Brain-actuated gait trainer with visual and proprioceptive feedback.

Abstract:

OBJECTIVE:Brain-machine interfaces (BMIs) have been proposed in closed-loop applications for neuromodulation and neurorehabilitation. This study describes the impact of different feedback modalities on the performance of an EEG-based BMI that decodes motor imagery (MI) of leg flexion and extension. APPROACH:We executed experiments in a lower-limb gait trainer (the legoPress) where nine able-bodied subjects participated in three consecutive sessions based on a crossover design. A random forest classifier was trained from the offline session and tested online with visual and proprioceptive feedback, respectively. Post-hoc classification was conducted to assess the impact of feedback modalities and learning effect (an improvement over time) on the simulated trial-based performance. Finally, we performed feature analysis to investigate the discriminant power and brain pattern modulations across the subjects. MAIN RESULTS:(i) For real-time classification, the average accuracy was [Formula: see text]% and [Formula: see text]% for the two online sessions. The results were significantly higher than chance level, demonstrating the feasibility to distinguish between MI of leg extension and flexion. (ii) For post-hoc classification, the performance with proprioceptive feedback ([Formula: see text]%) was significantly better than with visual feedback ([Formula: see text]%), while there was no significant learning effect. (iii) We reported individual discriminate features and brain patterns associated to each feedback modality, which exhibited differences between the two modalities although no general conclusion can be drawn. SIGNIFICANCE:The study reported a closed-loop brain-controlled gait trainer, as a proof of concept for neurorehabilitation devices. We reported the feasibility of decoding lower-limb movement in an intuitive and natural way. As far as we know, this is the first online study discussing the role of feedback modalities in lower-limb MI decoding. Our results suggest that proprioceptive feedback has an advantage over visual feedback, which could be used to improve robot-assisted strategies for motor training and functional recovery.

journal_name

J Neural Eng

authors

Liu D,Chen W,Lee K,Chavarriaga R,Bouri M,Pei Z,Del R Millán J

doi

10.1088/1741-2552/aa7df9

subject

Has Abstract

pub_date

2017-10-01 00:00:00

pages

056017

issue

5

eissn

1741-2560

issn

1741-2552

journal_volume

14

pub_type

杂志文章
  • Accuracy assessment of CKC high-density surface EMG decomposition in biceps femoris muscle.

    abstract::The aim of this study was to assess the accuracy of the convolution kernel compensation (CKC) method in decomposing high-density surface EMG (HDsEMG) signals from the pennate biceps femoris long-head muscle. Although the CKC method has already been thoroughly assessed in parallel-fibered muscles, there are several fac...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/6/066002

    authors: Marateb HR,McGill KC,Holobar A,Lateva ZC,Mansourian M,Merletti R

    更新日期:2011-12-01 00:00:00

  • Inclusion of temporal priors for automated neonatal EEG classification.

    abstract::The aim of this paper is to use recent advances in the clinical understanding of the temporal evolution of seizure burden in neonates with hypoxic ischemic encephalopathy to improve the performance of automated detection algorithms. Probabilistic weights are designed from temporal locations of neonatal seizure events ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/4/046002

    authors: Temko A,Stevenson N,Marnane W,Boylan G,Lightbody G

    更新日期:2012-08-01 00:00:00

  • Continuous neuronal ensemble control of simulated arm reaching by a human with tetraplegia.

    abstract::Functional electrical stimulation (FES), the coordinated electrical activation of multiple muscles, has been used to restore arm and hand function in people with paralysis. User interfaces for such systems typically derive commands from mechanically unrelated parts of the body with retained volitional control, and are...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/3/034003

    authors: Chadwick EK,Blana D,Simeral JD,Lambrecht J,Kim SP,Cornwell AS,Taylor DM,Hochberg LR,Donoghue JP,Kirsch RF

    更新日期:2011-06-01 00:00:00

  • Symbolic time series analysis of fNIRS signals in brain development assessment.

    abstract:OBJECTIVE:Assessing an infant's brain development remains a challenge for neuroscientists and pediatricians despite great technological advances. As a non-invasive neuroimaging tool, functional near-infrared spectroscopy (fNIRS) has great advantages in monitoring an infant's brain activity. To explore the dynamic featu...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aae0c9

    authors: Liang Z,Minagawa Y,Yang HC,Tian H,Cheng L,Arimitsu T,Takahashi T,Tong Y

    更新日期:2018-12-01 00:00:00

  • A neurorobotic platform for locomotor prosthetic development in rats and mice.

