Computer-aided detection of mammographic microcalcifications: pattern recognition with an artificial neural network.

Abstract:

:We are developing a computer program for automated detection of clustered microcalcifications on mammograms. In this study, we investigated the effectiveness of a signal classifier based on a convolution neural network (CNN) approach for improvement of the accuracy of the detection program. Fifty-two mammograms with clustered microcalcifications were selected from patient files. The clusters on the mammograms were ranked by experienced mammographers and divided into an obvious group, an average group, and a subtle group. The average and subtle groups were combined and randomly divided into two sets, each of which was used as training or test set alternately. The obvious group served as an additional independent test set. Regions of interest (ROIs) containing potential individual microcalcifications were first located on each mammogram by the automated detection program. The ROIs from one set of the mammograms were used to train CNNs of different configurations with a back-propagation method. The generalization capability of the trained CNNs was then examined by their accuracy of classifying the ROIs from the other set and from the obvious group. The classification accuracy of the CNNs for the ROIs was evaluated by receiver operating characteristic (ROC) analysis. It was found that CNNs of many different configurations can reach approximately the same performance level, with the area under the ROC curve (Az) of 0.9. We incorporated a trained CNN into the detection program and evaluated the improvement of the detection accuracy by the CNN using free response ROC analysis. Our results indicated that, over a wide range of true-positive (TP) cluster detection rate, the CNN classifier could reduce the number of false-positive (FP) clusters per image by more than 70%. For the obvious cases, at a TP rate of 100%, the FP rate reduced from 0.35 cluster per image to 0.1 cluster per image. For the average and subtle cases, the detection accuracy improved from a TP rate of 87% at an FP rate of four clusters per image to a TP rate of 90% at an FP rate of 1.5 clusters per image.

journal_name

Med Phys

journal_title

Medical physics

authors

Chan HP,Lo SC,Sahiner B,Lam KL,Helvie MA

doi

10.1118/1.597428

subject

Has Abstract

pub_date

1995-10-01 00:00:00

pages

1555-67

issue

10

eissn

0094-2405

issn

2473-4209

journal_volume

22

pub_type

杂志文章
  • A systematic Monte Carlo study of secondary electron fluence perturbation in clinical proton beams (70-250 MeV) for cylindrical and spherical ion chambers.

    abstract::Current dosimetry protocols for clinical protons do not take into account any secondary electron fluence perturbation in ion chambers. In this work, we performed a systematic study of secondary electron fluence perturbation factors for spherical and cylindrical ion chambers in proton beams (70-250 MeV). The electron f...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406519

    authors: Verhaegen F,Palmans H

    更新日期:2001-10-01 00:00:00

  • Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance.

    abstract:PURPOSE:Design and optimization of medical imaging systems benefit from accurate theoretical modeling that identifies the physical factors governing image quality, particularly in the early stages of system development. This work extends Fourier metrics of imaging performance and detectability index (d') to tomosynthes...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3560428

    authors: Gang GJ,Lee J,Stayman JW,Tward DJ,Zbijewski W,Prince JL,Siewerdsen JH

    更新日期:2011-04-01 00:00:00

  • SU-E-J-139: Feasibility of Using EPID for Real-Time Target Localization during Treatment.

    abstract:PURPOSE:This study aims to investigate the feasibility of using the images of the treatment fields acquired by an electronic portal imaging device (EPID) for real-time target localization. METHODS:Forty one patients treated with IMRT and RapidArc were recruited in this study including 37 prostate patients and 4 lung p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734975

    authors: Xu Q,Lin M,Chen X,Tong X,Fan J,Dong Z,Chen L,Ma C

    更新日期:2012-06-01 00:00:00

  • The effect of angular spread on the intensity distribution of arbitrarily shaped electron beams.

