Gas chromatography-chemical ionization mass spectrometry of cocaine and its metabolites in biological fluids.

Abstract:

:A gas chromatographic-chemical ionization mass spectrometric (GC-CIMS) method is described for the determination of cocaine, benzoylecgonine, and norcocaine. The procedure uses stable isotopes as internal standards and a mixture of methane-ammonia as chemical ionization reagent gas. Run-to-run and within-run coefficients of variation (%) are less than 10% and the method has a sensitivity of less than 5 ng/mL from 1 mL or 1 gram of sample. The procedure has been applied to a number of cases involving cocaine intoxication and analytical data from these are described.

journal_name

J Anal Toxicol

authors

Chinn DM,Crouch DJ,Peat MA,Finkle BS,Jennison TA

doi

10.1093/jat/4.1.37

subject

Has Abstract

pub_date

1980-01-01 00:00:00

pages

37-42

issue

1

eissn

0146-4760

issn

1945-2403

journal_volume

4

pub_type

杂志文章
  • Monitoring saliva concentrations of methaqualone, codeine, secobarbital, diphenhydramine and diazepam after single oral doses.

    abstract::A preliminary investigation was undertaken to determine the feasibility of monitoring saliva levels of drugs for forensic purposes. Single oral doses of the title compounds were administered to healthy volunteers. Plasma and saliva levels were measured and ratios calculated for all drugs except diazepam. Saliva/plasma...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/7.1.11

    authors: Sharp ME,Wallace SM,Hindmarsh KW,Peel HW

    更新日期:1983-01-01 00:00:00

  • Case report: an arsenic murder.

    abstract::An arsenic death was investigated six and one half years after the demise. Analysis of tissue embedded in paraffin blocks demonstrated toxic concentrations. Spectrophotometry was employed with the use of a hydride generator to provide specificity and sensitivity to less than 0.05 microgram. ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/6.5.260

    authors: Bednarczyk LR,Matusiak W

    更新日期:1982-09-01 00:00:00

  • Determination of tibric acid and clofibrate in animal feed, wastewater and hunan urine.

    abstract::Analytical chemical procedures are described to determine residues of the drugs clofibrate and tibric acid in animal feed, wastewater, and human urine. Clofibrate was extracted from animal feed and human urine with hexane, whereas residues from wastewater were collected on a Sep-PakTM then eluted with methanol for ana...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/6.4.175

    authors: Oller WL,Kendall DC,Bowman MC

    更新日期:1982-07-01 00:00:00

  • Closed cup vapor systems in percutaneous exposure studies: what is the dose?

    abstract::Percutaneous vapor dosing studies have generally used saturated vapor concentration (SVC) measurements to estimate the exposure dose (Ct) of vapor produced from a volatile liquid within a closed system. The purpose of this study was to clarify whether the assumption was valid when translated to a biological system (pi...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/30.3.165

    authors: Dalton CH,Maidment MP,Jenner J,Chilcott RP

    更新日期:2006-04-01 00:00:00

  • A micromethod for the on-column methylation of valproic acid by gas-liquid chromatography.

    abstract::We described a simple procedure for the flash heater methylation of valproic acid and cyclohexylacetic acid (internal standard) by gas-liquid chromatography (GLC). A small volume (100 microL) of sample is acidified with 10% perchloric acid and extracted into hexane. An aliquot is back extracted into 5% tetramethylammo...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/4.6.272

    authors: Calendrillo BA,Reynoso G

    更新日期:1980-11-01 00:00:00

  • Quantitation of Δ8-THC, Δ9-THC, Cannabidiol, and Ten Other Cannabinoids and Metabolites in Oral Fluid by HPLC-MS/MS.

    abstract::Quantitative analysis of Δ9-tetrahydrocannabinol (Δ9-THC) in oral fluid has gained increasing interest in clinical and forensic toxicology laboratories. New medicinal and/or recreational cannabinoid products require laboratories to distinguish different patterns of cannabinoid use. This study validated a high-performa...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkaa184

    authors: Lin L,Amaratunga P,Reed J,Huang P,Lemberg BL,Lemberg D

    更新日期:2020-12-03 00:00:00

  • Separation and quantitation of the enantiomers of methamphetamine and its metabolites in urine by HPLC: precolumn derivatization and fluorescence detection.

