Durability of diamond burs for the fabrication of ceramic crowns using dental CAD/CAM.

Abstract:

:The diamond burs of two dental CAD/CAM systems (GN and CD) were examined if they could be used to fabricate up to 21 ceramic full crowns without fracture. After one, 11, and 21 machining times, the surfaces of the diamond burs were observed and the number of particles captured on SEM pictures was counted. The average surface roughness of the crowns was also measured. All diamond burs could be used to fabricate 21 ceramic crowns without fracture. A significant decrease in the number of diamond particles was found on the surfaces of GN burs after 11 and 21 machining times, but not on those of CD burs. The average surface roughness of GN crowns significantly increased with increase in the number of machining times. A significant positive correlation was found between the average surface roughness and the number of diamond particles.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Yara A,Ogura H,Shinya A,Tomita S,Miyazaki T,Sugai Y,Sakamoto Y

doi

10.4012/dmj.24.134

keywords:

subject

Has Abstract

pub_date

2005-03-01 00:00:00

pages

134-9

issue

1

eissn

0287-4547

issn

1881-1361

journal_volume

24

pub_type

杂志文章
  • Influences of filler content and size on the color adjustment potential of nonlayered resin composites.

    abstract::The blending effect (BE) plays an important role in esthetics of the composite resin. The objective of this study was to determine the extents to which filler size and content affect the BE. Three types of fillers (0.7, 1.0, and 1.5 µm) were mixed at weight contents of 60, 70, 75, and 80%. This study simulated clinica...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-083

    authors: Suh YR,Ahn JS,Ju SW,Kim KM

    更新日期:2017-01-31 00:00:00

  • Color change of newly developed esthetic restorative material immersed in food-simulating solutions.

    abstract::Recently, an esthetic tooth coating material has been developed. The material consisted of a primer solution, a base coat, and a top coat. The purpose of this study, therefore, was to evaluate the color change of this tooth coating material and two resin composites after immersion in food-simulating, staining solution...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.352

    authors: Fujita M,Kawakami S,Noda M,Sano H

    更新日期:2006-06-01 00:00:00

  • Effect of new light curing units on microleakage and microhardness of resin sealants.

    abstract::To determine new developed light curing units with shorter curing times effects on microleakage and microhardness values for resin fissure sealants. Resin filled sealant (UltraSeal-XT), resin unfilled sealant (Delton Type-II) and ormocer-based sealant (Admira-Seal) were light cured with a quartz-tungsten-halogen (QTH)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-357

    authors: Bani M,Tirali RE

    更新日期:2016-01-01 00:00:00

  • Evaluation of the responses of MHC class II molecule-expressing cells and macrophages to epoxy resin-based and 4-META-containing, methacrylate resin-based root canal sealers in rat subcutaneous tissue.

    abstract::Major histocompatibility complex (MHC) class II molecule-expressing cells and macrophages play a pivotal role in mediating the host tissue response to biomaterials. This study investigated the responses of these cells to epoxy resin-based and 4-META-containing, methacrylate resin-based endodontic sealers (AH Plus and ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-005

    authors: Yamanaka Y,Shigetani Y,Yoshiba K,Kaneko T,Yoshiba N,Okiji T

    更新日期:2013-01-01 00:00:00

  • Effect of etching with low concentration hydrofluoric acid on the bond strength of CAD/CAM resin block.

    abstract::The effect of etching for 90 s with low concentrations (0.5, 1.0, 2.0, 3.0, 3.5, and 4.0%) of hydrofluoric acid (HF) on the adhesiveness of computer-aided design/computer-aided manufacturing (CAD/CAM) resin blocks [CERASMART (CS), SHOFU BLOCK HC (HC), KATANA AVENCIA Block(KA), and VITA ENAMIC (EN)] was investigated. E...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-398

    authors: Niizuma Y,Kobayashi M,Toyama T,Manabe A

    更新日期:2020-12-03 00:00:00

  • Effectiveness of sodium hypochlorite and sulfinic acid sodium salt treatment on dentin-resin bonding: Long-term durability of one-step self-etching adhesive.

    abstract::This study aimed to evaluate the effect of sulfinic acid sodium salt interposition after acid and sodium hypochlorite treatment (NC treatment) on dentin bonding durability using a mild type one-step self-etching adhesive. Fifteen human third molars were randomly assigned into three experimental groups according to den...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-105

    authors: Nakatani H,Mine A,Matsumoto M,Kabetani T,Kawaguchi-Uemura A,Higashi M,Tajiri Y,Imai D,Hagino R,Minamino T,Miura J,Yatani H

