Effects of different luting cements and light curing units on the sealing ability and bond strength of fiber posts.

Abstract:

:This study evaluated the sealing ability and push-out bond strength of two luting cements cured with two different types of light curing units (LCU): light-emitting diode (LED) versus quartz tungsten halogen (QTH). Forty teeth were divided into four groups(n=10/group). Quartz fiber posts (D. T. Light-Post) were luted to coronal or apical section of root canals using two types of resin cements (Panavia F or RelyX) cured with either LED LCU (Elipar FreeLight II) or QTH LCU (Optilux 501). Highest push-out bond strength was exhibited by QTH-cured RelyX, which was not significantly different from LED-cured RelyX but was higher than QTH-cured Panavia F. The push-out bond strength of Panavia F did not differ with LCU type (p>0.05), but exhibited lower values than both QTH- and LED-cured RelyX. Fluid filtration test revealed that sealing ability was not influenced by luting cement type, but was significantly influenced by LCU type in favor of QTH light source: QTH-cured specimens displayed better seal than LED-cured ones (p<0.05).

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Beriat NC,Ertan AA,Yilmaz Z,Gulay G,Sahin C

doi

10.4012/dmj.2011-209

subject

Has Abstract

pub_date

2012-01-01 00:00:00

pages

575-82

issue

4

eissn

0287-4547

issn

1881-1361

pii

DN/JST.JSTAGE/dmj/2011-209

journal_volume

31

pub_type

杂志文章
  • Structure-property relation of a soft liner material used in denture applications.

    abstract::With a view to understanding the structure-property relation of a silicone-based soft lining denture material after polymerization, its chemical composition and viscoelastic properties were investigated. Chemical compositions of the cured and uncured polymers of a commercial silicone permanent soft liner were determin...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:

    authors: Doğan OM,Keskin S,Doğan A,Ataman H,Usanmaz A

    更新日期:2007-05-01 00:00:00

  • Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys.

    abstract::The effects of dissolved-oxygen concentration and fluoride concentration on the corrosion behaviors of commercial pure titanium, Ti-6Al-4V and Ti-6Al-7Nb alloys and experimentally produced Ti-0.2Pd and Ti-0.5Pt alloys were examined using the corrosion potential measurements. The amount of dissolved Ti was analyzed by ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.83

    authors: Nakagawa M,Matsuya S,Udoh K

    更新日期:2002-06-01 00:00:00

  • Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin.

    abstract::The aim of this study was to investigate in how far the way the specimen is fixed to the testing device influences the micro-tensile bond strength of adhesives to dentin. Compared to a flat jig, a notched jig enables the specimen to be aligned easier and more accurately perpendicular to the interface, thereby concentr...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.694

    authors: Poitevin A,De Munck J,Van Landuyt K,Coutinho E,Peumans M,Lambrechts P,Van Meerbeek B

    更新日期:2007-09-01 00:00:00

  • Response of osteoblast-like cells to zirconia with different surface topography.

    abstract::The objective of this study was to clarify the effect of surface topography on osteoblast-like cell behavior on yttria stabilized tetragonal zirconia polycrystals (TZP). Mirror-polished; blasted with 50- or 150-µm alumina (SB50 and SB150); and SB150 acid-etched with hydrofluoric acid (SB150E) were prepared on TZP. Ini...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-208

    authors: Ito H,Sasaki H,Saito K,Honma S,Yajima Y,Yoshinari M

    更新日期:2013-01-01 00:00:00

  • Impact of different surface treatments and repair material reinforcement on the flexural strength of repaired PMMA denture base material.

    abstract::This study assessed the impact of surface treatments and repair resin reinforcement with zirconium oxide nano-particles (nano-ZrO2) on flexural strength (FS) of repaired denture base. A total of 320 heat-polymerized acrylic resin specimens were prepared and sectioned creating 2-mm gap. According to repair surface trea...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-436

    authors: Gad MM,Rahoma A,Abualsaud R,Al-Thobity AM,Akhtar S,Helal MA,Al-Harbi FA

    更新日期:2020-06-05 00:00:00

  • Diametral tensile strength of novel fast-setting calcium silicate cement.

