A micromethod for the on-column methylation of valproic acid by gas-liquid chromatography.

Abstract:

:We described a simple procedure for the flash heater methylation of valproic acid and cyclohexylacetic acid (internal standard) by gas-liquid chromatography (GLC). A small volume (100 microL) of sample is acidified with 10% perchloric acid and extracted into hexane. An aliquot is back extracted into 5% tetramethylammonium hydroxide (TMH). A 1 microL sample of the TMH layer is injected into the GLC equipped with flame ionization detector (FID) and a 6 ft x 2 mm i.d. - nickel column packed with 3% OV-17 on 80/100 mesh Supelcoport. The injector temperature is set at 350 degrees C to ensure methylation. Recoveries are greater than 95% of theoretical value. The linearity for calibration points between 15 and 180 microgram/mL is excellent (coefficient of correlation and determination greater than 0.9999). The procedure is rapid and sensitive and does not require a dedicated column in the gas chromatograph.

journal_name

J Anal Toxicol

authors

Calendrillo BA,Reynoso G

doi

10.1093/jat/4.6.272

subject

Has Abstract

pub_date

1980-11-01 00:00:00

pages

272-4

issue

6

eissn

0146-4760

issn

1945-2403

journal_volume

4

pub_type

杂志文章
  • Hair Analysis of Methoxphenidine in a Forensic Chemsex Case.

    abstract::Methoxphenidine (MXP, 2-MeO-diphenidine) is a dissociative anaesthetic drug of the diarylethylamine type, recently introduced for recreational purposes through the online-based sale of new psychoactive substances (NPS). The concentration of MXP in hair has never been reported, either in cases of chemsex use or in fata...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkab016

    authors: Goncalves R,Castaing N,Titier K,Dumestre-Toulet V

    更新日期:2021-02-01 00:00:00

  • High-performance liquid chromatographic analysis of cocaine in human plasma.

    abstract::A simple isocratic HPLC procedure for the analysis of cocaine in plasma, with or without an internal standard, is described for the first time. Basified plasma was extracted in ether, re-extracted in acetic acid, which was subsequently basified prior to the final extraction in n-hexane. The hexane extract was evaporat...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/4.6.305

    authors: Masoud AN,Krupski DM

    更新日期:1980-11-01 00:00:00

  • Simultaneous identification and quantitation of codeine and morphine in urine by capillary gas chromatography and mass spectroscopy.

    abstract::An analytical procedure for simultaneous determination of codeine and morphine in urine is described. The detection of codeine and morphine is based on liquid-liquid extraction and derivatization to the acetylated compounds. The acetylated codeine and morphine are separated by capillary gas chromatography and identifi...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/9.5.222

    authors: Paul BD,Mell LD Jr,Mitchell JM,Irving J,Novak AJ

    更新日期:1985-09-01 00:00:00

  • Methodology for the determination of dinitroaniline herbicides in tissue and excreta.

    abstract::A method is presented for the analysis of trace amounts of dinitroaniline herbicides in tissue and excreta. The method employs extraction of the tissue or excreta with organic solvent, clean up by liquid/liquid partitioning or silica gel chromatography, and ultimate analysis by gas chromatography using electron captur...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/9.1.15

    authors: Edgerton TR,Scott W,Linder RE

    更新日期:1985-01-01 00:00:00

  • A rapid cation-exchange HPLC method for detection and quantification of pyridinium oximes in plasma and tissue.

    abstract::A rapid and sensitive assay for pyridinium oximes in plasma and tissue was developed. The method was suitable for the analysis of mono- and di-pyridinium oximes and utilizes ultrafiltration followed by cation-exchange high-performance liquid chromatography with UV detection. The assay was originally developed for the ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/31.2.69

    authors: Singh H,Moorad-Doctor D,Ratcliffe RH,Wachtel K,Castillo A,Garcia GE

    更新日期:2007-03-01 00:00:00

  • Neurotoxic esterase (NTE) assay: optimized conditions based on detergent-induced shifts in the phenol/4-aminoantipyrine chromophore spectrum.

    abstract::An assay for neurotoxic esterase (neuropathy target esterase, NTE) was developed by Johnson (1,2) to assess the delayed neurotoxic potential of organophosphorus compounds. NTE activity is calculated from the rate of phenyl valerate hydrolysis resistant to paraoxon and sensitive to mipafox inhibition under specified co...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/15.2.86

    authors: Kayyali US,Moore TB,Randall JC,Richardson RJ

    更新日期:1991-03-01 00:00:00

  • Determination of opiates and cocaine and its metabolites in biological fluids by high-performance liquid chromatography with electrospray tandem mass spectrometry.

