An ultrastructural analysis of the prototype single-step adhesive applied on enamel and dentin surfaces.

Abstract:

:A new type of self-etching agent, the single-step adhesive, was developed. The purpose of this study was to investigate the difference in the ultrastructural features of enamel and dentin surfaces following application of the prototype single-step adhesive (EXM618, 3M, MN, USA). Extracted caries-free human premolars were used in this study. Occlusal enamels of teeth--to be used as cut surface specimens--were removed perpendicular to the long axis of the specimens. The mesial and distal surfaces of these teeth, on the other hand, were used as uncut surface specimens in the test. In addition, Mega Bond (Kuraray Medical Inc., Tokyo, Japan) and Xeno CFII Bond (Dentsply Sankin, Tokyo, Japan) were used as controls. After covering half of the tooth surfaces with nail varnish (for control), the other half of each surface was treated with one of the three test adhesives--EXM618, Mega Bond, or Xeno CFII Bond--according to the manufacturer's recommendations. Conditioned enamel and dentin surfaces (i.e., decalcified depth and rugged surface) were observed with a scanning confocal laser microscope (SCLM 1100, Olympus, Tokyo, Japan; henceforth abbreviated as SCLM). Based on the findings of this study, the prototype single-step adhesive EXM618 appears to be suitable for use in dental clinics.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Han L,Cruz E,Fukushima M,Okamoto A,Okiji T

doi

10.4012/dmj.23.321

keywords:

subject

Has Abstract

pub_date

2004-09-01 00:00:00

pages

321-8

issue

3

eissn

0287-4547

issn

1881-1361

journal_volume

23

pub_type

杂志文章
  • Evaluation of resin infiltration on demineralized root surface: An in vitro study.

    abstract::The aim of this study was to evaluate the effect of resin infiltration on root caries induced by Streptococcus mutans biofilms. Human premolar specimens were divided to 5 groups: negative control (NC), Clearfil SE Bond (SEB), Icon-etch120s+Icon-infiltrant (HA120), Icon-etch10s+Icon-infiltrant (HA10) and K-etchant10s+I...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-229

    authors: Zhou Y,Matin K,Shimada Y,Sumi Y,Tagami J

    更新日期:2017-03-31 00:00:00

  • Influence of a propolis-based irrigant solution on gap formation and bond strength of posts bonded to root canal dentin using different resin cements.

    abstract::This study evaluated the influence of an aqueous propolis-based solution (PROP) on gap formation and bond strength of posts bonded to root canal dentin using resin cements. Endodontically-treated bovine incisors received different irrigation protocols: 1) 2.5% sodium hypochlorite (NaOCl)/17% EDTA/NaOCl; 2) saline solu...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-111

    authors: Matochek MHM,Tomaz PLS,Oliveira TS,Polassi MR,Alonso RCB,Scremin FM,Sauro S,Marcucci MC,D'Alpino PHP

    更新日期:2020-06-05 00:00:00

  • Effects of CO2 laser irradiation combined with fluoride application on the demineralization, mechanical properties, structure, and composition of enamel.

    abstract::We investigated the effects of CO2 laser irradiation combined with acidulated phosphate fluoride (APF) application on the demineralization of enamel. APF gel was applied to the buccal enamel of human premolars and CO2 laser was applied. After the specimens were immersed in demineralization solution for 72 h, they were...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-225

    authors: Nakagaki S,Iijima M,Endo K,Saito T,Mizoguchi I

    更新日期:2015-01-01 00:00:00

  • Analysis of fracture surface of titanium-porcelain bonding by electron spectroscopy for chemical analysis.

    abstract::Three commercially available porcelains bonded to titanium were evaluated to determine the weakest zone of the titanium-porcelain bonding structures. Tensile bond tests were performed for these specimens (NO, DU, and VI) and for Ni-Cr alloy-porcelain bonding samples that served as controls. The maximum bond strengths ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-263

    authors: Kannari Y,Endo K,Ida Y,Ochi M,Ohno H

    更新日期:2014-01-01 00:00:00

  • Transformation behavior of nickel-titanium orthodontic wires under tensile load.

    abstract::This study investigated transformations of nickel-titanium wires using differential scanning calorimetry (DSC) and thermomechanical analysis (TMA) under tensile load (100 gf or 500 gf). Two nickel-titanium wires, 35°C Copper Ni-Ti and Nitinol SE, were selected. DSC analyses were performed between -90° and 100°C. Speci...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-196

    authors: Iijima M,Ohta M,Brantley WA,Naganishi A,Murakami T,Muguruma T,Mizoguchi I

