In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

Abstract:

:After extended implantation times, traditional intracortical neural probes exhibit a foreign-body reaction characterized by a reactive glial sheath that has been associated with increased system impedance and signal deterioration. Previously, we have proposed that the local in vivo polymerization of an electronically and ionically conducting polymer, poly(3,4-ethylenedioxythiophene) (PEDOT), might help to rebuild charge transport pathways across the glial scar between the device and surrounding parenchyma (Richardson-Burns et al 2007 J. Neural Eng. 4 L6-13). The EDOT monomer can be delivered via a microcannula/electrode system into the brain tissue of living animals followed by direct electrochemical polymerization, using the electrode itself as a source of oxidative current. In this study, we investigated the long-term effect of local in vivo PEDOT deposition on hippocampal neural function and histology. Rodent subjects were trained on a hippocampus-dependent task, delayed alternation (DA), and implanted with the microcannula/electrode system in the hippocampus. The animals were divided into four groups with different delay times between the initial surgery and the electrochemical polymerization: (1) control (no polymerization), (2) immediate (polymerization within 5 min of device implantation), (3) early (polymerization within 3-4 weeks after implantation) and (4) late (polymerization 7-8 weeks after polymerization). System impedance at 1 kHz was recorded and the tissue reactions were evaluated by immunohistochemistry. We found that under our deposition conditions, PEDOT typically grew at the tip of the electrode, forming an ∼500 µm cloud in the tissue. This is much larger than the typical width of the glial scar (∼150 µm). After polymerization, the impedance amplitude near the neurologically important frequency of 1 kHz dropped for all the groups; however, there was a time window of 3-4 weeks for an optimal decrease in impedance. For all surgery-polymerization time intervals, the polymerization did not cause significant deficits in performance of the DA task, suggesting that hippocampal function was not impaired by PEDOT deposition. However, GFAP+ and ED-1+ cells were also found at the deposition two weeks after the polymerization, suggesting potential secondary scarring. Therefore, less extensive deposition or milder deposition conditions may be desirable to minimize this scarring while maintaining decreased system impedance.

journal_name

J Neural Eng

authors

Ouyang L,Shaw CL,Kuo CC,Griffin AL,Martin DC

doi

10.1088/1741-2560/11/2/026005

subject

Has Abstract

pub_date

2014-04-01 00:00:00

pages

026005

issue

2

eissn

1741-2560

issn

1741-2552

journal_volume

11

pub_type

杂志文章
  • A high-density carbon fiber neural recording array technology.

    abstract:OBJECTIVE:Microwire and Utah-style neural recording arrays are the predominant devices used for cortical neural recording, but the implanted electrodes cause a significant adverse biological response and suffer from well-studied performance degradation. Recent work has demonstrated that carbon fiber electrodes do not e...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aae8d9

    authors: Massey TL,Santacruz SR,Hou JF,Pister KSJ,Carmena JM,Maharbiz MM

    更新日期:2019-02-01 00:00:00

  • Natural language processing with dynamic classification improves P300 speller accuracy and bit rate.

    abstract::The P300 speller is an example of a brain-computer interface that can restore functionality to victims of neuromuscular disorders. Although the most common application of this system has been communicating language, the properties and constraints of the linguistic domain have not to date been exploited when decoding b...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/1/016004

    authors: Speier W,Arnold C,Lu J,Taira RK,Pouratian N

    更新日期:2012-02-01 00:00:00

  • Comparing user-dependent and user-independent training of CNN for SSVEP BCI.

    abstract:OBJECTIVE:We presented a comparative study on the training methodologies of a convolutional neural network (CNN) for the detection of steady-state visually evoked potentials (SSVEP). Two training scenarios were also compared: user-independent (UI) training and user-dependent (UD) training. APPROACH:The CNN was trained...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab6a67

    authors: Ravi A,Beni NH,Manuel J,Jiang N

    更新日期:2020-04-08 00:00:00

  • Carbon nanotube composite coating of neural microelectrodes preferentially improves the multiunit signal-to-noise ratio.

