Hardness and Young's modulus of transparent dentin associated with aging and carious disease.

Abstract:

:This study investigated the changes in hardness and Young's modulus of the transparent layer of dentin associated with aging and the carious process. Eighteen extracted human molars with or without coronal caries were used in this study. The normal teeth were divided into two groups by age, and the carious teeth were divided into two groups of active or arrested caries. After polishing the specimens parallel to the long axis of the tooth, both hardness and Young's modulus were measured using a nanoindentation tester. The hardness and Young's modulus of the transparent layer in aged dentin were higher than the other portions of aged dentin. The transparent layer under carious lesions had a significantly lower hardness than the underlying normal dentin, whereas its Young's modulus was not significantly reduced. The hardness and Young's modulus of the transparent layer in active carious lesions were lower than those in arrested carious lesions.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Zheng L,Nakajima M,Higashi T,Foxton RM,Tagami J

doi

10.4012/dmj.24.648

keywords:

subject

Has Abstract

pub_date

2005-12-01 00:00:00

pages

648-53

issue

4

eissn

0287-4547

issn

1881-1361

journal_volume

24

pub_type

杂志文章
  • Measurement of exothermic heat released during polymerization of a lightcuring composite resin: Comparison of light irradiation modes.

    abstract::High-power light-curing units have emerged that reduce the time of procedures in dental clinical work. However, patients sometimes complain of pain during the polymerization of composite resin. In this experiment, we investigated how differences in light-curing mode affect the temperature rise during composite resin p...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-158

    authors: Hori M,Fujimoto K,Asakura M,Nagase Y,Mieki A,Kawai T

    更新日期:2019-07-31 00:00:00

  • Effects of dental porcelain containing silver nanoparticles on static fatigue.

    abstract::The purpose of this study was to clarify the effect of silver nanoparticles on the behavior of subcritical crack growth (SCG) in dental porcelains. Prior to occurrence of fast fracture in dental porcelains, SCG occurs and leads to strength degradation over time. SCG in dental porcelains can be characterized by the str...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-266

    authors: Fujieda T,Uno M,Ishigami H,Kurachi M,Kamemizu H,Wakamatsu N,Doi Y

    更新日期:2013-01-01 00:00:00

  • Effect of commercially available bonding agents impregnated with fibers on bending strength of hybrid resin.

    abstract::To clarify the mechanical properties of fiber-reinforced hybrid resin bridges, this study evaluated the influence of various bonding agents ((Modeling Liquid (ML), DE Resin (DE), Bell Bond (BE), Mega Bond (MG), Durafil Bond (DU), Fluoro Bond (FB), Mac-Bond (MC), EG Bond (EG), Unifill Bond (UN), Single Bond (SN)) impre...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.723

    authors: Tsushima S,Gomi H,Shinya A,Yokoyama D,Vallittu PK,Shinya A

    更新日期:2008-09-01 00:00:00

  • Effect of aluminoborate whiskers on mechanical properties of polycarboxylate cements.

    abstract::The mechanical properties of polycarboxylate cements containing 20 mass% of four kinds of aluminoborate whiskers with different fiber lengths and diameters were evaluated. Bending strength of the cements increased with increase in fiber length, whereby the strength of the cement with the longest fiber was about two ti...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.561

    authors: Kurata S,Umemoto K

    更新日期:2008-07-01 00:00:00

  • Machining accuracy of crowns by CAD/CAM system using TCP/IP: influence of restorative material and scanning condition.

    abstract::The purpose of this study was to determine the optimal condition for fabricating accurate crowns efficiently using an internet-based CAD/CAM system. The influences of three different CAD/CAM restorative materials (titanium, porcelain, and composite resin) and three different step-over scanning distances (0.01 mm, 0.11...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.549

    authors: Tomita S,Shin-ya A,Gomi H,Shin-ya A,Yokoyama D

    更新日期:2007-07-01 00:00:00

  • Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor.

    abstract::The purpose of this study was to evaluate the effect of various incremental filling techniques on adhesion between composite and cavity floor using light-cured resin composite. Black ABS resin and hybrid resin composite were used as mold materials--instead of dentin--for the preparation of cavities, and standardized t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.503

    authors: Chikawa H,Inai N,Cho E,Kishikawa R,Otsuki M,Foxton RM,Tagami J

    更新日期:2006-09-01 00:00:00

  • Cytotoxicity evaluation of luting resin cements on bovine dental pulp-derived cells (bDPCs) by real-time cell analysis.

