Effect of three metal priming agents on the bond strength of adhesive resin cement to Ag-Zn-Sn-In alloy and component metals.

Abstract:

:The aim of this study was to investigate the effect of three metal priming agents on the bond strength of adhesive resin cement to Silver-Zinc-Tin-Indium (Ag-Zn-Sn-In) alloy and pure Ag, Zn, Sn, and In. The specimens were air-abraded with alumina and then primed with one of three metal priming agents: V-Primer, Estenia Opaque Primer, or Alloy Primer. The metal disks were bonded with adhesive resin cement (Super-Bond Bulk-mix technique). Shear bond strengths (n=10/group) were determined before and after 50,000 thermocycles for Ag-Zn-Sn-In alloy as well as after 5,000 thermocycles for pure Ag, Zn, Sn and In. For Ag-Zn-Sn-In alloy, the post-thermocycling bond strength of the Alloy Primer group was significantly higher than that of the other primers. It can be concluded that Alloy Primer containing both the vinyl-thione monomer (VBATDT) and hydrophobic phosphate monomer (MDP) is effective for bonding Ag-Zn-Sn-In alloy and pure Ag, Zn and Sn.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Imamura N,Kawaguchi T,Shimizu H,Takahashi Y

doi

10.4012/dmj.2017-139

subject

Has Abstract

pub_date

2018-03-30 00:00:00

pages

301-307

issue

2

eissn

0287-4547

issn

1881-1361

journal_volume

37

pub_type

杂志文章
  • Application of thermography in dentistry--visualization of temperature distribution on oral tissues.

    abstract::The purpose of this study was to devise and propose appropriate conditions for the photographing of thermal images in the oral cavity and to evaluate which thermography techniques can be applied to dentistry by evaluating the differences in temperature among oral tissues. Thermal images of oral cavities of 20 voluntee...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.436

    authors: Komoriyama M,Nomoto R,Tanaka R,Hosoya N,Gomi K,Iino F,Yashima A,Takayama Y,Tsuruta M,Tokiwa H,Kawasaki K,Arai T,Hosoi T,Hirashita A,Hirano S

    更新日期:2003-12-01 00:00:00

  • Assessment of mechanical properties of WaveOne Gold Primary reciprocating instruments.

    abstract::This study aimed to evaluate cyclic fatigue resistance and bending properties and torque/force generation of WaveOne Gold (WOG) Primary in comparison with WaveOne (WO) Primary and Reciproc (RE) R25. A cyclic fatigue test revealed that the WOG Primary took significantly longer time to fracture compared with the WO Prim...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-203

    authors: Fangli T,Maki K,Kimura S,Nishijo M,Tokita D,Ebihara A,Okiji T

    更新日期:2019-06-01 00:00:00

  • Influence of thin carbonate-containing apatite coating with molecular precursor method to zirconia on osteoblast-like cell response.

    abstract::The influence of a thin carbonate-containing hydroxyapatite (CA) coating to tetragonal zirconia polycrystal (TZP) on osteoblastlike cell response was investigated. TZP disks were subjected to blasting and acid etching. Thin CA coatings were deposited by the molecular precursor method (TZP-CA). Initial cell adhesion of...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-122

    authors: Kaneko H,Sasaki H,Honma S,Hayakawa T,Sato M,Yajima Y,Yoshinari M

    更新日期:2014-01-01 00:00:00

  • Antibacterial and pro-osteogenic effects of β-Defensin-2-loaded mesoporous bioglass.

    abstract::The human antimicrobial peptide beta-defensin-2 (hBD2) shows broad antibacterial activity and infrequent bacterial resistance. Here mesoporous bioactive glass (MBG) was loaded with hBD2, forming hBD2-loaded MBG (BD-MBG). The antibacterial and osteogenic effects of BD-MBG were investigated in comparison with MBG and th...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-105

    authors: Ren L,Zhang Z,Deng C,Zhang N,Li D

    更新日期:2020-12-24 00:00:00

  • Effect of adhesive primer developed exclusively for heat-curing resin on adhesive strength between plastic artificial tooth and acrylic denture base resin.

    abstract::Despite progress in the development of denture base resin and artificial tooth materials, dental clinics are still plagued with artificial teeth falling off the denture base--due to poor bond strength--after denture delivery. Against this background, this study sought to examine the effect and durability of an adhesiv...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.75

    authors: Nishigawa G,Maruo Y,Okamoto M,Oki K,Kinuta Y,Minagi S,Irie M,Suzuki K

    更新日期:2006-03-01 00:00:00

  • Evaluation of the amount of residual monomer on UDMA-based resins by FTIR.

