Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin.

Abstract:

:The aim of this study was to investigate in how far the way the specimen is fixed to the testing device influences the micro-tensile bond strength of adhesives to dentin. Compared to a flat jig, a notched jig enables the specimen to be aligned easier and more accurately perpendicular to the interface, thereby concentrating better the tensile stress at the actual interface. A notched jig yielded a significantly higher bond strength and the graphs showed more uniform fracture curves. On the other hand, fixation of the specimen at their top and bottom guarantees a perfect perpendicular fixation to the interface, following the specimen's length-axis. The stress-time graphs revealed a completely different stress-distribution pattern. A failure closer to the dentin-composite interface was more often seen and the coefficient of variance was the lowest. Therefore, this completely newly designed top-bottom set-up produced the most reliable bond strength data.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Poitevin A,De Munck J,Van Landuyt K,Coutinho E,Peumans M,Lambrechts P,Van Meerbeek B

doi

10.4012/dmj.26.694

subject

Has Abstract

pub_date

2007-09-01 00:00:00

pages

694-9

issue

5

eissn

0287-4547

issn

1881-1361

journal_volume

26

pub_type

杂志文章
  • Bactericidal efficacy of glycine-type amphoteric surfactant as a denture cleaner and its influence on properties of denture base resins.

    abstract::The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.307

    authors: Hashiguchi M,Nishi Y,Kanie T,Ban S,Nagaoka E

    更新日期:2009-05-01 00:00:00

  • Application of thermography in dentistry--visualization of temperature distribution on oral tissues.

    abstract::The purpose of this study was to devise and propose appropriate conditions for the photographing of thermal images in the oral cavity and to evaluate which thermography techniques can be applied to dentistry by evaluating the differences in temperature among oral tissues. Thermal images of oral cavities of 20 voluntee...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.436

    authors: Komoriyama M,Nomoto R,Tanaka R,Hosoya N,Gomi K,Iino F,Yashima A,Takayama Y,Tsuruta M,Tokiwa H,Kawasaki K,Arai T,Hosoi T,Hirashita A,Hirano S

    更新日期:2003-12-01 00:00:00

  • The hydration chemistry of ProRoot MTA.

    abstract::'Tooth-coloured' ProRoot MTA is an endodontic cement comprising an 80:20 wt% mixture of white Portland cement (WPC) and bismuth oxide. The setting reactions within this cement system are not currently well understood. Accordingly, this research monitors the early hydration chemistry of ProRoot MTA by X-ray diffraction...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-309

    authors: Li Q,Coleman NJ

    更新日期:2015-01-01 00:00:00

  • Mold filling and microhardness of 1% Fe titanium alloys.

    abstract::We examined the mold filling capacity and microhardness of two industrial 1% Fe titanium alloys: Super-TIX800 (Nippon Steel Corp.) (Fe: 0.910%, O: 0.370%, N: 0.005%) and Super-TIX800N (Nippon Steel Corp.) (Fe: 0.960%, O: 0.300%, N: 0.041%). Two wedge-shaped acrylic patterns (with 30 degrees or 15 degrees angles) were ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.211

    authors: Sato H,Komatsu M,Miller B,Shimizu H,Fujii H,Okabe T

    更新日期:2004-06-01 00:00:00

  • Effect of finishing condition on fracture strength of monolithic zirconia crowns.

    abstract::This study was to evaluate the load bearing capacity of monolithic dental zirconia crowns, and the effect of surface finishing on fracture strength. (1) The zirconia plates were divided into 5 groups and polished by various types of polishing bur, every specimen was analyzed by surface roughness testing, and X-ray dif...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-391

    authors: Yin R,Lee MH,Bae TS,Song KY

    更新日期:2019-03-31 00:00:00

  • High temperature characteristics and solidification microstructures of dental metallic materials part I: silver-palladium-copper-gold alloy.

    abstract::Ag-Pd-Cu-Au alloy was subjected to a Thermo-Mechanical Analyzer to investigate high temperature properties up to its liquidus temperature. Microstructural examination and elemental analysis with EPMA were also conducted in the solid/liquid mixture region. The following conclusions were obtained. (1) The solidus temper...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.227

    authors: Nagasawa S,Yoshida T,Mizoguchi T,Terashima N,Ito M,Platt JA,Oshida Y

    更新日期:2003-09-01 00:00:00

  • Influence of a denture strengthener on the deformation of a maxillary complete denture.

