A study of in vivo degradation of two vital home bleaching gels.

Abstract:

:This study investigated hydrogen peroxide (H2O2) concentration of two home bleaching gels, in their dispensing syringes and their degradation in vivo in intraoral bleaching trays. Two bleaching gels were studied, 7.5% hydrogen peroxide (HP) and 20% carbamide peroxide (CP). The concentration of H2O2 was determined in dispensing syringes. Twenty individuals were involved in this study. The gels were placed in trays of both arches and their degradation determined at 5, 10, 15, 20, 30, 40, 60 and 75 min. The concentrations of H2O2 in syringes were (HP) 8.12% and (CP) 7.95%. For the HP gel in custom-trays the concentration of H2O2 was 73% at 5 min and 42% after 75 min. In the 20% CP gel it was 75% at 5 min and 39% after 75 min. Activity decreased linearly up to 75 min, where the mean concentration of H2O2 exceeded 35% for the CP and HP gels.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Alonso De La Peña V,Rodriguez Carreira A,Corral Aneiros R,López Ratón M,Guitián Rivera F

doi

10.4012/dmj.2012-317

subject

Has Abstract

pub_date

2013-01-01 00:00:00

pages

654-8

issue

4

eissn

0287-4547

issn

1881-1361

pii

DN/JST.JSTAGE/dmj/2012-317

journal_volume

32

pub_type

杂志文章
  • Evaluation of resin infiltration on demineralized root surface: An in vitro study.

    abstract::The aim of this study was to evaluate the effect of resin infiltration on root caries induced by Streptococcus mutans biofilms. Human premolar specimens were divided to 5 groups: negative control (NC), Clearfil SE Bond (SEB), Icon-etch120s+Icon-infiltrant (HA120), Icon-etch10s+Icon-infiltrant (HA10) and K-etchant10s+I...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-229

    authors: Zhou Y,Matin K,Shimada Y,Sumi Y,Tagami J

    更新日期:2017-03-31 00:00:00

  • Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.

    abstract::The corrosion behavior of three Ni-Ti alloys with compositions as commercial super-elastic orthodontic wires was investigated using polished plate specimens. Corrosion resistance was estimated by potentiodynamic polarization measurement in 0.9% NaCl and 1% lactic acid solutions and analysis of released metals by atomi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.31

    authors: Iijima M,Endo K,Ohno H,Mizoguchi I

    更新日期:1998-03-01 00:00:00

  • Relation between attractive force and keeper surface characteristics of iron-neodymium-boron magnetic attachment systems.

    abstract::The purpose of this study was to evaluate the influence of heating, cast bonding, and subsequent polishing procedures on attractive force of magnetic attachments. Two magnetic attachment systems with keepers of different chemical compositions (Hicorexslim 3013, 447J1; Magfit EX400, AUM20) were employed. Keepers examin...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.393

    authors: Ohashi N,Koizumi H,Ishikawa Y,Furuchi M,Matsumura H,Tanoue N

    更新日期:2007-05-01 00:00:00

  • Anisotropy of tensile strengths of bovine dentin regarding dentinal tubule orientation and location.

    abstract::The purpose of this study was to investigate the effects of the location and orientation of dentinal tubules in the tooth on tensile strengths of the dentin. Dumbbell-shaped specimens of 12 groups from various locations and dentinal tubule orientations were prepared. The tensile test was performed in distilled water a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.32

    authors: Inoue T,Takahashi H,Nishimura F

    更新日期:2002-03-01 00:00:00

  • A simplified numerical simulation method of bending properties for glass fiber cloth reinforced denture base resin.

    abstract::The purpose of this study was to propose a new numerical modeling of the glass fiber cloth reinforced denture base resin (GFRP). The proposed model is constructed with an isotropic shell, beam and orthotropic shell elements representing the outmost resin, interlaminar resin and glass fiber cloth, respectively. The pro...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.105

    authors: Tanimoto Y,Nishiwaki T,Nishiyama N,Nemoto K,Maekawa Z

    更新日期:2002-06-01 00:00:00

  • Micro-computed tomographic evaluation of a new enzyme solution for caries removal in deciduous teeth.

