A MEMS-based flexible multichannel ECoG-electrode array.

Abstract:

:We present a micromachined 252-channel ECoG (electrocorticogram)-electrode array, which is made of a thin polyimide foil substrate enclosing sputtered platinum electrode sites and conductor paths. The array subtends an area of approximately 35 mm by 60 mm and is designed to cover large parts of a hemisphere of a macaque monkey's cortex. Eight omnetics connectors are directly soldered to the foil. This leads to a compact assembly size which enables a chronic implantation of the array and allows free movements of the animal between the recording sessions. The electrode sites are 1 mm in diameter and were characterized by electrochemical impedance spectroscopy. At 1 kHz, the electrode impedances vary between 1.5 kOmega and 5 kOmega. The yield of functioning electrodes in three assembled devices is 99.5%. After implantation of a device with 100% working electrodes, standard electrocorticographic signals can be obtained from every electrode. The response to visual stimuli can be measured with electrodes lying on the visual cortex. After an implantation time of 4.5 months, all electrodes are still working and no decline in signal quality could be observed.

journal_name

J Neural Eng

authors

Rubehn B,Bosman C,Oostenveld R,Fries P,Stieglitz T

doi

10.1088/1741-2560/6/3/036003

subject

Has Abstract

pub_date

2009-06-01 00:00:00

pages

036003

issue

3

eissn

1741-2560

issn

1741-2552

pii

S1741-2560(09)09160-5

journal_volume

6

pub_type

杂志文章
  • Facilitating stochastic resonance as a pre-emphasis method for neural spike detection.

    abstract:OBJECTIVE:We aim to increase the number of neural spikes that can be detected in a single channel extracellular neural recording. APPROACH:We propose a pre-emphasis method facilitating stochastic resonance (SR), where we introduce the band-pass-filtered noisy extracellular recording to an overdamped Brownian particle ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abae8a

    authors: Güngör CB,Töreyin H

    更新日期:2020-09-18 00:00:00

  • Concurrent control of a brain-computer interface and natural overt movements.

    abstract:OBJECTIVE:A primary control signal in brain-computer interfaces (BCIs) have been cortical signals related to movement. However, in cases where natural motor function remains, BCI control signals may interfere with other possibly simultaneous activity for useful ongoing movement. We sought to determine if the brain coul...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aadf3d

    authors: Bashford L,Wu J,Sarma D,Collins K,Rao RPN,Ojemann JG,Mehring C

    更新日期:2018-12-01 00:00:00

  • Transparent, low-autofluorescence microECoG device for simultaneous Ca2+ imaging and cortical electrophysiology in vivo.

    abstract:OBJECTIVE:Multimodal neuroimaging approaches are beneficial to discover brain functionalities at high spatial and temporal resolution. In our work, a novel material composition of a microECoG device relying on Parylene HT and indium-tin-oxide (ITO) is presented, which facilitates two-photon imaging of Ca2+ signals and ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab603f

    authors: Zátonyi A,Madarász M,Szabó Á,Lőrincz T,Hodován R,Rózsa B,Fekete Z

    更新日期:2020-02-18 00:00:00

  • The noise and impedance of microelectrodes.

    abstract:OBJECTIVE:While the positive correlation between impedance and noise of microelectrodes is well known, their quantitative relationship is too rarely described. Knowledge of this relationship provides useful information for both microsystems engineers and electrophysiologists. APPROACH:We discuss the physical basis of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb3b4

    authors: Mierzejewski M,Steins H,Kshirsagar P,Jones PD

    更新日期:2020-10-15 00:00:00

  • Suppression of scarring in peripheral nerve implants by drug elution.

    abstract:OBJECTIVE:Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progres...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026006

    authors: FitzGerald JJ

    更新日期:2016-04-01 00:00:00

  • Creation of virtual channels in the retina using synchronous and asynchronous stimulation - a modelling study.