    abstract::Knowledge of the relative intensity distribution at the patient's surface is essential for pencil beam calculations of three-dimensional dose distributions for arbitrarily shaped electron beams. To calculate the relative intensity distribution, the spatial spread resulting from angular spread is convolved with a two-d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596252

    authors: Mohan R,Chui CS,Fontenla D,Han K,Ballon D

    更新日期:1988-03-01 00:00:00

  • Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator.

    abstract:PURPOSE:To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. METHODS:In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4719962

    authors: Lundh O,Rechatin C,Faure J,Ben-Ismaïl A,Lim J,De Wagter C,De Neve W,Malka V

    更新日期:2012-06-01 00:00:00

  • A multi-institutional study to assess adherence to lung stereotactic body radiotherapy planning goals.

    abstract:PURPOSE:A multi-institutional planning study was performed to evaluate the frequency that current guidelines established by Radiation Therapy Oncology Group (RTOG) protocols and other literature for lung stereotactic body radiotherapy (SBRT) treatments are followed. METHODS:A total of 300 patients receiving lung SBRT ...

    journal_title:Medical physics

    pub_type: 杂志文章,多中心研究

    doi:10.1118/1.4926551

    authors: Woerner A,Roeske JC,Harkenrider MM,Fan J,Aydogan B,Koshy M,Laureckas R,Vali F,Campana M,Surucu M

    更新日期:2015-08-01 00:00:00

  • Improved gradient-echo 3D magnetic resonance imaging using compressed sensing and Toeplitz encoding with phase-scrambled RF excitation.

    abstract:PURPOSE:To develop a novel three-dimensional (3D) hybrid-encoding framework using compressed sensing (CS) and Toeplitz encoding with variable phase-scrambled radio-frequency (RF) excitation, which has the following advantages: low power deposition of RF pulses, reduction of the signal dynamic range, no additional hardw...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13987

    authors: Wang H,Liang D,Su S,King KF,Chang Y,Liu X,Zheng H,Ying L

    更新日期:2020-04-01 00:00:00

  • The impact of small motion on the visualization of coronary vessels and lesions in cardiac CT: A simulation study.

    abstract:PURPOSE:Coronary x-ray computed tomography angiography (CCTA) is used to non-invasively assess coronary artery geometry and has, combined with computational modeling, demonstrated the potential to identify physiologically significant lesions. These measurements require robust and accurate coronary imaging and delineati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12295

    authors: Contijoch F,Stayman JW,McVeigh ER

    更新日期:2017-07-01 00:00:00

  • Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm.

    abstract:PURPOSE:Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4935199

    authors: Van Uytven E,Van Beek T,McCowan PM,Chytyk-Praznik K,Greer PB,McCurdy BM

    更新日期:2015-12-01 00:00:00

  • Simple design for a Styrofoam cutter.

    abstract::The design and construction of a Styrofoam cutter used in the fabrication of custom shielding blocks is described. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594206

    authors: Sorensen A,Goshaw L

    更新日期:1975-11-01 00:00:00

  • Technical note: A novel boundary condition using contact elements for finite element based deformable image registration.

    abstract::Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1774131

    authors: Zhang T,Orton NP,Mackie TR,Paliwal BR

    更新日期:2004-09-01 00:00:00

  • Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam.

    abstract:PURPOSE:IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4921617

    authors: Sugama Y,Nishio T,Onishi H

    更新日期:2015-07-01 00:00:00

  • Anniversary paper: evolution of ultrasound physics and the role of medical physicists and the AAPM and its journal in that evolution.

    abstract::Ultrasound has been the greatest imaging modality worldwide for many years by equipment purchase value and by number of machines and examinations. It is becoming increasingly the front end imaging modality; serving often as an extension of the physician's fingers. We believe that at the other extreme, high-end systems...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.2992048

    authors: Carson PL,Fenster A

    更新日期:2009-02-01 00:00:00

  • SU-E-J-11: Characterization of Interfractioanal Anatomical Variations in Post-Operative Radiation Therapy for Prostate Bed.

