Evaluation of a device for indirect assessment of automatic exposure control systems.

Abstract:

:A test device which can indirectly measure the performance of an automatic exposure control system and which offers the potential to reduce the time and film requirements for such tests has been evaluated. Evaluation results demonstrate that the device can successfully predict image optical density to within +/- 0.10 optical density units over a wide range of imaging technical factors and image optical densities.

journal_name

Med Phys

journal_title

Medical physics

authors

Rossi RP

doi

10.1118/1.597252

subject

Has Abstract

pub_date

1994-01-01 00:00:00

pages

141-3

issue

1

eissn

0094-2405

issn

2473-4209

journal_volume

21

pub_type

杂志文章
  • Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.

    abstract:PURPOSE:To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. METHODS:Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. T...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13900

    authors: Liu J,Xu Y,Teymurazyan A,Papandreou Z,Pang G

    更新日期:2020-01-01 00:00:00

  • Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy.

    abstract:PURPOSE:Monte Carlo (MC) dose calculation is generally superior to analytical dose calculation (ADC) used in commercial TPS to model the dose distribution especially for heterogeneous sites, such as lung and head/neck patients. The purpose of this study was to provide a validated, fast, and open-source MC code, MCsquar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13231

    authors: Huang S,Souris K,Li S,Kang M,Barragan Montero AM,Janssens G,Lin A,Garver E,Ainsley C,Taylor P,Xiao Y,Lin L

    更新日期:2018-12-01 00:00:00

  • Automated registration of large deformations for adaptive radiation therapy of prostate cancer.

    abstract::Available deformable registration methods are often inaccurate over large organ variation encountered, for example, in the rectum and bladder. The authors developed a novel approach to accurately and effectively register large deformations in the prostate region for adaptive radiation therapy. A software tool combinin...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3095777

    authors: Godley A,Ahunbay E,Peng C,Li XA

    更新日期:2009-04-01 00:00:00

  • Dosimetric comparison of helical tomotherapy treatment plans for total marrow irradiation created using GPU and CPU dose calculation engines.

    abstract:PURPOSE:To compare optimization characteristics, plan quality, and treatment delivery efficiency between total marrow irradiation (TMI) plans using the new TomoTherapy graphic processing unit (GPU) based dose engine and CPU/cluster based dose engine. METHODS:Five TMI plans created on an anthropomorphic phantom were op...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4810936

    authors: Nalichowski A,Burmeister J

    更新日期:2013-07-01 00:00:00

  • SU-E-J-106: Atlas-Based Segmentation: Evaluation of a Multi-Atlas Approach for Lung Cancer.

    abstract:PURPOSE:Previous studies have shown atlas-based segmentation using a single best matched (SBM) atlas subject can significantly reduce contouring time. A new multi-atlas approach has been shown to provide greater accuracy than SBM for cancer of the head and neck. The goal of this study was to evaluate the multi-atlas te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734942

    authors: Pirozzi S,Horvat M,Piper J,Nelson A

    更新日期:2012-06-01 00:00:00

  • Noninvasive cardiac arrhythmia ablation with particle beams.

    abstract::Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to re...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1002/mp.12595

    authors: Graeff C,Bert C

    更新日期:2018-11-01 00:00:00

  • Computerized analysis of radiographic bone patterns: effect of imaging conditions on performance.

    abstract::We are developing computerized methods for characterizing the bone texture pattern from digitized skeletal radiographs. For this method to be useful clinically, it must be able to distinguish between weak and strong bone under the range of exposure conditions potentially encountered in the clinical setting. In this st...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598858

    authors: Chinander MR,Giger ML,Martell JM,Favus MJ

    更新日期:2000-01-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • Noninvasive eye localization in ocular proton therapy through optical eye tracking: A proof of concept.

    abstract:PURPOSE:Over the last four decades, Ocular Proton Therapy has been successfully used to treat patients affected by intraocular lesions. For this, treatment geometry verification is routinely performed using radiographic images to align a configuration of fiducial radiopaque markers implanted on the sclera outer surface...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12841

    authors: Via R,Hennings F,Fattori G,Fassi A,Pica A,Lomax A,Weber DC,Baroni G,Hrbacek J

    更新日期:2018-05-01 00:00:00

  • Hybrid ZTE/Dixon MR-based attenuation correction for quantitative uptake estimation of pelvic lesions in PET/MRI.

    abstract:PURPOSE:This study introduces a new hybrid ZTE/Dixon MR-based attenuation correction (MRAC) method including bone density estimation for PET/MRI and quantifies the effects of bone attenuation on metastatic lesion uptake in the pelvis. METHODS:Six patients with pelvic lesions were scanned using fluorodeoxyglucose (18F-...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12122

    authors: Leynes AP,Yang J,Shanbhag DD,Kaushik SS,Seo Y,Hope TA,Wiesinger F,Larson PE