    abstract::Extracellular metal microelectrodes are widely used to record single neuron activity in vivo. However, their signal-to-noise ratio (SNR) is often far from optimal due to their high impedance value. It has been recently reported that carbon nanotube (CNT) coatings may decrease microelectrode impedance, thus improving t...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/6/066013

    authors: Baranauskas G,Maggiolini E,Castagnola E,Ansaldo A,Mazzoni A,Angotzi GN,Vato A,Ricci D,Panzeri S,Fadiga L

    更新日期:2011-12-01 00:00:00

  • DataHigh: graphical user interface for visualizing and interacting with high-dimensional neural activity.

    abstract:OBJECTIVE:Analyzing and interpreting the activity of a heterogeneous population of neurons can be challenging, especially as the number of neurons, experimental trials, and experimental conditions increases. One approach is to extract a set of latent variables that succinctly captures the prominent co-fluctuation patte...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/6/066012

    authors: Cowley BR,Kaufman MT,Butler ZS,Churchland MM,Ryu SI,Shenoy KV,Yu BM

    更新日期:2013-12-01 00:00:00

  • Autoencoders for learning template spectrograms in electrocorticographic signals.

    abstract:OBJECTIVE:Electrocorticography (ECoG) based studies generally analyze features from specific frequency bands selected by manual evaluation of spectral power. However, the definition of these features can vary across subjects, cortical areas, tasks and across time for a given subject. We propose an autoencoder based app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf13f

    authors: Pailla T,Miller KJ,Gilja V

    更新日期:2019-02-01 00:00:00

  • Low-intensity pulsed ultrasound modulates multi-frequency band phase synchronization between LFPs and EMG in mice.

    abstract:OBJECTIVE:Low-intensity pulsed ultrasound stimulation (LIPUS) targeted to the mouse motor cortex can simultaneously induce local field potentials (LFPs) and electromyogram (EMG) responses. However, the functional coupling relationship between LFP and EMG signals has not been elucidated to date. This study aimed to inve...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab0879

    authors: Wang Y,Xie P,Zhou S,Wang X,Yuan Y

    更新日期:2019-04-01 00:00:00

  • Assessing altered motor unit recruitment patterns in paretic muscles of stroke survivors using surface electromyography.

    abstract:OBJECTIVE:The advancement of surface electromyogram (sEMG) recording and signal processing techniques has allowed us to characterize the recruitment properties of a substantial population of motor units (MUs) non-invasively. Here we seek to determine whether MU recruitment properties are modified in paretic muscles of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/6/066001

    authors: Hu X,Suresh AK,Rymer WZ,Suresh NL

    更新日期:2015-12-01 00:00:00

  • Improved mobility performance with an artificial vision therapy system using a thermal sensor.

    abstract:OBJECTIVE:To evaluate the benefit of integrating thermal imaging into an artificial vision therapy system, the Argus II retinal prosthesis, in simplifying a complex scene and improving mobility performance in the presence of other persons. APPROACH:Four Argus II retinal implant users were evaluated on two tasks: to lo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba4fb

    authors: He Y,Sun SY,Roy A,Caspi A,Montezuma SR

    更新日期:2020-08-04 00:00:00

  • Ensembles of adaptive spatial filters increase BCI performance: an online evaluation.

    abstract:OBJECTIVE:In electroencephalographic (EEG) data, signals from distinct sources within the brain are widely spread by volume conduction and superimposed such that sensors receive mixtures of a multitude of signals. This reduction of spatial information strongly hampers single-trial analysis of EEG data as, for example, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/4/046003

    authors: Sannelli C,Vidaurre C,Müller KR,Blankertz B

    更新日期:2016-08-01 00:00:00

  • Multi-class EEG classification of voluntary hand movement directions.

    abstract:OBJECTIVE:Studies have shown that low frequency components of brain recordings provide information on voluntary hand movement directions. However, non-invasive techniques face more challenges compared to invasive techniques. APPROACH:This study presents a novel signal processing technique to extract features from non-...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/5/056018

    authors: Robinson N,Guan C,Vinod AP,Ang KK,Tee KP

    更新日期:2013-10-01 00:00:00

  • Hardware architecture for real-time EEG-based functional brain connectivity parameter extraction.