    abstract::A rapid, sensitive, and specific method for the determination of opiates and cocaine and metabolites in urine, plasma, and blood was established. A one-step extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry operating in multiple reaction monitoring mode was used. Two chromat...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/23.7.620

    authors: Cailleux A,Le Bouil A,Auger B,Bonsergent G,Turcant A,Allain P

    更新日期:1999-11-01 00:00:00

  • Quantitative analysis of l-alpha-acetylmethadol, l-alpha-acetyl-N-normethadol, and l-alpha-acetyl-N,N-dinormethadol in human hair by positive ion chemical ionization mass spectrometry.

    abstract::A sensitive and specific method was developed for the quantitative analysis of l-alpha-acetylmethadol (LAAM), l-alpha-acetyl-N-normethadol (norLAAM), and l-alpha-acetyl-N,N-dinormethadol (dinorLAAM) in hair. In the development of this method, it was determined that sample pretreatment methods performed by the laborato...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/21.6.420

    authors: Wilkins DG,Valdez AS,Krueger GG,Rollins DE

    更新日期:1997-10-01 00:00:00

  • Simultaneous determination of eight anticoagulant rodenticides in blood serum and liver.

    abstract::A liquid chromatographic method was developed for the analysis of indandione and 4-hydroxycoumarin anticoagulant rodenticides in blood serum and liver. The method enabled the measurement of serum and liver concentrations of eight anticoagulant rodenticides: brodifacoum, bromadiolone, chlorophacinone, coumafuryl, couma...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/17.1.56

    authors: Chalermchaikit T,Felice LJ,Murphy MJ

    更新日期:1993-01-01 00:00:00

  • X-ray microanalysis of calcium, potassium, and phosphorus in liver mitochondria stressed by carbon tetrachloride.

    abstract::Previous measurements of elemental concentrations in liver mitochondria have generally required homogenization and fractionation of liver tissue, a procedure in which it is difficult to rule out ion movement between subcellular units. New techniques involving cryoultramicrotomy of rapidly frozen tissue, high resolutio...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/9.4.145

    authors: Millette JR,Allenspach AL,Clark PJ,McCauley PT,Washington IS

    更新日期:1985-07-01 00:00:00

  • Screening of xenobiotics by ultra-performance liquid chromatography-mass spectrometry using in-source fragmentation at increasing cone voltages: library constitution and an evaluation of spectral stability.

    abstract::In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a fast (15 min) comprehensive screening method for 500 toxicologically relevant analytes based on ultra-performance liquid chromatography (UPLC) coupled with a quadrupol...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/34.9.571

    authors: Humbert L,Grisel F,Richeval C,Lhermitte M

    更新日期:2010-11-01 00:00:00

  • Quantitative determination of phenelzine in human fluids by gas chromatography with nitrogen specific detection.

    abstract::A quantitative gas chromatographic assay for the determination of phenelzine in plasma or other fluids is presented. A stable derivative is formed by cyclization with acetylacetone, and the derivative is separated, purified, and concentrated by liquid-liquid solvent extraction. Analysis of the extracts is by capillary...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/12.2.98

    authors: Lichtenwalner M,McMullin M,Hardy D,Rieders F

    更新日期:1988-03-01 00:00:00

  • A gas-chromatographic method for the determination of vinylidene chloride in air.

    abstract::A gas-chromatographic analysis of vinylidene chloride (1,1-dichloroethylene) is presented. Vinylidene chloride was sampled by adsorbing on activated carbon. It was desorbed with carbon disulfide. The desorption efficiency was 97.2 +/- 1.05 (mean +/- standard error). The analytical column was packed with 10% Apiezon L ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/4.5.266

    authors: Sidhu KS

    更新日期:1980-09-01 00:00:00

  • Cobas Mira S endpoint enzymatic assay for plasma formate.