    更新日期:2017-03-01 00:00:00

  • Use of simulated annealing for optimization of alignment parameters in limited MRI acquisition volumes of the brain.

    abstract::Studies suggest that clinical outcomes are improved in repeat trigeminal neuralgia (TN) Gamma Knife radiosurgery if a different part of the nerve from the previous radiosurgery is treated. The MR images taken in the first and repeat radiosurgery need to be coregistered to map the first radiosurgery volume onto the sec...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1944287

    authors: Li X,Zhang P,Brisman R,Kutcher G

    更新日期:2005-07-01 00:00:00

  • Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

    abstract::The performance of an indirect-detection, active matrix flat-panel imager (FPI) at diagnostic energies is reported in terms of measured and theoretical signal size, noise power spectrum (NPS), and detective quantum efficiency (DQE). Based upon a 1536 x 1920 pixel, 127 microns pitch array of a-Si:H thin-film transistor...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598243

    authors: Siewerdsen JH,Antonuk LE,el-Mohri Y,Yorkston J,Huang W,Cunningham IA

    更新日期:1998-05-01 00:00:00

  • The accuracy of SPECT brain activation images: propagation of registration errors.

    abstract::Functional single photon emission computed tomography (SPECT) images of brain activation are based on a comparison of base line and activation images. The correctness of the functional images depends, among other factors, on the accurate spatial registration (alignment) of the base line and activation image data. The ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597412

    authors: Sychra JJ,Pavel DG,Chen Y,Jani A

    更新日期:1994-10-01 00:00:00

  • Improved tissue assignment using dual-energy computed tomography in low-dose rate prostate brachytherapy for Monte Carlo dose calculation.

    abstract:PURPOSE:An improvement in tissue assignment for low-dose rate brachytherapy (LDRB) patients using more accurate Monte Carlo (MC) dose calculation was accomplished with a metallic artifact reduction (MAR) method specific to dual-energy computed tomography (DECT). METHODS:The proposed MAR algorithm followed a four-step ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4947486

    authors: Côté N,Bedwani S,Carrier JF

    更新日期:2016-05-01 00:00:00

  • Investigation of basic imaging properties in digital radiography. 9. Effect of displayed grey levels on signal detection.

    abstract::Results of an 18-alternative forced-choice experiment have shown that observers were capable of detecting a signal with a contrast of 1 in terms of 10-bit data which were displayed on a CRT monitor with an 8-bit video generator and a window width setting of 1024. We investigated the conditions under which 10-bit signa...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595919

    authors: Giger ML,Ohara K,Doi K

    更新日期:1986-05-01 00:00:00

  • The effect of z overscanning on radiation burden of pediatric patients undergoing head CT with multidetector scanners: a Monte Carlo study.

    abstract::The purpose of this study was to investigate the effect of z overscanning on eye lens dose and effective dose received by pediatric patients undergoing head CT examinations. A pediatric patient study was carried out to obtain the exposure parameters and data regarding the eye lens position with respect to imaged volum...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2207212

    authors: Tzedakis A,Perisinakis K,Raissaki M,Damilakis J

    更新日期:2006-07-01 00:00:00

  • Fast cross-projection algorithm for reconstruction of seeds in prostate brachytherapy.

    abstract::A fast method of seed matching and reconstruction in prostate brachytherapy is proposed. Previous approaches have required all seeds to be matched with all other seeds in other projections. The fast cross-projection algorithm for the reconstruction of seeds (Fast-CARS) allows for matching of a given seed with a subset...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1489044

    authors: Narayanan S,Cho PS,Marks RJ 2nd

    更新日期:2002-07-01 00:00:00

  • The thermal characteristics of different diodes on in vivo patient dosimetry.

    abstract::Diode sensitivity variations with temperature (SVWT) have been reported to vary from small negative values up to 0.6% per degrees C. Thus it is possible for diode calibration factors established at room temperature (approximately 20 degrees C) to yield errors in the range of -1% to +9% when diodes are placed on a pati...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1367862

    authors: Welsh KT,Reinstein LE

    更新日期:2001-05-01 00:00:00

  • Position detection accuracy of a novel linac-mounted intrafractional x-ray imaging system.

    abstract:PURPOSE:The authors have developed a system that monitors intrafractional target motion perpendicular to the treatment beam with the aid of radioopaque markers by means of separating kV image and megavoltage (MV) treatment field on a single flat-panel detector. METHODS:They equipped a research Siemens Artiste linear a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3665712

    authors: Fast MF,Krauss A,Oelfke U,Nill S

    更新日期:2012-01-01 00:00:00

  • Noninvasive x-ray tube current measurement.

