Measurement of exothermic heat released during polymerization of a lightcuring composite resin: Comparison of light irradiation modes.

Abstract:

:High-power light-curing units have emerged that reduce the time of procedures in dental clinical work. However, patients sometimes complain of pain during the polymerization of composite resin. In this experiment, we investigated how differences in light-curing mode affect the temperature rise during composite resin polymerization in vitro. Light-curing mode conditions were divided into four groups: 3 s in plasma mode (Plm3) and 5, 10, and 20 s in standard mode. The temperature curve under Plm3 exhibited a rapid increase during the first 3 s of light curing before reaching a maximum of around 55°C. In contrast, the temperature rose rapidly but less sharply for irradiation in each standard mode compared with Plm3. These results suggest that irradiation using a high-power mode increases the temperature at an excessively high rate, and this may raise concern about side effects on the pulp.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Hori M,Fujimoto K,Asakura M,Nagase Y,Mieki A,Kawai T

doi

10.4012/dmj.2018-158

subject

Has Abstract

pub_date

2019-07-31 00:00:00

pages

646-653

issue

4

eissn

0287-4547

issn

1881-1361

journal_volume

38

pub_type

杂志文章
  • A study of in vivo degradation of two vital home bleaching gels.

    abstract::This study investigated hydrogen peroxide (H2O2) concentration of two home bleaching gels, in their dispensing syringes and their degradation in vivo in intraoral bleaching trays. Two bleaching gels were studied, 7.5% hydrogen peroxide (HP) and 20% carbamide peroxide (CP). The concentration of H2O2 was determined in d...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-317

    authors: Alonso De La Peña V,Rodriguez Carreira A,Corral Aneiros R,López Ratón M,Guitián Rivera F

    更新日期:2013-01-01 00:00:00

  • Machining accuracy of crowns by CAD/CAM system using TCP/IP: influence of restorative material and scanning condition.

    abstract::The purpose of this study was to determine the optimal condition for fabricating accurate crowns efficiently using an internet-based CAD/CAM system. The influences of three different CAD/CAM restorative materials (titanium, porcelain, and composite resin) and three different step-over scanning distances (0.01 mm, 0.11...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.549

    authors: Tomita S,Shin-ya A,Gomi H,Shin-ya A,Yokoyama D

    更新日期:2007-07-01 00:00:00

  • Changes on NiTi orthodontic wired due to acidic fluoride solution.

    abstract::The effect of acidic fluoride solution on NiTi arch wires was examined by testing crystal structure, tensile strength, morphology after fracture, and element release from wire under four different test solutions after 1 or 3 d immersion. Three-day immersion in a 0.2%/pH 4 solution did not form any new crystal structur...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.557

    authors: Kwon YH,Cheon YD,Seol HJ,Lee JH,Kim HI

    更新日期:2004-12-01 00:00:00

  • Evaluation of an articulated measuring apparatus for use in the oral cavity.

    abstract::The aim of this study was to evaluate the trial Teaching Robot for the development of a contact-type measuring apparatus for using directly in the oral cavity. A standard model was used to mimic the dentition by placing an arrangement of three bearing balls. The diameters of the balls were measured. A practical dentit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.168

    authors: Maikuma Y,Usui K,Araki K,Mataki S,Kurosaki N,Furuya N

    更新日期:2003-06-01 00:00:00

  • Possible segregation caused by centrifugal titanium casting.

    abstract::The possibility of the segregation under solidification process using a centrifugal casting machine was investigated using an electron probe microanalyzer with elemental distribution map, line analysis and quantitative analysis. When a very small quantity of platinum was added to local molten titanium during the casti...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.15.212

    authors: Watanabe K,Okawa S,Kanatani M,Nakano S,Miyakawa O,Kobayashi M

    更新日期:1996-12-01 00:00:00

  • Characterization of 50wt%SiO2-20wt%P2O5-30wt%CaO glass-ceramic powders prepared by the sol-gel process.

    abstract::Glass-ceramic powders with the oxide batch formulation 50wt%SiO2, 20wt%P2O5 and 30wt%CaO were prepared by the sol-gel process using tetraethoxysilane, calcium nitrate and phosphoric acid as raw materials. The obtained gels and powders were characterized by TG-DTA thermal analysis, FTIR analyses and XRD measurements. T...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.16.117

    authors: Taira M,Okazaki M,Takahashi J

    更新日期:1997-12-01 00:00:00

  • Microhardness evaluation of resin composites polymerized by three different light sources.

