Immobilization of octadecyl ammonium chloride on the surface of titanium and its effect on microbial colonization in vitro.

Abstract:

:The aim of our study was twofold: to immobilize an organosilicon quaternary ammonium salt (3-(trimethoxysilyl)-propyldimethyl-octadecyl ammonium chloride, Si-QAC) on the surface of pure titanium and to investigate the antimicrobial activity of Si-QAC-immobilized titanium against microbial adherence and biofilm formation. The results of ToF-SIMS analysis of Si-QAC-titanium suggested the possibility of immobilizing Si-QAC on titanium surface through Ti-O-Si coupling, and that Si-QAC treatment significantly reduced both the adherence and colonization of Candida albicans and Streptococcus mutans isolates. The antimicrobial activity was achieved through at least two mechanisms: the first was attributed to the octadecyl alkyl chain which inhibited initial adherence, and the second was attributed to the quaternary ammonium salt which killed initial adherent cells as well as retarded or inhibited subsequent microbial growth. Further, thermocycling did not significantly reduce the antimicrobial activity of Si-QAC-titanium, and no significant cytotoxicity of Si-QAC-titanium was observed in either cell viability test or proinflammatory cytokine production test using human gingival fibroblasts. These results, taken together, favorably suggested that Si-QAC treatment would be a helpful means to inhibit dental plaque or denture plaque formation.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Nikawa H,Ishida K,Hamada T,Satoda T,Murayama T,Takemoto T,Tamamoto M,Tajima H,Shimoe S,Fujimoto H,Makihira S

doi

10.4012/dmj.24.570

keywords:

subject

Has Abstract

pub_date

2005-12-01 00:00:00

pages

570-82

issue

4

eissn

0287-4547

issn

1881-1361

journal_volume

24

pub_type

杂志文章
  • Wear resistance of hybrid composite resin for crown material by the two-body sliding test.

    abstract::Comparative studies on two-body sliding wear resistance were performed between a hybrid composite resin and conventional light-curing composite veneering materials. This study investigated the wear resistance of hybrid composite resins compared with three composite resin veneering materials for 12%Au-Ag-Pd alloy, the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.225

    authors: Suese K,Kawazoe T

    更新日期:2002-09-01 00:00:00

  • Transformation behavior of nickel-titanium orthodontic wires under tensile load.

    abstract::This study investigated transformations of nickel-titanium wires using differential scanning calorimetry (DSC) and thermomechanical analysis (TMA) under tensile load (100 gf or 500 gf). Two nickel-titanium wires, 35°C Copper Ni-Ti and Nitinol SE, were selected. DSC analyses were performed between -90° and 100°C. Speci...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-196

    authors: Iijima M,Ohta M,Brantley WA,Naganishi A,Murakami T,Muguruma T,Mizoguchi I

    更新日期:2011-01-01 00:00:00

  • Investigation of the correlation between the different mechanical properties of resin composites.

    abstract::The aim of this study was to investigate the relationship between the different mechanical properties with the filler fraction of various resin composites. Mechanical properties of eighteen different resin composites were investigated in this study; flexural strength (FS), flexural modulus (FM), fracture toughness (FT...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-178

    authors: Jun SK,Kim DA,Goo HJ,Lee HH

    更新日期:2013-01-01 00:00:00

  • Measurement of exothermic heat released during polymerization of a lightcuring composite resin: Comparison of light irradiation modes.

    abstract::High-power light-curing units have emerged that reduce the time of procedures in dental clinical work. However, patients sometimes complain of pain during the polymerization of composite resin. In this experiment, we investigated how differences in light-curing mode affect the temperature rise during composite resin p...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-158

    authors: Hori M,Fujimoto K,Asakura M,Nagase Y,Mieki A,Kawai T

    更新日期:2019-07-31 00:00:00

  • Morphological and chemical analysis of different precipitates on mineral trioxide aggregate immersed in different fluids.

    abstract::The purpose of this study was to analyze the ultrastructures and chemical compositions of precipitates formed on mineral trioxide aggregate (MTA; White ProRoot MTA) immersed in distilled water (DW) or phosphate buffered saline (PBS), based on the attribution that MTA's bioactivity and sealing ability are influenced by...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2009-133

    authors: Han L,Okiji T,Okawa S

    更新日期:2010-10-01 00:00:00

  • A study of self-adhesive resin cements for bonding to silver-palladium-copper-gold alloy -- effect of including primer components in cement base.