    abstract::A clamp-on current probe utilizing the Hall effect was used to determine x-ray tube current. This noninvasive technique was compared to two other methods of mA measurement: the Machlett Dynalyzer and the mR/mAs linearity method. Three diagnostic x-ray units were used in the comparison; two modern three-phase rooms and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596080

    authors: Atherton JV,Nickoloff EL

    更新日期:1987-03-01 00:00:00

  • Characterizing the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations.

    abstract:PURPOSE:To characterize the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations. To assess the spatial resolution of proton/carbon radiographic imaging. METHODS:A phantom was specifically modeled with inserts composed of two materials with three different densities of bone and...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4819816

    authors: Seco J,Oumano M,Depauw N,Dias MF,Teixeira RP,Spadea MF

    更新日期:2013-09-01 00:00:00

  • A statistical approach to infer the minimum setup distance of a well chamber to the wall or to the floor for 192Ir HDR calibration.

    abstract::We propose a new method based on statistical analysis technique to determine the minimum setup distance of a well chamber used in the calibration of 192Ir high dose rate (HDR). The chamber should be placed at least this distance away from any wall or from the floor in order to mitigate the effect of scatter. Three dif...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2911156

    authors: Chang L,Ho SY,Chui CS,Lee JH,Du YC,Chen T

    更新日期:2008-06-01 00:00:00

  • SU-D-218-05: Material Quantification in Spectral X-Ray Imaging: Optimization and Validation.

    abstract:PURPOSE:To develop and validate a multivariate statistical method to optimize scanning parameters for material quantification in spectral x-rayimaging. METHODS:An optimization metric was constructed by extensively sampling the thickness space for the expected number of counts for m (two or three) materials. This resul...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4734708

    authors: Nik SJ,Thing RS,Watts R,Meyer J

    更新日期:2012-06-01 00:00:00

  • Practical reconstruction protocol for quantitative (90)Y bremsstrahlung SPECT/CT.

    abstract:PURPOSE:To develop a practical background compensation (BC) technique to improve quantitative (90)Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. METHODS:All images were acquired using medium-energy collimation in six energy wi...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4960629

    authors: Siman W,Mikell JK,Kappadath SC

    更新日期:2016-09-01 00:00:00

  • Reverse mapping of normal tissue complication probabilities onto dose volume histogram space: the problem of randomness of the dose volume histogram sampling.

    abstract::A very important issue in contemporary inverse treatment radiotherapy planning is the specification of proper dose-volume constraints limiting the treatment planning algorithm from delivering high doses to the normal tissue surrounding the tumor. Recently we have proposed a method called reverse mapping of normal tiss...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2198307

    authors: Markov K,Schinkel C,Stavreva N,Stavrev P,Weldon M,Fallone BG

    更新日期:2006-09-01 00:00:00

  • Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.

    abstract::The aim of this work was to test the suitability of a PTW diamond detector for nonreference condition dosimetry in photon beams of different energy (6 and 25 MV) and field size (from 2.6 cm x 2.6 cm to 10 cm x 10 cm). Diamond behavior was compared to that of a Scanditronix p-type silicon diode and a Scanditronix RK io...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1591431

    authors: Bucciolini M,Buonamici FB,Mazzocchi S,De Angelis C,Onori S,Cirrone GA

    更新日期:2003-08-01 00:00:00

  • Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.

    abstract::A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598325

    authors: Wang H,Smith MF,Stone CD,Jaszczak RJ

    更新日期:1998-08-01 00:00:00

  • Scatter correction using a primary modulator on a clinical angiography C-arm CT system.

    abstract:PURPOSE:Cone beam computed tomography (CBCT) suffers from a large amount of scatter, resulting in severe scatter artifacts in the reconstructions. Recently, a new scatter correction approach, called improved primary modulator scatter estimation (iPMSE), was introduced. That approach utilizes a primary modulator that is...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12094

    authors: Bier B,Berger M,Maier A,Kachelrieß M,Ritschl L,Müller K,Choi JH,Fahrig R

    更新日期:2017-09-01 00:00:00

  • Iterative reconstruction method for light emitting sources based on the diffusion equation.

    abstract::Bioluminescent imaging (BLI) of luciferase-expressing cells in live small animals is a powerful technique for investigating tumor growth, metastasis, and specific biological molecular events. Three-dimensional imaging would greatly enhance applications in biomedicine since light emitting cell populations could be unam...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2138007

    authors: Slavine NV,Lewis MA,Richer E,Antich PP

    更新日期:2006-01-01 00:00:00

  • Eddy current disruption: effect on nuclear magnetic resonance coil impedance and power loss.

    abstract::We present a theoretical development and experimental verification of a description of power loss and sample resistance for a lossy sample in a nuclear magnetic resonance radio frequency coil for a sample geometry where the eddy current streamlines are disrupted from their usually assumed circular paths. Specifically ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596336

    authors: Harpen MD

    更新日期:1989-09-01 00:00:00