    abstract:OBJECTIVES:We aimed to develop a robotic interface capable of providing finely-tuned, multidirectional trunk assistance adjusted in real-time during unconstrained locomotion in rats and mice. APPROACH:We interfaced a large-scale robotic structure actuated in four degrees of freedom to exchangeable attachment modules e...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026007

    authors: von Zitzewitz J,Asboth L,Fumeaux N,Hasse A,Baud L,Vallery H,Courtine G

    更新日期:2016-04-01 00:00:00

  • Biophysically realistic neuron models for simulation of cortical stimulation.

    abstract:OBJECTIVE:We implemented computational models of human and rat cortical neurons for simulating the neural response to cortical stimulation with electromagnetic fields. APPROACH:We adapted model neurons from the library of Blue Brain models to reflect biophysical and geometric properties of both adult rat and human cor...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aadbb1

    authors: Aberra AS,Peterchev AV,Grill WM

    更新日期:2018-12-01 00:00:00

  • A MEMS-based flexible multichannel ECoG-electrode array.

    abstract::We present a micromachined 252-channel ECoG (electrocorticogram)-electrode array, which is made of a thin polyimide foil substrate enclosing sputtered platinum electrode sites and conductor paths. The array subtends an area of approximately 35 mm by 60 mm and is designed to cover large parts of a hemisphere of a macaq...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/3/036003

    authors: Rubehn B,Bosman C,Oostenveld R,Fries P,Stieglitz T

    更新日期:2009-06-01 00:00:00

  • Neural engineering: the process, applications, and its role in the future of medicine.

    abstract:OBJECTIVE:Recent advances in neural engineering have restored mobility to people with paralysis, relieved symptoms of movement disorders, reduced chronic pain, restored the sense of hearing, and provided sensory perception to individuals with sensory deficits. APPROACH:This progress was enabled by the team-based, inte...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/ab4869

    authors: Ereifej ES,Shell CE,Schofield JS,Charkhkar H,Cuberovic I,Dorval AD,Graczyk EL,Kozai TDY,Otto KJ,Tyler DJ,Welle CG,Widge AS,Zariffa J,Moritz CT,Bourbeau DJ,Marasco PD

    更新日期:2019-11-12 00:00:00

  • Algorithms and architectures for low power spike detection and alignment.

    abstract::We introduce algorithms and architectures for automatic spike detection and alignment that are designed for low power. Some of the algorithms are based on principal component analysis (PCA). Others employ a novel integral transform analysis and achieve 99% of the precision of a PCA detector, while requiring only 0.05%...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/3/1/004

    authors: Zviagintsev A,Perelman Y,Ginosar R

    更新日期:2006-03-01 00:00:00

  • Modeling deep brain stimulation: point source approximation versus realistic representation of the electrode.

    abstract::Deep brain stimulation (DBS) has emerged as an effective treatment for movement disorders; however, the fundamental mechanisms by which DBS works are not well understood. Computational models of DBS can provide insights into these fundamental mechanisms and typically require two steps: calculation of the electrical po...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/6/066009

    authors: Zhang TC,Grill WM

    更新日期:2010-12-01 00:00:00

  • Spatial channel interactions in cochlear implants.

    abstract::The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies g...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046029

    authors: Tang Q,Benítez R,Zeng FG

    更新日期:2011-08-01 00:00:00

  • Different classification techniques considering brain computer interface applications.

    abstract::In this work the application of different machine learning techniques for classification of mental tasks from electroencephalograph (EEG) signals is investigated. The main application for this research is the improvement of brain computer interface (BCI) systems. For this purpose, Bayesian graphical network, neural ne...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/3/2/008

    authors: Rezaei S,Tavakolian K,Nasrabadi AM,Setarehdan SK

    更新日期:2006-06-01 00:00:00

  • The response of retinal neurons to high-frequency stimulation.