    abstract:OBJECTIVE:Implantable retinal prostheses aim to provide artificial vision to those suffering from retinal degenerative diseases by electrically stimulating the remaining retinal neurons using a multi-electrode array. The spatial resolution of these devices can be improved by creation of so-called virtual channels (VCs)...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abc3a9

    authors: Song X,Guo T,Shivdasani MN,Dokos S,Lovell NH,Li X,Qiu S,Li T,Zheng S,Li L

    更新日期:2020-10-21 00:00:00

  • DataHigh: graphical user interface for visualizing and interacting with high-dimensional neural activity.

    abstract:OBJECTIVE:Analyzing and interpreting the activity of a heterogeneous population of neurons can be challenging, especially as the number of neurons, experimental trials, and experimental conditions increases. One approach is to extract a set of latent variables that succinctly captures the prominent co-fluctuation patte...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/6/066012

    authors: Cowley BR,Kaufman MT,Butler ZS,Churchland MM,Ryu SI,Shenoy KV,Yu BM

    更新日期:2013-12-01 00:00:00

  • Autoencoders for learning template spectrograms in electrocorticographic signals.

    abstract:OBJECTIVE:Electrocorticography (ECoG) based studies generally analyze features from specific frequency bands selected by manual evaluation of spectral power. However, the definition of these features can vary across subjects, cortical areas, tasks and across time for a given subject. We propose an autoencoder based app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf13f

    authors: Pailla T,Miller KJ,Gilja V

    更新日期:2019-02-01 00:00:00

  • An overview of adaptive model theory: solving the problems of redundancy, resources, and nonlinear interactions in human movement control.

    abstract::Adaptive model theory (AMT) is a computational theory that addresses the difficult control problem posed by the musculoskeletal system in interaction with the environment. It proposes that the nervous system creates motor maps and task-dependent synergies to solve the problems of redundancy and limited central resourc...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/2/3/S10

    authors: Neilson PD,Neilson MD

    更新日期:2005-09-01 00:00:00

  • In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes.

    abstract:OBJECTIVE:Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba560

    authors: Shivdasani MN,Evans M,Burns O,Yeoh J,Allen PJ,Nayagam DAX,Villalobos J,Abbott CJ,Luu CD,Opie NL,Sabu A,Saunders AL,McPhedran M,Cardamone L,McGowan C,Maxim V,Williams RA,Fox KE,Cicione R,Garrett DJ,Ahnood A,Ganes

    更新日期:2020-08-05 00:00:00

  • Influence of field of view in visual prostheses design: Analysis with a VR system.

    abstract:OBJECTIVE:Visual prostheses are designed to restore partial functional vision in patients with total vision loss. Retinal visual prostheses provide limited capabilities as a result of low resolution, limited field of view and poor dynamic range. Understanding the influence of these parameters in the perception results ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb9be

    authors: Sanchez-Garcia M,Martinez-Cantin R,Bermudez-Cameo J,Guerrero JJ

    更新日期:2020-10-08 00:00:00

  • Natural language processing with dynamic classification improves P300 speller accuracy and bit rate.

    abstract::The P300 speller is an example of a brain-computer interface that can restore functionality to victims of neuromuscular disorders. Although the most common application of this system has been communicating language, the properties and constraints of the linguistic domain have not to date been exploited when decoding b...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/1/016004

    authors: Speier W,Arnold C,Lu J,Taira RK,Pouratian N

    更新日期:2012-02-01 00:00:00

  • Influence of proprioceptive feedback on the firing rate and recruitment of motoneurons.

    abstract::We investigated the relationships of the firing rate and maximal recruitment threshold of motoneurons recorded during isometric contraction with the number of spindles in individual muscles. At force levels above 10% of maximal voluntary contraction, the firing rate was inversely related to the number of spindles in a...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/1/016007

    authors: De Luca CJ,Kline JC

    更新日期:2012-02-01 00:00:00

  • Toward the development of a color visual prosthesis.

    abstract::All of the human prosthetic visual systems implanted so far have been achromatic. Schmidt et al. (1996) reported that at low stimulation intensities their subject reported that phosphenes usually had a specific hue, but when the stimulus intensity was increased, they desaturated to white. We speculate here that previo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd520

    authors: Towle V,Pham T,McCaffrey M,Allen D,Troyk PR

    更新日期:2020-12-18 00:00:00

  • A novel flexible cuff-like microelectrode for dual purpose, acute and chronic electrical interfacing with the mouse cervical vagus nerve.

