A novel approach to neutron dosimetry.

Abstract:

PURPOSE:Having been overlooked for many years, research is now starting to take into account the directional distribution of neutron workplace fields. Existing neutron dosimetry instrumentation does not account for this directional distribution, resulting in conservative estimates of dose in neutron workplace fields (by around a factor of 2, although this is heavily dependent on the type of field). This conservatism could influence epidemiological studies on the health effects of radiation exposure. This paper reports on the development of an instrument which can estimate the effective dose of a neutron field, accounting for both the direction and the energy distribution. METHODS:A 6Li-loaded scintillator was used to perform neutron assays at a number of locations in a 20 × 20 × 17.5 cm3 water phantom. The variation in thermal and fast neutron response to different energies and field directions was exploited. The modeled response of the instrument to various neutron fields was used to train an artificial neural network (ANN) to learn the effective dose and ambient dose equivalent of these fields. All experimental data published in this work were measured at the National Physical Laboratory (UK). RESULTS:Experimental results were obtained for a number of radionuclide source based neutron fields to test the performance of the system. The results of experimental neutron assays at 25 locations in a water phantom were fed into the trained ANN. A correlation between neutron counting rates in the phantom and neutron fluence rates was experimentally found to provide dose rate estimates. A radionuclide source behind shadow cone was used to create a more complex field in terms of energy and direction. For all fields, the resulting estimates of effective dose rate were within 45% or better of their calculated values, regardless of energy distribution or direction for measurement times greater than 25 min. CONCLUSIONS:This work presents a novel, real-time, approach to workplace neutron dosimetry. It is believed that in the research presented in this paper, for the first time, a single instrument has been able to estimate effective dose.

journal_name

Med Phys

journal_title

Medical physics

authors

Balmer MJ,Gamage KA,Taylor GC

doi

10.1118/1.4964456

subject

Has Abstract

pub_date

2016-11-01 00:00:00

pages

5981

issue

11

eissn

0094-2405

issn

2473-4209

journal_volume

43

pub_type

杂志文章
  • SU-E-T-300: Monte Carlo Simulation of Single-Plane Magnetically Focused Narrow Proton Beams.

    abstract::Purpose To investigate narrow, elongated magnetically focused proton beams and compare their properties with passively collimated beams using Monte Carlo simulation. METHODS:We performed Geant4 Monte Carlo simulations involving a single quadrapole focusing magnet, thereby creating a flattened beam with an elongated e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735386

    authors: McAuley G,Barnes S,Wroe A,Slater J

    更新日期:2012-06-01 00:00:00

  • Learning-based automated segmentation of the carotid artery vessel wall in dual-sequence MRI using subdivision surface fitting.

    abstract:PURPOSE:The quantification of vessel wall morphology and plaque burden requires vessel segmentation, which is generally performed by manual delineations. The purpose of our work is to develop and evaluate a new 3D model-based approach for carotid artery wall segmentation from dual-sequence MRI. METHODS:The proposed me...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12476

    authors: Gao S,van 't Klooster R,Kitslaar PH,Coolen BF,van den Berg AM,Smits LP,Shahzad R,Shamonin DP,de Koning PJH,Nederveen AJ,van der Geest RJ

    更新日期:2017-10-01 00:00:00

  • Resin 90Y microsphere activity measurements for liver brachytherapy.

    abstract::The measurement of the radioactivity administered to the patient is one of the major components of 90Y microsphere liver brachytherapy. The activity of 90Y microspheres in a glass delivery vial was measured in a dose calibrator. The calibration value to use for 90Y in the dose calibrator was verified using an activity...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2731034

    authors: Dezarn WA,Kennedy AS

    更新日期:2007-06-01 00:00:00

  • Dosimetric parameters for three low-energy brachytherapy sources using the Monte Carlo N-particle code.

    abstract::Monte Carlo calculations have been performed for the purpose of characterizing the dosimetric properties of three brachytherapy sources. The three sources are manufactured by Syncor Pharmaceuticals Inc. and consist of two 125I seeds (BT-125-1 and BT-125-2) and one 103Pd seed (BT-103-3). The BT-125-1 and BT-125-2 seed ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1469627

    authors: DeMarco JJ,Hugo G,Solberg TD

    更新日期:2002-05-01 00:00:00

  • Micro-angiography for neuro-vascular imaging. II. Cascade model analysis.

    abstract::A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1617550

    authors: Ganguly A,Rudin S,Bednarek DR,Hoffmann KR

    更新日期:2003-11-01 00:00:00

  • Improved modeling of multiple scattering in the Voxel Monte Carlo model.

    abstract::The implementation of an improved model for multiple scattering into the-Voxel Monte Carlo (VMC) algorithm for fast electron dose calculation in radiation therapy is presented. The model takes into account path-length corrections (PLC) and lateral displacement in the individual electron steps. The extraction of the sc...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.597933

    authors: Kawrakow I

    更新日期:1997-04-01 00:00:00

  • Effect of respiratory motion on the delivery of breast radiotherapy using SMLC intensity modulation.

