Fluorescence of thulium-doped translucent zirconia.

Abstract:

:The fluorescence and physical properties of thulium-doped zirconia were investigated. A standard grade of zirconia (TZ-3Y-E) and two translucent dental zirconia materials (Zpex and Zpex Smile) were examined. The specimens were prepared by addition of 0-1.5 wt% Tm2O3 and then sintering. When exposed to UV light, the Tm2O3-doped zirconia exhibited blue fluorescence with a peak wavelength of 460 nm. The fluorescence intensity of Zpex and Zpex Smile was higher than that of TZ-3Y-E, with Zpex being more intense than Zpex Smile. Zpex exhibited maximum fluorescence intensity when doped with 0.8 wt% Tm2O3. XRD analysis revealed that TZ-3Y-E and Zpex contained primarily tetragonal zirconia, while Zpex Smile contained largely cubic phase zirconia. There were no changes observed in the microstructure or physical properties of the zirconia specimens when doped with Tm2O3.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Nakamura T,Okamura S,Nishida H,Usami H,Nakano Y,Wakabayashi K,Sekino T,Yatani H

doi

10.4012/dmj.2017-384

subject

Has Abstract

pub_date

2018-11-30 00:00:00

pages

1010-1016

issue

6

eissn

0287-4547

issn

1881-1361

journal_volume

37

pub_type

杂志文章
  • Comparison of the cytogenotoxicity induced by five different dental alloys using four in vitro assays.

    abstract::The purpose of present investigation was to compare the cyto-genotoxicity induced by five dental alloys in vitro. The cyto-genotoxicity induced by five dental alloy extracts on human B lymphoblast cells was assessed with neutral red uptake (NRU) , CCK-8, comet and micronucleus (CBMN) assays in vitro, respectively. The...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-127

    authors: Zhihong C,Yezhen L,Zhiyuan G,Zhongqiao Y,Xiaoxue L,Yifeng R,Weikun F,Jiliang H

    更新日期:2011-01-01 00:00:00

  • Pre-treatment of radicular dentin by self-etch primer containing chlorhexidine can improve fiber post bond durability.

    abstract::We evaluated whether the pre-treatment of radicular dentin by ED Primer containing different concentrations of chlorhexidine can improve the bond durability of fiber post to radicular dentin. Experimental ED primers containing different concentrations of chlorhexidine (0%, 0.5% and 1.0%) were prepared. Thirty extracte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-134

    authors: Zhou J,Yang X,Chen L,Liu X,Ma L,Tan J

    更新日期:2013-01-01 00:00:00

  • Diffusion of GM primer and dentin adhesive into EDTA-conditioned dentin.

    abstract::The aim of this study was to investigate the diffusion of red-stained experimental GM primer and blue-stained dentin bonding agent into EDTA-conditioned dentin and the effect of GM priming on contraction gap formation. After GM priming at 0, 35, 70, or 100 vol%, marginal adaptation was evaluated by measuring the wall-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2009-084

    authors: Nasu Y,Itoh K,Tani C,Hisamitsu H

    更新日期:2010-10-01 00:00:00

  • SEM observation of collagen fibrils secreted from the body surface of osteoblasts on a CO3apatite-collagen sponge.

    abstract::The secretion of collagen by osteoblasts was observed by scanning electron microscopy (SEM). Osteoblast-like cells were cultured on a CO3apatite-collagen sponge reinforced with a porous HAp frame. After three days' incubation, a number of newly created matrix fibrils, forming a network structure, were observed at the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.460

    authors: Hirata I,Nomura Y,Tabata H,Miake Y,Yanagisawa T,Okazaki M

    更新日期:2005-09-01 00:00:00

  • Changes on NiTi orthodontic wired due to acidic fluoride solution.

    abstract::The effect of acidic fluoride solution on NiTi arch wires was examined by testing crystal structure, tensile strength, morphology after fracture, and element release from wire under four different test solutions after 1 or 3 d immersion. Three-day immersion in a 0.2%/pH 4 solution did not form any new crystal structur...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.557

    authors: Kwon YH,Cheon YD,Seol HJ,Lee JH,Kim HI

    更新日期:2004-12-01 00:00:00

  • Modification of electrochemically deposited apatite using supercritical water.