    abstract:OBJECTIVE:Neural reflexes regulate immune responses and homeostasis. Advances in bioelectronic medicine indicate that electrical stimulation of the vagus nerve can be used to treat inflammatory disease, yet the understanding of neural signals that regulate inflammation is incomplete. Current interfaces with the vagus n...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa7a42

    authors: Caravaca AS,Tsaava T,Goldman L,Silverman H,Riggott G,Chavan SS,Bouton C,Tracey KJ,Desimone R,Boyden ES,Sohal HS,Olofsson PS

    更新日期:2017-12-01 00:00:00

  • Multiband tangent space mapping and feature selection for classification of EEG during motor imagery.

    abstract:OBJECTIVE:When designing multiclass motor imagery-based brain-computer interface (MI-BCI), a so-called tangent space mapping (TSM) method utilizing the geometric structure of covariance matrices is an effective technique. This paper aims to introduce a method using TSM for finding accurate operational frequency bands r...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aac313

    authors: Islam MR,Tanaka T,Molla MKI

    更新日期:2018-08-01 00:00:00

  • Spatial and temporal variability in response to hybrid electro-optical stimulation.

    abstract::Hybrid electro-optical neural stimulation is a novel paradigm combining the advantages of optical and electrical stimulation techniques while reducing their respective limitations. However, in order to fulfill its promise, this technique requires reduced variability and improved reproducibility. Here we used a compara...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036003

    authors: Duke AR,Lu H,Jenkins MW,Chiel HJ,Jansen ED

    更新日期:2012-06-01 00:00:00

  • A non-parametric method for automatic neural spike clustering based on the non-uniform distribution of the data.

    abstract::In this paper, we propose a simple and straightforward algorithm for neural spike sorting. The algorithm is based on the observation that the distribution of a neural signal largely deviates from the uniform distribution and is rather unimodal. The detected spikes to be sorted are first processed with some feature ext...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/6/066014

    authors: Tiganj Z,Mboup M

    更新日期:2011-12-01 00:00:00

  • Ten-dimensional anthropomorphic arm control in a human brain-machine interface: difficulties, solutions, and limitations.

    abstract:OBJECTIVE:In a previous study we demonstrated continuous translation, orientation and one-dimensional grasping control of a prosthetic limb (seven degrees of freedom) by a human subject with tetraplegia using a brain-machine interface (BMI). The current study, in the same subject, immediately followed the previous work...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/1/016011

    authors: Wodlinger B,Downey JE,Tyler-Kabara EC,Schwartz AB,Boninger ML,Collinger JL

    更新日期:2015-02-01 00:00:00

  • Functional consequences of model complexity in rhythmic systems: II. Systems performance of model and hybrid oscillators.

    abstract::Neural models are increasingly being used as design components of physical systems. In order to best use models in these novel contexts, we must develop design rules that describe how decisions in model construction relate to the functional performance of the resulting system. In the accompanying paper, we described a...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/4/3/003

    authors: Sorensen ME,DeWeerth SP

    更新日期:2007-09-01 00:00:00

  • Dilation of the oropharynx via selective stimulation of the hypoglossal nerve.

    abstract::The functional effects of selective hypoglossal nerve (HG) stimulation with a multi-contact peripheral nerve electrode were assessed using images of the upper airways and the tongue in anesthetized beagles. A biphasic pulse train of 50 Hz frequency and 2 s duration was applied through each one of the tripolar contact ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/2/4/002

    authors: Huang J,Sahin M,Durand DM

    更新日期:2005-12-01 00:00:00

  • An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up.