    abstract::This study investigated the efficacies of adhesive resin cements (Clearfil SA Luting, Maxcem, G-CEM, RelyX Unicem Clicker, Vitremer Paste) for bonding to Ag-Pd-Cu-Au alloy not surface-pretreated with metal primer. For control, Panavia F 2.0 -developed for use with a proprietary metal primer, Alloy Primer- was tested w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-093

    authors: Muraguchi K,Minami H,Minesaki Y,Suzuki S,Tanaka T

    更新日期:2011-01-01 00:00:00

  • Measurement of surface hardness of primary carious lesions in extracted human enamel -measurement of Knoop hardness using Cariotester.

    abstract::The clinical feasibility of a novel device called a Cariotester was investigated by measuring the Knoop hardness (KHN) of white spot lesions diagnosed as ICDAS code 1, 2 or 3. To obtain an equation for converting the Cariotester indentation depth into the KHN, a regression analysis was performed between the depth and ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-282

    authors: Shimizu A,Yamamoto T,Nakashima S,Nikaido T,Sugawara T,Momoi Y

    更新日期:2015-01-01 00:00:00

  • Relation between attractive force and keeper surface characteristics of iron-neodymium-boron magnetic attachment systems.

    abstract::The purpose of this study was to evaluate the influence of heating, cast bonding, and subsequent polishing procedures on attractive force of magnetic attachments. Two magnetic attachment systems with keepers of different chemical compositions (Hicorexslim 3013, 447J1; Magfit EX400, AUM20) were employed. Keepers examin...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.393

    authors: Ohashi N,Koizumi H,Ishikawa Y,Furuchi M,Matsumura H,Tanoue N

    更新日期:2007-05-01 00:00:00

  • Chemical mechanical polishing of titanium with colloidal silica containing hydrogen peroxide--mirror polishing and surface properties.

    abstract::Chemical mechanical polishing (CMP) of cpTi (Ti) was carried out using two types of slurries, acidic and basic colloidal silica containing H2O2 up to 3 wt%, to obtain flat and mirror-polished surfaces without any contaminated and reacted layers. Polishing behavior and surface properties were investigated using AFM, EP...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.68

    authors: Okawa S,Watanabe K

    更新日期:2009-01-01 00:00:00

  • In vitro study of anti-suck-back ability by themselves on new high-speed air turbine handpieces.

    abstract::The anti-suck-back ability of five new high-speed air turbine handpiece models was evaluated in this study. First, suck-back pressure with water displacement within a glass tube was measured. Next, under three different conditions, how many on-off times it takes before fluorescent stains became visible on a piece of g...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-008

    authors: Ozawa T,Nakano M,Arai T

    更新日期:2010-11-01 00:00:00

  • Fluorescence of thulium-doped translucent zirconia.

    abstract::The fluorescence and physical properties of thulium-doped zirconia were investigated. A standard grade of zirconia (TZ-3Y-E) and two translucent dental zirconia materials (Zpex and Zpex Smile) were examined. The specimens were prepared by addition of 0-1.5 wt% Tm2O3 and then sintering. When exposed to UV light, the Tm...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-384

    authors: Nakamura T,Okamura S,Nishida H,Usami H,Nakano Y,Wakabayashi K,Sekino T,Yatani H

    更新日期:2018-11-30 00:00:00

  • Novel self-etching and antibacterial orthodontic adhesive containing dimethylaminohexadecyl methacrylate to inhibit enamel demineralization.

    abstract::Enamel demineralization is one of the most undesired side effects of fixed orthodontic treatment, which will lead to white spot lesions (WSLs) on tooth surfaces. The development of WSLs is due to prolonged accumulation of bacterial plaque and associated acid production. Self-etching adhesives have been used in orthodo...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-286

    authors: Wang X,Zhang N,Wang B,Park SR,Weir MD,Xu HHK,Bai Y

    更新日期:2018-07-29 00:00:00

  • In vitro comparison of autoclave polymerization on the transverse strength of denture base resins.