    abstract::The present study investigated the influences of a denture strengthener on the deformation of a maxillary complete denture. Three groups of maxillary complete dentures were fabricated (Group 1 without a strengthener; Group 2 with a Co-Cr alloy wire strengthener; Group 3 with an experimental fiberglass strengthener). T...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.507

    authors: Hirajima Y,Takahashi H,Minakuchi S

    更新日期:2009-07-01 00:00:00

  • SEM observation of collagen fibrils secreted from the body surface of osteoblasts on a CO3apatite-collagen sponge.

    abstract::The secretion of collagen by osteoblasts was observed by scanning electron microscopy (SEM). Osteoblast-like cells were cultured on a CO3apatite-collagen sponge reinforced with a porous HAp frame. After three days' incubation, a number of newly created matrix fibrils, forming a network structure, were observed at the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.460

    authors: Hirata I,Nomura Y,Tabata H,Miake Y,Yanagisawa T,Okazaki M

    更新日期:2005-09-01 00:00:00

  • Effect of casting methods on castability of pure titanium.

    abstract::Two types of patterns were tested for castability: 1) polyester mesh pattern (20mm x 22mm with 100 open squares) and 2) 20mm x 20mm wax plates 1.0 and 1.5 mm in thickness. These materials were invested using a pre-arranged commercial phosphate-bonded investment for titanium. Three different types of casting machines w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.245

    authors: Takahashi J,Zhang JZ,Okazaki M

    更新日期:1993-12-01 00:00:00

  • Clinical evaluation of an electron-ionizing toothbrush with a tooth paste containing stannous fluoride in treatment of dentine hypersensitivity following periodontal surgery.

    abstract::The purpose of this study was to examine the effect of an electro-ionizing toothbrush with stannous fluoride in the treatment of dentin hypersensitivity following periodontal surgery. Thirty-two volunteers with dentin hypersensitivity were divided in two equal groups each using different methods: (Group I) stannous fl...

    journal_title:Dental materials journal

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.4012/dmj.20.164

    authors: Orbak R,Canakçi V,Tezel A

    更新日期:2001-06-01 00:00:00

  • Fluorescence of thulium-doped translucent zirconia.

    abstract::The fluorescence and physical properties of thulium-doped zirconia were investigated. A standard grade of zirconia (TZ-3Y-E) and two translucent dental zirconia materials (Zpex and Zpex Smile) were examined. The specimens were prepared by addition of 0-1.5 wt% Tm2O3 and then sintering. When exposed to UV light, the Tm...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-384

    authors: Nakamura T,Okamura S,Nishida H,Usami H,Nakano Y,Wakabayashi K,Sekino T,Yatani H

    更新日期:2018-11-30 00:00:00

  • Effects of dental porcelain containing silver nanoparticles on static fatigue.

    abstract::The purpose of this study was to clarify the effect of silver nanoparticles on the behavior of subcritical crack growth (SCG) in dental porcelains. Prior to occurrence of fast fracture in dental porcelains, SCG occurs and leads to strength degradation over time. SCG in dental porcelains can be characterized by the str...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-266

    authors: Fujieda T,Uno M,Ishigami H,Kurachi M,Kamemizu H,Wakamatsu N,Doi Y

    更新日期:2013-01-01 00:00:00

  • Evaluation of a hydrogel membrane on bone regeneration in furcation periodontal defects in dogs.

    abstract::The aim of the study was to evaluate bone regeneration using a canine model with surgically created periodontal defects filled for 12 weeks using a stratified biomaterial consisting in a biphasic calcium phosphate (BCP) covered with a crosslinking hydrogel acting as polymer membrane of silated hydroxypropyl methylcell...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-238

    authors: Struillou X,Fruchet A,Rakic M,Badran Z,Rethore G,Sourice S,Fellah BH,LE Guehennec L,Gauthier O,Weiss P,Soueidan A

    更新日期:2018-09-30 00:00:00

  • Long-term evaluation of warm-air treatment effect on adaptation of silane-containing universal adhesives to lithium disilicate ceramic.

    abstract::The effect of warm air-blowing on the sealing ability of two one-bottle and one two-bottle silane-containing universal adhesives (UAs) applied to lithium disilicate ceramics (LDS) was evaluated. Tapered cavities prefabricated in LDS blocks (IPS e.max CAD) were treated by the adhesives, air-blown either with normal air...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-057

    authors: Kaykhine P,Tichy A,Abdou A,Hosaka K,Foxton RM,Sumi Y,Nakajima M,Tagami J

