body.

    abstract::We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it po...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3132305

    authors: Abolfath RM,Papiez L

    更新日期:2009-07-01 00:00:00

  • The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy.

    abstract::Methods for scatter dose calculations in brachytherapy have been developed based on the collapsed cone superposition algorithm. The methods account for effects on the scatter dose caused by the three-dimensional distribution of heterogeneities in the irradiated volume and are considerably faster than methods based on ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1290485

    authors: Carlsson AK,Ahnesjö A

    更新日期:2000-10-01 00:00:00

  • SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.

    abstract:PURPOSE:To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. METHODS:Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735153

    authors: Chiu-Tsao S,Massillon-Jl G,Domingo-Muñoz I,Chan M

    更新日期:2012-06-01 00:00:00

  • Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume.

    abstract::The assessment of the radiation dose to internal organs or to an embryo or fetus is required on occasion for risk assessment or for comparing imaging studies. Limited resources hinder the ability to accurately assess the radiation dose received to locations outside the tissue volume actually scanned during computed to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1312809

    authors: Boone JM,Cooper VN 3rd,Nemzek WR,McGahan JP,Seibert JA

    更新日期:2000-10-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Electron dose calculation using multiple-scattering theory. A. Gaussian multiple-scattering theory.

    abstract::This article is the first in a series on the calculation of electron dose using multiple-scattering theory. In it we develop a unified theory, which we term Gaussian multiple-scattering theory, starting from a number of contributions already in the literature: the Fermi-Eyges multiple-scattering theory, the Yang path ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596166

    authors: Jette D

    更新日期:1988-03-01 00:00:00

  • Sci-Sat AM(1): Imaging-04: Respiratory errors in cardiac PET/CT with manual alignment of the CT image.

    abstract::Respiratory motion can produce misregistration errors between CT and PET images in cardiac PET/CT imaging. The objective of this study was to determine if manual registration of a single-phase end-expiration CT scan to the PET image would eliminate respiratory-induced artifacts. Listmode data from 71 cardiac PET patie...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2965988

    authors: Wells RG

    更新日期:2008-07-01 00:00:00

  • Study of dosimetry consistency for kilovoltage x-ray beams.

    abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598448

    authors: Ma CM,Li XA,Seuntjens JP

    更新日期:1998-12-01 00:00:00

  • SU-E-J-81: Beveled Needle Tip Detection Error in Ultrasound-Guided Prostate Brachytherapy.

    abstract:PURPOSE:To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. METHODS:Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Cov...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734916

    authors: Leu S,Ruiz B,Podder T

    更新日期:2012-06-01 00:00:00

  • Feasibility of a simple method of hybrid collimation for megavoltage grid therapy.

    abstract:PURPOSE:Megavoltage grid therapy is currently delivered with step-and-shoot multisegment techniques or using a high attenuation block with divergent holes. However, the commercial availability of grid blocks is limited, their construction is difficult, and step-and-shoot techniques require longer treatment times and ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4801902

    authors: Almendral P,Mancha PJ,Roberto D

    更新日期:2013-05-01 00:00:00

  • Technical Note: Virtual phantom analyses for preprocessing evaluation and detection of a robust feature set for MRI-radiomics of the brain.

    abstract:PURPOSE:The purpose of the paper was to use a virtual phantom to identify a set of radiomic features from T1-weighted and T2-weighted magnetic resonance imaging (MRI) of the brain which is stable to variations in image acquisition parameters and to evaluate the effect of image preprocessing on radiomic features stabili...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13834

    authors: Bologna M,Corino V,Mainardi L

    更新日期:2019-11-01 00:00:00

  • Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation.

    abstract:PURPOSE:Intensity modulated proton therapy (IMPT) of head and neck (H&N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4908223

    authors: Landry G,Nijhuis R,Dedes G,Handrack J,Thieke C,Janssens G,Orban de Xivry J,Reiner M,Kamp F,Wilkens JJ,Paganelli C,Riboldi M,Baroni G,Ganswindt U,Belka C,Parodi K

    更新日期:2015-03-01 00:00:00

  • Comments on "Sampling techniques for the evaluation of treatment plans" [Med. Phys. 20, 151-161 (1993)].

    abstract::We believe that, for the purpose of evaluation and optimization of treatment plans, quasirandom sampling is superior to grid sampling and should be the method of choice. We believe it to be on average more efficient than grid sampling (i.e., more accurate for any given number of dose estimates) and, even more importan...

    journal_title:Medical physics

    pub_type: 评论,信件

    doi:10.1118/1.597103

    authors: Niemierko A,Goitein M

    更新日期:1993-09-01 00:00:00

  • A comparative contrast-detail study of five medical displays.

    abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2868780

    authors: Samei E,Ranger NT,Delong DM

    更新日期:2008-04-01 00:00:00

  • An accelerator based system for in vivo neutron activation analysis measurements of manganese in human hand bones.

    abstract::Manganese (Mn) is an essential nutrient for growth and development. Unfortunately, overexposure can lead to neurological damage, which is manifested as a movement disorder marked by tremors. Preclinical symptoms have been found in populations occupationally exposed to the element, and it is suggested that in late stag...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1517613

    authors: Arnold ML,McNeill FE,Stronach IM,Pejovic-Milic A,Chettle DR,Waker A

    更新日期:2002-11-01 00:00:00

  • Adaptation of a clustered lumpy background model for task-based image quality assessment in x-ray phase-contrast mammography.

    abstract:PURPOSE:Since the introduction of clinical x-ray phase-contrast mammography (PCM), a technique that exploits refractive-index variations to create edge enhancement at tissue boundaries, a number of optimization studies employing physical image-quality metrics have been performed. Ideally, task-based assessment of PCM w...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3676183

    authors: Zysk AM,Brankov JG,Wernick MN,Anastasio MA

    更新日期:2012-02-01 00:00:00

  • Film dosimetry analyses on the effect of gold shielding for iodine-125 eye plaque therapy for choroidal melanoma.

