Transformation behavior of nickel-titanium orthodontic wires under tensile load.

Abstract:

:This study investigated transformations of nickel-titanium wires using differential scanning calorimetry (DSC) and thermomechanical analysis (TMA) under tensile load (100 gf or 500 gf). Two nickel-titanium wires, 35°C Copper Ni-Ti and Nitinol SE, were selected. DSC analyses were performed between -90° and 100°C. Specimens prepared for TMA were approximately 150 µm thick and 12 mm long. TMA analyses were performed between -120° and 100°C. With TMA, all transformation temperatures for a tensile load of 500 gf, obtained from both the heating and cooling curves, were higher than those for a tensile load of 100 gf. While mean A(s) and A(f) temperatures for Copper Ni-Ti obtained by TMA were much higher than those obtained by DSC analysis, mean M(s) and M(f) temperatures obtained by TMA were much lower than those obtained by DSC analysis. The transformation behavior of nickel-titanium wires with change in temperature was affected by application of tensile load.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Iijima M,Ohta M,Brantley WA,Naganishi A,Murakami T,Muguruma T,Mizoguchi I

doi

10.4012/dmj.2010-196

subject

Has Abstract

pub_date

2011-01-01 00:00:00

pages

398-403

issue

3

eissn

0287-4547

issn

1881-1361

pii

JST.JSTAGE/dmj/2010-196

journal_volume

30

pub_type

杂志文章
  • Effects of incorporation of nano-fluorapatite particles on microhardness, fluoride releasing properties, and biocompatibility of a conventional glass ionomer cement (GIC).

    abstract::Present study evaluated effects of addition of Nanoparticles fluorapatite (Nano-FA) on microhardness and fluoride release of a Glass Ionomer Cement (GIC, Fuji IX GP Fast). Forty-eight specimens prepared, divided equally into 4 groups (2 with Nano-FA); after 24 h and one week Vickers microhardness (HV) was measured. Na...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-437

    authors: Moshaverinia M,Borzabadi-Farahani A,Sameni A,Moshaverinia A,Ansari S

    更新日期:2016-01-01 00:00:00

  • Long-term clinical and radiographic evaluation of the effectiveness of direct pulp capping materials: A meta-analysis.

    abstract::The aim of this review is to evaluate the long-term effectiveness of calcium silicate-based cement (CS) and calcium hydroxide (CH) for direct pulp capping (DPC) to human pulp-exposed permanent teeth. An electronic search and manual search were performed on 21 June 2019. Long-term clinical and radiographic evaluations ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-043

    authors: Matsuura T,Ziauddin SM,Kawata-Matsuura VKS,Sugimoto K,Yamada S,Yoshimura A

    更新日期:2020-10-01 00:00:00

  • Effect of aluminoborate whiskers on mechanical properties of polycarboxylate cements.

    abstract::The mechanical properties of polycarboxylate cements containing 20 mass% of four kinds of aluminoborate whiskers with different fiber lengths and diameters were evaluated. Bending strength of the cements increased with increase in fiber length, whereby the strength of the cement with the longest fiber was about two ti...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.561

    authors: Kurata S,Umemoto K

    更新日期:2008-07-01 00:00:00

  • Retention force of complete palate coverage and palate-less dentures in vitro.

    abstract::The purpose of this study was to investigate the retention force of complete palate coverage and palate-less dentures made with three polymerization systems (DS system, SR-Ivocap system, microwave polymerization system) in vitro. The retention force between each denture and a polyurethane model by intervening artifici...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.19

    authors: Teraoka F,Nakagawa M,Takahashi J

    更新日期:2004-03-01 00:00:00

  • Modification of electrochemically deposited apatite using supercritical water.

    abstract::Supercritical water was used as a modification method of electrochemically deposited apatite on pure titanium. The apatites were coated on a commercially pure titanium plate using a hydrothermal-electrochemical method. A constant direct current at 12.5 mA/cm2 was loaded for 1 hr at 25, 60, 100, 150 and 200 degrees C i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.247

    authors: Ban S,Hasegawa J

    更新日期:2001-12-01 00:00:00

  • Structure-property relation of a soft liner material used in denture applications.

