WE-G-217A-08: Routine ACR SNR Measurement Failed to Detect 32-Channel Head Coil Receiver Malfunction.

Abstract:

PURPOSE:To study if malfunction of a receiver can be detected robustly using the simple ACR SNR measurement approach on a 32-channel head coil. METHODS:Standard ACR T1W images (11slice) were acquired with a commercial 32 channel head coil on a 3T Philips Achieva MR scanner following the ACR recommended setup. Raw data were saved and were used to reconstruct 32 image datasets, each with one coil channel turned off and signal were excluded from reconstruction. Routine simple SNR evaluation method was used to measure SNR for each dataset. Specifically, region of interest (ROI) analysis was performed on slice #7 for each dataset. Signal was the mean value of the pixel intensity measured using an ROI with area of 200 cm2 positioned at the center of phantom. Noise was the standard deviation derived from an ROI positioned in the background in a corner of the image. SNR was then calculated from signal divided by noise. For comparison purposes, we empirically chose 5% SNR drop compared to the full 32 channel dataset SNR as a significant SNR drop that is correlated a potential coil channel defect. RESULTS:Among the 32 image datasets reconstructed each with one receiver turned off, only 4 showed SNR drop of more than 5% or more compared to the reference SNR obtained from the original dataset. Four other datasets had SNR drop between 0.1-5%. The rest (24 image sets) did not show any SNR drop. Therefore, SNR monitoring based on the large ROI approach as the routine ACR QC procedure failed detect receiver malfunction in this coil. CONCLUSIONS:More advanced and thorough coil evaluation methods, instead of the routine simple ACR SNR measurement method, have to be applied to evaluate the performance of the phased-array head coil with 32 or more channels.

journal_name

Med Phys

journal_title

Medical physics

authors

Peng Q

doi

10.1118/1.4736227

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

3976

issue

6Part28

eissn

0094-2405

issn

2473-4209

journal_volume

39

pub_type

杂志文章
  • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

    abstract::In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the pat...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1589496

    authors: Louwe RJ,Damen EM,van Herk M,Minken AW,Törzsök O,Mijnheer BJ

    更新日期:2003-09-01 00:00:00

  • Ethics and professionalism in medical physics: a survey of AAPM members.

    abstract:PURPOSE:To assess current education, practices, attitudes, and perceptions pertaining to ethics and professionalism in medical physics. METHODS:A link to a web-based survey was distributed to the American Association of Physicists in Medicine (AAPM) e-mail membership list, with a follow-up e-mail sent two weeks later....

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4797463

    authors: Ozturk N,Armato SG 3rd,Giger ML,Serago CF,Ross LF

    更新日期:2013-04-01 00:00:00

  • A method of rapid quantification of patient-specific organ doses for CT using deep-learning-based multi-organ segmentation and GPU-accelerated Monte Carlo dose computing.

    abstract:PURPOSE:One technical barrier to patient-specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient-specific multi-organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14131

    authors: Peng Z,Fang X,Yan P,Shan H,Liu T,Pei X,Wang G,Liu B,Kalra MK,Xu XG

    更新日期:2020-06-01 00:00:00

  • Carpal tunnel syndrome diagnosis by a self-normalization process and ultrasound compound imaging.

    abstract:PURPOSE:Carpal tunnel syndrome (CTS) is the common entrapment neuropathy that occurs due to compression of the median nerve at the wrist. Ultrasound images have been used to highlight anatomical variants of the median nerve, and CTS is thought to be associated to enlargement of the cross-sectional area (CSA) of the med...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4767754

    authors: Liao YY,Wu CC,Kuo TT,Chen JP,Hsu YW,Yeh CK

    更新日期:2012-12-01 00:00:00

  • Computational modeling of 915 MHz microwave ablation: Comparative assessment of temperature-dependent tissue dielectric models.

    abstract:PURPOSE:The objective of this study is to develop a computational model for simulating 915 MHz microwave ablation (MWA), and verify the simulation predictions of transient temperature profiles against experimental measurements. Due to the limited experimental data characterizing temperature-dependent changes of tissue ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12359

    authors: Deshazer G,Hagmann M,Merck D,Sebek J,Moore KB,Prakash P

    更新日期:2017-09-01 00:00:00

  • Repeatability of SUV measurements in serial PET.