    abstract::Supercritical water was used as a modification method of electrochemically deposited apatite on pure titanium. The apatites were coated on a commercially pure titanium plate using a hydrothermal-electrochemical method. A constant direct current at 12.5 mA/cm2 was loaded for 1 hr at 25, 60, 100, 150 and 200 degrees C i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.247

    authors: Ban S,Hasegawa J

    更新日期:2001-12-01 00:00:00

  • Effect of thermocycling on the durability of etch-and-rinse and self-etch adhesives on dentin.

    abstract::The objective was to compare bond strengths of adhesives with/without thermocycling and to analyze the micromorphology of resindentin interfaces. Flat dentin surfaces were prepared and divided into eight groups to bond with four etch-and-rinse adhesives (Optibond FL, Adper Scotchbond Multi-Purpose, Optibond Solo Plus,...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-253

    authors: Sangwichit K,Kingkaew R,Pongprueksa P,Senawongse P

    更新日期:2016-01-01 00:00:00

  • Influence of resin coating on bond strength of self-adhesive resin cements to dentin.

    abstract::This study evaluated the effect of resin coating (COA) on dentin bond strength (BS) of five resin cements (RC). Ten groups were tested, according to RC and COA combinations. RCs were applied onto prepolymerized resin discs, which were bonded to dentin surfaces. Teeth were stored in water for 24 h, subjected to 5,000 t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-099

    authors: Giannini M,Takagaki T,Bacelar-Sá R,Vermelho PM,Ambrosano GM,Sadr A,Nikaido T,Tagami J

    更新日期:2015-01-01 00:00:00

  • Bond strength of artificial teeth to thermoplastic denture base resin for injection molding.

    abstract::This research was conducted to investigate the bond strength between artificial teeth and a thermoplastic denture base resin for injection molding with different surface preparations for use in flexible resin removable partial dentures. Composite resin denture teeth and acrylic denture resin teeth were bonded to three...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-183

    authors: Tashiro S,Kawaguchi T,Hamanaka I,Takahashi Y

    更新日期:2021-01-15 00:00:00

  • Cytotoxic effects of contemporary bulk-fill dental composites: A real-time cell analysis.

    abstract::The aim of this study was to evaluate the cytotoxicity of contemporary flowable and paste-like bulk-fill dental composites by using a real-time cell analysis. In the present paper, cytotoxicity levels of five flowable, five paste-like bulk-fill composite materials and one conventional flowable, one conventional paste-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-336

    authors: Demirel G,Gür G,Demirsoy FF,Altuntaş EG,Yener-Ilce B,Kiliçarslan MA

    更新日期:2020-01-31 00:00:00

  • Effect of surface modification on the photocatalysis of Ti-Ni alloy in orthodontics.

    abstract::Photocatalytic activity from the reaction of titanium oxide with ultraviolet light has recently gained much attention. In particular, there is scientific interest in inducing photocatalytic reactions on Ti-Ni alloy, a material widely used in orthodontic applications. However, it is believed that inducing a photocataly...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.924

    authors: Horiuchi Y,Horiuchi M,Hanawa T,Soma K

    更新日期:2007-11-01 00:00:00

  • Calcium-ion incorporation into titanium surfaces accompanied by electrochemical apatite-deposition.

    abstract::The depths of calcium-ion incorporation into a commercially pure titanium and an experimental beta-type titanium alloy were determined using Auger electron spectroscopy. After the electrochemical deposition of apatite, new compositional gradients appeared in the profiles in which the Ca and P concentrations gradually ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.306

    authors: Ban S,Kamiya A,Sonoda T

    更新日期:2002-12-01 00:00:00

  • A biocompatible model for evaluation of the responses of rat periapical tissue to a new zinc oxide-eugenol sealer.

    abstract::We aimed to establish an experimental animal model to evaluate materials for endodontic therapy. We focused on the biocompatibility of new paste-type zinc oxide-eugenol (ZOE) sealer. The results of this sealer were compared with those of conventional powder/liquid ZOE and eugenol-free sealers. The molars of Wistar rat...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-095

    authors: Mutoh N,Tani-Ishii N

    更新日期:2011-01-01 00:00:00

  • Effects of different luting cements and light curing units on the sealing ability and bond strength of fiber posts.

