Abstract:
:Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to investigate the effects of polishing on the surface properties such as surface roughness (Ra), dynamic hardness, and elastic modulus of high-rigidity glass-fiber-reinforced thermoplastics (GFRTPs) composed of E-glass fibers and polypropylene for NMCDs. The Ra values of the GFRTPs after polishing were significantly lower than those before polishing. The values were close to the Ra threshold level of 0.2, which corresponds to an acceptable surface smoothness for denture base materials. Polishing did not significantly change the dynamic hardnesses and elastic moduli of the GFRTPs. The fiber loading did not greatly affect the micromechanical properties of the GFRTPs because the glass-fiber reinforcement is embedded in the polypropylene matrix.
journal_name
Dent Mater Jjournal_title
Dental materials journalauthors
Tanimoto Y,Nagakura Mdoi
10.4012/dmj.2018-012subject
Has Abstractpub_date
2018-11-30 00:00:00pages
1017-1022issue
6eissn
0287-4547issn
1881-1361journal_volume
37pub_type
杂志文章abstract::The purpose of this study was to characterize the surface damages of zirconia by Nd:YAG dental laser irradiation through a systematic evaluation of the associated microstructural changes. Disk specimens of yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) and ceria-stabilized zirconia/alumina nanocomposite (C...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2009-127
更新日期:2010-10-01 00:00:00
abstract::The human antimicrobial peptide beta-defensin-2 (hBD2) shows broad antibacterial activity and infrequent bacterial resistance. Here mesoporous bioactive glass (MBG) was loaded with hBD2, forming hBD2-loaded MBG (BD-MBG). The antibacterial and osteogenic effects of BD-MBG were investigated in comparison with MBG and th...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2020-105
更新日期:2020-12-24 00:00:00
abstract::Comparative studies on two-body sliding wear resistance were performed between a hybrid composite resin and conventional light-curing composite veneering materials. This study investigated the wear resistance of hybrid composite resins compared with three composite resin veneering materials for 12%Au-Ag-Pd alloy, the ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.21.225
更新日期:2002-09-01 00:00:00
abstract::This study investigated transformations of nickel-titanium wires using differential scanning calorimetry (DSC) and thermomechanical analysis (TMA) under tensile load (100 gf or 500 gf). Two nickel-titanium wires, 35°C Copper Ni-Ti and Nitinol SE, were selected. DSC analyses were performed between -90° and 100°C. Speci...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2010-196
更新日期:2011-01-01 00:00:00
abstract::The blending effect (BE) plays an important role in esthetics of the composite resin. The objective of this study was to determine the extents to which filler size and content affect the BE. Three types of fillers (0.7, 1.0, and 1.5 µm) were mixed at weight contents of 60, 70, 75, and 80%. This study simulated clinica...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2016-083
更新日期:2017-01-31 00:00:00
abstract::The behavior of microencapsulated polymerization initiators in dental adhesives is unknown. This study investigated the effects of new microencapsulated initiators in novel, multi-purpose, PMMA-type adhesive resin on the bonding performance and polymerization reactivity. Microencapsulated BPO and 1,3,5-trimethylbarbit...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.27.35
更新日期:2008-01-01 00:00:00
abstract::The aim of this study was to clarify the effect of heating rate on the development of both transient and residual stresses in investment molds. Solid, cylindrical, gypsum-based molds were modeled and theoretical calculations made of temperature distributions with a constant heating rate. These calculations used experi...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.15.121
更新日期:1996-12-01 00:00:00
abstract::Multi-purpose bonding performance of three kinds of newly synthesized phosphonic acid monomers was investigated. Methacryloxyalkyl or acryloxyalkyl phosphonoacetates of 6-MHPA, 6-AHPA, 10-MDPA were synthesized in 42.8-51.9% yields with a light yellow viscous liquid, and identified as new compounds by 1H NMR, IR, and e...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.26.105
更新日期:2007-01-01 00:00:00
abstract::The purpose of this study was to evaluate the effects of ultrasonic and manual placement techniques on the push-out bond strength of Biodentine and MTA with and without calcium chloride. One hundred and twenty mid-root slices from forty freshly extracted single-rooted human mandibular premolar teeth were instrumented ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2016-094
更新日期:2016-10-01 00:00:00
abstract::To evaluate the effect of a dentin adhesive on sclerotic dentin, contraction gap width and shear bond strength were measured. Dentin cavity wall was pretreated with an experimental dentin bonding system with and without a dentin primer, or with a commercial dentin bonding system. In the experimental dentin bonding gro...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.25.576
更新日期:2006-09-01 00:00:00
abstract::The aim of this in vitro study was to evaluate the pH value of intact and carious dentin in primary teeth using a pH-imaging microscope (SCHEM-100, HORIBA Ltd., Kyoto, Japan). Bucco-lingual cut sections of extracted human primary teeth, which had either mild or severe dentinal caries lesions, were placed on the pH-ima...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.23.628
更新日期:2004-12-01 00:00:00
abstract::The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a newly developed resin cement, ECD-89 (ECD, Tokuyama Dental, Tokyo, Japan) to dentin and to observe the interfacial micromorphology by comparing with two commercial resin cements, Multilink Automix (MA, Ivoclar Vivadent AG, Schaan, Lie...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2014-122
更新日期:2015-01-01 00:00:00
abstract::The present study investigated the influences of a denture strengthener on the deformation of a maxillary complete denture. Three groups of maxillary complete dentures were fabricated (Group 1 without a strengthener; Group 2 with a Co-Cr alloy wire strengthener; Group 3 with an experimental fiberglass strengthener). T...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.28.507
更新日期:2009-07-01 00:00:00