    abstract::This study evaluated a new enzyme solution (SFC-V) for dentin caries removal, and obtained results were compared with Carisolv. Both solutions were used with a prototype plastic instrument - this being a modified technique for Carisolv. Five carious deciduous teeth were sectioned, and both treatments were applied alte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.675

    authors: Clementino-Luedemann TN,Dabanoglu A,Ilie N,Hickel R,Kunzelmann KH

    更新日期:2006-12-01 00:00:00

  • Evaluation of temperature changes in the pulp chamber during polymerization of light-cured pulp-capping materials by using a VALO LED light curing unit at different curing distances.

    abstract::The aim of this study was to evaluate temperature changes in the pulp chamber during polymerization of four different pulp-capping materials using a LED-light-curing-unit in the contact and noncontact positions. A pulpal circulation mechanism was simulated to measure increases in temperature in four pulp-capping mater...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-274

    authors: Savas S,Botsali MS,Kucukyilmaz E,Sari T

    更新日期:2014-01-01 00:00:00

  • Self-cleaning ability of a photocatalyst-containing denture base material.

    abstract::This study examined the ability of a photocatalyst mixed in a denture base resin to decompose organic substances which adhered to the denture base resin surface. The photocatalyst was mixed with denture base resin at concentrations of 0, 5, 10, and 15% (w/w). Decomposition test, bending test, and surface roughness mea...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.179

    authors: Cheng Y,Sakai T,Moroi R,Nakagawa M,Sakai H,Ogata T,Terada Y

    更新日期:2008-03-01 00:00:00

  • Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys.

    abstract::The effects of dissolved-oxygen concentration and fluoride concentration on the corrosion behaviors of commercial pure titanium, Ti-6Al-4V and Ti-6Al-7Nb alloys and experimentally produced Ti-0.2Pd and Ti-0.5Pt alloys were examined using the corrosion potential measurements. The amount of dissolved Ti was analyzed by ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.83

    authors: Nakagawa M,Matsuya S,Udoh K

    更新日期:2002-06-01 00:00:00

  • Repair bond strength of bulk-fill resin composite: Effect of different adhesive protocols.

    abstract::This study evaluated the effect of different adhesive protocols on the shear bond strength (SBS) of bulk-fill resin composite repaired with bulk-fill or conventional composite. Cylindrical bulk-fill resin composite specimens were prepared and allocated into groups according to the bonding strategy: no treatment, Silan...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-291

    authors: Cuevas-Suárez CE,Nakanishi L,Isolan CP,Ribeiro JS,Moreira AG,Piva E

    更新日期:2020-03-31 00:00:00

  • Antimicrobial and antibiofilm activities of MTA supplemented with bismuth lipophilic nanoparticles.

    abstract::The objective of this work was to determine the antimicrobial and antibiofilm properties of mineral trioxide aggregate (MTA) supplemented with bismuth lipophilic nanoparticles (BisBAL NPs). The antimicrobial activity of the composite MTA-BisBAL NPs was determined by the disk diffusion assay, while antibiofilm activity...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-259

    authors: Hernandez-Delgadillo R,Del Angel-Mosqueda C,Solís-Soto JM,Munguia-Moreno S,Pineda-Aguilar N,Sánchez-Nájera RI,Chellam S,Cabral-Romero C

    更新日期:2017-07-26 00:00:00

  • Irrigation effectiveness of continuous ultrasonic irrigation system: An ex vivo study.

    abstract::This study evaluated the irrigation extrusion and smear layer (SL) removal of continuous ultrasonic irrigation (CUI). Forty root canals were shaped, embedded in warm sterile saline agar colored with 1% acid red, and distributed into four groups; three groups had the final irrigation sequence of sodium hypochlorite and...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-411

    authors: Jamleh A,Suda H,Adorno CG

    更新日期:2018-01-30 00:00:00

  • Grindability of alpha-case formed on cast titanium.

    abstract::The hardened alpha-case (alpha-case) layer inevitably forms on the surface of titanium castings when prepared by investment casting. Because the hardness of the alpha-case is incomparable to that of the interior structure, the perception exists that the alpha-case is difficult to remove during cutting, grinding and po...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.587

    authors: Koike M,Jacobson D,Chan KS,Okabe T

    更新日期:2009-09-01 00:00:00

  • Effects of incorporation of nano-fluorapatite particles on microhardness, fluoride releasing properties, and biocompatibility of a conventional glass ionomer cement (GIC).

    abstract::Present study evaluated effects of addition of Nanoparticles fluorapatite (Nano-FA) on microhardness and fluoride release of a Glass Ionomer Cement (GIC, Fuji IX GP Fast). Forty-eight specimens prepared, divided equally into 4 groups (2 with Nano-FA); after 24 h and one week Vickers microhardness (HV) was measured. Na...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-437

    authors: Moshaverinia M,Borzabadi-Farahani A,Sameni A,Moshaverinia A,Ansari S

    更新日期:2016-01-01 00:00:00

  • Mechanism by which porous structure is formed on the surface of gold alloy containing only Cu as base metal.

    abstract::Gold alloys with Cu contents of 10 mass%, 20%, and 30% were used for morphological observation of porous surface structures after heating at 800 degrees C in air followed by pickling with acid solution. With increasing Cu content in the gold alloy, the internal oxidation zone became well-developed in the alloy matrix....