    更新日期:2011-01-01 00:00:00

  • Anti-demineralization characteristics of surface pre-reacted glass-ionomer (S-PRG) filler-containing varnishes.

    abstract::This study investigated the anti-demineralization effects of surface pre-reacted glass-ionomer (S-PRG) filler-containing varnishes. Thirty-five bovine root specimens were divided into five treatment groups, with seven specimens each coated with 1) MI varnish (MIV), 2) F varnish (FV), 3) PRG varnish I (PV), 4) PRG varn...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-396

    authors: Shiiya T,Kataoka A,Tomiyama K,Fujino F,Mukai Y

    更新日期:2020-11-11 00:00:00

  • Contraction gap versus shear bond strength of dentin adhesive in sound and sclerotic dentins.

    abstract::To evaluate the effect of a dentin adhesive on sclerotic dentin, contraction gap width and shear bond strength were measured. Dentin cavity wall was pretreated with an experimental dentin bonding system with and without a dentin primer, or with a commercial dentin bonding system. In the experimental dentin bonding gro...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.576

    authors: Kusunoki M,Itoh K,Takahashi Y,Hisamitsu H

    更新日期:2006-09-01 00:00:00

  • Antimicrobial and antifungal effects of tissue conditioners containing a photocatalyst.

    abstract::This study examined the antimicrobial/antifungal ability of a tissue conditioner containing a photocatalyst for Escherichia coli, Streptococcus mutans, Staphylococcus aureus and Candida albicans. The photocatalyst was mixed with tissue conditioners powders at concentrations of 0, 10, 15, and 20 wt%. Tissue conditioner...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-203

    authors: Uchimaru M,Sakai T,Moroi R,Shiota S,Shibata Y,Deguchi M,Sakai H,Yamashita Y,Terada Y

    更新日期:2011-01-01 00:00:00

  • Bilinear elastic property of the periodontal ligament for simulation using a finite element mandible model.

    abstract::This study aimed to introduce a procedure for determining the bilinear elastic moduli (E1 and E2) of the periodontal ligament for a mathematical tooth model to analyse stress in the mandible. The bone and tooth morphology were scanned from a dry skull and an extracted intact tooth, respectively, and reconstructed in a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-170

    authors: Borák L,Florian Z,Bartáková S,Prachár P,Murakami N,Ona M,Igarashi Y,Wakabayashi N

    更新日期:2011-01-01 00:00:00

  • Fabrication of all-ceramic crowns by a new method.

    abstract::A new method of all-ceramic production using alumina coping has been developed. The present study investigates the influence of secondary firing (glass infiltration firing) conditions. Samples of porcelain build-up without secondary firing were also assessed. The suitability of coping that included secondary firing wa...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-275

    authors: Masuda T,Kakimoto K,Takahashi K,Komasa Y

    更新日期:2016-01-01 00:00:00

  • Light activated resin containing organic dyestuff.

    abstract::The physical properties of experimental visible light-activated resins containing dyestuff, which could be quickly discolored by irradiation was, evaluated by analyzing light absorbance characteristics and measuring micro Vickers hardness. The experimental resin, which was prepared by mixing equivalent weights of Bis ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.147

    authors: Nakazato J,Itoh K,Wakumoto S

    更新日期:1989-12-01 00:00:00

  • The protective effect of resveratrol against dentin bonding agents-induced cytotoxicity.

    abstract::This study was designed to evaluate the cytotoxicity of four dentin bonding agents and the effects of an antioxidant addition. Group A: G-aenial Bond, Group B: Optibond All in One, Group C: Gluma Self Etch and Group D: Clearfil S(3) Bond were added to the medium using extract method. The cells were cultured with or wi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-079

    authors: Atalayin C,Armagan G,Konyalioglu S,Kemaloglu H,Tezel H,Ergucu Z,Keser A,Dagci T,Onal B

    更新日期:2015-01-01 00:00:00

  • SEM observation of collagen fibrils secreted from the body surface of osteoblasts on a CO3apatite-collagen sponge.

    abstract::The secretion of collagen by osteoblasts was observed by scanning electron microscopy (SEM). Osteoblast-like cells were cultured on a CO3apatite-collagen sponge reinforced with a porous HAp frame. After three days' incubation, a number of newly created matrix fibrils, forming a network structure, were observed at the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.460

    authors: Hirata I,Nomura Y,Tabata H,Miake Y,Yanagisawa T,Okazaki M

    更新日期:2005-09-01 00:00:00

  • Temperature dependence of thermal expansion coefficient for palladium-based binary alloy.