    abstract::The purpose of this study was to establish a method using FTIR to evaluate the polymerization characteristics of UDMA-based resins. Three kinds of experimental UDMA-based resins were prepared with various molar fractions. IR spectra of the cured film specimens were measured with FTIR before and after extracting residu...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.18.176

    authors: Nomoto R,Hirasawa T

    更新日期:1999-06-01 00:00:00

  • Determination of molecular species of calcium salts of MDP produced through decalcification of enamel and dentin by MDP-based one-step adhesive.

    abstract::Enamel and dentin particles were added to an experimental 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based one-step adhesive to react for 30 s. After enamel and dentin reactants were analyzed using X-ray diffraction (XRD) and phosphorus-31 nuclear magnetic resonance ((31)P NMR) techniques, curve-fitting analys...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-260

    authors: Yokota Y,Nishiyama N

    更新日期:2015-01-01 00:00:00

  • Improving biocompatibility of zirconia surface by incorporating Ca ions.

    abstract::Though zirconia has been used in dental implant fixtures, the biocompatibility of the zirconia surface is not optimal for the surrounding tissue, and many surface modifications have been attempted. We have developed a novel method for improving the biocompatibility of zirconia by incorporating Ca ions. Elemental analy...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-199

    authors: Sasaki K,Hayashi T,Asakura M,Ando M,Kawai T,Ban S

    更新日期:2015-01-01 00:00:00

  • Effect of aluminoborate whiskers on mechanical properties of polycarboxylate cements.

    abstract::The mechanical properties of polycarboxylate cements containing 20 mass% of four kinds of aluminoborate whiskers with different fiber lengths and diameters were evaluated. Bending strength of the cements increased with increase in fiber length, whereby the strength of the cement with the longest fiber was about two ti...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.561

    authors: Kurata S,Umemoto K

    更新日期:2008-07-01 00:00:00

  • Morphological and chemical analysis of different precipitates on mineral trioxide aggregate immersed in different fluids.

    abstract::The purpose of this study was to analyze the ultrastructures and chemical compositions of precipitates formed on mineral trioxide aggregate (MTA; White ProRoot MTA) immersed in distilled water (DW) or phosphate buffered saline (PBS), based on the attribution that MTA's bioactivity and sealing ability are influenced by...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2009-133

    authors: Han L,Okiji T,Okawa S

    更新日期:2010-10-01 00:00:00

  • Long-term clinical and radiographic evaluation of the effectiveness of direct pulp capping materials: A meta-analysis.

    abstract::The aim of this review is to evaluate the long-term effectiveness of calcium silicate-based cement (CS) and calcium hydroxide (CH) for direct pulp capping (DPC) to human pulp-exposed permanent teeth. An electronic search and manual search were performed on 21 June 2019. Long-term clinical and radiographic evaluations ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-043

    authors: Matsuura T,Ziauddin SM,Kawata-Matsuura VKS,Sugimoto K,Yamada S,Yoshimura A

    更新日期:2020-10-01 00:00:00

  • Shear bond strength of veneering porcelain to porous zirconia.

    abstract::In this study, two types of porous zirconia and dense zirconia were used. The flexural strength of non-layered zirconia specimens and those of the layered zirconia specimens with veneering porcelain were examined. Furthermore, the shear bond strength of veneering porcelain to zirconia was examined. The flexural streng...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-191

    authors: Nakamura T,Sugano T,Usami H,Wakabayashi K,Ohnishi H,Sekino T,Yatani H

    更新日期:2014-01-01 00:00:00

  • Hardness and Young's modulus of transparent dentin associated with aging and carious disease.

    abstract::This study investigated the changes in hardness and Young's modulus of the transparent layer of dentin associated with aging and the carious process. Eighteen extracted human molars with or without coronal caries were used in this study. The normal teeth were divided into two groups by age, and the carious teeth were ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.648

    authors: Zheng L,Nakajima M,Higashi T,Foxton RM,Tagami J

    更新日期:2005-12-01 00:00:00

  • In vitro study of anti-suck-back ability by themselves on new high-speed air turbine handpieces.