    abstract::This study evaluated the sealing ability and push-out bond strength of two luting cements cured with two different types of light curing units (LCU): light-emitting diode (LED) versus quartz tungsten halogen (QTH). Forty teeth were divided into four groups(n=10/group). Quartz fiber posts (D. T. Light-Post) were luted ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-209

    authors: Beriat NC,Ertan AA,Yilmaz Z,Gulay G,Sahin C

    更新日期:2012-01-01 00:00:00

  • Micro computed tomography evaluation of the Self-adjusting file and ProTaper Universal system on curved mandibular molars.

    abstract::The aim of this investigation was to compare the cleaning and shaping efficiency of Self-adjusting file and Protaper, and to assess the correlation between root canal curvature and working time in mandibular molars using micro-computed tomography. Twenty extracted mandibular molars instrumented with Protaper and Self-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-255

    authors: Serefoglu B,Piskin B

    更新日期:2017-09-26 00:00:00

  • The application of fluorinated aromatic dimethacrylates to experimental light-cured radiopaque composite resin, containing barium-borosilicate glass filler--a progress in nonwaterdegradable properties.

    abstract::This study investigated the durability, especially the nonwaterdegradable qualities, of experimental light-cured composite resin containing barium-borosilicate glass filler. For this purpose, Bis-GMA, a typical component of base monomer in conventional composite resin, was replaced by Bis-GMA-F which is water-repellen...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.1

    authors: Tanaka J,Inoue K,Masamura H,Matsumura K,Nakai H,Inoue K

    更新日期:1993-06-01 00:00:00

  • Machining accuracy of crowns by CAD/CAM system using TCP/IP: influence of restorative material and scanning condition.

    abstract::The purpose of this study was to determine the optimal condition for fabricating accurate crowns efficiently using an internet-based CAD/CAM system. The influences of three different CAD/CAM restorative materials (titanium, porcelain, and composite resin) and three different step-over scanning distances (0.01 mm, 0.11...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.549

    authors: Tomita S,Shin-ya A,Gomi H,Shin-ya A,Yokoyama D

    更新日期:2007-07-01 00:00:00

  • Surface damages of zirconia by Nd:YAG dental laser irradiation.

    abstract::The purpose of this study was to characterize the surface damages of zirconia by Nd:YAG dental laser irradiation through a systematic evaluation of the associated microstructural changes. Disk specimens of yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) and ceria-stabilized zirconia/alumina nanocomposite (C...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2009-127

    authors: Noda M,Okuda Y,Tsuruki J,Minesaki Y,Takenouchi Y,Ban S

    更新日期:2010-10-01 00:00:00

  • Effects of polishing on surface roughness and hardness of glass-fiber-reinforced polypropylene.

    abstract::Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-012

    authors: Tanimoto Y,Nagakura M

    更新日期:2018-11-30 00:00:00

  • Bioactive-glass in periodontal surgery and implant dentistry.

    abstract::Bioactive-glass (B-G) is a material known for its favorable biological response when in contact with surrounding fibro-osseous tissues, due not only to an osteoconductive property, but also to an osteostimulatory capacity, and superior biocompatibility for use in human body. The objectives of this paper are to review ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-233

    authors: Profeta AC,Prucher GM

    更新日期:2015-01-01 00:00:00

  • Experimental studies on the application of a porcelain-light-cured resin matrix system to the porcelain margin of metal-ceramic crowns.

    abstract::Application of a light-cured porcelain margin is a technique which has been developed recently. In this study, we compared the porcelain margin properties of the porcelain-light-cured resin matrix system and the traditional porcelain-water system, in terms of volumetric shrinkage, density, compressive strength, surfac...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.1

    authors: Lu YS,Yang HW

    更新日期:1995-06-01 00:00:00

  • Effects of thermal cycling and surface roughness on the Weibull distribution of porcelain strength.

    abstract::The objective of this study was to test the hypothesis that thermal cycling weakens the flexural strength of porcelain. Specimens of Deguceram Gold and Vita Omega 900 were tested in four groups of 30 specimens each: in the original glazed condition versus being ground with 1000-grit, 600-grit, and 100-grit silicon car...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.433

    authors: Nakamura Y,Hojo S,Sato H

    更新日期:2009-07-01 00:00:00

  • Effects of potassium and sodium fluoride in different concentrations on micro-shear bond strength and inhibition of demineralization.

