Abstract:
:The noise power spectrum (NPS) is a useful metric for understanding the noise content in images. To examine some unique properties of the NPS of fan beam CT, the authors derived an analytical expression for the NPS of fan beam CT and validated it with computer simulations. The nonstationary noise behavior of fan beam CT was examined by analyzing local regions and the entire field-of-view (FOV). This was performed for cases with uniform as well as nonuniform noise across the detector cells and across views. The simulated NPS from the entire FOV and local regions showed good agreement with the analytically derived NPS. The analysis shows that whereas the NPS of a large FOV in parallel beam CT (using a ramp filter) is proportional to frequency, the NPS with direct fan beam FBP reconstruction shows a high frequency roll off. Even in small regions, the fan beam NPS can show a sharp transition (discontinuity) at high frequencies. These effects are due to the variable magnification and therefore are more pronounced as the fan angle increases. For cases with nonuniform noise, the NPS can show the directional dependence and additional effects.
journal_name
Med Physjournal_title
Medical physicsauthors
Baek J,Pelc NJdoi
10.1118/1.3378673subject
Has Abstractpub_date
2010-05-01 00:00:00pages
2074-81issue
5eissn
0094-2405issn
2473-4209journal_volume
37pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract:PURPOSE:This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. METHODS:A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treat...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4704496
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS:Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the us...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735493
更新日期:2012-06-01 00:00:00
abstract::The aim of the work was to investigate in advance the dosimetric properties of a new multileaf collimator (MLC) concept with the help of Monte Carlo (MC) simulations prior to the production of a prototype. The geometrical design of the MLC was implemented in the MC code GEANT4. For the simulation of a 6 MV treatment b...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2181298
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:Monte Carlo (MC) simulation can be used for accurate electron beam treatment planning and modeling. Measurement of large electron fields, with the applicator removed and secondary collimator wide open, has been shown to provide accurate simulation parameters, including asymmetry in the measured dose, for the fu...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3592640
更新日期:2011-06-01 00:00:00
abstract:PURPOSE:A long-standing conundrum is why photoacoustic tomography (PAT) possesses the unique ability to produce images devoid of speckle artifacts while all other coherent imaging technologies do not. METHODS:In this paper, we explain the inherent mechanism that suppresses speckle in PAT, and the analysis was validate...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3187231
更新日期:2009-09-01 00:00:00
abstract::Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution (<4 lp/mm). Micro-computed tomography (micro-CT)...
journal_title:Medical physics
pub_type: 信件
doi:10.1118/1.2989989
更新日期:2008-10-01 00:00:00
abstract::Generating an optimized radiation treatment plan requires understanding the factors affecting tumour control. Mathematical models of tumour dynamics may help in future studies of factors predicting tumor sensitivity to radiotherapy. In this study, a time-dependent differential model, incorporating biological cancer ma...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2965923
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:The Acuros XB (AXB) Advanced Dose algorithm (Varian Medical Systems) represents a dramatic shift in clinical photon dose calculation methodology from pencil-beam superposition/convolution methods. Early studies evaluating the accuracy of the algorithm in lung have found good agreement with both measurement and ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735574
更新日期:2012-06-01 00:00:00
abstract::A computationally efficient pseudodynamical filtering setup is established for elasticity imaging (i.e., reconstruction of shear modulus distribution) in soft-tissue organs given statically recorded and partially measured displacement data. Unlike a regularized quasi-Newton method (QNM) that needs inversion of ill-con...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3158808
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:The aiming is getting accurate liver contour structures automatically for following adaptive radiation therapy in daily CBCT images which is very low-contrast comparing the planning CT. METHODS:Probabilistic atlas is constructed by 50 intravenous contrast planning CT images by iterative affine registration pro...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4734730
更新日期:2012-06-01 00:00:00
abstract::In this paper, the consistency of kilovoltage (tube potentials between 40 and 300 kV) x-ray beam dosimetry using the "in-air" method and the in-phantom measurement has been studied. The procedures for the measurement of the central-axis depth-dose curve, which serve as a link between the dose at the reference depth to...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598448
更新日期:1998-12-01 00:00:00
abstract::We measured the physical imaging performance of a 41 x 41 cm2 amorphous silicon flat panel detector designed for angiographic and R&F imaging applications using methods from the emerging IEC standard for the measurement of detective quantum efficiency (DQE) in digital radiographic detectors. Measurements on 12 product...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.1609151
更新日期:2003-10-01 00:00:00
abstract:PURPOSE:The small number of samples available for training and testing is often the limiting factor in finding the most effective features and designing an optimal computer-aided diagnosis (CAD) system. Training on a limited set of samples introduces bias and variance in the performance of a CAD system relative to that...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3284974