    abstract::To evaluate the cytotoxicity of resin cements on dental pulp-derived cells (bDPCs), Bifix QM (BQM), Choice 2(C2), RelyX U200(RU200), Maxcem Elite(ME), and Multilink Automix(MA) were tested. The materials were incubated in DMEM for 72 h. A real-time cell analyzer was used to evaluate cell survival. The statistical anal...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-167

    authors: Arslan Malkoç M,Demir N,Şengün A,Bozkurt ŞB,Hakki SS

    更新日期:2015-01-01 00:00:00

  • The hydration chemistry of ProRoot MTA.

    abstract::'Tooth-coloured' ProRoot MTA is an endodontic cement comprising an 80:20 wt% mixture of white Portland cement (WPC) and bismuth oxide. The setting reactions within this cement system are not currently well understood. Accordingly, this research monitors the early hydration chemistry of ProRoot MTA by X-ray diffraction...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-309

    authors: Li Q,Coleman NJ

    更新日期:2015-01-01 00:00:00

  • Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials.

    abstract::The purpose of this study was to evaluate the effect of different polymerization cycles on the flexural strengths and microhardness of two denture base materials (Meliodent and Paladent). Heat-polymerized acrylic resin specimens (65.0 mm long×10.0 mm wide×2.5 mm in height) were prepared using different short and long ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-023

    authors: Gungor H,Gundogdu M,Alkurt M,Yesil Duymus Z

    更新日期:2017-03-31 00:00:00

  • Influence of resin coating on bond strength of self-adhesive resin cements to dentin.

    abstract::This study evaluated the effect of resin coating (COA) on dentin bond strength (BS) of five resin cements (RC). Ten groups were tested, according to RC and COA combinations. RCs were applied onto prepolymerized resin discs, which were bonded to dentin surfaces. Teeth were stored in water for 24 h, subjected to 5,000 t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-099

    authors: Giannini M,Takagaki T,Bacelar-Sá R,Vermelho PM,Ambrosano GM,Sadr A,Nikaido T,Tagami J

    更新日期:2015-01-01 00:00:00

  • Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns.

    abstract::Thermal misfit is deemed as one reason for the chipping of veneered zirconia restorations. Aim of the present study was to assess the effect of thermal misfit on the fracture load of veneered zirconia frameworks and to evaluate the applicability of a universal veneering ceramic for both zirconia and titanium framework...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.766

    authors: Fischer J,Stawarczyk B,Tomic M,Strub JR,Hämmerle CH

    更新日期:2007-11-01 00:00:00

  • Simulation of transient thermal stress in gypsum-bonded investment.

    abstract::The aim of this study was to clarify the effect of heating rate on the development of both transient and residual stresses in investment molds. Solid, cylindrical, gypsum-based molds were modeled and theoretical calculations made of temperature distributions with a constant heating rate. These calculations used experi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.15.121

    authors: Asaoka K,Tesk JA

    更新日期:1996-12-01 00:00:00

  • Influence of resin coating materials on Porphyromonas gingivalis attachment.

    abstract::Resin coating materials have been used for composite resin or provisional restoration in order to prevent plaque accumulation on their surfaces. However, it is not clear whether the coating materials influence attachment of periodontal bacteria. Therefore, we investigated the effect of resin coating materials on the a...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2011-164

    authors: Kumada A,Matsuka Y,Mine A,Ono M,Uehara J,Sonoi N,Ito T,Takashiba S,Kuboki T

    更新日期:2012-02-03 00:00:00

  • Corrosion behavior of dental alloys coupled with titanium. Part 2. The area ratio dependence in five solutions.

    abstract::Sixteen alloys and five pure metals were used and the open circuit potentials (OCP) and the coupled potentials with titanium were measured in five kinds of solutions. All alloys and metals showed the maximum OCP in 1.3% lactic acid solution, and the minimum in 0.01% sodium sulfide solution. The coupled potential depen...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.75

    authors: Nakayama M,Ando N

    更新日期:2001-03-01 00:00:00

  • A comparison of the micro-shear bond strength and failure mode of non-enclosed and mold-enclosed luting cements bonded to metal.