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.503

    authors: Ohno H,Endo K,Haneda K,Tamura M,Hikita K

    更新日期:2005-12-01 00:00:00

  • Durability of diamond burs for the fabrication of ceramic crowns using dental CAD/CAM.

    abstract::The diamond burs of two dental CAD/CAM systems (GN and CD) were examined if they could be used to fabricate up to 21 ceramic full crowns without fracture. After one, 11, and 21 machining times, the surfaces of the diamond burs were observed and the number of particles captured on SEM pictures was counted. The average ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.134

    authors: Yara A,Ogura H,Shinya A,Tomita S,Miyazaki T,Sugai Y,Sakamoto Y

    更新日期:2005-03-01 00:00:00

  • The preparation of PLLA/calcium phosphate hybrid composite and its evaluation of biocompatibility.

    abstract::In tissue engineering, biodegradable polymer materials with both high biocompatibility and high strength are very important as scaffolds for long term use. Therefore, in this research, we tried to prepare the three types of poly(L-lactic acid) (PLLA)/calcium phosphate (CP) hybrid composite for a scaffold biomaterial. ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-117

    authors: Hamada Y,Fujitani W,Kawaguchi N,Daito K,Niido T,Uchinaka A,Mori S,Kojima Y,Manabe M,Nishida K,Arita K,Nakano T,Matsuura N

    更新日期:2012-01-01 00:00:00

  • Permeability of etching agent constituents through dentin.

    abstract::The in vitro dentin permeability of the constituents of two types of conventional phosphoric acid etching agents which had different viscosities, and their pH changes after being permeated dentin were investigated. It was recognized that, even though the etching was for a short time (one minute) followed by rinsing, t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.164

    authors: Ishikawa K,Ito S,Hata Y

    更新日期:1989-12-01 00:00:00

  • Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor.

    abstract::The purpose of this study was to evaluate the effect of various incremental filling techniques on adhesion between composite and cavity floor using light-cured resin composite. Black ABS resin and hybrid resin composite were used as mold materials--instead of dentin--for the preparation of cavities, and standardized t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.503

    authors: Chikawa H,Inai N,Cho E,Kishikawa R,Otsuki M,Foxton RM,Tagami J

    更新日期:2006-09-01 00:00:00

  • Effect of three metal priming agents on the bond strength of adhesive resin cement to Ag-Zn-Sn-In alloy and component metals.

    abstract::The aim of this study was to investigate the effect of three metal priming agents on the bond strength of adhesive resin cement to Silver-Zinc-Tin-Indium (Ag-Zn-Sn-In) alloy and pure Ag, Zn, Sn, and In. The specimens were air-abraded with alumina and then primed with one of three metal priming agents: V-Primer, Esteni...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-139

    authors: Imamura N,Kawaguchi T,Shimizu H,Takahashi Y

    更新日期:2018-03-30 00:00:00

  • Shear bond strengths of a single-step bonding system to enamel and dentin.

    abstract::An experimental primer was developed as a single-step bonding system for resin-modified glass ionomer cements (GIC). Efficacy of this primer on adhesion of resin-modified GICs and resin composite to enamel and dentin was evaluated by shear bond test and SEM observation. Good bond strengths to enamel were obtained (> 1...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.16.40

    authors: Nikaido T,Nakajima M,Higashi T,Kanemura N,Pereira PN,Tagami J

    更新日期:1997-06-01 00:00:00

  • Deformation properties of Ti-6A1-7Nb alloy castings for removable partial denture frameworks.