    abstract::We present the results of a 5-year patient follow-up after implantation of an original neuroprosthesis. The system is able to stimulate both epimysial and neural electrodes in such a way that the complete flexor-extensor chain of the lower limb can be activated without using the withdrawal reflex. We demonstrate that ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/3/4/003

    authors: Guiraud D,Stieglitz T,Koch KP,Divoux JL,Rabischong P

    更新日期:2006-12-01 00:00:00

  • In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

    abstract::After extended implantation times, traditional intracortical neural probes exhibit a foreign-body reaction characterized by a reactive glial sheath that has been associated with increased system impedance and signal deterioration. Previously, we have proposed that the local in vivo polymerization of an electronically ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/2/026005

    authors: Ouyang L,Shaw CL,Kuo CC,Griffin AL,Martin DC

    更新日期:2014-04-01 00:00:00

  • Assessment of gliosis around moveable implants in the brain.

    abstract::Repositioning microelectrodes post-implantation is emerging as a promising approach to achieve long-term reliability in single neuronal recordings. The main goal of this study was to (a) assess glial reaction in response to movement of microelectrodes in the brain post-implantation and (b) determine an optimal window ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/4/046004

    authors: Stice P,Muthuswamy J

    更新日期:2009-08-01 00:00:00

  • Different classification techniques considering brain computer interface applications.

    abstract::In this work the application of different machine learning techniques for classification of mental tasks from electroencephalograph (EEG) signals is investigated. The main application for this research is the improvement of brain computer interface (BCI) systems. For this purpose, Bayesian graphical network, neural ne...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/3/2/008

    authors: Rezaei S,Tavakolian K,Nasrabadi AM,Setarehdan SK

    更新日期:2006-06-01 00:00:00

  • Pavlovian control of intraspinal microstimulation to produce over-ground walking.

    abstract:OBJECTIVE:Neuromodulation technologies are increasingly used for improving function after neural injury. To achieve a symbiotic relationship between device and user, the device must augment remaining function, and independently adapt to day-to-day changes in function. The goal of this study was to develop predictive co...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8e8e

    authors: Dalrymple AN,Roszko DA,Sutton RS,Mushahwar VK

    更新日期:2020-06-02 00:00:00

  • Analysis of spontaneous MEG activity in mild cognitive impairment and Alzheimer's disease using spectral entropies and statistical complexity measures.

    abstract::Alzheimer's disease (AD) is the most common cause of dementia. Over the last few years, a considerable effort has been devoted to exploring new biomarkers. Nevertheless, a better understanding of brain dynamics is still required to optimize therapeutic strategies. In this regard, the characterization of mild cognitive...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036007

    authors: Bruña R,Poza J,Gómez C,García M,Fernández A,Hornero R

    更新日期:2012-06-01 00:00:00

  • Coarse behavioral context decoding.

    abstract:OBJECTIVE:Current brain-computer interface (BCI) studies demonstrate the potential to decode neural signals obtained from structured and trial-based tasks to drive actuators with high performance within the context of these tasks. Ideally, to maximize utility, such systems will be applied to a wide range of behavioral ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaee9c

    authors: Alasfour A,Gabriel P,Jiang X,Shamie I,Melloni L,Thesen T,Dugan P,Friedman D,Doyle W,Devinsky O,Gonda D,Sattar S,Wang S,Halgren E,Gilja V

    更新日期:2019-02-01 00:00:00

  • Brain-actuated gait trainer with visual and proprioceptive feedback.

    abstract:OBJECTIVE:Brain-machine interfaces (BMIs) have been proposed in closed-loop applications for neuromodulation and neurorehabilitation. This study describes the impact of different feedback modalities on the performance of an EEG-based BMI that decodes motor imagery (MI) of leg flexion and extension. APPROACH:We execute...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa7df9

    authors: Liu D,Chen W,Lee K,Chavarriaga R,Bouri M,Pei Z,Del R Millán J

    更新日期:2017-10-01 00:00:00

  • Myoelectric control with abstract decoders.

    abstract:OBJECTIVE:The objective of this study was to compare the use of muscles appropriate for partial-hand prostheses with those typically used for complete hand devices and to determine whether differences in their underlying neural substrates translate to different levels of myoelectric control. APPROACH:We developed a no...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aacbfe

    authors: Dyson M,Barnes J,Nazarpour K

    更新日期:2018-10-01 00:00:00