    abstract::The anti-suck-back ability of five new high-speed air turbine handpiece models was evaluated in this study. First, suck-back pressure with water displacement within a glass tube was measured. Next, under three different conditions, how many on-off times it takes before fluorescent stains became visible on a piece of g...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-008

    authors: Ozawa T,Nakano M,Arai T

    更新日期:2010-11-01 00:00:00

  • A comparison of the micro-shear bond strength and failure mode of non-enclosed and mold-enclosed luting cements bonded to metal.

    abstract::The objective of the study was to compare 1) the mean micro-shear bond strength and 2) failure mode of cements to metals in nonenclosed and mold-enclosed specimens. Specimens were prepared in mold-enclosed and non-enclosed formats from two RMGIC's and a self-adhesive resin-cement. 3-way ANOVA analysis and Tukey post h...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-065

    authors: Cheetham JJ,Palamara JE,Tyas MJ,Burrow MF

    更新日期:2013-01-01 00:00:00

  • New partition technique for two-chamber pressure casting unit for titanium.

    abstract::Although titanium has been widely used in prosthetic appliances, such as cast removable partial denture frameworks, high quality castings are still difficult to obtain. This study proposes a new partition technique using a metal foil for improving castability of a two-chamber pressure casting unit. The metal foil was ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.307

    authors: Watanabe K,Okawa S,Kanatani M,Nakano S,Miyakawa O,Kobayashi M

    更新日期:2000-09-01 00:00:00

  • Diametral tensile strength of novel fast-setting calcium silicate cement.

    abstract::Novel fast-setting calcium silicate cement with fluoride (CSC) has been developed for potential applications in tooth crown. The aim of this study was to test the diametral tensile strength (DTS) of different CSC compositions in humid condition on day1, 28, and 180. We tested 'bond CSC' with 3.5% fluoride and no radio...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-390

    authors: Ranjkesh B,Isidor F,Dalstra M,Løvschall H

    更新日期:2016-01-01 00:00:00

  • Long-term evaluation of warm-air treatment effect on adaptation of silane-containing universal adhesives to lithium disilicate ceramic.

    abstract::The effect of warm air-blowing on the sealing ability of two one-bottle and one two-bottle silane-containing universal adhesives (UAs) applied to lithium disilicate ceramics (LDS) was evaluated. Tapered cavities prefabricated in LDS blocks (IPS e.max CAD) were treated by the adhesives, air-blown either with normal air...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-057

    authors: Kaykhine P,Tichy A,Abdou A,Hosaka K,Foxton RM,Sumi Y,Nakajima M,Tagami J

    更新日期:2020-10-24 00:00:00

  • A new procedure of the tensile fatigue test for dental materials.

    abstract::A new tensile fatigue test using a stainless steel screw was introduced. A transparent PMMA rod was selected as the test material. A hole was drilled and tapped into the rod; a screw was put into the rod with dental cement or without cementation. Three types of cyclic loads were applied to the test piece; the number o...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.11.141

    authors: Nishimura F,Nakamura H,Watari F,Tanaka I,Takahashi H

    更新日期:1992-12-01 00:00:00

  • Grindability of alpha-case formed on cast titanium.

    abstract::The hardened alpha-case (alpha-case) layer inevitably forms on the surface of titanium castings when prepared by investment casting. Because the hardness of the alpha-case is incomparable to that of the interior structure, the perception exists that the alpha-case is difficult to remove during cutting, grinding and po...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.587

    authors: Koike M,Jacobson D,Chan KS,Okabe T

    更新日期:2009-09-01 00:00:00

  • Shear bond strengths of a single-step bonding system to enamel and dentin.

    abstract::An experimental primer was developed as a single-step bonding system for resin-modified glass ionomer cements (GIC). Efficacy of this primer on adhesion of resin-modified GICs and resin composite to enamel and dentin was evaluated by shear bond test and SEM observation. Good bond strengths to enamel were obtained (> 1...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.16.40

    authors: Nikaido T,Nakajima M,Higashi T,Kanemura N,Pereira PN,Tagami J

    更新日期:1997-06-01 00:00:00

  • Microtensile bond strength of a newly developed resin cement to dentin.

    abstract::The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a newly developed resin cement, ECD-89 (ECD, Tokuyama Dental, Tokyo, Japan) to dentin and to observe the interfacial micromorphology by comparing with two commercial resin cements, Multilink Automix (MA, Ivoclar Vivadent AG, Schaan, Lie...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-122

    authors: Kawano S,Fu J,Saikaew P,Chowdhury AA,Fukuzawa N,Kadowaki Y,Kakuda S,Hoshika S,Nakaoki Y,Ikeda T,Tanaka T,Sano H