    abstract::In this work, we proposed a novel architecture for real-time quantitative characterization of functional brain connectivity networks derived from Electroencephalogram (EEG). It consists of two main parts - calculation of Phase Lag Index (PLI) to form the functional connectivity networks and the extraction of a set of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd462

    authors: Gutierrez Nuno RA,Chung CHR,Maharatna K

    更新日期:2020-12-16 00:00:00

  • Controlling selective stimulations below a spinal cord hemisection using brain recordings with a neural interface system approach.

    abstract::In this work we address the use of realtime cortical recordings for the generation of coherent, reliable and robust motor activity in spinal-lesioned animals through selective intraspinal microstimulation (ISMS). The spinal cord of adult rats was hemisectioned and groups of multielectrodes were implanted in both the c...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046008

    authors: Panetsos F,Sanchez-Jimenez A,Torets C,Largo C,Micera S

    更新日期:2011-08-01 00:00:00

  • Modeling deep brain stimulation: point source approximation versus realistic representation of the electrode.

    abstract::Deep brain stimulation (DBS) has emerged as an effective treatment for movement disorders; however, the fundamental mechanisms by which DBS works are not well understood. Computational models of DBS can provide insights into these fundamental mechanisms and typically require two steps: calculation of the electrical po...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/6/066009

    authors: Zhang TC,Grill WM

    更新日期:2010-12-01 00:00:00

  • An improved P300 pattern in BCI to catch user's attention.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) can help patients who have lost control over most muscles but are still conscious and able to communicate or interact with the environment. One of the most popular types of BCI is the P300-based BCI. With this BCI, users are asked to count the number of appearances of target s...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6213

    authors: Jin J,Zhang H,Daly I,Wang X,Cichocki A

    更新日期:2017-06-01 00:00:00

  • Myoelectric control with abstract decoders.

    abstract:OBJECTIVE:The objective of this study was to compare the use of muscles appropriate for partial-hand prostheses with those typically used for complete hand devices and to determine whether differences in their underlying neural substrates translate to different levels of myoelectric control. APPROACH:We developed a no...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aacbfe

    authors: Dyson M,Barnes J,Nazarpour K

    更新日期:2018-10-01 00:00:00

  • Spatial channel interactions in cochlear implants.

    abstract::The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies g...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046029

    authors: Tang Q,Benítez R,Zeng FG

    更新日期:2011-08-01 00:00:00

  • Concurrent control of a brain-computer interface and natural overt movements.

    abstract:OBJECTIVE:A primary control signal in brain-computer interfaces (BCIs) have been cortical signals related to movement. However, in cases where natural motor function remains, BCI control signals may interfere with other possibly simultaneous activity for useful ongoing movement. We sought to determine if the brain coul...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aadf3d

    authors: Bashford L,Wu J,Sarma D,Collins K,Rao RPN,Ojemann JG,Mehring C

    更新日期:2018-12-01 00:00:00

  • High-fidelity vibrokinetic stimulation induces sustained changes in intercortical coherence during a cinematic experience.

    abstract:OBJECTIVE:High-fidelity vibrokinetic (HFVK) technology is widely used to enhance the immersiveness of audiovisual (AV) entertainment experiences. However, despite evidence that HFVK technology does subjectively enhance AV immersion, the underlying mechanism has not been clarified. Neurophysiological studies could provi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abaca2

    authors: Boasen J,Giroux F,Duchesneau MO,Sénécal S,Léger PM,Ménard JF

    更新日期:2020-09-26 00:00:00

  • Performance predictors of brain-computer interfaces in patients with amyotrophic lateral sclerosis.

    abstract:OBJECTIVE:Patients with amyotrophic lateral sclerosis (ALS) may benefit from brain-computer interfaces (BCI), but the utility of such devices likely will have to account for the functional, cognitive, and behavioral heterogeneity of this neurodegenerative disorder. APPROACH:In this study, a heterogeneous group of pati...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026002

    authors: Geronimo A,Simmons Z,Schiff SJ

    更新日期:2016-04-01 00:00:00

  • Motor cortex stimulation for Parkinson's disease: a modelling study.