    abstract::With a view to understanding the structure-property relation of a silicone-based soft lining denture material after polymerization, its chemical composition and viscoelastic properties were investigated. Chemical compositions of the cured and uncured polymers of a commercial silicone permanent soft liner were determin...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:

    authors: Doğan OM,Keskin S,Doğan A,Ataman H,Usanmaz A

    更新日期:2007-05-01 00:00:00

  • Cold plasma-induced surface modification of heat-polymerized acrylic resin and prevention of early adherence of Candida albicans.

    abstract::Atmospheric-pressure cold plasma was applied to process the surface of heat-polymerized acrylic resin. Changes to the physical properties and early adherence of Candida albicans were investigated. Alternating current cold plasma with Ar/O2 as working gas was used. Scanning electron microscopy (SEM) and X-ray photoelec...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-035

    authors: Pan H,Wang G,Pan J,Ye G,Sun K,Zhang J,Wang J

    更新日期:2015-01-01 00:00:00

  • Effect of monomer structure on the mechanical properties of light-cured composite resins.

    abstract::The effects of monomer structure on the mechanical properties of visible light-cured composite resins based on the seven types of aromatic dimethacrylates were investigated. The results of this study suggested that the mechanical properties of the composite resins were dependent upon the chemical structure of the dime...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.40

    authors: Kawaguchi M,Fukushima T,Horibe T

    更新日期:1989-06-01 00:00:00

  • Temperature dependence of thermal expansion coefficient for palladium-based binary alloy.

    abstract::Temperature dependencies of thermal expansion coefficients for the alloys of Pd-Ag, Pd-Cu and Pd-Co binary systems were measured at temperatures up to 900 degrees C, with heating and cooling rates of 5 degrees C/min. The coefficient of thermal expansion of alloys with no transformation in the temperature range of inte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.9.47

    authors: Asaoka K,Kuwayama N

    更新日期:1990-06-01 00:00:00

  • Initial attachment of human oral keratinocytes cultured on zirconia or titanium.

    abstract::Initial attachment of human oral keratinocytes (HOKs) cultured on mirror-surfaced commercially pure titanium (Ti) or yttria-stabilized tetragonal zirconia polycrystals (TZP) was investigated. Numbers of viable attached HOKs, their mRNAs and proteins expression of laminin γ2 and integrin β4 were evaluated using the WST...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-189

    authors: Kimura Y,Matsuzaka K,Yoshinari M,Inoue T

    更新日期:2012-01-01 00:00:00

  • Repair bond strength of bulk-fill resin composite: Effect of different adhesive protocols.

    abstract::This study evaluated the effect of different adhesive protocols on the shear bond strength (SBS) of bulk-fill resin composite repaired with bulk-fill or conventional composite. Cylindrical bulk-fill resin composite specimens were prepared and allocated into groups according to the bonding strategy: no treatment, Silan...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-291

    authors: Cuevas-Suárez CE,Nakanishi L,Isolan CP,Ribeiro JS,Moreira AG,Piva E

    更新日期:2020-03-31 00:00:00

  • The hydration chemistry of ProRoot MTA.

    abstract::'Tooth-coloured' ProRoot MTA is an endodontic cement comprising an 80:20 wt% mixture of white Portland cement (WPC) and bismuth oxide. The setting reactions within this cement system are not currently well understood. Accordingly, this research monitors the early hydration chemistry of ProRoot MTA by X-ray diffraction...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-309

    authors: Li Q,Coleman NJ

    更新日期:2015-01-01 00:00:00

  • Effects of potassium and sodium fluoride in different concentrations on micro-shear bond strength and inhibition of demineralization.

    abstract::The aim of this study was to investigate the effects of potassium fluoride (KF) and sodium fluoride (NaF) in different concentrations on micro-shear bond strength (µSBS) and their protective effects against acid. The enamel blocks were treated with several concentrations of KF and NaF. For µSBS, Clearfil SE Bond 2 was...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-019

    authors: Al-Qahtani A,Inoue G,Abdou A,Nikaido T,Tagami J

    更新日期:2020-10-27 00:00:00

  • Effect of air abrasion and thermocycling on resin adaptation and shear bond strength to dentin for an etch-and-rinse and self-etch resin adhesive.

    abstract::This study examined the effect of air abrasion and thermocycling on the adaptation and shear bond strength, of composite resin bonded to dentin using etch-and-rinse and self-etch resin adhesives. Confocal microscopy showed both adhesives closely adapted to dentin and a significantly (p<0.001) greater number of resin t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-146

    authors: Freeman R,Varanasi S,Meyers IA,Symons AL

    更新日期:2012-01-01 00:00:00

  • Shear bond strength of tooth-colored indirect restorations bonded to mid-coronal and cervical dentin.