    abstract:PURPOSE:The standardized uptake value (SUV) is a quantitative measure of FDG tumor uptake frequently used as a tool to monitor therapeutic response. This study aims to (i) assess the reproducibility and uncertainty of SUV max and SUV mean, due to purely statistical, i.e., nonbiological, effects and (ii) to establish th...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3578604

    authors: Schwartz J,Humm JL,Gonen M,Kalaigian H,Schoder H,Larson SM,Nehmeh SA

    更新日期:2011-05-01 00:00:00

  • Estimation of a photon energy spectrum for a computed tomography scanner.

    abstract::Estimated photon energy spectra are derived from transmission measurements using aluminium, copper, and sodium iodide absorbers. Two spectral models are proposed. One is based on a previously published model that analyzes the electron's penetration into the anode, and the production and attenuation of bremsstrahlung p...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598159

    authors: Ruth C,Joseph PM

    更新日期:1997-05-01 00:00:00

  • Vision 20/20: Mammographic breast density and its clinical applications.

    abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935141

    authors: Ng KH,Lau S

    更新日期:2015-12-01 00:00:00

  • Evaluating the impact of extended field-of-view CT reconstructions on CT values and dosimetric accuracy for radiation therapy.

    abstract:PURPOSE:Wide bore CT scanners use extended field-of-view (eFOV) reconstruction algorithms to attempt to recreate tissue truncated due to large patient habitus. Radiation therapy planning systems rely on accurate CT numbers in order to correctly plan and calculate radiation dose. This study looks at the impact of eFOV r...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13299

    authors: Cheung JP,Shugard E,Mistry N,Pouliot J,Chen J

    更新日期:2019-02-01 00:00:00

  • Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography.

    abstract::In this paper, a unified framework of iterative algebraic reconstruction for emission computed tomography (ECT) and its application to positron emission tomography (PET) is presented. The unified framework is based on an algebraic image restoration model and contains conventional iterative algebraic reconstruction alg...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.596954

    authors: Xu XL,Liow JS,Strother SC

    更新日期:1993-11-01 00:00:00

  • Establishment of a beam line at the Fermi National Accelerator Laboratory for proton radiography.

    abstract::A proton beam is extracted from the 200-MeV linear accelerator at the Fermi National Accelerator Laboratory to investigate the efficacy of proton radiography in medical diagnosis. Fluence rates from 2 X 10(3) to 2 X 10(5) protons/cm2s over a 28-cm diameter field are obtained with a full width at half-maximum beam-ener...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.594426

    authors: Curry J,Steward VW

    更新日期:1978-05-01 00:00:00

  • Measured electron energy and angular distributions from clinical accelerators.

    abstract::Electron energy spectra and angular distributions, including angular spreads, were measured using magnetic spectrometer techniques, at isocenter, for two clinical linear accelerators: one scanning beam machine, which achieves field flatness by scanning a pencil beam over the desired field at the patient plane, and one...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597817

    authors: Deasy JO,Almond PR,McEllistrem MT

    更新日期:1996-05-01 00:00:00

  • Bremsstrahlung production at 50 MeV in different target materials and configurations.

    abstract::A combination of Monte Carlo, convolution, and experimental techniques have been used to investigate bremsstrahlung production at 50 MeV in full-range targets to produce narrow elementary photon beams for scanning. Calculations using the ITS 3.0 Monte Carlo system for various target designs, including particle transpo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597681

    authors: Sätherberg A,Andreo P,Karlsson M

    更新日期:1996-04-01 00:00:00

  • The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapy.

    abstract::Methods for scatter dose calculations in brachytherapy have been developed based on the collapsed cone superposition algorithm. The methods account for effects on the scatter dose caused by the three-dimensional distribution of heterogeneities in the irradiated volume and are considerably faster than methods based on ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1290485

    authors: Carlsson AK,Ahnesjö A

    更新日期:2000-10-01 00:00:00

  • Effect of Contrast Agent Administration on Water Equivalent Diameter in CT.