    更新日期:2020-10-24 00:00:00

  • Flexural properties of resin-modified "hybrid" glass-ionomers in comparison with conventional acid-base glass-ionomers.

    abstract::The mechanical properties of resin-modified "hybrid" glass-ionomers, for both restorative and liner/base applications, were assessed by a flexural test and compared with those of conventional acid-base glass-ionomers. Flexural strength, flexural modulus, and the modulus of resilience were determined 30 minutes after m...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.109

    authors: Momoi Y,Hirosaki K,Kohno A,McCabe JF

    更新日期:1995-12-01 00:00:00

  • Bond strength of artificial teeth to thermoplastic denture base resin for injection molding.

    abstract::This research was conducted to investigate the bond strength between artificial teeth and a thermoplastic denture base resin for injection molding with different surface preparations for use in flexible resin removable partial dentures. Composite resin denture teeth and acrylic denture resin teeth were bonded to three...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-183

    authors: Tashiro S,Kawaguchi T,Hamanaka I,Takahashi Y

    更新日期:2021-01-15 00:00:00

  • Effects of temperature-responsive hydrogel on viscosity of denture adhesives.

    abstract::The cream type of denture adhesives after use cannot be easily removed from oral mucosa and have the potential risk to change the oral flora. The effects of the temperature-responsive hydrogel Pluronic F-127 (PF) on the complex viscosity of denture adhesives were evaluated. Carboxy methylcellulose (CMC) mass fractions...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-191

    authors: Zhao H,Akiba N,Tanimoto H,Yoshizaki T,Yalikun K,Minakuchi S

    更新日期:2016-01-01 00:00:00

  • Permeability of etching agent constituents through dentin.

    abstract::The in vitro dentin permeability of the constituents of two types of conventional phosphoric acid etching agents which had different viscosities, and their pH changes after being permeated dentin were investigated. It was recognized that, even though the etching was for a short time (one minute) followed by rinsing, t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.164

    authors: Ishikawa K,Ito S,Hata Y

    更新日期:1989-12-01 00:00:00

  • Effects of different luting cements and light curing units on the sealing ability and bond strength of fiber posts.

    abstract::This study evaluated the sealing ability and push-out bond strength of two luting cements cured with two different types of light curing units (LCU): light-emitting diode (LED) versus quartz tungsten halogen (QTH). Forty teeth were divided into four groups(n=10/group). Quartz fiber posts (D. T. Light-Post) were luted ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-209

    authors: Beriat NC,Ertan AA,Yilmaz Z,Gulay G,Sahin C

    更新日期:2012-01-01 00:00:00

  • Evaluation of temperature changes in the pulp chamber during polymerization of light-cured pulp-capping materials by using a VALO LED light curing unit at different curing distances.

    abstract::The aim of this study was to evaluate temperature changes in the pulp chamber during polymerization of four different pulp-capping materials using a LED-light-curing-unit in the contact and noncontact positions. A pulpal circulation mechanism was simulated to measure increases in temperature in four pulp-capping mater...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-274

    authors: Savas S,Botsali MS,Kucukyilmaz E,Sari T

    更新日期:2014-01-01 00:00:00

  • Influence of ultraviolet irradiation treatment on porcelain bond strength of titanium surfaces.

    abstract::To determine the effect of titanium (Ti) surface modification by ultraviolet irradiation (UVI) on the bond strength between Ti and porcelain. Grade 2 Ti plates were allotted to five groups: sandblasted (SA), 15 min UVI (UV), SA+5 min UVI (SA+UV5), SA+10 min UVI (SA+UV10), and SA+15 min UVI (SA+UV15). After surface tre...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-417

    authors: Kumasaka T,Ohno A,Hori N,Hoshi N,Maruo K,Kuwabara A,Seimiya K,Toyoda M,Kimoto K

    更新日期:2018-06-08 00:00:00

  • Transformation behavior of nickel-titanium orthodontic wires under tensile load.

    abstract::This study investigated transformations of nickel-titanium wires using differential scanning calorimetry (DSC) and thermomechanical analysis (TMA) under tensile load (100 gf or 500 gf). Two nickel-titanium wires, 35°C Copper Ni-Ti and Nitinol SE, were selected. DSC analyses were performed between -90° and 100°C. Speci...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-196

    authors: Iijima M,Ohta M,Brantley WA,Naganishi A,Murakami T,Muguruma T,Mizoguchi I