    abstract::The objective of the study was to compare 1) the mean micro-shear bond strength and 2) failure mode of cements to metals in nonenclosed and mold-enclosed specimens. Specimens were prepared in mold-enclosed and non-enclosed formats from two RMGIC's and a self-adhesive resin-cement. 3-way ANOVA analysis and Tukey post h...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-065

    authors: Cheetham JJ,Palamara JE,Tyas MJ,Burrow MF

    更新日期:2013-01-01 00:00:00

  • Effect of air abrasion and thermocycling on resin adaptation and shear bond strength to dentin for an etch-and-rinse and self-etch resin adhesive.

    abstract::This study examined the effect of air abrasion and thermocycling on the adaptation and shear bond strength, of composite resin bonded to dentin using etch-and-rinse and self-etch resin adhesives. Confocal microscopy showed both adhesives closely adapted to dentin and a significantly (p<0.001) greater number of resin t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-146

    authors: Freeman R,Varanasi S,Meyers IA,Symons AL

    更新日期:2012-01-01 00:00:00

  • Effect of monomer structure on the mechanical properties of light-cured composite resins.

    abstract::The effects of monomer structure on the mechanical properties of visible light-cured composite resins based on the seven types of aromatic dimethacrylates were investigated. The results of this study suggested that the mechanical properties of the composite resins were dependent upon the chemical structure of the dime...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.40

    authors: Kawaguchi M,Fukushima T,Horibe T

    更新日期:1989-06-01 00:00:00

  • Effect of surface preparation on the bond strength of heat-polymerized denture base resin to commercially pure titanium and cobalt-chromium alloy.

    abstract::The aim of this study was to investigate the bond durability of heat-polymerized denture base resin to cast CP Ti and Co-Cr alloy. The alloy specimens were divided into five groups: 1) airborne-particle abraded with 50 µm alumina (SAND), 2) Rocatec tribochemical silica coating system (RO), 3) air-abraded followed by a...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2010-089

    authors: Kawaguchi T,Shimizu H,Lassila LV,Vallittu PK,Takahashi Y

    更新日期:2011-01-01 00:00:00

  • Cavity adaptation of resin composite in canine cavity in vivo.

    abstract::The efficacy of four commercial and two experimental dentin bonding systems was examined by observing the cavity adaptation of commercial light-cured resin composites restored in the dogs scheduled to be sacrificed after a medical experiment. Before being sacrificed, a cylindrical class V cavity was prepared in each c...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.195

    authors: Tani C,Itoh K,Ohba M,Tada K,Manabe A,Hisamitsu H,Wakumoto S

    更新日期:1998-09-01 00:00:00

  • Influence of different elastic moduli of dowel and core on stress distribution in root.

    abstract::This study was carried out to investigate the influences of elastic moduli of the dowel-core combination on the stress distribution in the root by the use of 2-dimensional finite element analysis. The peak stress at the dowel-cement interface was influenced strongly by a change of elastic modulus of the post (from 20,...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.50

    authors: Ukon S,Moroi H,Okimoto K,Fujita M,Ishikawa M,Terada Y,Satoh H

    更新日期:2000-03-01 00:00:00

  • Micro computed tomography evaluation of the Self-adjusting file and ProTaper Universal system on curved mandibular molars.

    abstract::The aim of this investigation was to compare the cleaning and shaping efficiency of Self-adjusting file and Protaper, and to assess the correlation between root canal curvature and working time in mandibular molars using micro-computed tomography. Twenty extracted mandibular molars instrumented with Protaper and Self-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-255

    authors: Serefoglu B,Piskin B

    更新日期:2017-09-26 00:00:00

  • Analysis of fracture surface of titanium-porcelain bonding by electron spectroscopy for chemical analysis.