    abstract::To investigate the bonding of tooth-colored indirect restorations to cervical dentin, shear bond strengths of bonded resin inlays to cervical dentin and mid-coronal dentin were investigated and compared. Indirectly fabricated composite inlays (Estenia) were cemented with a dual-cured resin cement (Panavia Fluoro Cemen...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.7

    authors: Shimada Y,Sattabanasuk V,Sadr A,Yuan Y,He Z,Tagami J

    更新日期:2006-03-01 00:00:00

  • Kinetic polymerization behavior of fluorinated monomers for dental use.

    abstract::The kinetic polymerization behavior of 2,2,2-trifluoroethyl methacrylate (TFEMA), 1,1,1,3,3,3-hexafluoroisopropyl methacrylate (HFIPMA), 2,2,2-trifluoroethyl acrylate (TFEA) and 1,1,1,3,3,3-hexafluoroisopropyl acrylate (HFIPA) was determined by isothermal differential scanning calorimetry (DSC) and high-performance li...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-054

    authors: Kadoma Y

    更新日期:2010-10-01 00:00:00

  • Effect of different remaining dentin thickness and long term water storage on dentin bond strength.

    abstract::The purpose of this study was to investigate the effect of remaining dentin thickness (RDT) and long term water storage on dentin bond strength in-vitro. Twenty-seven third molars were randomly divided into 3 groups: Clearfil Bond SE ONE (SE1, Kuraray Noritake Dental, Okayama, Japan), G-Bond plus (GB, GC, Tokyo, Japan...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-140

    authors: Ting S,Chowdhury AFMA,Sun J,Kakuda S,Sidhu SK,Yoshida Y,Selimovic D,Sano H

    更新日期:2018-07-29 00:00:00

  • Permeability of etching agent constituents through dentin.

    abstract::The in vitro dentin permeability of the constituents of two types of conventional phosphoric acid etching agents which had different viscosities, and their pH changes after being permeated dentin were investigated. It was recognized that, even though the etching was for a short time (one minute) followed by rinsing, t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.164

    authors: Ishikawa K,Ito S,Hata Y

    更新日期:1989-12-01 00:00:00

  • Analysis of fracture surface of titanium-porcelain bonding by electron spectroscopy for chemical analysis.

    abstract::Three commercially available porcelains bonded to titanium were evaluated to determine the weakest zone of the titanium-porcelain bonding structures. Tensile bond tests were performed for these specimens (NO, DU, and VI) and for Ni-Cr alloy-porcelain bonding samples that served as controls. The maximum bond strengths ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-263

    authors: Kannari Y,Endo K,Ida Y,Ochi M,Ohno H

    更新日期:2014-01-01 00:00:00

  • The preparation of PLLA/calcium phosphate hybrid composite and its evaluation of biocompatibility.

    abstract::In tissue engineering, biodegradable polymer materials with both high biocompatibility and high strength are very important as scaffolds for long term use. Therefore, in this research, we tried to prepare the three types of poly(L-lactic acid) (PLLA)/calcium phosphate (CP) hybrid composite for a scaffold biomaterial. ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-117

    authors: Hamada Y,Fujitani W,Kawaguchi N,Daito K,Niido T,Uchinaka A,Mori S,Kojima Y,Manabe M,Nishida K,Arita K,Nakano T,Matsuura N

    更新日期:2012-01-01 00:00:00

  • Titanium removable denture based on a one-metal rehabilitation concept.

    abstract::The use of a single metal for all restorations would be necessary because it protects against metal corrosion caused by the contact of different metals. For this "one-metal rehabilitation" concept, non-alloyed commercially pure (CP) titanium should be used for all restorations. Titanium frameworks have been cast and u...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-137

    authors: Ohkubo C,Sato Y,Nishiyama Y,Suzuki Y

    更新日期:2017-09-26 00:00:00

  • Bioactive-glass in periodontal surgery and implant dentistry.