    更新日期:2011-01-01 00:00:00

  • Contraction gap versus shear bond strength of dentin adhesive in sound and sclerotic dentins.

    abstract::To evaluate the effect of a dentin adhesive on sclerotic dentin, contraction gap width and shear bond strength were measured. Dentin cavity wall was pretreated with an experimental dentin bonding system with and without a dentin primer, or with a commercial dentin bonding system. In the experimental dentin bonding gro...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.576

    authors: Kusunoki M,Itoh K,Takahashi Y,Hisamitsu H

    更新日期:2006-09-01 00:00:00

  • Water durability of resin bond to pure gold treated with various adhesion promoting thiirane monomers.

    abstract::Adhesion promoting monomers for precious metals, 2,3-epithiopropyl methacrylate (EP1MA), 4,5-epithiopentyl methacrylate (EP3MA), 9,10-epithiodecyl methacrylate (EP8MA), 10,11-epithioundecyl methacrylate (EP9MA), 9,10-epithiodecyl 4-vinylbenzoate (EP8VB), 2,3-epithiocyclohexyl methacrylate (EPCHMA), and 3,4-epithiobuty...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.29

    authors: Kadoma Y,Kojima K,Tamaki Y,Nomura Y

    更新日期:2007-01-01 00:00:00

  • Initial and long-term bond strengths of one-step self-etch adhesives with silane coupling agent to enamel-dentin-composite in combined situation.

    abstract::This study evaluated the effect of adding silane coupling agent on initial and long-term bond strengths of one-step self-etch adhesives to enamel-dentin-composite in combined situation. Cervical cavities were prepared on extracted molars and filled with Clearfil AP-X. After water-storage for one-week, the filled teeth...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-050

    authors: Mamanee T,Takahashi M,Nakajima M,Foxton RM,Tagami J

    更新日期:2015-01-01 00:00:00

  • Analysis of fracture surface of titanium-porcelain bonding by electron spectroscopy for chemical analysis.

    abstract::Three commercially available porcelains bonded to titanium were evaluated to determine the weakest zone of the titanium-porcelain bonding structures. Tensile bond tests were performed for these specimens (NO, DU, and VI) and for Ni-Cr alloy-porcelain bonding samples that served as controls. The maximum bond strengths ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-263

    authors: Kannari Y,Endo K,Ida Y,Ochi M,Ohno H

    更新日期:2014-01-01 00:00:00

  • Effect of dentin cleansers on the bonding efficacy of dentin adhesive.

    abstract::The relation between the bonding efficacy of the dentin adhesive and the physical change of the dentin after treatment with various dentin cleansers was investigated. The dentin surface was cleaned with one of the seven experimental dentin cleansers, 5, 10, 20, 30 and 40% of the phosphoric acid, neutralized 0.5 M EDTA...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.76

    authors: Chiba M,Itoh K,Wakumoto S

    更新日期:1989-06-01 00:00:00

  • Bioactive-glass in periodontal surgery and implant dentistry.

    abstract::Bioactive-glass (B-G) is a material known for its favorable biological response when in contact with surrounding fibro-osseous tissues, due not only to an osteoconductive property, but also to an osteostimulatory capacity, and superior biocompatibility for use in human body. The objectives of this paper are to review ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-233

    authors: Profeta AC,Prucher GM

    更新日期:2015-01-01 00:00:00

  • Measurement of exothermic heat released during polymerization of a lightcuring composite resin: Comparison of light irradiation modes.

    abstract::High-power light-curing units have emerged that reduce the time of procedures in dental clinical work. However, patients sometimes complain of pain during the polymerization of composite resin. In this experiment, we investigated how differences in light-curing mode affect the temperature rise during composite resin p...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-158

    authors: Hori M,Fujimoto K,Asakura M,Nagase Y,Mieki A,Kawai T

    更新日期:2019-07-31 00:00:00

  • Light activated resin containing organic dyestuff.

    abstract::The physical properties of experimental visible light-activated resins containing dyestuff, which could be quickly discolored by irradiation was, evaluated by analyzing light absorbance characteristics and measuring micro Vickers hardness. The experimental resin, which was prepared by mixing equivalent weights of Bis ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.147

    authors: Nakazato J,Itoh K,Wakumoto S

    更新日期:1989-12-01 00:00:00