    abstract::The aim of this study was to investigate the effects of potassium fluoride (KF) and sodium fluoride (NaF) in different concentrations on micro-shear bond strength (µSBS) and their protective effects against acid. The enamel blocks were treated with several concentrations of KF and NaF. For µSBS, Clearfil SE Bond 2 was...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-019

    authors: Al-Qahtani A,Inoue G,Abdou A,Nikaido T,Tagami J

    更新日期:2020-10-27 00:00:00

  • Effect of storage conditions on mechanical properties of resin composite blanks for CAD/CAM crowns.

    abstract::The objective of this study was to examine the effects of storage conditions on the flexural strengths of resin composite materials for CAD/CAM restorations. Seven commercially available resin composite CAD/CAM blanks were examined. Rectangular specimens (4.0×1.2×4.0 mm) of each material were trimmed from the blanks a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-202

    authors: Hibino Y,Nagasawa Y,Eda Y,Shigeta H,Nakajima H

    更新日期:2020-09-29 00:00:00

  • Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor.

    abstract::The purpose of this study was to evaluate the effect of various incremental filling techniques on adhesion between composite and cavity floor using light-cured resin composite. Black ABS resin and hybrid resin composite were used as mold materials--instead of dentin--for the preparation of cavities, and standardized t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.503

    authors: Chikawa H,Inai N,Cho E,Kishikawa R,Otsuki M,Foxton RM,Tagami J

    更新日期:2006-09-01 00:00:00

  • A review of our development of dental adhesives--effects of radical polymerization initiators and adhesive monomers on adhesion.

    abstract::This paper reviews the development of dental adhesives by collating information of related studies from original scientific papers, reviews, and patent literatures. Through our development, novel radical polymerization initiators, adhesive monomers, and microcapsules were synthesized, and their effects on adhesion wer...

    journal_title:Dental materials journal

    pub_type: 杂志文章,评审

    doi:10.4012/dmj.2009-057

    authors: Ikemura K,Endo T

    更新日期:2010-03-01 00:00:00

  • Microtensile bond strength of a newly developed resin cement to dentin.

    abstract::The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a newly developed resin cement, ECD-89 (ECD, Tokuyama Dental, Tokyo, Japan) to dentin and to observe the interfacial micromorphology by comparing with two commercial resin cements, Multilink Automix (MA, Ivoclar Vivadent AG, Schaan, Lie...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-122

    authors: Kawano S,Fu J,Saikaew P,Chowdhury AA,Fukuzawa N,Kadowaki Y,Kakuda S,Hoshika S,Nakaoki Y,Ikeda T,Tanaka T,Sano H

    更新日期:2015-01-01 00:00:00

  • Diametral tensile strength of novel fast-setting calcium silicate cement.

    abstract::Novel fast-setting calcium silicate cement with fluoride (CSC) has been developed for potential applications in tooth crown. The aim of this study was to test the diametral tensile strength (DTS) of different CSC compositions in humid condition on day1, 28, and 180. We tested 'bond CSC' with 3.5% fluoride and no radio...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-390

    authors: Ranjkesh B,Isidor F,Dalstra M,Løvschall H

    更新日期:2016-01-01 00:00:00

  • Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns.

    abstract::Thermal misfit is deemed as one reason for the chipping of veneered zirconia restorations. Aim of the present study was to assess the effect of thermal misfit on the fracture load of veneered zirconia frameworks and to evaluate the applicability of a universal veneering ceramic for both zirconia and titanium framework...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.766

    authors: Fischer J,Stawarczyk B,Tomic M,Strub JR,Hämmerle CH

    更新日期:2007-11-01 00:00:00

  • Antimicrobial potential of bismuth lipophilic nanoparticles embedded into chitosan-based membrane.

    abstract::The objective of this work was to analyze the antimicrobial and antibiofilm activities of bismuth lipophilic nanoparticles (BisBAL NPs) incorporated into chitosan-based membranes. Chitosan-based membranes were homogeneously embedded with BisBAL NPs, confirming the bismuth presence by scanning electron microscopy. The ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-173

    authors: Martínez-Martínez MA,Hernandez-Delgadillo R,Abada BS,Pineda-Aguilar N,Solís-Soto JM,Nakagoshi-Cepeda MAA,Nakagoshi-Cepeda SE,Chellam S,Sánchez-Nájera RI,Cabral-Romero C

    更新日期:2019-07-31 00:00:00