    abstract::Ti-6Al-7Nb alloy was cast into three differently designed, removable partial denture frameworks: Palatal strap (PS), Anterior-posterior bar (AP), and Horseshoe-shaped bar (HS). The vertical displacement and local strain of Ti-6Al-7Nb alloy frameworks were investigated to compare against those of Co-Cr alloy frameworks...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.497

    authors: Srimaneepong V,Yoneyama T,Wakabayashi N,Kobayashi E,Hanawa T,Doi H

    更新日期:2004-12-01 00:00:00

  • Measurement of the remaining dentin thickness using optical coherence tomography for crown preparation.

    abstract::This study aimed to investigate the maximum depth imaging and optical properties of the dentin near the pulp by using optical coherence tomography (OCT) and to explore the possibility of measuring the remaining dentin thickness (RDT). Human third molars were used. In experiment 1, the cuspal dentin blocks (0.50-mm to ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-303

    authors: Fujita R,Komada W,Nozaki K,Miura H

    更新日期:2014-01-01 00:00:00

  • High temperature characteristics and solidification microstructures of dental metallic materials part I: silver-palladium-copper-gold alloy.

    abstract::Ag-Pd-Cu-Au alloy was subjected to a Thermo-Mechanical Analyzer to investigate high temperature properties up to its liquidus temperature. Microstructural examination and elemental analysis with EPMA were also conducted in the solid/liquid mixture region. The following conclusions were obtained. (1) The solidus temper...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.227

    authors: Nagasawa S,Yoshida T,Mizoguchi T,Terashima N,Ito M,Platt JA,Oshida Y

    更新日期:2003-09-01 00:00:00

  • Development of casting investment preventing blackening of noble metal alloys part 1. Application of developed investment for Ag-Pd-Cu-Au alloy.

    abstract::The objective of this study is to develop a casting investment that prevents the blackening of the cast surface of noble metal alloys. The experimental investments were prepared using a gypsum-bonded investment in which the metallic powders such as boron (B), silicon (Si), aluminum (Al) and titanium (Ti) were added as...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.87

    authors: Kakuta K,Nakai A,Goto S,Wakamatsu Y,Yara A,Miyagawa Y,Ogura H

    更新日期:2003-03-01 00:00:00

  • Wear resistance of hybrid composite resin for crown material by the two-body sliding test.

    abstract::Comparative studies on two-body sliding wear resistance were performed between a hybrid composite resin and conventional light-curing composite veneering materials. This study investigated the wear resistance of hybrid composite resins compared with three composite resin veneering materials for 12%Au-Ag-Pd alloy, the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.225

    authors: Suese K,Kawazoe T

    更新日期:2002-09-01 00:00:00

  • The protective effect of resveratrol against dentin bonding agents-induced cytotoxicity.

    abstract::This study was designed to evaluate the cytotoxicity of four dentin bonding agents and the effects of an antioxidant addition. Group A: G-aenial Bond, Group B: Optibond All in One, Group C: Gluma Self Etch and Group D: Clearfil S(3) Bond were added to the medium using extract method. The cells were cultured with or wi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-079

    authors: Atalayin C,Armagan G,Konyalioglu S,Kemaloglu H,Tezel H,Ergucu Z,Keser A,Dagci T,Onal B

    更新日期:2015-01-01 00:00:00

  • Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites.

    abstract::This study sought to evaluate the effects of different staining solutions on the colour stability of nanocomposites compared with microhybrid resin and to evaluate the degree of conversion of these two materials. Two different shades of two different composites were cured in polytetraflouroethylene disk rings. Coffee,...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-267

    authors: Al Kheraif AA,Qasim SS,Ramakrishnaiah R,Ihtesham ur Rehman

    更新日期:2013-01-01 00:00:00

  • Titanium removable denture based on a one-metal rehabilitation concept.

    abstract::The use of a single metal for all restorations would be necessary because it protects against metal corrosion caused by the contact of different metals. For this "one-metal rehabilitation" concept, non-alloyed commercially pure (CP) titanium should be used for all restorations. Titanium frameworks have been cast and u...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-137

    authors: Ohkubo C,Sato Y,Nishiyama Y,Suzuki Y

    更新日期:2017-09-26 00:00:00

  • Experimental studies on the application of a porcelain-light-cured resin matrix system to the porcelain margin of metal-ceramic crowns.

    abstract::Application of a light-cured porcelain margin is a technique which has been developed recently. In this study, we compared the porcelain margin properties of the porcelain-light-cured resin matrix system and the traditional porcelain-water system, in terms of volumetric shrinkage, density, compressive strength, surfac...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.1

    authors: Lu YS,Yang HW

    更新日期:1995-06-01 00:00:00