    abstract::Temperature dependencies of thermal expansion coefficients for the alloys of Pd-Ag, Pd-Cu and Pd-Co binary systems were measured at temperatures up to 900 degrees C, with heating and cooling rates of 5 degrees C/min. The coefficient of thermal expansion of alloys with no transformation in the temperature range of inte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.9.47

    authors: Asaoka K,Kuwayama N

    更新日期:1990-06-01 00:00:00

  • Stress distribution in tooth resin core build-ups with different post-end positions in alveolar bone level under two kinds of load directions.

    abstract::This study aimed to evaluate influence of different post-end positions in alveolar bone level on stress distributions in resin-core build-up tooth under different load directions. Three-dimensional mathematical models of a root-filled mandibular premolar tooth were constructed. Resin post and core were built-up with s...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-160

    authors: Hatayama T,Chiba A,Kainose K,Nakajima M,Hosaka K,Wakabayashi N,Foxton RM,Tagami J

    更新日期:2018-06-08 00:00:00

  • Evaluation of an articulated measuring apparatus for use in the oral cavity.

    abstract::The aim of this study was to evaluate the trial Teaching Robot for the development of a contact-type measuring apparatus for using directly in the oral cavity. A standard model was used to mimic the dentition by placing an arrangement of three bearing balls. The diameters of the balls were measured. A practical dentit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.168

    authors: Maikuma Y,Usui K,Araki K,Mataki S,Kurosaki N,Furuya N

    更新日期:2003-06-01 00:00:00

  • Mechanical properties and radiopacity of flowable fiber-reinforced composite.

    abstract::The aim was to evaluate the effect of different zirconia discontinuous fiber fractions on radiopacity and other selected properties of glass discontinuous fiber-reinforced flowable composite (Exp-SFRC). Exp-SFRC was prepared by mixing 30 wt% of resin-matrix and 45 wt% of particulate-fillers to 25 wt% of various weight...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-102

    authors: Garoushi S,Vallittu P,Lassila L

    更新日期:2019-03-31 00:00:00

  • Effect of commercially available bonding agents impregnated with fibers on bending strength of hybrid resin.

    abstract::To clarify the mechanical properties of fiber-reinforced hybrid resin bridges, this study evaluated the influence of various bonding agents ((Modeling Liquid (ML), DE Resin (DE), Bell Bond (BE), Mega Bond (MG), Durafil Bond (DU), Fluoro Bond (FB), Mac-Bond (MC), EG Bond (EG), Unifill Bond (UN), Single Bond (SN)) impre...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.723

    authors: Tsushima S,Gomi H,Shinya A,Yokoyama D,Vallittu PK,Shinya A

    更新日期:2008-09-01 00:00:00

  • Pre-treatment of radicular dentin by self-etch primer containing chlorhexidine can improve fiber post bond durability.

    abstract::We evaluated whether the pre-treatment of radicular dentin by ED Primer containing different concentrations of chlorhexidine can improve the bond durability of fiber post to radicular dentin. Experimental ED primers containing different concentrations of chlorhexidine (0%, 0.5% and 1.0%) were prepared. Thirty extracte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-134

    authors: Zhou J,Yang X,Chen L,Liu X,Ma L,Tan J

    更新日期:2013-01-01 00:00:00

  • Flexural properties of three kinds of experimental fiber-reinforced composite posts.

    abstract::The aim of this study was to estimate the flexural properties of three kinds of experimental fiber-reinforced composite (FRC) posts and to evaluate their potential use as posts. Experimental FRC posts were fabricated with glass, aramid, and UHMWP fibers. Commercial FRC posts were used for comparison. A three-point ben...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-053

    authors: Kim MJ,Jung WC,Oh S,Hattori M,Yoshinari M,Kawada E,Oda Y,Bae JM

    更新日期:2011-01-01 00:00:00

  • Relation between attractive force and keeper surface characteristics of iron-neodymium-boron magnetic attachment systems.

    abstract::The purpose of this study was to evaluate the influence of heating, cast bonding, and subsequent polishing procedures on attractive force of magnetic attachments. Two magnetic attachment systems with keepers of different chemical compositions (Hicorexslim 3013, 447J1; Magfit EX400, AUM20) were employed. Keepers examin...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.393

    authors: Ohashi N,Koizumi H,Ishikawa Y,Furuchi M,Matsumura H,Tanoue N

    更新日期:2007-05-01 00:00:00

  • Fracture force for veneered materials on restorations measured by torsion testing.