abstract::The aim of this study was to investigate the effects of potassium fluoride (KF) and sodium fluoride (NaF) in different concentrations on micro-shear bond strength (µSBS) and their protective effects against acid. The enamel blocks were treated with several concentrations of KF and NaF. For µSBS, Clearfil SE Bond 2 was...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2020-019
更新日期:2020-10-27 00:00:00
abstract::To elucidate the mechanism of dimensional changes in alginate impression in solutions, the relationship between the ion concentrations in three types of solutions (nonelectrolyte and monovalent and divalent metallic salts) and change in gel volume was examined. The gel in the monovalent metallic salt solution expanded...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.19.396
更新日期:2000-12-01 00:00:00
abstract::This study aimed to determine the influence of sodium hypochlorite (NaOCl) contamination on the microhardness of build-up composites. Fifty-two samples, from each of three build-up materials (LuxaCore Dual, MultiCore flow and Rebilda DC) were prepared. Half of the samples from each material were stored in physiologic ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2010-007
更新日期:2010-08-01 00:00:00
abstract::High-power light-curing units have emerged that reduce the time of procedures in dental clinical work. However, patients sometimes complain of pain during the polymerization of composite resin. In this experiment, we investigated how differences in light-curing mode affect the temperature rise during composite resin p...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2018-158
更新日期:2019-07-31 00:00:00
abstract::The aim of this study was to evaluate the pH at the surface of active or arrested carious dentin using a micro pH sensor, and to compare the relationship between different pH measurement techniques. Twenty extracted carious teeth were divided into two groups, active or arrested caries, according to predefined clinical...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.25.423
更新日期:2006-09-01 00:00:00
abstract::This study evaluated the effects of ceramic surface treatment agents on shear bond strengths to ceramic materials with and without thermocycling. Ceramic plates were prepared from feldspathic ceramic; AAA, lithium disilicate ceramic material; IPS e.max Press, zirconia ceramic; Lava. Ceramic surfaces were pretreated wi...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2016-383
更新日期:2017-11-29 00:00:00
abstract::This in vitro study aimed to evaluate the effect of two different polymer-based CAD/CAM materials; resin-nano ceramic (Lava Ultimate [LVU]) and composite (CERASMART [CS]), their different surface pre-treatments, and use of different resin cements on the µTBS of adhesively bonded CAD/CAM onlays to dentin. CAD/CAM mater...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2017-442
更新日期:2019-02-08 00:00:00
abstract::The cream type of denture adhesives after use cannot be easily removed from oral mucosa and have the potential risk to change the oral flora. The effects of the temperature-responsive hydrogel Pluronic F-127 (PF) on the complex viscosity of denture adhesives were evaluated. Carboxy methylcellulose (CMC) mass fractions...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2015-191
更新日期:2016-01-01 00:00:00
abstract::A new type of self-etching agent, the single-step adhesive, was developed. The purpose of this study was to investigate the difference in the ultrastructural features of enamel and dentin surfaces following application of the prototype single-step adhesive (EXM618, 3M, MN, USA). Extracted caries-free human premolars w...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.23.321
更新日期:2004-09-01 00:00:00
abstract::This study evaluated the irrigation extrusion and smear layer (SL) removal of continuous ultrasonic irrigation (CUI). Forty root canals were shaped, embedded in warm sterile saline agar colored with 1% acid red, and distributed into four groups; three groups had the final irrigation sequence of sodium hypochlorite and...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2016-411
更新日期:2018-01-30 00:00:00
abstract::Novel fast-setting calcium silicate cement with fluoride (CSC) has been developed for potential applications in tooth crown. The aim of this study was to test the diametral tensile strength (DTS) of different CSC compositions in humid condition on day1, 28, and 180. We tested 'bond CSC' with 3.5% fluoride and no radio...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2015-390
更新日期:2016-01-01 00:00:00
abstract::The diamond burs of two dental CAD/CAM systems (GN and CD) were examined if they could be used to fabricate up to 21 ceramic full crowns without fracture. After one, 11, and 21 machining times, the surfaces of the diamond burs were observed and the number of particles captured on SEM pictures was counted. The average ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.24.134
更新日期:2005-03-01 00:00:00
abstract::The aim was to investigate the effect of simulated low-temperature degradation (s-LTD) and hydrothermal fatigue on the degradation of three ZrO(2)-based dental materials. Lava, IPS, and NanoZr discs were randomly assigned to (1) Control-Storage in distilled water at 37°C; (2) Aging at 134°C for 5 h (s-LTD); (3) Thermo...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2011-216
更新日期:2012-01-01 00:00:00
abstract::The aim of this study was to investigate the diffusion of red-stained experimental GM primer and blue-stained dentin bonding agent into EDTA-conditioned dentin and the effect of GM priming on contraction gap formation. After GM priming at 0, 35, 70, or 100 vol%, marginal adaptation was evaluated by measuring the wall-...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2009-084
更新日期:2010-10-01 00:00:00
abstract::In this study, effects of the degree of dissociation of acids on the hydrolysis rate of methoxy group in γ-methacryloxypropyltrimethoxysilane (γ-MPS) and the adsorption characteristics of γ-MPS on ceramic surfaces were studied using acetic, phosphoric, and hydrochloric acids. Hydrolytic stability of γ-MPS adsorption l...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2013-319
更新日期:2014-01-01 00:00:00
abstract::The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.28.307
更新日期:2009-05-01 00:00:00
abstract::This study evaluated the influence of heat treatment (HT) of the silane on the microtensile bond strength of resin cement to a feldspathic ceramic. Ceramic (VITA VM7) and composite blocks (N=32) were divided into four groups (n=6 for bond test, n=2 for SEM) at random and subject to following sequence of conditioning: ...
journal_title:Dental materials journal
pub_type: 杂志文章,随机对照试验
doi:
更新日期:2011-01-01 00:00:00