    abstract::Chronic motor cortex stimulation (MCS) is currently being investigated as a treatment method for Parkinson's disease (PD). Unfortunately, the underlying mechanisms of this treatment are unclear and there are many uncertainties regarding the most effective stimulation parameters and electrode configuration. In this pap...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/5/056005

    authors: Zwartjes DG,Heida T,Feirabend HK,Janssen ML,Visser-Vandewalle V,Martens HC,Veltink PH

    更新日期:2012-10-01 00:00:00

  • Rehabilitation regimes based upon psychophysical studies of prosthetic vision.

    abstract::Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elemen...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/3/035009

    authors: Chen SC,Suaning GJ,Morley JW,Lovell NH

    更新日期:2009-06-01 00:00:00

  • Real-time cerebellar neuroprosthetic system based on a spiking neural network model of motor learning.

    abstract:OBJECTIVE:Damage to the brain, as a result of various medical conditions, impacts the everyday life of patients and there is still no complete cure to neurological disorders. Neuroprostheses that can functionally replace the damaged neural circuit have recently emerged as a possible solution to these problems. Here we ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa98e9

    authors: Xu T,Xiao N,Zhai X,Kwan Chan P,Tin C

    更新日期:2018-02-01 00:00:00

  • The development of neural stimulators: a review of preclinical safety and efficacy studies.

    abstract:OBJECTIVE:Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technolog...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aac43c

    authors: Shepherd RK,Villalobos J,Burns O,Nayagam DAX

    更新日期:2018-08-01 00:00:00

  • Early seizure detection for closed loop direct neurostimulation devices in epilepsy.

    abstract::Current treatment concepts for epilepsy are based on continuous drug delivery or electrical stimulation to prevent the occurrence of seizures, exposing the brain and body to a mostly unneeded risk of adverse effects. To address the infrequent occurrence and short duration of epileptic seizures, intelligent implantable...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/ab094a

    authors: Dümpelmann M

    更新日期:2019-08-01 00:00:00

  • The response of retinal neurons to high-frequency stimulation.

    abstract:OBJECTIVE:High-rate pulse trains have proven to be effective in cochlear prosthetics and, more recently, have been shown to elicit a wide range of interesting response properties in axons of the peripheral nervous system. Surprisingly, the effectiveness of such trains for use in retinal prostheses has not been explored...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/3/036009

    authors: Cai C,Twyford P,Fried S

    更新日期:2013-06-01 00:00:00

  • HMM based automated wheelchair navigation using EOG traces in EEG.

    abstract::This paper presents a wheelchair navigation system based on a hidden Markov model (HMM), which we developed to assist those with restricted mobility. The semi-autonomous system is equipped with obstacle/collision avoidance sensors and it takes the electrooculography (EOG) signal traces from the user as commands to man...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/5/056018

    authors: Aziz F,Arof H,Mokhtar N,Mubin M

    更新日期:2014-10-01 00:00:00

  • Optimizing the design of bipolar nerve cuff electrodes for improved recording of peripheral nerve activity.

    abstract:OBJECTIVE:Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordin...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6407

    authors: Sabetian P,Popovic MR,Yoo PB

    更新日期:2017-06-01 00:00:00

  • Task-dependent signal variations in EEG error-related potentials for brain-computer interfaces.

    abstract:OBJECTIVE:A major difficulty of brain-computer interface (BCI) technology is dealing with the noise of EEG and its signal variations. Previous works studied time-dependent non-stationarities for BCIs in which the user's mental task was independent of the device operation (e.g., the mental task was motor imagery and the...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/2/026024

    authors: Iturrate I,Montesano L,Minguez J

    更新日期:2013-04-01 00:00:00

  • CO2 sensitivity of the complexity of phrenic neurograms in the piglet during early maturation.

    abstract::In this paper, we investigate the influence of hypercapnia on the dynamics of the phrenic neurogram in the piglet in two different age groups: 3-7 days (n = 11) and 10-16 days (n = 9). The phrenic neurogram was recorded from 17 piglets (3-16 days old) during control (40% O(2) with 3-5% end-tidal CO(2)), mild hypercapn...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/2/2/004

    authors: Akay M

    更新日期:2005-06-01 00:00:00