    abstract::Novel fast-setting calcium silicate cement with fluoride (CSC) has been developed for potential applications in tooth crown. The aim of this study was to test the diametral tensile strength (DTS) of different CSC compositions in humid condition on day1, 28, and 180. We tested 'bond CSC' with 3.5% fluoride and no radio...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-390

    authors: Ranjkesh B,Isidor F,Dalstra M,Løvschall H

    更新日期:2016-01-01 00:00:00

  • Effectiveness of bonding resin-based composite to healthy and fluorotic enamel using total-etch and two self-etch adhesive systems.

    abstract::The aim of this study was to evaluate the bond strength of three adhesive systems: Excite™, Adper Prompt L-Pop™ and AdheSE One™ to varying degrees of fluorotic enamel using micro-tensile bond strength (μTBS) tests. Human enamel was classified according to the Thylstrup and Fejerskov Index. The interface resin-enamel w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-140

    authors: Torres-Gallegos I,A Martinez-Castañon G,Loyola-Rodriguez JP,Patiño-Marin N,Encinas A,Ruiz F,Anusavice K

    更新日期:2012-01-01 00:00:00

  • Evaluation of an articulated measuring apparatus for use in the oral cavity.

    abstract::The aim of this study was to evaluate the trial Teaching Robot for the development of a contact-type measuring apparatus for using directly in the oral cavity. A standard model was used to mimic the dentition by placing an arrangement of three bearing balls. The diameters of the balls were measured. A practical dentit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.168

    authors: Maikuma Y,Usui K,Araki K,Mataki S,Kurosaki N,Furuya N

    更新日期:2003-06-01 00:00:00

  • Influences of filler content and size on the color adjustment potential of nonlayered resin composites.

    abstract::The blending effect (BE) plays an important role in esthetics of the composite resin. The objective of this study was to determine the extents to which filler size and content affect the BE. Three types of fillers (0.7, 1.0, and 1.5 µm) were mixed at weight contents of 60, 70, 75, and 80%. This study simulated clinica...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-083

    authors: Suh YR,Ahn JS,Ju SW,Kim KM

    更新日期:2017-01-31 00:00:00

  • Surface damages of zirconia by Nd:YAG dental laser irradiation.

    abstract::The purpose of this study was to characterize the surface damages of zirconia by Nd:YAG dental laser irradiation through a systematic evaluation of the associated microstructural changes. Disk specimens of yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) and ceria-stabilized zirconia/alumina nanocomposite (C...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2009-127

    authors: Noda M,Okuda Y,Tsuruki J,Minesaki Y,Takenouchi Y,Ban S

    更新日期:2010-10-01 00:00:00

  • Effects of thermal cycling and surface roughness on the Weibull distribution of porcelain strength.

    abstract::The objective of this study was to test the hypothesis that thermal cycling weakens the flexural strength of porcelain. Specimens of Deguceram Gold and Vita Omega 900 were tested in four groups of 30 specimens each: in the original glazed condition versus being ground with 1000-grit, 600-grit, and 100-grit silicon car...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.433

    authors: Nakamura Y,Hojo S,Sato H

    更新日期:2009-07-01 00:00:00

  • Initial and long-term bond strengths of one-step self-etch adhesives with silane coupling agent to enamel-dentin-composite in combined situation.

    abstract::This study evaluated the effect of adding silane coupling agent on initial and long-term bond strengths of one-step self-etch adhesives to enamel-dentin-composite in combined situation. Cervical cavities were prepared on extracted molars and filled with Clearfil AP-X. After water-storage for one-week, the filled teeth...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-050

    authors: Mamanee T,Takahashi M,Nakajima M,Foxton RM,Tagami J

    更新日期:2015-01-01 00:00:00

  • Improving biocompatibility of zirconia surface by incorporating Ca ions.

    abstract::Though zirconia has been used in dental implant fixtures, the biocompatibility of the zirconia surface is not optimal for the surrounding tissue, and many surface modifications have been attempted. We have developed a novel method for improving the biocompatibility of zirconia by incorporating Ca ions. Elemental analy...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-199

    authors: Sasaki K,Hayashi T,Asakura M,Ando M,Kawai T,Ban S

    更新日期:2015-01-01 00:00:00

  • The hydration chemistry of ProRoot MTA.

    abstract::'Tooth-coloured' ProRoot MTA is an endodontic cement comprising an 80:20 wt% mixture of white Portland cement (WPC) and bismuth oxide. The setting reactions within this cement system are not currently well understood. Accordingly, this research monitors the early hydration chemistry of ProRoot MTA by X-ray diffraction...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-309

    authors: Li Q,Coleman NJ

    更新日期:2015-01-01 00:00:00

  • Effects of CO2 laser irradiation combined with fluoride application on the demineralization, mechanical properties, structure, and composition of enamel.