    abstract:OBJECTIVE:High-rate pulse trains have proven to be effective in cochlear prosthetics and, more recently, have been shown to elicit a wide range of interesting response properties in axons of the peripheral nervous system. Surprisingly, the effectiveness of such trains for use in retinal prostheses has not been explored...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/3/036009

    authors: Cai C,Twyford P,Fried S

    更新日期:2013-06-01 00:00:00

  • The statistical distribution of noisy transmission in human sensors.

    abstract:OBJECTIVE:Brains, like other physical devices, are inherently noisy. This source of variability is large, to the extent that internal noise often impacts human sensory processing more than externally induced (stimulus-driven) perturbations. Despite the fundamental nature of this phenomenon, its statistical distribution...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1741-2560/10/1/016014

    authors: Neri P

    更新日期:2013-02-01 00:00:00

  • A combination strategy based brain-computer interface for two-dimensional movement control.

    abstract:OBJECTIVE:Two-dimensional (2D) movement control is an important issue in brain-computer interfaces (BCIs) research because being able to move, for example, a cursor with the brain will enable patients with motor disabilities to control their environment. However, it is still a challenge to continuously control 2D movem...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/4/046021

    authors: Xia B,Maysam O,Veser S,Cao L,Li J,Jia J,Xie H,Birbaumer N

    更新日期:2015-08-01 00:00:00

  • Accurate identification of motor unit discharge patterns from high-density surface EMG and validation with a novel signal-based performance metric.

    abstract:OBJECTIVE:A signal-based metric for assessment of accuracy of motor unit (MU) identification from high-density surface electromyograms (EMG) is introduced. This metric, so-called pulse-to-noise-ratio (PNR), is computationally efficient, does not require any additional experimental costs and can be applied to every MU t...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/1/016008

    authors: Holobar A,Minetto MA,Farina D

    更新日期:2014-02-01 00:00:00

  • Multi-class EEG classification of voluntary hand movement directions.

    abstract:OBJECTIVE:Studies have shown that low frequency components of brain recordings provide information on voluntary hand movement directions. However, non-invasive techniques face more challenges compared to invasive techniques. APPROACH:This study presents a novel signal processing technique to extract features from non-...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/5/056018

    authors: Robinson N,Guan C,Vinod AP,Ang KK,Tee KP

    更新日期:2013-10-01 00:00:00

  • Toward a hybrid brain-computer interface based on imagined movement and visual attention.

    abstract::Brain-computer interface (BCI) systems do not work for all users. This article introduces a novel combination of tasks that could inspire BCI systems that are more accurate than conventional BCIs, especially for users who cannot attain accuracy adequate for effective communication. Subjects performed tasks typically u...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/2/026007

    authors: Allison BZ,Brunner C,Kaiser V,Müller-Putz GR,Neuper C,Pfurtscheller G

    更新日期:2010-04-01 00:00:00

  • Hardware architecture for real-time EEG-based functional brain connectivity parameter extraction.

    abstract::In this work, we proposed a novel architecture for real-time quantitative characterization of functional brain connectivity networks derived from Electroencephalogram (EEG). It consists of two main parts - calculation of Phase Lag Index (PLI) to form the functional connectivity networks and the extraction of a set of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd462

    authors: Gutierrez Nuno RA,Chung CHR,Maharatna K

    更新日期:2020-12-16 00:00:00

  • Integrated circuit amplifiers for multi-electrode intracortical recording.

    abstract::Significant progress has been made in systems that interpret the electrical signals of the brain in order to control an actuator. One version of these systems senses neuronal extracellular action potentials with an array of up to 100 miniature probes inserted into the cortex. The impedance of each probe is high, so en...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/1/012001

    authors: Jochum T,Denison T,Wolf P

    更新日期:2009-02-01 00:00:00

  • Dilation of the oropharynx via selective stimulation of the hypoglossal nerve.

    abstract::The functional effects of selective hypoglossal nerve (HG) stimulation with a multi-contact peripheral nerve electrode were assessed using images of the upper airways and the tongue in anesthetized beagles. A biphasic pulse train of 50 Hz frequency and 2 s duration was applied through each one of the tripolar contact ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/2/4/002

    authors: Huang J,Sahin M,Durand DM

    更新日期:2005-12-01 00:00:00

  • Control of a humanoid robot by a noninvasive brain-computer interface in humans.