    abstract::One of the methods currently being used to treat choroidal melanoma employs an episcleral plaque containing I-125 radioactive seeds. However, comprehensive dosimetry studies on the plaque are scarce and controversial. For this work, we use film to study the dosimetry outside the lip of the gold shield of the eye plaqu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596556

    authors: Wu A,Krasin F

    更新日期:1990-09-01 00:00:00

  • SU-E-T-04: Repair Kinetics of Sublethal Damage in Rat Cervical Spinal Cord - Application of the GLQ Model Incorporating Reciprocal Time Pattern.

    abstract:PURPOSE:The repair rate conventionally assumed to be constant during the entire radiation course. However, increasing evidences from animal studies show that the repair process may slow down with time and the experimental data does not fit an exponential pattern. To address this enigma, we presented a generalized linea...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735058

    authors: Huang Z,Mayr NA,Lo SS,McLawhorn R,Gao M,Liu T,Yuh W

    更新日期:2012-06-01 00:00:00

  • Photon-beam subsource sensitivity to the initial electron-beam parameters.

    abstract::One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC sour...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1884385

    authors: Fix MK,Keall PJ,Siebers JV

    更新日期:2005-04-01 00:00:00

  • The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75.

    abstract::Radiographic image guidance has emerged as the new paradigm for patient positioning, target localization, and external beam alignment in radiotherapy. Although widely varied in modality and method, all radiographic guidance techniques have one thing in common--they can give a significant radiation dose to the patient....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2775667

    authors: Murphy MJ,Balter J,Balter S,BenComo JA Jr,Das IJ,Jiang SB,Ma CM,Olivera GH,Rodebaugh RF,Ruchala KJ,Shirato H,Yin FF

    更新日期:2007-10-01 00:00:00

  • The tracks of the Compton effect.

    abstract::The observation of scattered radiations of larger wavelength than the primary had been repeatedly rejected or explained away by many researchers, including Compton. After years of vacillations, he recognized the effect named after him and was the first to develop a quantal equation predicting the wavelength of scatter...

    journal_title:Medical physics

    pub_type: 传,历史文章,杂志文章

    doi:10.1118/1.595046

    authors: del Regato JA

    更新日期:1981-11-01 00:00:00

  • Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.

    abstract:PURPOSE:To characterize a new air vented ionization chamber technology, suitable to build detector arrays with small pixel pitch and independence of sensitivity on dose per pulse. METHODS:The prototype under test is a linear array of air vented ionization chambers, consisting of 80 pixels with 3.5 mm pixel pitch dista...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4945414

    authors: Togno M,Wilkens JJ,Menichelli D,Oechsner M,Perez-Andujar A,Morin O

    更新日期:2016-05-01 00:00:00

  • SU-E-I-69: Magnetic Resonance Metal Artifact Evaluation with Routine Clinical Cardiac Sequences.

    abstract:PURPOSE:To examine schemes to grade the severity of metal susceptibility artifacts on image quality using cardiac MRI pulse sequences. METHODS:A post-thoracotomy patient was simulated with a stainless steel sternal wire (Syneture,MA; size=6, diameter=48mm), placed securely on an ACR MRI phantom. Phantom was scanned on...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734785

    authors: Joyner D,Rivard A,Craft D,Liu T,Callaway S,James J

    更新日期:2012-06-01 00:00:00

  • SU-E-T-283: Carbon Ion Therapy Innovations in Dosimetry and Dose Delivery.

    abstract:OBJECTIVE:Carbon ion particle therapy delivers sharp Bragg's peaks, and hence can produce dose delivery of very high precision and conformality. To complement this characteristic, particle therapy centers implement a number of technologies unique to these centers, and are not commonly known to the medical physics commu...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735351

    authors: Cernica G,Mun S

    更新日期:2012-06-01 00:00:00

  • A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac.

    abstract:PURPOSE:To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for render...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4773883

    authors: Gete E,Duzenli C,Milette MP,Mestrovic A,Hyde D,Bergman AM,Teke T

    更新日期:2013-02-01 00:00:00

  • SU-E-T-269: The Evaluation of Copper as an Alternative for Cerrobend Electron Shielding.

    abstract:PURPOSE:To evaluate the replacement of Cerrobend by copper for electron beam cutouts. METHODS:The dosimetric comparisons for circular copper-and Cerrobend-cutouts with diameters (1.0, 2.0, 3.0, 5.0, 7.5, 10.0, and 12.5 cm) were made using electron beams with energies (6, 9, 12, 16, and 20 MeV) from 3 Varian accelerato...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735336

    authors: Chu A,Feng W,Ahmad M,Chen Z,Nath R

    更新日期:2012-06-01 00:00:00

  • Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.

    abstract:PURPOSE:Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI refer...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4958677

    authors: Koivula L,Wee L,Korhonen J

    更新日期:2016-08-01 00:00:00

  • Evaluation of two methods of predicting MLC leaf positions using EPID measurements.

    abstract::In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2335490

    authors: Parent L,Seco J,Evans PM,Dance DR,Fielding A

    更新日期:2006-09-01 00:00:00

  • A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.

    abstract:PURPOSE:Intensity-modulated proton therapy (IMPT) is known to be sensitive to patient setup and range uncertainty issues. Multiple robust optimization methods have been developed to mitigate the impact of these uncertainties. Here, we propose a new robust optimization method, which provides an alternative way of robust...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13276

    authors: Shan J,Sio TT,Liu C,Schild SE,Bues M,Liu W

    更新日期:2019-01-01 00:00:00