    更新日期:2017-11-29 00:00:00

  • Effect of application of desensitizers before bleaching on change of tooth shade.

    abstract::The aim of this in vitro study was to evaluate the effects of desensitizer pre-treatment on in-office bleaching using an artificial discoloration tooth model. The stained specimens were divided into four groups (n=10); without application (Control group), Shield Force plus (SF group), UltraEz (UE group) and Teeth Mate...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-129

    authors: Kyaw KY,Otsuki M,Hiraishi N,Segarra MS,Tagami J

    更新日期:2019-10-02 00:00:00

  • Flexural properties of resin-modified "hybrid" glass-ionomers in comparison with conventional acid-base glass-ionomers.

    abstract::The mechanical properties of resin-modified "hybrid" glass-ionomers, for both restorative and liner/base applications, were assessed by a flexural test and compared with those of conventional acid-base glass-ionomers. Flexural strength, flexural modulus, and the modulus of resilience were determined 30 minutes after m...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.109

    authors: Momoi Y,Hirosaki K,Kohno A,McCabe JF

    更新日期:1995-12-01 00:00:00

  • Application of thermography in dentistry--visualization of temperature distribution on oral tissues.

    abstract::The purpose of this study was to devise and propose appropriate conditions for the photographing of thermal images in the oral cavity and to evaluate which thermography techniques can be applied to dentistry by evaluating the differences in temperature among oral tissues. Thermal images of oral cavities of 20 voluntee...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.436

    authors: Komoriyama M,Nomoto R,Tanaka R,Hosoya N,Gomi K,Iino F,Yashima A,Takayama Y,Tsuruta M,Tokiwa H,Kawasaki K,Arai T,Hosoi T,Hirashita A,Hirano S

    更新日期:2003-12-01 00:00:00

  • Effect of surface modification on the photocatalysis of Ti-Ni alloy in orthodontics.

    abstract::Photocatalytic activity from the reaction of titanium oxide with ultraviolet light has recently gained much attention. In particular, there is scientific interest in inducing photocatalytic reactions on Ti-Ni alloy, a material widely used in orthodontic applications. However, it is believed that inducing a photocataly...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.924

    authors: Horiuchi Y,Horiuchi M,Hanawa T,Soma K

    更新日期:2007-11-01 00:00:00

  • Bond strength and microleakage of self-adhesive and conventional fissure sealants.

    abstract::The aim of this study was to compare the shear bond strengths (SBS), failure modes (adhesive, cohesive, or mixed), and marginal microleakage occurrence of conventional resin (CR)-based, glass ionomer (GI)-based, and self-adhesive resin (SAR)-based fissure sealants with or without prior phosphoric acid (PA) etching. Fi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-227

    authors: Simsek Derelioglu S,Yilmaz Y,Celik P,Carikcioglu B,Keles S

    更新日期:2014-01-01 00:00:00

  • Effect of casting methods on castability of pure titanium.

    abstract::Two types of patterns were tested for castability: 1) polyester mesh pattern (20mm x 22mm with 100 open squares) and 2) 20mm x 20mm wax plates 1.0 and 1.5 mm in thickness. These materials were invested using a pre-arranged commercial phosphate-bonded investment for titanium. Three different types of casting machines w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.245

    authors: Takahashi J,Zhang JZ,Okazaki M

    更新日期:1993-12-01 00:00:00

  • Comparative analysis of bovine serum albumin adsorption onto octacalcium phosphate crystals prepared using different methods.

    abstract::This study compared bovine serum albumin (BSA) adsorption onto octacalcium phosphate (OCP) materials prepared from two wet preparations in the absence (w-OCP) and presence (c-OCP) of gelatin. Raman spectroscopy was used to analyze the BSA adsorption onto OCPs in a 150 mM Tris-HCl buffer containing 0.5 mM calcium and i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-250

    authors: Tsuchiya K,Hamai R,Sakai S,Suzuki O

    更新日期:2020-09-29 00:00:00

  • Efficacy of dentin bonding to cervical defects.

    abstract::The bonding efficacy of sclerotic dentin was determined by measuring the polymerization contraction gap width of a commercial light-activated resin composite in a cervical defect and by measuring the micro-Vicker's hardness at the dentin adhesive surface; morphological characteristics were observed using a scanning el...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.359

    authors: Tani C,Itoh K,Hisamitsu H,Wakumoto S

    更新日期:2001-12-01 00:00:00

  • Repair bond strength of bulk-fill resin composite: Effect of different adhesive protocols.