    abstract::This study examined the surface microhardness of four kinds of resin composites with different fillers and resin matrices. Ten specimens of 2 mm thickness and 4 mm diameter of each resin composite were polymerized using a halogen light, a blue light-emitted diode, and a plasma arc unit. Microhardness evaluation was pe...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:

    authors: Hubbezoğlu I,Bolayir G,Doğan OM,Doğan A,Ozer A,Bek B

    更新日期:2007-11-01 00:00:00

  • SEM observation of collagen fibrils secreted from the body surface of osteoblasts on a CO3apatite-collagen sponge.

    abstract::The secretion of collagen by osteoblasts was observed by scanning electron microscopy (SEM). Osteoblast-like cells were cultured on a CO3apatite-collagen sponge reinforced with a porous HAp frame. After three days' incubation, a number of newly created matrix fibrils, forming a network structure, were observed at the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.460

    authors: Hirata I,Nomura Y,Tabata H,Miake Y,Yanagisawa T,Okazaki M

    更新日期:2005-09-01 00:00:00

  • Titanium removable denture based on a one-metal rehabilitation concept.

    abstract::The use of a single metal for all restorations would be necessary because it protects against metal corrosion caused by the contact of different metals. For this "one-metal rehabilitation" concept, non-alloyed commercially pure (CP) titanium should be used for all restorations. Titanium frameworks have been cast and u...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-137

    authors: Ohkubo C,Sato Y,Nishiyama Y,Suzuki Y

    更新日期:2017-09-26 00:00:00

  • Effect of experimental acid/base conditioner on microtensile bond strength of 4-META/MMA-TBB resin to dentin after long-term water immersion.

    abstract::An experimental conditioner (Exp), which was an aqueous solution of 10% ascorbic acid and 5% ferric chloride, was prepared in this study. This study evaluated the effect of Exp on the microtensile bond strength between a self-curing resin and dentin after long-term water immersion. Flat human dentin surfaces were sequ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-078

    authors: Soeno K,Taira Y,Ito S

    更新日期:2012-01-01 00:00:00

  • Influences of filler content and size on the color adjustment potential of nonlayered resin composites.

    abstract::The blending effect (BE) plays an important role in esthetics of the composite resin. The objective of this study was to determine the extents to which filler size and content affect the BE. Three types of fillers (0.7, 1.0, and 1.5 µm) were mixed at weight contents of 60, 70, 75, and 80%. This study simulated clinica...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-083

    authors: Suh YR,Ahn JS,Ju SW,Kim KM

    更新日期:2017-01-31 00:00:00

  • Swelling/deswelling mechanism of calcium alginate gel in aqueous solutions.

    abstract::To elucidate the mechanism of dimensional changes in alginate impression in solutions, the relationship between the ion concentrations in three types of solutions (nonelectrolyte and monovalent and divalent metallic salts) and change in gel volume was examined. The gel in the monovalent metallic salt solution expanded...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.396

    authors: Saitoh S,Araki Y,Kon R,Katsura H,Taira M

    更新日期:2000-12-01 00:00:00

  • Cytotoxicity evaluation of luting resin cements on bovine dental pulp-derived cells (bDPCs) by real-time cell analysis.

    abstract::To evaluate the cytotoxicity of resin cements on dental pulp-derived cells (bDPCs), Bifix QM (BQM), Choice 2(C2), RelyX U200(RU200), Maxcem Elite(ME), and Multilink Automix(MA) were tested. The materials were incubated in DMEM for 72 h. A real-time cell analyzer was used to evaluate cell survival. The statistical anal...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-167

    authors: Arslan Malkoç M,Demir N,Şengün A,Bozkurt ŞB,Hakki SS

    更新日期:2015-01-01 00:00:00

  • Corrosion behavior of dental alloys coupled with titanium. Part 2. The area ratio dependence in five solutions.