    abstract::To study the disposition kinetics of methamphetamine (MAP), we have developed a sensitive high-performance liquid chromatographic (HPLC) assay to quantitate the enantiomers of MAP and its major metabolites, amphetamine (AP), p-hydroxymethamphetamine (p-OH-MAP), and p-hydroxyamphetamine (p-OH-AP), the latter two of whi...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/19.3.139

    authors: Sukbuntherng J,Hutchaleelaha A,Chow HH,Mayersohn M

    更新日期:1995-05-01 00:00:00

  • Screening, identification, and quantitation of benzodiazepines in postmortem samples by HPLC with photodiode array detection.

    abstract::A high-performance liquid chromatographic method has been developed for the simultaneous analysis of eight frequently used benzodiazepines and some of their metabolites in postmortem samples. The method includes a liquid-liquid extraction with n-hexane-ethyl acetate (70:30, v/v), gradient elution of a C8 reversed-phas...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/19.1.35

    authors: Lambert WE,Meyer E,Xue-Ping Y,De Leenheer AP

    更新日期:1995-01-01 00:00:00

  • Impact of lowering confirmatory test cutoff value in pre-enlistment urine cannabinoids screening: about five years' experience in the French Gendarmerie.

    abstract::The guidelines for screening of urinary cannabinoids require that all specimens testing positive should be confirmed by gas chromatography-mass spectrometry at a confirmatory test cutoff value of 15 ng/mL of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH). To assess the impact of lowering the confirmatory test cuto...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bks067

    authors: Lecompte Y,Perrin M,Salle S,Roussel O

    更新日期:2012-10-01 00:00:00

  • Methodology for the determination of dinitroaniline herbicides in tissue and excreta.

    abstract::A method is presented for the analysis of trace amounts of dinitroaniline herbicides in tissue and excreta. The method employs extraction of the tissue or excreta with organic solvent, clean up by liquid/liquid partitioning or silica gel chromatography, and ultimate analysis by gas chromatography using electron captur...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/9.1.15

    authors: Edgerton TR,Scott W,Linder RE

    更新日期:1985-01-01 00:00:00

  • Evaluation of drug extraction procedures from urine.

    abstract::Radioactive methadone, phenytoin, phenobarbital, and diazepam were easily and efficiently removed from human urine samples by adsorption on C18 bonded silica phases. These techniques were simpler than conventional extractions at pH 9.3 or 5.2 with dichloromethane, XAD-2 and methanol, or Celite 560 and dichloromethane....

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/9.6.269

    authors: Hyde PM

    更新日期:1985-11-01 00:00:00

  • Optimization of storage conditions for cocaine and benzoylecgonine in urine: a review.

    abstract::The maximum stability conditions for cocaine and its metabolite benzoylecgonine (BE) in urine were analyzed. Suggestions were presented after careful review of many studies and personal communications concerning cocaine and BE stability in urine. The optimal storage conditions for urine specimens with cocaine and BE w...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章,评审

    doi:10.1093/jat/18.2.104

    authors: Hippenstiel MJ,Gerson B

    更新日期:1994-03-01 00:00:00

  • The measurement of nitrite in adulterated urine samples by high-performance ion chromatography.

    abstract::With the increased availability of nitrite-containing commercial products that are used for the adulteration of urine samples in the workplace, it is necessary for laboratories to be able to detect and confirm the presence of nitrite in these samples. We have developed a method to confirm the presence of nitrite in ur...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/23.3.137

    authors: Singh J,Elberling JA,Hemphill DG,Holmstrom J

    更新日期:1999-05-01 00:00:00

  • Analysis of codeine positivity in urine of pain management patients.

    abstract::The opioids codeine and morphine have legitimate uses in managing chronic pain conditions, but they are frequently abused. Patients prescribed opioids submit urine samples for medication compliance monitoring, and the interpretation of the results is complex. The purpose of this study was to evaluate the percentage of...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkv031

    authors: Colby JM,Wu AH,Lynch KL

    更新日期:2015-06-01 00:00:00

  • Measurement of carbamazepine and its main biotransformation products in plasma by HPLC.