    abstract::Three commercially available porcelains bonded to titanium were evaluated to determine the weakest zone of the titanium-porcelain bonding structures. Tensile bond tests were performed for these specimens (NO, DU, and VI) and for Ni-Cr alloy-porcelain bonding samples that served as controls. The maximum bond strengths ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-263

    authors: Kannari Y,Endo K,Ida Y,Ochi M,Ohno H

    更新日期:2014-01-01 00:00:00

  • Microstructure and homogeneity of dental porcelain frits.

    abstract::The microstructure and homogeneity of three commercial dentin and incisal unfired porcelain frits (one conventional and two ultra-low fusing types, fused-to metal were analyzed by X-ray diffractometry, scanning electron microspectroscopy, and wavelength- and energy dispersive X-ray microspectroscopy. The average conte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.264

    authors: Ban S,Matsuo K,Mizutani N,Iwase H,Kani T,Hasegawa J

    更新日期:1998-12-01 00:00:00

  • Diametral tensile strength of novel fast-setting calcium silicate cement.

    abstract::Novel fast-setting calcium silicate cement with fluoride (CSC) has been developed for potential applications in tooth crown. The aim of this study was to test the diametral tensile strength (DTS) of different CSC compositions in humid condition on day1, 28, and 180. We tested 'bond CSC' with 3.5% fluoride and no radio...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-390

    authors: Ranjkesh B,Isidor F,Dalstra M,Løvschall H

    更新日期:2016-01-01 00:00:00

  • Bond strength and microleakage of self-adhesive and conventional fissure sealants.

    abstract::The aim of this study was to compare the shear bond strengths (SBS), failure modes (adhesive, cohesive, or mixed), and marginal microleakage occurrence of conventional resin (CR)-based, glass ionomer (GI)-based, and self-adhesive resin (SAR)-based fissure sealants with or without prior phosphoric acid (PA) etching. Fi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-227

    authors: Simsek Derelioglu S,Yilmaz Y,Celik P,Carikcioglu B,Keles S

    更新日期:2014-01-01 00:00:00

  • Effect of etching with low concentration hydrofluoric acid on the bond strength of CAD/CAM resin block.

    abstract::The effect of etching for 90 s with low concentrations (0.5, 1.0, 2.0, 3.0, 3.5, and 4.0%) of hydrofluoric acid (HF) on the adhesiveness of computer-aided design/computer-aided manufacturing (CAD/CAM) resin blocks [CERASMART (CS), SHOFU BLOCK HC (HC), KATANA AVENCIA Block(KA), and VITA ENAMIC (EN)] was investigated. E...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-398

    authors: Niizuma Y,Kobayashi M,Toyama T,Manabe A

    更新日期:2020-12-03 00:00:00

  • Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys.

    abstract::The effects of dissolved-oxygen concentration and fluoride concentration on the corrosion behaviors of commercial pure titanium, Ti-6Al-4V and Ti-6Al-7Nb alloys and experimentally produced Ti-0.2Pd and Ti-0.5Pt alloys were examined using the corrosion potential measurements. The amount of dissolved Ti was analyzed by ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.83

    authors: Nakagawa M,Matsuya S,Udoh K

    更新日期:2002-06-01 00:00:00

  • Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions.

    abstract::This study compared differences in discoloration and dissolution in several titanium alloys with immersion in peroxide- or fluoride-containing solution. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-0.15Pd, Ti-6Al-4V, Ti-7Nb-6Al, Ti-55Ni, Ti-10Cu, and Ti-20Cr. Two test solutions were p...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.117

    authors: Noguchi T,Takemoto S,Hattori M,Yoshinari M,Kawada E,Oda Y

    更新日期:2008-01-01 00:00:00

  • Bactericidal efficacy of glycine-type amphoteric surfactant as a denture cleaner and its influence on properties of denture base resins.

    abstract::The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.307

    authors: Hashiguchi M,Nishi Y,Kanie T,Ban S,Nagaoka E

    更新日期:2009-05-01 00:00:00

  • Fabrication of all-ceramic crowns by a new method.

    abstract::A new method of all-ceramic production using alumina coping has been developed. The present study investigates the influence of secondary firing (glass infiltration firing) conditions. Samples of porcelain build-up without secondary firing were also assessed. The suitability of coping that included secondary firing wa...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-275

    authors: Masuda T,Kakimoto K,Takahashi K,Komasa Y

    更新日期:2016-01-01 00:00:00