    abstract::We investigated the effects of CO2 laser irradiation combined with acidulated phosphate fluoride (APF) application on the demineralization of enamel. APF gel was applied to the buccal enamel of human premolars and CO2 laser was applied. After the specimens were immersed in demineralization solution for 72 h, they were...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-225

    authors: Nakagaki S,Iijima M,Endo K,Saito T,Mizoguchi I

    更新日期:2015-01-01 00:00:00

  • The thickness effects of titanium castings on the surface reaction layer.

    abstract::In this study, wedge-shaped CP titanium castings and Ti-6Al-7Nb alloy castings were produced by three types of investment. The effects of the castings' thickness on surface reaction layer were investigated by measuring Vickers hardness, observing the microstructure, and analyzing the oxygen concentration. It was found...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.387

    authors: Kikuchi H,Onouchi M,Miyanaga K,Wakashima M,Okuno O,Nishiyama M

    更新日期:2004-09-01 00:00:00

  • In vivo effect of fluoride-substituted apatite on rat bone.

    abstract::Different types of calcium phosphate compounds are commercially available for medical and dental applications as bone substitute materials. Biological apatites contain several kinds of minor elements such as carbonate (CO3), magnesium (Mg), and fluoride (F) in enamel, dentin, and bone. It has been shown that F ion and...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.398

    authors: Inoue M,Nagatsuka H,Tsujigiwa H,Inoue M,LeGeros RZ,Yamamoto T,Nagai N

    更新日期:2005-09-01 00:00:00

  • Analysis of abutment tooth movement utilizing mandibular kinesiography (MKG). Part 2. Effects of clasp design in unilateral free-end denture.

    abstract::The three-dimensional dynamic movement of the abutment tooth was successfully analyzed on a simulation model utilizing the mandibular kinesiography. When the unilateral free-end denture retained by the RPA, RPI or Aker's clasp was subjected to various directions of loads, the abutment tooth was inclined mainly by the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.56

    authors: Morikawa M,Masumi S,Kido H,Toyoda S,Kozono Y

    更新日期:1989-06-01 00:00:00

  • Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.

    abstract::The corrosion behavior of three Ni-Ti alloys with compositions as commercial super-elastic orthodontic wires was investigated using polished plate specimens. Corrosion resistance was estimated by potentiodynamic polarization measurement in 0.9% NaCl and 1% lactic acid solutions and analysis of released metals by atomi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.31

    authors: Iijima M,Endo K,Ohno H,Mizoguchi I

    更新日期:1998-03-01 00:00:00

  • Determination of molecular species of calcium salts of MDP produced through decalcification of enamel and dentin by MDP-based one-step adhesive.

    abstract::Enamel and dentin particles were added to an experimental 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based one-step adhesive to react for 30 s. After enamel and dentin reactants were analyzed using X-ray diffraction (XRD) and phosphorus-31 nuclear magnetic resonance ((31)P NMR) techniques, curve-fitting analys...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-260

    authors: Yokota Y,Nishiyama N

    更新日期:2015-01-01 00:00:00

  • Cytotoxicity evaluation of luting resin cements on bovine dental pulp-derived cells (bDPCs) by real-time cell analysis.

    abstract::To evaluate the cytotoxicity of resin cements on dental pulp-derived cells (bDPCs), Bifix QM (BQM), Choice 2(C2), RelyX U200(RU200), Maxcem Elite(ME), and Multilink Automix(MA) were tested. The materials were incubated in DMEM for 72 h. A real-time cell analyzer was used to evaluate cell survival. The statistical anal...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-167

    authors: Arslan Malkoç M,Demir N,Şengün A,Bozkurt ŞB,Hakki SS

    更新日期:2015-01-01 00:00:00

  • Type I collagen grafting on titanium surfaces using low-temperature glow discharge.

    abstract::To improve the bioactivity of titanium surfaces, glow discharge was used to facilitate collagen grafting on titanium disks. Titanium test specimens were pre-treated by glow discharge fed with a mixture of argon and allylamine (AA) gases. Treated titanium disks were then grafted with type I collagen using glutaraldehyd...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.340

    authors: Chang WJ,Ou KL,Lee SY,Chen JY,Abiko Y,Lin CT,Huang HM

    更新日期:2008-05-01 00:00:00

  • Diffusion of GM primer and dentin adhesive into EDTA-conditioned dentin.