    abstract::We present a method that permits the simultaneous analysis of carbamazepine (CBZ) and its major biotransformation products, carbamazepine-10,11-epoxide (CBZ-E) and carbamazepine-10,11-dihydroxide (CBZ-diOH), in plasma samples. The method consists of plasma extraction in alkaline medium with NaCl added using chloroform...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/16.2.88

    authors: Bonato PS,Lanchote VL,de Carvalho D,Achê P

    更新日期:1992-03-01 00:00:00

  • Fatal intoxication due to brucine.

    abstract::A sensitive method for identifying and quantifying brucine by means of liquid chromatography-tandem mass spectrometry is presented in this article. Based on a solid-phase extraction for human serum, the validation indicated limits of detection and quantification of 0.12 and 0.23 ng/mL, respectively. In one case of let...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/anatox/35.4.248

    authors: Teske J,Weller JP,Albrecht UV,Fieguth A

    更新日期:2011-05-01 00:00:00

  • Simultaneous determination of eleven benzodiazepine hypnotics and eleven relevant metabolites in urine by column-switching liquid chromatography-mass spectrometry.

    abstract::An automated column-switching liquid chromatographic-atmospheric pressure chemical ionization-mass spectrometric (LC-APCI-MS) method for the simultaneous determination of frequently encountered benzodiazepine hypnotics and their relevant metabolites in urine has been established. A column-switching online solid-phase ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/26.2.87

    authors: Miki A,Tatsuno M,Katagi M,Nishikawa M,Tsuchihashi H

    更新日期:2002-03-01 00:00:00

  • Hair Analysis of Methoxphenidine in a Forensic Chemsex Case.

    abstract::Methoxphenidine (MXP, 2-MeO-diphenidine) is a dissociative anaesthetic drug of the diarylethylamine type, recently introduced for recreational purposes through the online-based sale of new psychoactive substances (NPS). The concentration of MXP in hair has never been reported, either in cases of chemsex use or in fata...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkab016

    authors: Goncalves R,Castaing N,Titier K,Dumestre-Toulet V

    更新日期:2021-02-01 00:00:00

  • Concentrations of heroin, 06-monoacetylmorphine, and morphine in a lethal case following an oral heroin overdose.

    abstract::A case of lethal overdose by heroin ingestion is presented. The concentrations of drugs were measured several hours after death. Heroin, 06-monoacetylmorphine, and morphine were identified and quantitated in blood, urine, and gastrointestinal contents by gas chromatography-mass spectrometry and high-performance liquid...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.3.232

    authors: Rop PP,Fornaris M,Salmon T,Burle J,Bresson M

    更新日期:1997-05-01 00:00:00

  • Child Fatalities Due to Heroin/Fentanyl Exposure: What the Case History Missed.

    abstract::This case report presents three unrelated children found to have heroin and/or fentanyl in their systems after general unknown systematic toxicological analysis (STA). The first case involves an 11-month-old male found unresponsive at their residence. The scene response suggested a potentially unsafe sleeping conditio...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bky052

    authors: DeRienz RT,Baker DD,Kelly NE,Mullins AM,Barnett RY,Hobbs JM,Daniels JA,Harshbarger KE,Ortiz AM

    更新日期:2018-10-01 00:00:00

  • A simple, rapid gas-liquid chromatographic procedure for the determination of valproic acid in serum.

    abstract::A simple, rapid method for the gas-liquid chromatographic (GLC) determination of valproic acid in serum without prior derivatization on a Nukol wide-bore capillary column is presented. The method was determined to have a lower limit of detection (LOD) of 5 mg/L and a lower limit of quantitation (LOQ) of 10 mg/L; the m...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.4.306

    authors: Wohler AS,Poklis A

    更新日期:1997-07-01 00:00:00

  • A comparison of a microdiffusion method for ethanol and the Abbott TDx ethanol assay.