    abstract::In methanol intoxication, increased levels of the metabolite formate are associated with metabolic acidosis and an increased risk for ocular and neurological dysfunction. A simple method for plasma formate measurement by adaptation of a manual enzymatic assay to a Cobas Mira S analyzer is presented. Six microliters of...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/25.2.77

    authors: Blomme B,Lheureux P,Gerlo E,Maes V

    更新日期:2001-03-01 00:00:00

  • A Novel Liquid Chromatography Tandem Mass Spectrometry Technique using Multi-Period-Multi-Experiment of MRM-EPI-MRM3 with Library Matching for Simultaneous Determination of Amphetamine Type Stimulants Related Drugs in Whole Blood, Urine and Dried Blood St

    abstract::A novel mass spectrometry detection technique based on a multi-period and multi- experiment (MRM-EPI-MRM3) with library matching in a single run for fast and rapid screening and identification of amphetamine type stimulants (ATS) related drugs in whole blood, urine and dried blood stain was developed and validated. Th...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkz017

    authors: Zubaidi FA,Choo YM,Tan GH,Hamid HA,Choy YK

    更新日期:2019-08-23 00:00:00

  • Concentration of oxymorphone in postmortem fluids and tissue.

    abstract::Oxymorphone, a semi-synthetic opioid analgesic, has been available as Numorphan since the 1950s in the form of injectable solutions and a suppository. Recently, in 2006, oxymorphone was approved by the Federal Drug Administration for use in the form of immediate and extended release tablets under the trade name Opana....

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/33.3.121

    authors: Garside D,Hargrove RL,Winecker RE

    更新日期:2009-04-01 00:00:00

  • Monitoring of aluminum in whole blood, plasma, serum, and water by a single procedure using flameless atomic absorption spectrophotometry.

    abstract::A simple, time-saving procedure to measure aluminum (AI) in whole blood, plasma, and water samples of low ionic strength by flameless atomic absorption spectrometry is presented. With this procedure, an analagous pretreatment is given to all samples. Moreover, the pretreated samples are analyzed using an identical pro...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/9.3.97

    authors: van der Voet GB,de Haas EJ,de Wolff FA

    更新日期:1985-05-01 00:00:00

  • Identification of diuron and four of its metabolites in human postmortem plasma and urine by LC/MS with a moving-belt interface.

    abstract::Unknown compounds that were not amenable to GC/MS were found during routine benzodiazepine HPLC screening in a postmortem case. The apparent thermolability made the application of liquid chromatography with mass spectrometry mandatory. The moving-belt interface was used because of its value for identification based on...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/13.1.8

    authors: Verheij ER,van der Greef J,La Vos GF,van der Pol W,Niessen WM

    更新日期:1989-01-01 00:00:00

  • Recovery and Stability of Δ9-Tetrahydrocannabinol Using the Oral-Eze® Oral Fluid Collection System and Intercept® Oral Specimen Collection Device.

    abstract::Oral fluid (OF) is increasingly used for clinical, forensic and workplace drug testing as an alternative to urine. Uncertainties surrounding OF collection device performance, drug stability and testing reproducibility may be partially responsible for delays in the implementation of OF testing in regulated drug testing...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bkv093

    authors: Samano KL,Anne L,Johnson T,Tang K,Sample RH

    更新日期:2015-10-01 00:00:00

  • Sensitivity of an opiate immunoassay for detecting hydrocodone and hydromorphone in urine from a clinical population: analysis of subthreshold results.

    abstract::Urine drug testing (UDT) is an emerging standard of care in the evaluation and treatment of chronic non-cancer pain patients with opioid analgesics. UDT may be used both to verify adherence with the opioid analgesic regimen and to monitor abstinence from non-prescribed or illicit controlled substances. In the former s...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bku109

    authors: Bertholf RL,Johannsen LM,Reisfield GM

    更新日期:2015-01-01 00:00:00

  • Correlation of saliva codeine concentrations with plasma concentrations after oral codeine administration.

    abstract::A clinical study was designed to determine if there was a predictable relationship between saliva and plasma codeine concentrations. Drug-free volunteers (n = 17) were administered a 30-mg dose of liquid codeine phosphate. Plasma and saliva specimens were collected at various times for 24 h after administration. Plasm...

    journal_title:Journal of analytical toxicology

    pub_type: 临床试验,杂志文章

    doi:10.1093/jat/23.6.452

    authors: O'Neal CL,Crouch DJ,Rollins DE,Fatah A,Cheever ML

    更新日期:1999-10-01 00:00:00

  • Bioaccessibility of Drug Residues on Common Police Station Work Surfaces.

    abstract::The fraction of any surface-adsorbed contaminant available for absorption is considered the bioaccessible fraction. Applied previously to contaminants such as pesticides and heavy metals on surfaces such as soil, food and cosmetics, the term may also be used to describe the fraction of drug residue bound to work surfa...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/bky073

    authors: Doran GS,Howitt JA

    更新日期:2019-03-01 00:00:00

  • Disposition of heroin and its metabolites in heroin-related deaths.