    abstract:PURPOSE:Water equivalent diameter (WED) is the preferred surrogate for patient size in CT. It is better than geometric size surrogates and patient weight/height/BMI/age because it correlates the best with x-ray attenuation. The administration of oral/IV contrast agents increases a patient's attenuation and should there...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14721

    authors: Viggiano B,Rose S,Szczykutowicz TP

    更新日期:2021-01-13 00:00:00

  • Optimization of power deposition and a heating strategy for external ultrasound thermal therapy.

    abstract::The purpose of this paper is to examine the thermal dose distribution, to configure the optimal absorbed power deposition, and to design an appropriate heating strategy for ultrasound thermal therapy. This work employs simulation programs, which are based on the transient bio-heat transfer equation and an ideal absorb...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1406516

    authors: Lin WL,Liang TC,Yen JY,Liu HL,Chen YY

    更新日期:2001-10-01 00:00:00

  • Partial volume segmentation of brain magnetic resonance images based on maximum a posteriori probability.

    abstract::Noise, partial volume (PV) effect, and image-intensity inhomogeneity render a challenging task for segmentation of brain magnetic resonance (MR) images. Most of the current MR image segmentation methods focus on only one or two of the above-mentioned effects. The objective of this paper is to propose a unified framewo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1944912

    authors: Li X,Li L,Lu H,Liang Z

    更新日期:2005-07-01 00:00:00

  • Accuracy of a 3D laser∕camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments.

    abstract:PURPOSE:The aim of this paper is to investigate the accuracy of a laser∕camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. METHODS:The system was tested on t...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4769428

    authors: Pallotta S,Simontacchi G,Marrazzo L,Ceroti M,Paiar F,Biti G,Bucciolini M

    更新日期:2013-01-01 00:00:00

  • Evaluations of magnetic resonance imaging parameters with simple phantoms.

    abstract::Imaging parameters associated with a clinical magnetic resonance imaging (MRI) system, evaluated with the use of simple and inexpensive phantoms, are described in evaluation of a clinical MRI system. Images, obtained with a Diasonics 0.35-T MRI system using an elliptical whole-body radio frequency coil, are presented ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595894

    authors: Brateman L,Jennings LW,Nunnally RL,Vaughan JT

    更新日期:1986-07-01 00:00:00

  • Measurements of magnetism-related forces and torque moments affecting medical instruments, implants, and foreign objects during magnetic resonance imaging at all degrees of freedom.

    abstract::We designed a novel force/torque moment transducer with six degrees of freedom. This new sensor is used for measuring the forces and torque moments exerted by static magnetic resonance imaging (MRI) fields on various medical implants, instruments, and ballistic shell fragments. To determine the location of strongest e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597853

    authors: Planert J,Modler H,Vosshenrich R

    更新日期:1996-06-01 00:00:00

  • Implementing RapidArc into clinical routine: a comprehensive program from machine QA to TPS validation and patient QA.

    abstract:PURPOSE:With the increased commercial availability of intensity modulated arc therapy (IMAT) comes the need for comprehensive QA programs, covering the different aspects of this newly available technology. This manuscript proposes such a program for the RapidArc (RA) (Varian Medical Systems, Palo Alto) IMAT solution. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3622672

    authors: Van Esch A,Huyskens DP,Behrens CF,Samsoe E,Sjolin M,Bjelkengren U,Sjostrom D,Clermont C,Hambach L,Sergent F

    更新日期:2011-09-01 00:00:00

  • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems--a contrast-detail phantom study.

    abstract::Flat-panel (FP) based digital radiography systems have recently been introduced as a new and improved digital radiography technology; it is important to evaluate and compare this new technology with currently widely used conventional screen/film (SF) and computed radiography (CR) techniques. In this study, the low-con...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1408620

    authors: Rong XJ,Shaw CC,Liu X,Lemacks MR,Thompson SK

    更新日期:2001-11-01 00:00:00

  • In vivo surface dosimetry with a scintillating fiber dosimeter in preclinical image-guided radiotherapy.