    abstract::A simple, rapid ethanol screen based on a microdiffusion technique (Analytical Systems, Marion Laboratories) has been evaluated and compared to an established enzymatic procedure (Abbott TDx). They showed agreement in 484 of 488 biological specimens and all control specimens. They disagreed on 4 specimens--3 positive ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/12.6.348

    authors: Serrano L,Capshaw B,Quattrocchi F

    更新日期:1988-11-01 00:00:00

  • Detection of Delta9-tetrahydrocannabinol and amphetamine-type stimulants in oral fluid using the Rapid Stat point-of-collection drug-testing device.

    abstract::The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic chec...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/34.3.155

    authors: Röhrich J,Zörntlein S,Becker J,Urban R

    更新日期:2010-04-01 00:00:00

  • The prevalence of alcohol and drugs in sampled oral fluid is related to sample volume.

    abstract::About 22,000 samples of oral fluid have been collected in five population studies in Norway using either the Intercept or Statsure oral fluid sampling devices. The prevalence of alcohol and drugs was found to be higher in oral fluid samples with small volumes than in those with large volumes for both sampling devices;...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/34.7.416

    authors: Gjerde H,Normann PT,Christophersen AS

    更新日期:2010-09-01 00:00:00

  • The determination of amphetamine and methamphetamine in a lyophilized human urine reference material.

    abstract::The concentrations of amphetamine and methamphetamine in a new lyophilized human urine reference material (RM) were determined at the National Institute of Standards and Technology, in cooperation with the College of American Pathologists. In order to minimize the possibility of undetected bias, two different methods ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/17.3.165

    authors: Ellerbe P,Long T,Welch MJ

    更新日期:1993-05-01 00:00:00

  • High-resolution proton nuclear magnetic resonance spectroscopy in the detection of low molecular weight volatiles.

    abstract::Proton nuclear magnetic resonance spectroscopy (1H MRS) has been used to identify ethanol in vivo and to detect other exogenous low molecular weight volatiles in human serum. 1H MRS was used to detect and quantitate 15 human sera containing various concentrations and combinations of ethanol, isopropanol, acetone, and ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/17.5.273

    authors: Pappas AA,Thompson JR,Fuller GL,Porter WH,Gadsden RH

    更新日期:1993-09-01 00:00:00

  • Pretreatment of urine samples for the analysis of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid using solid-phase extraction.

    abstract::An extraction and concentration procedure using a unique solid-phase extraction tube was developed for the analysis of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid in urine. Absolute and relative recoveries of the drug metabolite were found to be greater than 85% and 92%, respectively. The extraction procedur...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/14.1.39

    authors: Parry RC,Nolan L,Shirey RE,Wachob GD,Gisch DJ

    更新日期:1990-01-01 00:00:00

  • Ethyl sulfate: a metabolite of ethanol in humans and a potential biomarker of acute alcohol intake.

    abstract::This study identified ethyl sulfate (EtS) in human urine and compared the excretion characteristics of EtS with that of ethanol and ethyl glucuronide (EtG). Urine samples were collected from healthy subjects after a single ethanol dose, and also selected from routine clinical samples. Simultaneous analysis of EtS and ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/29.5.270

    authors: Helander A,Beck O

    更新日期:2005-07-01 00:00:00

  • Urine concentrations of fentanyl and norfentanyl during application of Duragesic transdermal patches.

    abstract::A study of the urinary concentration of fentanyl (F) and its major metabolite norfentanyl (NF) in chronic pain patients treated with the Duragesic continuous release transdermal patches is presented. These patches are available in 10, 20, 30, and 40 cm(2) sizes releasing 25, 50, 75, and 100 microg/h F, respectively. F...

    journal_title:Journal of analytical toxicology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1093/jat/28.6.422

    authors: Poklis A,Backer R

    更新日期:2004-09-01 00:00:00

  • A simple and sensitive quantitation of N,N-dimethyltryptamine by gas chromatography with surface ionization detection.

    abstract::A simple and sensitive method for determination of N,N-dimethyltryptamine (DMT) by gas chromatography (GC) with surface ionization detection (SID) is presented. Whole blood or urine, containing DMT and gramine (internal standard), was subjected to solid-phase extraction with a Sep-Pak C18 cartridge before analysis by ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.1.36

    authors: Ishii A,Seno H,Suzuki O,Hattori H,Kumazawa T

    更新日期:1997-01-01 00:00:00