    abstract::This study evaluates the effects of respiratory motion on breast radiotherapy delivered using segmented multileaf collimator (SMLC) intensity modulation. An anthropomorphic breast phantom was constructed of polystyrene plates between which radiographic films were inserted. The phantom was mounted on a moving platform ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2405323

    authors: Liu Q,McDermott P,Burmeister J

    更新日期:2007-01-01 00:00:00

  • Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans.

    abstract::Computer-aided diagnostic (CAD) schemes have been developed to assist radiologists in the early detection of lung cancer in radiographs and computed tomography (CT) images. In order to improve sensitivity for nodule detection, many researchers have employed a filter as a preprocessing step for enhancement of nodules. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.1581411

    authors: Li Q,Sone S,Doi K

    更新日期:2003-08-01 00:00:00

  • Performance characteristics of A 150 plastic-equivalent gases in A 150 plastic proportional counters for 14.8-MeV neutrons.

    abstract::Two recently developed A 150 plastic-equivalent gas mixtures have been tested for suitability in proportional counter applications. Methane- and propane-based "tissue-equivalent" gases were also included for comparison purposes. Event-size weighted dose distributions were measured in a 14.8-MeV neutron beam. Resolutio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.595536

    authors: DeLuca PM Jr,Schell MC,Pearson DW,Higgins PD,Attix FH

    更新日期:1984-07-01 00:00:00

  • Computerized detection of lung nodules through radiomics.

    abstract:PURPOSE:Lung cancer is a major cause of cancer deaths, and the 5-year survival rate of stage IV lung cancer patients is only 2%. However, the 5-year survival rate of stage I lung cancer patients significantly increases to 50%. As such, spiral computed tomography (CT) scans are necessary to diagnose high-risk lung cance...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12331

    authors: Ma J,Zhou Z,Ren Y,Xiong J,Fu L,Wang Q,Zhao J

    更新日期:2017-08-01 00:00:00

  • Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy.

    abstract:PURPOSE:Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4800802

    authors: Richter D,Schwarzkopf A,Trautmann J,Krämer M,Durante M,Jäkel O,Bert C

    更新日期:2013-05-01 00:00:00

  • Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging.

    abstract:PURPOSE:To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. M...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4964454

    authors: Schlosser J,Gong RH,Bruder R,Schweikard A,Jang S,Henrie J,Kamaya A,Koong A,Chang DT,Hristov D

    更新日期:2016-11-01 00:00:00

  • 4D rotational x-ray imaging of wrist joint dynamic motion.

    abstract::Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2000647

    authors: Carelsen B,Bakker NH,Strackee SD,Boon SN,Maas M,Sabczynski J,Grimbergen CA,Streekstra GJ

    更新日期:2005-09-01 00:00:00

  • Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo-based MRI.

    abstract:PURPOSE:In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* es...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.12318

    authors: Fatnassi C,Boucenna R,Zaidi H

    更新日期:2017-07-01 00:00:00

  • Effect of lateral boundaries on contrast functions in time-resolved transillumination measurements.

    abstract::The method of images is employed to insert the effects of the presence of a single lateral boundary on contrast functions previously derived for an infinite slab using a random walk model of photon transport. The predictions of the model for zero and extrapolated boundary conditions are compared with Monte Carlo (MC) ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598687

    authors: Chernomordik V,Gandjbakhche AH,Hebden JC,Zaccanti G

    更新日期:1999-09-01 00:00:00

  • Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation.

    abstract:PURPOSE:Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality a...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4812429

    authors: Driscoll B,Keller H,Jaffray D,Coolens C

    更新日期:2013-08-01 00:00:00

  • Comparisons of treatment optimization directly incorporating systematic patient setup uncertainty with a margin-based approach.

    abstract:PURPOSE:To develop a probabilistic treatment planning (PTP) method which is robust to systematic patient setup errors and to compare PTP plans with plans generated using a planning target volume (PTV) margin optimized to give the same target coverage probability as the PTP plan. METHODS:Plans adhering to the RTOG-0126...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3679856

    authors: Moore JA,Gordon JJ,Anscher M,Silva J,Siebers JV

    更新日期:2012-02-01 00:00:00

  • SPECT imaging of high energy isotopes and isotopes with high energy contaminants with rotating slat collimators.

    abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3177312

    authors: Van Holen R,Staelens S,Vandenberghe S

    更新日期:2009-09-01 00:00:00

  • Designing an optical distance indicator for a radiation therapy accelerator.

    abstract::The computational aspects of the design of an optical distance indicator (ODI) for use with a radiation therapy accelerator are discussed. The specifics of the optical and mechanical design of an ODI for use with a superconducting cyclotron used for fast neutron therapy are presented. ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.598510

    authors: Maughan RL

    更新日期:1999-02-01 00:00:00

  • On the assay of brachytherapy sources.