    abstract::The torsional fracture strength at the interface between a base plate and veneering material was evaluated for three kinds of veneered restoration: porcelain fused to zirconia (PFZ), porcelain fused to metal (PFM), and composite resin veneered metal (CRVM). The metal and zirconia base plate (30×4×0.4 mm) were prepared...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-432

    authors: Watanabe F,Seto M,Ueda K,Ozawa M

    更新日期:2018-07-29 00:00:00

  • Ultrasonic investigation of the effect of S-PRG filler-containing coating material on bovine tooth demineralization.

    abstract::This study investigated the effect of a coating material containing S-PRG fillers on the demineralization of bovine enamel and dentin, by measuring changes in the transmitted ultrasonic velocity. Bovine enamel and dentin specimens with and without coating (n=6 for each condition) were cut into blocks, immersed in 0.1 ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-153

    authors: Murayama R,Furuichi T,Yokokawa M,Takahashi F,Kawamoto R,Takamizawa T,Kurokawa H,Miyazaki M

    更新日期:2012-01-01 00:00:00

  • Correlation in the mechanical properties of acrylic denture base resins.

    abstract::The aim of the present study was to measure various mechanical properties of acrylic denture base resins, including flexural modulus, flexural strength, fracture toughness, Barcol and Vickers hardness and their related properties, and to investigate correlations between different mechanical properties. Resin specimens...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-205

    authors: Lee HH,Lee CJ,Asaoka K

    更新日期:2012-02-03 00:00:00

  • Water durability of resin bond to pure gold treated with various adhesion promoting thiirane monomers.

    abstract::Adhesion promoting monomers for precious metals, 2,3-epithiopropyl methacrylate (EP1MA), 4,5-epithiopentyl methacrylate (EP3MA), 9,10-epithiodecyl methacrylate (EP8MA), 10,11-epithioundecyl methacrylate (EP9MA), 9,10-epithiodecyl 4-vinylbenzoate (EP8VB), 2,3-epithiocyclohexyl methacrylate (EPCHMA), and 3,4-epithiobuty...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.29

    authors: Kadoma Y,Kojima K,Tamaki Y,Nomura Y

    更新日期:2007-01-01 00:00:00

  • Effect of monomer structure on the mechanical properties of light-cured composite resins.

    abstract::The effects of monomer structure on the mechanical properties of visible light-cured composite resins based on the seven types of aromatic dimethacrylates were investigated. The results of this study suggested that the mechanical properties of the composite resins were dependent upon the chemical structure of the dime...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.40

    authors: Kawaguchi M,Fukushima T,Horibe T

    更新日期:1989-06-01 00:00:00

  • Measurement of the remaining dentin thickness using optical coherence tomography for crown preparation.

    abstract::This study aimed to investigate the maximum depth imaging and optical properties of the dentin near the pulp by using optical coherence tomography (OCT) and to explore the possibility of measuring the remaining dentin thickness (RDT). Human third molars were used. In experiment 1, the cuspal dentin blocks (0.50-mm to ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-303

    authors: Fujita R,Komada W,Nozaki K,Miura H

    更新日期:2014-01-01 00:00:00

  • Shear bond strengths of a single-step bonding system to enamel and dentin.

    abstract::An experimental primer was developed as a single-step bonding system for resin-modified glass ionomer cements (GIC). Efficacy of this primer on adhesion of resin-modified GICs and resin composite to enamel and dentin was evaluated by shear bond test and SEM observation. Good bond strengths to enamel were obtained (> 1...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.16.40

    authors: Nikaido T,Nakajima M,Higashi T,Kanemura N,Pereira PN,Tagami J

    更新日期:1997-06-01 00:00:00

  • Effects of attrition, prior acid-etching, and cyclic loading on the bond strength of a self-etching adhesive system to dentin.

    abstract::The purpose of this study was to evaluate the effects of dentin attrition, phosphoric acid etching, and cyclic loading on the microtensile bond strength (microTBS) of a self-etching adhesive system to dentin. Flat dentin surfaces of human molars were assigned to eight experimental groups based on those with or without...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.28.197

    authors: Shinkai K,Ebihara T,Shirono M,Seki H,Wakaki S,Suzuki M,Suzuki S,Katoh Y

    更新日期:2009-03-01 00:00:00

  • Initial and long-term bond strengths of one-step self-etch adhesives with silane coupling agent to enamel-dentin-composite in combined situation.

    abstract::This study evaluated the effect of adding silane coupling agent on initial and long-term bond strengths of one-step self-etch adhesives to enamel-dentin-composite in combined situation. Cervical cavities were prepared on extracted molars and filled with Clearfil AP-X. After water-storage for one-week, the filled teeth...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-050

    authors: Mamanee T,Takahashi M,Nakajima M,Foxton RM,Tagami J

    更新日期:2015-01-01 00:00:00