    abstract:PURPOSE:New preclinical image-guided irradiators and treatment planning systems represent a huge progress in radiobiology. Nevertheless, quality control of preclinical treatments is not as advanced as in clinical radiotherapy and in vivo dosimetry is less developed. In this study, we evaluate the use of a scintillating...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.13903

    authors: Le Deroff C,Pérès EA,Ledoux X,Toutain J,Frelin-Labalme AM

    更新日期:2020-01-01 00:00:00

  • Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer.

    abstract:PURPOSE:To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer. METHOD:Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermo...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4748332

    authors: Donovan EM,James H,Bonora M,Yarnold JR,Evans PM

    更新日期:2012-10-01 00:00:00

  • Technical Note: Transconvolution based equalization of positron energy effects for the use of 68 Ge/68 Ga phantoms in determining 18 F PET recovery.

    abstract:PURPOSE:Avoiding measurement variability from 18 F phantom preparation by using 68 Ge/68 Ga phantoms for the determination of 18 F recovery curves (RC) in clinical quality assurance measurements and for PET/CT site qualification in multicentre clinical trials. METHODS:RCs were obtained from PET/CT measurements of seve...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12330

    authors: Prenosil GA,Hentschel M,Fürstner M,Krause T,Weitzel T,Klaeser B

    更新日期:2017-07-01 00:00:00

  • An automated procedure for the quality assurance of electron beam output and energy.

    abstract::In this article, we report on the development of a simple and accurate method for quality assurance of electron beam output and energy. Aluminum disks of thicknesses d(max) or d50 of the particular electron energy are positioned sequentially over a parallel-plate ion chamber and the ratio of the two signals is compare...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1688040

    authors: Woo MK,Videla NG

    更新日期:2004-05-01 00:00:00

  • Proton magnetic resonance spectroscopy in the brain: report of AAPM MR Task Group #9.

    abstract::AAPM Magnetic Resonance Task Group #9 on proton magnetic resonance spectroscopy (MRS) in the brain was formed to provide a reference document for acquiring and processing proton (1H) MRS acquired from brain tissue. MRS is becoming a common adjunct to magnetic resonance imaging (MRI), especially for the differential di...

    journal_title:Medical physics

    pub_type: 指南,杂志文章,实务指引,评审

    doi:10.1118/1.1501822

    authors: Drost DJ,Riddle WR,Clarke GD,AAPM MR Task Group #9.

    更新日期:2002-09-01 00:00:00

  • A new open-source GPU-based microscopic Monte Carlo simulation tool for the calculations of DNA damages caused by ionizing radiation - Part II: sensitivity and uncertainty analysis.

    abstract:PURPOSE:Calculations of deoxyribonucleic acid (DNA) damages involve many parameters in the computation process. As these parameters are often subject to uncertainties, it is of central importance to comprehensively quantify their impacts on DNA single-strand break (SSB) and double-strand break (DSB) yields. This has be...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14036

    authors: Lai Y,Tsai MY,Tian Z,Qin N,Yan C,Hung SH,Chi Y,Jia X

    更新日期:2020-04-01 00:00:00

  • 3D MTF estimation using sphere phantoms for cone-beam computed tomography systems.

    abstract:PURPOSE:For cone-beam computed tomography (CBCT) systems, we propose a sphere phantom based method to estimate the full three-dimensional (3D) modulation transfer function (MTF). METHODS:The FDK reconstruction of CBCT system in a local region was modeled by a triple convolution operator. Afterward, we calculated the d...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14147

    authors: Lee C,Song HD,Baek J

    更新日期:2020-07-01 00:00:00

  • Clinical implementation of a Monte Carlo treatment planning system.

    abstract::The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy dose calculations. We used the EGS4/BEAM code to obtain the phase-space data for 6-20 MeV electron beams and 4, 6, and 15 MV photon beams for Varian Clinac 1800, 2100C, and 2300CD accelerators. A multiple-source model was used ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598729

    authors: Ma CM,Mok E,Kapur A,Pawlicki T,Findley D,Brain S,Forster K,Boyer AL

    更新日期:1999-10-01 00:00:00