    更新日期:2015-01-01 00:00:00

  • A newly designed automatic pH-cycling system to simulate daily pH fluctuations.

    abstract::The aim of this study was to develop and evaluate an automatic pH-cycling system, which was intended for performing time-lapse analyses of dental caries. Two single-section specimens prepared from each of the five extracted human incisors were studied under a condition of 3- or 9-cycles/day for seven weeks. Increase o...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.280

    authors: Matsuda Y,Komatsu H,Murata Y,Tanaka T,Sano H

    更新日期:2006-06-01 00:00:00

  • Efficacy of dentin bonding to cervical defects.

    abstract::The bonding efficacy of sclerotic dentin was determined by measuring the polymerization contraction gap width of a commercial light-activated resin composite in a cervical defect and by measuring the micro-Vicker's hardness at the dentin adhesive surface; morphological characteristics were observed using a scanning el...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.359

    authors: Tani C,Itoh K,Hisamitsu H,Wakumoto S

    更新日期:2001-12-01 00:00:00

  • Effect of polishing on cyclic fatigue strength of CAD/CAM ceramics.

    abstract::The biaxial flexural strength and cyclic fatigue biaxial flexural strength of CAD/CAM ceramics polished with #220, 400, 600 and 1000 diamond pads were measured in an effort to determine the effect of surface roughness on fatigue behavior of dental ceramics. The surface roughness was improved after polishing with a sma...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.18.395

    authors: Nakazato T,Takahashi H,Yamamoto M,Nishimura F,Kurosaki N

    更新日期:1999-12-01 00:00:00

  • Novel self-etching and antibacterial orthodontic adhesive containing dimethylaminohexadecyl methacrylate to inhibit enamel demineralization.

    abstract::Enamel demineralization is one of the most undesired side effects of fixed orthodontic treatment, which will lead to white spot lesions (WSLs) on tooth surfaces. The development of WSLs is due to prolonged accumulation of bacterial plaque and associated acid production. Self-etching adhesives have been used in orthodo...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-286

    authors: Wang X,Zhang N,Wang B,Park SR,Weir MD,Xu HHK,Bai Y

    更新日期:2018-07-29 00:00:00

  • Soda-lime glass as a binder in reusable experimental investment for dental castings.

    abstract::In this study, different glasses were investigated to improve reusable investments. Borosilicate glass (BSG) powder and soda-lime glass (SLG) powder were prepared by milling broken beakers and microscope slides, respectively, and used in experimental investments (I-BSG, I-SLG) by blending glass powder (10 wt%) with cr...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-040

    authors: Yagi S,Zhang Z,Aida Y,Hotta Y,Tamaki Y,Miyazaki T

    更新日期:2011-01-01 00:00:00

  • Bilinear elastic property of the periodontal ligament for simulation using a finite element mandible model.

    abstract::This study aimed to introduce a procedure for determining the bilinear elastic moduli (E1 and E2) of the periodontal ligament for a mathematical tooth model to analyse stress in the mandible. The bone and tooth morphology were scanned from a dry skull and an extracted intact tooth, respectively, and reconstructed in a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-170

    authors: Borák L,Florian Z,Bartáková S,Prachár P,Murakami N,Ona M,Igarashi Y,Wakabayashi N

    更新日期:2011-01-01 00:00:00

  • Anisotropy of tensile strengths of bovine dentin regarding dentinal tubule orientation and location.

    abstract::The purpose of this study was to investigate the effects of the location and orientation of dentinal tubules in the tooth on tensile strengths of the dentin. Dumbbell-shaped specimens of 12 groups from various locations and dentinal tubule orientations were prepared. The tensile test was performed in distilled water a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.32

    authors: Inoue T,Takahashi H,Nishimura F

    更新日期:2002-03-01 00:00:00

  • Bond strength of artificial teeth to thermoplastic denture base resin for injection molding.

    abstract::This research was conducted to investigate the bond strength between artificial teeth and a thermoplastic denture base resin for injection molding with different surface preparations for use in flexible resin removable partial dentures. Composite resin denture teeth and acrylic denture resin teeth were bonded to three...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-183

    authors: Tashiro S,Kawaguchi T,Hamanaka I,Takahashi Y

    更新日期:2021-01-15 00:00:00