    abstract::The aim of this study was to investigate the diffusion of red-stained experimental GM primer and blue-stained dentin bonding agent into EDTA-conditioned dentin and the effect of GM priming on contraction gap formation. After GM priming at 0, 35, 70, or 100 vol%, marginal adaptation was evaluated by measuring the wall-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2009-084

    authors: Nasu Y,Itoh K,Tani C,Hisamitsu H

    更新日期:2010-10-01 00:00:00

  • Development of casting investment preventing blackening of noble metal alloys part 1. Application of developed investment for Ag-Pd-Cu-Au alloy.

    abstract::The objective of this study is to develop a casting investment that prevents the blackening of the cast surface of noble metal alloys. The experimental investments were prepared using a gypsum-bonded investment in which the metallic powders such as boron (B), silicon (Si), aluminum (Al) and titanium (Ti) were added as...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.87

    authors: Kakuta K,Nakai A,Goto S,Wakamatsu Y,Yara A,Miyagawa Y,Ogura H

    更新日期:2003-03-01 00:00:00

  • Immobilization of octadecyl ammonium chloride on the surface of titanium and its effect on microbial colonization in vitro.

    abstract::The aim of our study was twofold: to immobilize an organosilicon quaternary ammonium salt (3-(trimethoxysilyl)-propyldimethyl-octadecyl ammonium chloride, Si-QAC) on the surface of pure titanium and to investigate the antimicrobial activity of Si-QAC-immobilized titanium against microbial adherence and biofilm formati...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.570

    authors: Nikawa H,Ishida K,Hamada T,Satoda T,Murayama T,Takemoto T,Tamamoto M,Tajima H,Shimoe S,Fujimoto H,Makihira S

    更新日期:2005-12-01 00:00:00

  • Cold plasma-induced surface modification of heat-polymerized acrylic resin and prevention of early adherence of Candida albicans.

    abstract::Atmospheric-pressure cold plasma was applied to process the surface of heat-polymerized acrylic resin. Changes to the physical properties and early adherence of Candida albicans were investigated. Alternating current cold plasma with Ar/O2 as working gas was used. Scanning electron microscopy (SEM) and X-ray photoelec...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-035

    authors: Pan H,Wang G,Pan J,Ye G,Sun K,Zhang J,Wang J

    更新日期:2015-01-01 00:00:00

  • Wear resistance of hybrid composite resin for crown material by the two-body sliding test.

    abstract::Comparative studies on two-body sliding wear resistance were performed between a hybrid composite resin and conventional light-curing composite veneering materials. This study investigated the wear resistance of hybrid composite resins compared with three composite resin veneering materials for 12%Au-Ag-Pd alloy, the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.225

    authors: Suese K,Kawazoe T

    更新日期:2002-09-01 00:00:00

  • The application of fluorinated aromatic dimethacrylates to experimental light-cured radiopaque composite resin, containing barium-borosilicate glass filler--a progress in nonwaterdegradable properties.

    abstract::This study investigated the durability, especially the nonwaterdegradable qualities, of experimental light-cured composite resin containing barium-borosilicate glass filler. For this purpose, Bis-GMA, a typical component of base monomer in conventional composite resin, was replaced by Bis-GMA-F which is water-repellen...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.1

    authors: Tanaka J,Inoue K,Masamura H,Matsumura K,Nakai H,Inoue K

    更新日期:1993-06-01 00:00:00

  • Genetic potential of interfacial guided osteogenesis in implant devices.

    abstract::The purpose of this review is to summarise recent advances in the design and composition of bioactive surface layers of implantabile biomaterials, and thus the genetic potential of osteoprogenitor cells to recognize and respond to these diverse implanted biomaterials. Changes applied to a biomaterial's surface, in gen...

    journal_title:Dental materials journal

    pub_type: 杂志文章,评审

    doi:10.4012/dmj.19.99

    authors: Letić-Gavrilović A,Scandurra R,Abe K

    更新日期:2000-06-01 00:00:00

  • Permeability of etching agent constituents through dentin.

    abstract::The in vitro dentin permeability of the constituents of two types of conventional phosphoric acid etching agents which had different viscosities, and their pH changes after being permeated dentin were investigated. It was recognized that, even though the etching was for a short time (one minute) followed by rinsing, t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.164

    authors: Ishikawa K,Ito S,Hata Y

    更新日期:1989-12-01 00:00:00