    abstract::Although many deaths occur annually from heroin intoxication, the presence of heroin has not been reported in postmortem tissues. Recognizing heroin's susceptibility to rapid chemical and metabolic hydrolysis, extraction procedures were developed for the efficient recovery of heroin, 6-acetylmorphine, and morphine fro...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/18.1.22

    authors: Goldberger BA,Cone EJ,Grant TM,Caplan YH,Levine BS,Smialek JE

    更新日期:1994-01-01 00:00:00

  • Determination of pesticide metabolites in human urine using an isotope dilution technique and tandem mass spectrometry.

    abstract::A method that measures 12 analytes in urine and reflects possible exposure to pesticides was developed. The sample preparation involves enzyme hydrolysis and solvent extraction through the use of laboratory robotics, followed by phase-transfer catalysis derivatization and silica cleanup. Samples are analyzed by capill...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/19.5.323

    authors: Hill RH Jr,Shealy DB,Head SL,Williams CC,Bailey SL,Gregg M,Baker SE,Needham LL

    更新日期:1995-09-01 00:00:00

  • Gas chromatographic determination of urinary o-cresol for the monitoring of toluene exposure.

    abstract::A sensitive and reproducible gas chromatographic procedure for the quantitative determination of urinary o-cresol is described. The first step involves acid hydrolysis (2N HCl, 100 degrees C, 10 min), which yields unconjugated o-cresol. After extraction (methylene chloride, pH 2), the organic layer is concentrated by ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/20.5.309

    authors: Truchon G,Tardif R,Brodeur J

    更新日期:1996-09-01 00:00:00

  • Synthetic cannabinoids in oral fluid.

    abstract::At the end of 2010, the U.S. Drug Enforcement Administration (DEA) used its emergency scheduling authority to temporarily control five chemicals, JWH-018, JWH-073, JWH-200, CP-47497, and cannabicyclohexanol (CP-47497 C8), often referred to as "Spice", K2, or "synthetic cannabinoids" because of their reported cannabis-...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/anatox/35.7.424

    authors: Coulter C,Garnier M,Moore C

    更新日期:2011-09-01 00:00:00

  • Closed cup vapor systems in percutaneous exposure studies: what is the dose?

    abstract::Percutaneous vapor dosing studies have generally used saturated vapor concentration (SVC) measurements to estimate the exposure dose (Ct) of vapor produced from a volatile liquid within a closed system. The purpose of this study was to clarify whether the assumption was valid when translated to a biological system (pi...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/30.3.165

    authors: Dalton CH,Maidment MP,Jenner J,Chilcott RP

    更新日期:2006-04-01 00:00:00

  • Bone surface and whole bone as biomarkers for acute fluoride exposure.

    abstract::This study compares fluoride concentrations ([F]) in surface and whole bone for up to 27 days following an acute oral dose of F. Four groups of rats received single oral F dose (50 mg/kg body weight), and the control group received deionized water (n = 10/group). Groups were euthanized at 1, 3, 9, or 27 days after F a...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/29.8.810

    authors: Buzalaf MA,Caroselli EE,de Carvalho JG,de Oliveira RC,da Silva Cardoso VE,Whitford GM

    更新日期:2005-11-01 00:00:00

  • Gas chromatographic-mass spectrometric determination of british anti-lewisite in plasma.

    abstract::British anti-Lewisite (BAL) (2,3-dimercapto-1-propanol) is a potential therapeutic compound when used against the effects of cutaneous sulfur mustard, and a method for its determination in plasma has been developed. BAL and the internal standard (IS) ethane dithiol were isolated from plasma samples through solid-phase...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/28.5.384

    authors: Byers CE,Holloway ER,Korte WD,Smith JR,Clarkson ED,Platoff GE,Capacio BR

    更新日期:2004-07-01 00:00:00

  • Fatal propafenone overdoses: case reports and a review of the literature.

    abstract::First synthesized in 1970, propafenone is a frequently used 1C antiarrhythmic drug metabolized into two major metabolites, 5-hydroxypropafenone and norpropafenone. Paradoxically, fatal intoxication is rarely described, and only six cases have been reported in the literature. We report our experience with two patients ...

    journal_title:Journal of analytical toxicology

    pub_type: 杂志文章

    doi:10.1093/jat/27.8.595

    authors: Clarot F,Goullé JP,Horst M,Vaz E,Lacroix C,Proust B

    更新日期:2003-11-01 00:00:00