    abstract::Bioactive-glass (B-G) is a material known for its favorable biological response when in contact with surrounding fibro-osseous tissues, due not only to an osteoconductive property, but also to an osteostimulatory capacity, and superior biocompatibility for use in human body. The objectives of this paper are to review ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-233

    authors: Profeta AC,Prucher GM

    更新日期:2015-01-01 00:00:00

  • Effect of new light curing units on microleakage and microhardness of resin sealants.

    abstract::To determine new developed light curing units with shorter curing times effects on microleakage and microhardness values for resin fissure sealants. Resin filled sealant (UltraSeal-XT), resin unfilled sealant (Delton Type-II) and ormocer-based sealant (Admira-Seal) were light cured with a quartz-tungsten-halogen (QTH)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-357

    authors: Bani M,Tirali RE

    更新日期:2016-01-01 00:00:00

  • Pre-treatment of radicular dentin by self-etch primer containing chlorhexidine can improve fiber post bond durability.

    abstract::We evaluated whether the pre-treatment of radicular dentin by ED Primer containing different concentrations of chlorhexidine can improve the bond durability of fiber post to radicular dentin. Experimental ED primers containing different concentrations of chlorhexidine (0%, 0.5% and 1.0%) were prepared. Thirty extracte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-134

    authors: Zhou J,Yang X,Chen L,Liu X,Ma L,Tan J

    更新日期:2013-01-01 00:00:00

  • Effect of storage conditions on mechanical properties of resin composite blanks for CAD/CAM crowns.

    abstract::The objective of this study was to examine the effects of storage conditions on the flexural strengths of resin composite materials for CAD/CAM restorations. Seven commercially available resin composite CAD/CAM blanks were examined. Rectangular specimens (4.0×1.2×4.0 mm) of each material were trimmed from the blanks a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-202

    authors: Hibino Y,Nagasawa Y,Eda Y,Shigeta H,Nakajima H

    更新日期:2020-09-29 00:00:00

  • Calcium-ion incorporation into titanium surfaces accompanied by electrochemical apatite-deposition.

    abstract::The depths of calcium-ion incorporation into a commercially pure titanium and an experimental beta-type titanium alloy were determined using Auger electron spectroscopy. After the electrochemical deposition of apatite, new compositional gradients appeared in the profiles in which the Ca and P concentrations gradually ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.306

    authors: Ban S,Kamiya A,Sonoda T

    更新日期:2002-12-01 00:00:00

  • Influence of a denture strengthener on the deformation of a maxillary complete denture.

    abstract::The present study investigated the influences of a denture strengthener on the deformation of a maxillary complete denture. Three groups of maxillary complete dentures were fabricated (Group 1 without a strengthener; Group 2 with a Co-Cr alloy wire strengthener; Group 3 with an experimental fiberglass strengthener). T...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.507

    authors: Hirajima Y,Takahashi H,Minakuchi S

    更新日期:2009-07-01 00:00:00

  • Effect of three metal priming agents on the bond strength of adhesive resin cement to Ag-Zn-Sn-In alloy and component metals.

    abstract::The aim of this study was to investigate the effect of three metal priming agents on the bond strength of adhesive resin cement to Silver-Zinc-Tin-Indium (Ag-Zn-Sn-In) alloy and pure Ag, Zn, Sn, and In. The specimens were air-abraded with alumina and then primed with one of three metal priming agents: V-Primer, Esteni...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-139

    authors: Imamura N,Kawaguchi T,Shimizu H,Takahashi Y

    更新日期:2018-03-30 00:00:00

  • Determination of molecular species of calcium salts of MDP produced through decalcification of enamel and dentin by MDP-based one-step adhesive.

    abstract::Enamel and dentin particles were added to an experimental 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based one-step adhesive to react for 30 s. After enamel and dentin reactants were analyzed using X-ray diffraction (XRD) and phosphorus-31 nuclear magnetic resonance ((31)P NMR) techniques, curve-fitting analys...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-260

    authors: Yokota Y,Nishiyama N

    更新日期:2015-01-01 00:00:00

  • Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin.

    abstract::The aim of this study was to investigate in how far the way the specimen is fixed to the testing device influences the micro-tensile bond strength of adhesives to dentin. Compared to a flat jig, a notched jig enables the specimen to be aligned easier and more accurately perpendicular to the interface, thereby concentr...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.694

    authors: Poitevin A,De Munck J,Van Landuyt K,Coutinho E,Peumans M,Lambrechts P,Van Meerbeek B

    更新日期:2007-09-01 00:00:00