    abstract:PURPOSE:To quantitatively characterize the interfractional anatomic variations in post-operative radiation therapy (RT) for prostate bed, so that appropriate strategy that can fully address these variations can be developed. METHODS:A total of 102 daily pre-treatment CT acquired using an in-room CT (CTVision, Siemens)...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734844

    authors: Liu F,Ahunbay E,Christian R,Lawton C,Wang D,Li X

    更新日期:2012-06-01 00:00:00

  • Evaluation of diffusion models in breast cancer.

    abstract:PURPOSE:The purpose of this study is to investigate whether the microvascular pseudodiffusion effects resulting with non-monoexponential behavior are present in breast cancer, taking into account tumor spatial heterogeneity. Additionally, methodological factors affecting the signal in low and high diffusion-sensitizing...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927255

    authors: Panek R,Borri M,Orton M,O'Flynn E,Morgan V,Giles SL,deSouza N,Leach MO,Schmidt MA

    更新日期:2015-08-01 00:00:00

  • High-speed photography during ultrasound illustrates potential therapeutic applications of microbubbles.

    abstract::Ultrasound contrast agents consist of microscopically small encapsulated bubbles that oscillate upon insonification. To enhance diagnostic ultrasound imaging techniques and to explore therapeutic applications, these medical microbubbles have been studied with the aid of high-speed photography. We filmed medical microb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2133718

    authors: Postema M,van Wamel A,ten Cate FJ,de Jong N

    更新日期:2005-12-01 00:00:00

  • Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm.

    abstract:PURPOSE:The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. METHODS:The authors describe a DIR based adaptive radiotherapy workflow...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4905050

    authors: Veiga C,Lourenço AM,Mouinuddin S,van Herk M,Modat M,Ourselin S,Royle G,McClelland JR

    更新日期:2015-02-01 00:00:00

  • Primary dose in photon beams with lateral electron disequilibrium.

    abstract::It is shown that in narrow monoenergetic photon beams under conditions of lateral electron disequilibrium, primary absorbed dose P(r) is a simple function of beam radius r: P(r) = P lambda.(1 - e(-gamma.r)), where P lambda is the primary dose in broad beams for which complete lateral electron equilibrium exists, and g...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596741

    authors: Nizin PS,Chang XS

    更新日期:1991-07-01 00:00:00

  • The influence of field strength and different clinical breast MRI protocols on the outcome of texture analysis using foam phantoms.

    abstract:PURPOSE:Texture analysis (TA) has proved to be useful to distinguish different tissues and disease states using magnetic resonance imaging (MRI). TA has been successfully applied clinically to improve identification of abnormalities in the brain, liver, and bone and, more recently, has been used to enhance the specific...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3622605

    authors: Waugh SA,Lerski RA,Bidaut L,Thompson AM

    更新日期:2011-09-01 00:00:00

  • Backscatter factors in the mammographic energy range.

    abstract::Backscatter factors for kVps and half-value layers typical of mammographic beams have been determined as a function of beam diameter and half-value layer. The method utilized thin TLD-100 chips with the scattering medium alternately present and absent. Results indicate that the field-size dependence of the backscatter...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594312

    authors: Dubuque GL,Cacak RK,Hendee WR

    更新日期:1977-09-01 00:00:00

  • Potential increase in biological effectiveness from field timing optimization for stereotactic body radiation therapy.

    abstract:PURPOSE:Stereotactic body radiation therapy (SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses, treatments are typically protracted and there are more fields than in conventional radiation treatment schemes. The effect of tem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4709605

    authors: Schmitt JD,Warren GW,Wang IZ

    更新日期:2012-06-01 00:00:00

  • A real-time prostate cancer detection technique using needle insertion force and patient-specific criteria during percutaneous intervention.

    abstract::In this article, the authors present a novel real-time cancer detection technique by using needle insertion forces in conjunction with patient-specific criteria during percutaneous interventions. Needle insertion experiments and pathological analysis were performed for developing a computer-aided detection (CAD) model...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3148834

    authors: Yan K,Li L,Joseph J,Rubens DR,Messing EM,Liao L,Yu Y

    更新日期:2009-07-01 00:00:00

  • Dose-averaged LET calculation for proton track segments using microdosimetric Monte Carlo simulations.