    abstract::This study evaluated the effect of different adhesive protocols on the shear bond strength (SBS) of bulk-fill resin composite repaired with bulk-fill or conventional composite. Cylindrical bulk-fill resin composite specimens were prepared and allocated into groups according to the bonding strategy: no treatment, Silan...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-291

    authors: Cuevas-Suárez CE,Nakanishi L,Isolan CP,Ribeiro JS,Moreira AG,Piva E

    更新日期:2020-03-31 00:00:00

  • Swelling/deswelling mechanism of calcium alginate gel in aqueous solutions.

    abstract::To elucidate the mechanism of dimensional changes in alginate impression in solutions, the relationship between the ion concentrations in three types of solutions (nonelectrolyte and monovalent and divalent metallic salts) and change in gel volume was examined. The gel in the monovalent metallic salt solution expanded...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.396

    authors: Saitoh S,Araki Y,Kon R,Katsura H,Taira M

    更新日期:2000-12-01 00:00:00

  • Initial and long-term bond strengths of one-step self-etch adhesives with silane coupling agent to enamel-dentin-composite in combined situation.

    abstract::This study evaluated the effect of adding silane coupling agent on initial and long-term bond strengths of one-step self-etch adhesives to enamel-dentin-composite in combined situation. Cervical cavities were prepared on extracted molars and filled with Clearfil AP-X. After water-storage for one-week, the filled teeth...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-050

    authors: Mamanee T,Takahashi M,Nakajima M,Foxton RM,Tagami J

    更新日期:2015-01-01 00:00:00

  • Surface effects after a combination of dental bleaching and enamel microabrasion: An in vitro and in situ study.

    abstract::This study evaluated the effects of combining enamel microabrasion and dental bleaching on the physical properties of enamel, using in vitro and in situ conditions and evaluating surface roughness, enamel microhardness and scanning electron microscopy images. One hundred sound bovine teeth were sectioned and cut into ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-334

    authors: Franco LM,Machado LS,Salomão FM,Dos Santos PH,Briso AL,Sundfeld RH

    更新日期:2016-01-01 00:00:00

  • Influence of thin carbonate-containing apatite coating with molecular precursor method to zirconia on osteoblast-like cell response.

    abstract::The influence of a thin carbonate-containing hydroxyapatite (CA) coating to tetragonal zirconia polycrystal (TZP) on osteoblastlike cell response was investigated. TZP disks were subjected to blasting and acid etching. Thin CA coatings were deposited by the molecular precursor method (TZP-CA). Initial cell adhesion of...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-122

    authors: Kaneko H,Sasaki H,Honma S,Hayakawa T,Sato M,Yajima Y,Yoshinari M

    更新日期:2014-01-01 00:00:00

  • Effects of dental porcelain containing silver nanoparticles on static fatigue.

    abstract::The purpose of this study was to clarify the effect of silver nanoparticles on the behavior of subcritical crack growth (SCG) in dental porcelains. Prior to occurrence of fast fracture in dental porcelains, SCG occurs and leads to strength degradation over time. SCG in dental porcelains can be characterized by the str...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-266

    authors: Fujieda T,Uno M,Ishigami H,Kurachi M,Kamemizu H,Wakamatsu N,Doi Y

    更新日期:2013-01-01 00:00:00

  • Wear resistance of hybrid composite resin for crown material by the two-body sliding test.

    abstract::Comparative studies on two-body sliding wear resistance were performed between a hybrid composite resin and conventional light-curing composite veneering materials. This study investigated the wear resistance of hybrid composite resins compared with three composite resin veneering materials for 12%Au-Ag-Pd alloy, the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.225

    authors: Suese K,Kawazoe T

    更新日期:2002-09-01 00:00:00

  • Influence of silane heat treatment on bond strength of resin cement to a feldspathic ceramic.

    abstract::This study evaluated the influence of heat treatment (HT) of the silane on the microtensile bond strength of resin cement to a feldspathic ceramic. Ceramic (VITA VM7) and composite blocks (N=32) were divided into four groups (n=6 for bond test, n=2 for SEM) at random and subject to following sequence of conditioning: ...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:

    authors: de Carvalho RF,Martins ME,de Queiroz JR,Leite FP,Ozcan M

    更新日期:2011-01-01 00:00:00

  • Micro computed tomography evaluation of the Self-adjusting file and ProTaper Universal system on curved mandibular molars.