    abstract::Sixteen alloys and five pure metals were used and the open circuit potentials (OCP) and the coupled potentials with titanium were measured in five kinds of solutions. All alloys and metals showed the maximum OCP in 1.3% lactic acid solution, and the minimum in 0.01% sodium sulfide solution. The coupled potential depen...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.75

    authors: Nakayama M,Ando N

    更新日期:2001-03-01 00:00:00

  • Evaluation of the amount of residual monomer on UDMA-based resins by FTIR.

    abstract::The purpose of this study was to establish a method using FTIR to evaluate the polymerization characteristics of UDMA-based resins. Three kinds of experimental UDMA-based resins were prepared with various molar fractions. IR spectra of the cured film specimens were measured with FTIR before and after extracting residu...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.18.176

    authors: Nomoto R,Hirasawa T

    更新日期:1999-06-01 00:00:00

  • Long-term clinical and radiographic evaluation of the effectiveness of direct pulp capping materials: A meta-analysis.

    abstract::The aim of this review is to evaluate the long-term effectiveness of calcium silicate-based cement (CS) and calcium hydroxide (CH) for direct pulp capping (DPC) to human pulp-exposed permanent teeth. An electronic search and manual search were performed on 21 June 2019. Long-term clinical and radiographic evaluations ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-043

    authors: Matsuura T,Ziauddin SM,Kawata-Matsuura VKS,Sugimoto K,Yamada S,Yoshimura A

    更新日期:2020-10-01 00:00:00

  • Effects of light sources and visible light-activated titanium dioxide photocatalyst on bleaching.

    abstract::The objective of this study was to evaluate, using methylene blue (MB), the effects of various light sources on the bleaching action of hydrogen peroxide (H(2)O(2)) with two titanium dioxide (TiO(2)) photocatalysts - an ultraviolet light-activated TiO(2) photocatalyst (UVTiO(2)) versus a visible light-activated TiO(2)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.693

    authors: Suyama Y,Otsuki M,Ogisu S,Kishikawa R,Tagami J,Ikeda M,Kurata H,Cho T

    更新日期:2009-11-01 00:00:00

  • A biocompatible model for evaluation of the responses of rat periapical tissue to a new zinc oxide-eugenol sealer.

    abstract::We aimed to establish an experimental animal model to evaluate materials for endodontic therapy. We focused on the biocompatibility of new paste-type zinc oxide-eugenol (ZOE) sealer. The results of this sealer were compared with those of conventional powder/liquid ZOE and eugenol-free sealers. The molars of Wistar rat...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-095

    authors: Mutoh N,Tani-Ishii N

    更新日期:2011-01-01 00:00:00

  • The extent of polymerization of Class II light-cured composite resin restorations; effects of incremental placement technique, exposure time and heating for resin inlays.

    abstract::The extent of polymerization of light-cured composite resins cured in relatively large class II cavities was estimated by measuring Knoop hardness on sectioned surfaces of resin restorations. The influences of the incremental placement technique, exposure time, and post-curing of resin inlay on the extent of polymeriz...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.159

    authors: Hirabayashi S,Hood JA,Hirasawa T

    更新日期:1993-12-01 00:00:00

  • Effects of polishing on surface roughness and hardness of glass-fiber-reinforced polypropylene.

    abstract::Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-012

    authors: Tanimoto Y,Nagakura M

    更新日期:2018-11-30 00:00:00

  • Effect of doxycycline-treated hydroxyapatite surface on bone apposition: A histomophometric study in murine maxillae.

    abstract::Improved osseointegration of dental implants is imperative in clinic. Effect of doxycycline on promoting bone formation after implant placement was expected due to its inhibitory properties on inflammation and osteoclastogenesis. To evaluate new bone formation on the hydroxyapatite (HA)-coated implant surface, which w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-007

    authors: Ding L,Zhang P,Wang X,Hao J,Aoki K,Kuroda S,Kasugai S

    更新日期:2018-01-30 00:00:00

  • Spectroscopic characterization of enamel surfaces irradiated with Er:YAG laser.

    abstract::The purpose of this study was to investigate the effect of laser irradiation on the enamel surface spectroscopically. Polished bovine enamel surface was irradiated with an Er:YAG laser apparatus and chemically analyzed using X-ray photoelectron spectroscopy (XPS). XPS detected core electron peaks such as carbon (C 1s)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.214

    authors: Mine A,Yoshida Y,Suzuki K,Nakayama Y,Yatani H,Kuboki T

    更新日期:2006-06-01 00:00:00

  • Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.