    abstract::We describe a brain-computer interface for controlling a humanoid robot directly using brain signals obtained non-invasively from the scalp through electroencephalography (EEG). EEG has previously been used for tasks such as controlling a cursor and spelling a word, but it has been regarded as an unlikely candidate fo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/2/012

    authors: Bell CJ,Shenoy P,Chalodhorn R,Rao RP

    更新日期:2008-06-01 00:00:00

  • Rehabilitation regimes based upon psychophysical studies of prosthetic vision.

    abstract::Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elemen...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/3/035009

    authors: Chen SC,Suaning GJ,Morley JW,Lovell NH

    更新日期:2009-06-01 00:00:00

  • Understanding ultrasound neuromodulation using a computationally efficient and interpretable model of intramembrane cavitation.

    abstract:OBJECTIVE:Low-intensity focused ultrasound stimulation (LIFUS) emerges as an attracting technology for noninvasive modulation of neural circuits, yet the underlying action mechanisms remain unclear. The neuronal intramembrane cavitation excitation (NICE) model suggests that LIFUS excites neurons through a complex inter...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab1685

    authors: Lemaire T,Neufeld E,Kuster N,Micera S

    更新日期:2019-08-01 00:00:00

  • A stationary wavelet transform and a time-frequency based spike detection algorithm for extracellular recorded data.

    abstract:OBJECTIVE:Spike detection from extracellular recordings is a crucial preprocessing step when analyzing neuronal activity. The decision whether a specific part of the signal is a spike or not is important for any kind of other subsequent preprocessing steps, like spike sorting or burst detection in order to reduce the c...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa654b

    authors: Lieb F,Stark HG,Thielemann C

    更新日期:2017-06-01 00:00:00

  • Pavlovian control of intraspinal microstimulation to produce over-ground walking.

    abstract:OBJECTIVE:Neuromodulation technologies are increasingly used for improving function after neural injury. To achieve a symbiotic relationship between device and user, the device must augment remaining function, and independently adapt to day-to-day changes in function. The goal of this study was to develop predictive co...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8e8e

    authors: Dalrymple AN,Roszko DA,Sutton RS,Mushahwar VK

    更新日期:2020-06-02 00:00:00

  • Chronic recording of hand prosthesis control signals via a regenerative peripheral nerve interface in a rhesus macaque.

    abstract:OBJECTIVE:Loss of even part of the upper limb is a devastating injury. In order to fully restore natural function when lacking sufficient residual musculature, it is necessary to record directly from peripheral nerves. However, current approaches must make trade-offs between signal quality and longevity which limit the...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/4/046007

    authors: Irwin ZT,Schroeder KE,Vu PP,Tat DM,Bullard AJ,Woo SL,Sando IC,Urbanchek MG,Cederna PS,Chestek CA

    更新日期:2016-08-01 00:00:00

  • In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes.

    abstract:OBJECTIVE:Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba560

    authors: Shivdasani MN,Evans M,Burns O,Yeoh J,Allen PJ,Nayagam DAX,Villalobos J,Abbott CJ,Luu CD,Opie NL,Sabu A,Saunders AL,McPhedran M,Cardamone L,McGowan C,Maxim V,Williams RA,Fox KE,Cicione R,Garrett DJ,Ahnood A,Ganes

    更新日期:2020-08-05 00:00:00

  • Adaptive optimal input design and parametric estimation of nonlinear dynamical systems: application to neuronal modeling.

    abstract:OBJECTIVE:Many physical models of biological processes including neural systems are characterized by parametric nonlinear dynamical relations between driving inputs, internal states, and measured outputs of the process. Fitting such models using experimental data (data assimilation) is a challenging task since the phys...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aac3f7

    authors: Madi MK,Karameh FN

    更新日期:2018-08-01 00:00:00

  • Open Ephys electroencephalography (Open Ephys  +  EEG): a modular, low-cost, open-source solution to human neural recording.

    abstract:OBJECTIVE:Electroencephalography (EEG) offers a unique opportunity to study human neural activity non-invasively with millisecond resolution using minimal equipment in or outside of a lab setting. EEG can be combined with a number of techniques for closed-loop experiments, where external devices are driven by specific ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa651f

    authors: Black C,Voigts J,Agrawal U,Ladow M,Santoyo J,Moore C,Jones S

    更新日期:2017-06-01 00:00:00