    abstract::In many of brachytherapy procedures, a large amount of radioactive sources are used to deliver desired doses to the target volume. It is both the federal regulation recommendation (U.S. Nuclear Regulatory Commission, 10 CFR 35.432) and recommendations of the American Association of Physicists in Medicine (AAPM) [Kutch...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2734723

    authors: Yue NJ,Haffty BG,Yue J

    更新日期:2007-06-01 00:00:00

  • The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator.

    abstract::The geometric accuracy and precision of an image-guided treatment system were assessed. Image guidance is performed using an x-ray volume imaging (XVI) system integrated with a linear accelerator and treatment planning system. Using an amorphous silicon detector and x-ray tube, volumetric computed tomography images ar...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2143141

    authors: Sharpe MB,Moseley DJ,Purdie TG,Islam M,Siewerdsen JH,Jaffray DA

    更新日期:2006-01-01 00:00:00

  • The Jacobian as a measure of planar dose congruence.

    abstract::We propose a new starting point for comparing planar dose distributions using a Jacobian-based measure. The measure is normalization independent, i.e., is sensitive to dose patterns while not being biased by global dose scaling. The measure is free of tunable parameters and is bounded between zero and one. We also pro...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2982136

    authors: Paniak LD,Charland PM

    更新日期:2008-11-01 00:00:00

  • Multiscale entropy of laser Doppler flowmetry signals in healthy human subjects.

    abstract:PURPOSE:The cardiovascular system (CVS) regulation can be studied from a central viewpoint, through heart rate variability (HRV) data, and from a peripheral viewpoint, through laser Doppler flowmetry (LDF) signals. Both the central and peripheral CVSs are regulated by several interacting mechanisms, each having its own...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3512796

    authors: Humeau A,Buard B,Mahé G,Rousseau D,Chapeau-Blondeau F,Abraham P

    更新日期:2010-12-01 00:00:00

  • SU-E-T-96: Energy Dependence of the New GafChromic- EBT3 Film's Dose Response-Curve.

    abstract:PURPOSE:To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolution. METHODS:Two sets of EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6MV, 15MV and 50kV) at 8 dose values (50-3200cGy). The megavoltage beams...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735153

    authors: Chiu-Tsao S,Massillon-Jl G,Domingo-Muñoz I,Chan M

    更新日期:2012-06-01 00:00:00

  • Vision 20/20: Mammographic breast density and its clinical applications.

    abstract::Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which wome...

    journal_title:Medical physics

    pub_type: 杂志文章,评审

    doi:10.1118/1.4935141

    authors: Ng KH,Lau S

    更新日期:2015-12-01 00:00:00

  • A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration.

    abstract:PURPOSE:In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. How...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.3697524

    authors: Hub M,Thieke C,Kessler ML,Karger CP

    更新日期:2012-04-01 00:00:00

  • TU-E-217BCD-07: Pilot Study on Consistency in Size Metrics for a Multimodality PEM/MR Breast Imaging Approach.

    abstract:PURPOSE:In this study, we evaluated the degree of consistency between size metrics obtained from PEM and MRI to determine the intrinsic effectiveness of a multimodality approach using these two systems for breast imaging. METHODS:Under an IRB-approved protocol, 42 cases were considered (16 patients with 28 lesions), e...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4735979

    authors: Sadinski M,Giger M,Drukker K,Yamaguchi K,Lan L,Li H

    更新日期:2012-06-01 00:00:00

  • Treatment planning system and beam data validation for the ZAP-X: a novel self-shielded stereotactic radiosurgery system.

    abstract:PURPOSE:To evaluate the treatment planning system (TPS) performance of the ZAP-X stereotactic radiosurgery (SRS) system through nondosimetric, dosimetric, and end-to-end (E2E) tests. METHODS:A comprehensive set of TPS commissioning and validation tests were developed using published guidelines. Nondosimetric validatio...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1002/mp.14740

    authors: Srivastava SP,Jani SS,Pinnaduwage DS,Yan X,Rogers L,Barranco FD,Barani IJ,Sorensen S

    更新日期:2021-01-28 00:00:00

  • Radiative transport in the delta-P1 approximation for semi-infinite turbid media.

    abstract::We have developed an analytic solution for spatially resolved diffuse reflectance within the deltaP1 approximation to the radiative transport equation for a semi-infinite homogeneous turbid medium. We evaluate the performance of this solution by comparing its predictions with those provided by Monte Carlo simulations ...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.2828184

    authors: Seo I,Hayakawa CK,Venugopalan V

    更新日期:2008-02-01 00:00:00

  • Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatments using on-treatment EPID images and a model-based forward-calculation algorithm.

    abstract:PURPOSE:Radiation treatments are trending toward delivering higher doses per fraction under stereotactic radiosurgery and hypofractionated treatment regimens. There is a need for accurate 3D in vivo patient dose verification using electronic portal imaging device (EPID) measurements. This work presents a model-based te...

    journal_title:Medical physics

    pub_type: 杂志文章

    doi:10.1118/1.4935199

    authors: Van Uytven E,Van Beek T,McCowan PM,Chytyk-Praznik K,Greer PB,McCurdy BM

    更新日期:2015-12-01 00:00:00