    abstract::The aim of this investigation was to compare the cleaning and shaping efficiency of Self-adjusting file and Protaper, and to assess the correlation between root canal curvature and working time in mandibular molars using micro-computed tomography. Twenty extracted mandibular molars instrumented with Protaper and Self-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-255

    authors: Serefoglu B,Piskin B

    更新日期:2017-09-26 00:00:00

  • Analysis of abutment tooth movement utilizing mandibular kinesiography (MKG). Part 2. Effects of clasp design in unilateral free-end denture.

    abstract::The three-dimensional dynamic movement of the abutment tooth was successfully analyzed on a simulation model utilizing the mandibular kinesiography. When the unilateral free-end denture retained by the RPA, RPI or Aker's clasp was subjected to various directions of loads, the abutment tooth was inclined mainly by the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.56

    authors: Morikawa M,Masumi S,Kido H,Toyoda S,Kozono Y

    更新日期:1989-06-01 00:00:00

  • Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites.

    abstract::This study sought to evaluate the effects of different staining solutions on the colour stability of nanocomposites compared with microhybrid resin and to evaluate the degree of conversion of these two materials. Two different shades of two different composites were cured in polytetraflouroethylene disk rings. Coffee,...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-267

    authors: Al Kheraif AA,Qasim SS,Ramakrishnaiah R,Ihtesham ur Rehman

    更新日期:2013-01-01 00:00:00

  • Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin.

    abstract::The aim of this study was to investigate in how far the way the specimen is fixed to the testing device influences the micro-tensile bond strength of adhesives to dentin. Compared to a flat jig, a notched jig enables the specimen to be aligned easier and more accurately perpendicular to the interface, thereby concentr...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.694

    authors: Poitevin A,De Munck J,Van Landuyt K,Coutinho E,Peumans M,Lambrechts P,Van Meerbeek B

    更新日期:2007-09-01 00:00:00

  • The effect of magnesium oxide supplementation to aluminum oxide slip on the jointing of aluminum oxide bars.

    abstract::The purpose of this study was to investigate the effect of modifying aluminum oxide slips with magnesium oxide (MgO) to create a jointing material for In-Ceram Alumina. Jointed In-Ceram Alumina bars with In-Ceram Alumina slips containing 0-1.0 mass% MgO were examined by a three-point bending test. Joint-free bars were...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.251

    authors: Odatsu T,Sawase T,Kamada K,Taira Y,Shiraishi T,Atsuta M

    更新日期:2008-03-01 00:00:00

  • Genetic potential of interfacial guided osteogenesis in implant devices.

    abstract::The purpose of this review is to summarise recent advances in the design and composition of bioactive surface layers of implantabile biomaterials, and thus the genetic potential of osteoprogenitor cells to recognize and respond to these diverse implanted biomaterials. Changes applied to a biomaterial's surface, in gen...

    journal_title:Dental materials journal

    pub_type: 杂志文章,评审

    doi:10.4012/dmj.19.99

    authors: Letić-Gavrilović A,Scandurra R,Abe K

    更新日期:2000-06-01 00:00:00

  • Antibacterial and pro-osteogenic effects of β-Defensin-2-loaded mesoporous bioglass.

    abstract::The human antimicrobial peptide beta-defensin-2 (hBD2) shows broad antibacterial activity and infrequent bacterial resistance. Here mesoporous bioactive glass (MBG) was loaded with hBD2, forming hBD2-loaded MBG (BD-MBG). The antibacterial and osteogenic effects of BD-MBG were investigated in comparison with MBG and th...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-105

    authors: Ren L,Zhang Z,Deng C,Zhang N,Li D

    更新日期:2020-12-24 00:00:00

  • Immobilization of octadecyl ammonium chloride on the surface of titanium and its effect on microbial colonization in vitro.

    abstract::The aim of our study was twofold: to immobilize an organosilicon quaternary ammonium salt (3-(trimethoxysilyl)-propyldimethyl-octadecyl ammonium chloride, Si-QAC) on the surface of pure titanium and to investigate the antimicrobial activity of Si-QAC-immobilized titanium against microbial adherence and biofilm formati...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.570

    authors: Nikawa H,Ishida K,Hamada T,Satoda T,Murayama T,Takemoto T,Tamamoto M,Tajima H,Shimoe S,Fujimoto H,Makihira S

    更新日期:2005-12-01 00:00:00