更新日期:2010-02-01 00:00:00
abstract::An energy discriminating detector for dual-energy radiography can be configured as a two-layer sandwich, where the mean energy of photons detected by the two layers differs. To characterize the quantum noise of such a detector, the noise covariance between the two layers must be known in addition to the noise variance...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596311
更新日期:1989-11-01 00:00:00
abstract:PURPOSE:Polymer-based gel dosimeter (MAGIC type) is a preferable phantom material for PET range verification of proton beam therapy. However, improvement in elemental tissue equivalency (specifically O/C ratio) is very desirable to ensure realistic time-activity measurements. METHODS:Glucose and urea was added to the ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3260844
更新日期:2010-01-01 00:00:00
abstract::Scanning film densitometry routinely used for obtaining dosimetric information about therapy treatment beams is subject to several sources of inaccuracies. The most significant of these are described and appropriate methods of testing are presented. This establishes the need for adequate acceptance testing followed by...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595407
更新日期:1983-09-01 00:00:00
abstract::In intensity modulated radiation treatments (IMRT), the position of the field edges and the modulation within the beam are often achieved with a multileaf collimator (MLC). During the MLC calibration process, due to the finite accuracy of leaf position measurements, a systematic error may be introduced to leaf positio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2335490
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:To investigate the effect of energy (kVp) and filters (no filter, half Bowtie, and full Bowtie) on the dose response curves of the Gafchromic XRQA2 film and nanoDot optical stimulated luminescence dosimeters (OSLDs) in CBCT dose fields. To measure surface and internal doses received during x-ray volume imager (...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4803466
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is bett...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4905104
更新日期:2015-03-01 00:00:00
abstract::Interstitial brachytherapy for carcinoma of the prostate is achieved through the use of a configuration of radioactive seeds placed in a manner that delivers a customized, reasonably uniform dose to the target volume. Accurate dose delivery depends on both precise seed placement and reliable seed strength in the impla...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598877
更新日期:2000-01-01 00:00:00
abstract::A modified neutron production target assembly has been developed to provide improved performance of the proton-cyclotron-based neutron radiotherapy facility at the University of Washington for applications involving neutron capture enhanced fast-neutron therapy. The new target produces a neutron beam that yields essen...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.598839
更新日期:2000-02-01 00:00:00
abstract::The modulation transfer function (MTF) of a screen-film system can be measured by two methods, i.e., a slit method with Fourier transform on the line spread function and a square-wave response function (SWRF) method. However, it is still uncertain whether MTFs obtained by the two methods are identical. In this study, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.597456
更新日期:1995-02-01 00:00:00
abstract::Charge coupled devices (CCDs) are being increasingly used in radiation therapy for dosimetric purposes. However, CCDs are sensitive to stray radiation. This effect induces transient noise. Radiation-induced noise strongly alters the image and therefore limits its quantitative analysis. The purpose of this work is to c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2975147
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:The aim of this study was to use MRI gel dosimetry to determine the dose profile of 50kV MAGNUM® X-ray tube, MOXTEK Inc., in order to calibrate small solid dosimeters of alanine, tooth enamel and LiF-TLDs, commonly used in clinical quality assurance and datation dosimetry. METHODS:MAGIC-f polymer gel was kept ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735203
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4939255
更新日期:2016-02-01 00:00:00
abstract:PURPOSE:The primary objective of this work is to measure the secondary neutron field produced by an uncollimated proton pencil beam impinging on different tissue-equivalent phantom materials using organic scintillation detectors. Additionally, the Monte Carlo code mcnpx-PoliMi was used to simulate the detector response...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4963813
更新日期:2016-11-01 00:00:00
abstract:BACKGROUND:The rapid development and complexity of new x-ray computed tomography (CT) technologies and the need for evidence-based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. AIMS:This report offers updated testing guid...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13763
更新日期:2019-11-01 00:00:00
abstract::Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of pha...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2199987
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:The Small Animal Radiation Research Platform (SARRP) has been developed for conformal microirradiation with on-board cone beam CT (CBCT) guidance. The graphics processing unit (GPU)-accelerated Superposition-Convolution (SC) method for dose computation has been integrated into the treatment planning system (TPS...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12862
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as(99m)Tc or most positron emission tomography radiopharmaceuticals. METHODS:By evaluation of the resul...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4884035
更新日期:2014-07-01 00:00:00