    abstract:PURPOSE:There is an increasing interest in calculating linear energy transfer (LET) distributions for proton therapy treatments in order to assess the influence of this quantity in biological terms. Microdosimetric Monte Carlo (MC) simulations are useful tools to calculate dose-averaged LET, as this has been broadly pr...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13643

    authors: Bertolet A,Baratto-Roldán A,Barbieri S,Baiocco G,Carabe A,Cortés-Giraldo MA

    更新日期:2019-09-01 00:00:00

  • A boundary element approach for image-guided near-infrared absorption and scatter estimation.

    abstract::Multimodality NIR spectroscopy systems offer the possibility of region-based vascular and molecular characterization of tissue in vivo. However, computationally efficient 3D image reconstruction algorithms specific to these image-guided systems currently do not exist. Image reconstruction is often based on finite-elem...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2795832

    authors: Srinivasan S,Pogue BW,Carpenter C,Yalavarthy PK,Paulsen K

    更新日期:2007-11-01 00:00:00

  • Experimental determination of the "collimator monitoring fill factor" and its relation to the error detection capabilities of various 2D-arrays.

    abstract:PURPOSE:The collimator monitoring fill factor (CM-FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM-FF) introduced by Gago-Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D-arrays. The error detection capabilities of 2D-arrays were studied by co...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13417

    authors: Stelljes TS,Poppinga D,Kretschmer J,Brodbek L,Looe HK,Poppe B

    更新日期:2019-04-01 00:00:00

  • SU-E-I-94: External Beam Radiation Cherenkov Emission in Tissue Used for Tissue Oxygen Sensing.

    abstract:PURPOSE:To show that Cherenkov emission is generated by external radiotherapy beam in tissue, and could serve as optical source to excite an oxygen sensitive phosphor, Oxyphor G4, within tissue. The intensity and lifetime of the phosphorescence was measured with a time-gated system and reveals the oxygenation levels in...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734811

    authors: Zhang R,Kanick S,Vinogradov S,Esipova T,Pogue B

    更新日期:2012-06-01 00:00:00

  • A piecewise-focused high DQE detector for MV imaging.

    abstract:PURPOSE:Electronic portal imagers (EPIDs) with high detective quantum efficiencies (DQEs) are sought to facilitate the use of the megavoltage (MV) radiotherapy treatment beam for image guidance. Potential advantages include high quality (treatment) beam's eye view imaging, and improved cone-beam computed tomography (CB...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4927786

    authors: Star-Lack J,Shedlock D,Swahn D,Humber D,Wang A,Hirsh H,Zentai G,Sawkey D,Kruger I,Sun M,Abel E,Virshup G,Shin M,Fahrig R

    更新日期:2015-09-01 00:00:00

  • Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy.

    abstract:PURPOSE:Monte Carlo (MC) dose calculation is generally superior to analytical dose calculation (ADC) used in commercial TPS to model the dose distribution especially for heterogeneous sites, such as lung and head/neck patients. The purpose of this study was to provide a validated, fast, and open-source MC code, MCsquar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13231

    authors: Huang S,Souris K,Li S,Kang M,Barragan Montero AM,Janssens G,Lin A,Garver E,Ainsley C,Taylor P,Xiao Y,Lin L

    更新日期:2018-12-01 00:00:00

  • Technical Note: modification of the standard gain correction algorithm to compensate for the number of used reference flat frames in detector performance studies.

    abstract:PURPOSE:The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3664003

    authors: Konstantinidis AC,Olivo A,Speller RD

    更新日期:2011-12-01 00:00:00

  • Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model.

    abstract:PURPOSE:The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three-dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12002

    authors: Geyer AM,Schwarz BC,Hobbs RF,Sgouros G,Bolch WE

    更新日期:2017-01-01 00:00:00