    abstract::The corrosion behavior of three Ni-Ti alloys with compositions as commercial super-elastic orthodontic wires was investigated using polished plate specimens. Corrosion resistance was estimated by potentiodynamic polarization measurement in 0.9% NaCl and 1% lactic acid solutions and analysis of released metals by atomi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.31

    authors: Iijima M,Endo K,Ohno H,Mizoguchi I

    更新日期:1998-03-01 00:00:00

  • Determination of molecular species of calcium salts of MDP produced through decalcification of enamel and dentin by MDP-based one-step adhesive.

    abstract::Enamel and dentin particles were added to an experimental 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based one-step adhesive to react for 30 s. After enamel and dentin reactants were analyzed using X-ray diffraction (XRD) and phosphorus-31 nuclear magnetic resonance ((31)P NMR) techniques, curve-fitting analys...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-260

    authors: Yokota Y,Nishiyama N

    更新日期:2015-01-01 00:00:00

  • Zirconia ceramics, their contrast ratio and grain size depending on sintering parameters.

    abstract::This study investigated the contrast ratio and grain size depending on sintering parameters of twelve different zirconia materials and compared with glass-ceramic (N=156, n=12 per group). Contrast ratio of all ceramics was measured using a spectrophotometer according to ISO 2471: 2008. Grain sizes of zirconia were det...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-056

    authors: Stawarczyk B,Emslander A,Roos M,Sener B,Noack F,Keul C

    更新日期:2014-01-01 00:00:00

  • Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns.

    abstract::Thermal misfit is deemed as one reason for the chipping of veneered zirconia restorations. Aim of the present study was to assess the effect of thermal misfit on the fracture load of veneered zirconia frameworks and to evaluate the applicability of a universal veneering ceramic for both zirconia and titanium framework...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.766

    authors: Fischer J,Stawarczyk B,Tomic M,Strub JR,Hämmerle CH

    更新日期:2007-11-01 00:00:00

  • In vitro pH analysis of active and arrested dentinal caries in extracted human teeth using a micro pH sensor.

    abstract::The aim of this study was to evaluate the pH at the surface of active or arrested carious dentin using a micro pH sensor, and to compare the relationship between different pH measurement techniques. Twenty extracted carious teeth were divided into two groups, active or arrested caries, according to predefined clinical...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.423

    authors: Murakami K,Kitasako Y,Burrow MF,Tagami J

    更新日期:2006-09-01 00:00:00

  • Abutment screw loosening of endosseous dental implant body/abutment joint by cyclic torsional loading test at the initial stage.

    abstract::Cyclic torsional loading tests were carried out in the laboratory using various implant systems, in order to clarify differences between the systems in loosening of abutment screws. Six samples from six commercially available abutment systems were used, giving a total of 36 samples. Four of the systems used internal c...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-023

    authors: Katsuta Y,Watanabe F

    更新日期:2015-01-01 00:00:00

  • Effects of incorporation of nano-fluorapatite particles on microhardness, fluoride releasing properties, and biocompatibility of a conventional glass ionomer cement (GIC).

    abstract::Present study evaluated effects of addition of Nanoparticles fluorapatite (Nano-FA) on microhardness and fluoride release of a Glass Ionomer Cement (GIC, Fuji IX GP Fast). Forty-eight specimens prepared, divided equally into 4 groups (2 with Nano-FA); after 24 h and one week Vickers microhardness (HV) was measured. Na...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-437

    authors: Moshaverinia M,Borzabadi-Farahani A,Sameni A,Moshaverinia A,Ansari S

    更新日期:2016-01-01 00:00:00

  • Influence of different elastic moduli of dowel and core on stress distribution in root.

    abstract::This study was carried out to investigate the influences of elastic moduli of the dowel-core combination on the stress distribution in the root by the use of 2-dimensional finite element analysis. The peak stress at the dowel-cement interface was influenced strongly by a change of elastic modulus of the post (from 20,...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.50

    authors: Ukon S,Moroi H,Okimoto K,Fujita M,Ishikawa M,Terada Y,Satoh H

    更新日期:2000-03-01 00:00:00