    abstract::The aim of this study was to determine the effect of autoclave polymerization on the transverse strength of denture base polymers. To this end, 30 rectangular test specimens were fabricated of two heat-polymerized denture base polymers. The test groups were: (I) control, i.e., conventional water bath to polymerize res...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:

    authors: Durkan R,Ozel MB,Bağiş B,Usanmaz A

    更新日期:2008-07-01 00:00:00

  • A biocompatible model for evaluation of the responses of rat periapical tissue to a new zinc oxide-eugenol sealer.

    abstract::We aimed to establish an experimental animal model to evaluate materials for endodontic therapy. We focused on the biocompatibility of new paste-type zinc oxide-eugenol (ZOE) sealer. The results of this sealer were compared with those of conventional powder/liquid ZOE and eugenol-free sealers. The molars of Wistar rat...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-095

    authors: Mutoh N,Tani-Ishii N

    更新日期:2011-01-01 00:00:00

  • Antibacterial activity of composite resin with glass-ionomer filler particles.

    abstract::The purpose of this study was to examine the antibacterial activity of composite resin with glass-ionomer filler particles versus that of contemporary commercial composite resins. Three composite resins were used: Beautifil II (containing S-PRG filler), Clearfil AP-X, and Filtek Z250. Resin blocks were bonded to maxil...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2009-050

    authors: Saku S,Kotake H,Scougall-Vilchis RJ,Ohashi S,Hotta M,Horiuchi S,Hamada K,Asaoka K,Tanaka E,Yamamoto K

    更新日期:2010-03-01 00:00:00

  • The influence of storing alginate impressions sprayed with disinfectant on dimensional accuracy and deformation of maxillary edentulous stone models.

    abstract::This study investigated the effects of storing impressions for 3 hours after spraying them with a disinfectant solution on dimensional change and deformation of maxillary edentulous stone models. Three brands of alginate impression materials, characterized by a small degree of contraction in 100% relative humidity, we...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2009-083

    authors: Hiraguchi H,Kaketani M,Hirose H,Yoneyama T

    更新日期:2010-05-01 00:00:00

  • Effect of surface preparation on the bond strength of heat-polymerized denture base resin to commercially pure titanium and cobalt-chromium alloy.

    abstract::The aim of this study was to investigate the bond durability of heat-polymerized denture base resin to cast CP Ti and Co-Cr alloy. The alloy specimens were divided into five groups: 1) airborne-particle abraded with 50 µm alumina (SAND), 2) Rocatec tribochemical silica coating system (RO), 3) air-abraded followed by a...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2010-089

    authors: Kawaguchi T,Shimizu H,Lassila LV,Vallittu PK,Takahashi Y

    更新日期:2011-01-01 00:00:00

  • Influence of a denture strengthener on the deformation of a maxillary complete denture.

    abstract::The present study investigated the influences of a denture strengthener on the deformation of a maxillary complete denture. Three groups of maxillary complete dentures were fabricated (Group 1 without a strengthener; Group 2 with a Co-Cr alloy wire strengthener; Group 3 with an experimental fiberglass strengthener). T...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.507

    authors: Hirajima Y,Takahashi H,Minakuchi S

    更新日期:2009-07-01 00:00:00

  • Evaluation of temperature changes in the pulp chamber during polymerization of light-cured pulp-capping materials by using a VALO LED light curing unit at different curing distances.

    abstract::The aim of this study was to evaluate temperature changes in the pulp chamber during polymerization of four different pulp-capping materials using a LED-light-curing-unit in the contact and noncontact positions. A pulpal circulation mechanism was simulated to measure increases in temperature in four pulp-capping mater...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-274

    authors: Savas S,Botsali MS,Kucukyilmaz E,Sari T

    更新日期:2014-01-01 00:00:00

  • Surface damages of zirconia by Nd:YAG dental laser irradiation.

    abstract::The purpose of this study was to characterize the surface damages of zirconia by Nd:YAG dental laser irradiation through a systematic evaluation of the associated microstructural changes. Disk specimens of yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) and ceria-stabilized zirconia/alumina nanocomposite (C...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2009-127

    authors: Noda M,Okuda Y,Tsuruki J,Minesaki Y,Takenouchi Y,Ban S

    更新日期:2010-10-01 00:00:00

  • A review of our development of dental adhesives--effects of radical polymerization initiators and adhesive monomers on adhesion.

    abstract::This paper reviews the development of dental adhesives by collating information of related studies from original scientific papers, reviews, and patent literatures. Through our development, novel radical polymerization initiators, adhesive monomers, and microcapsules were synthesized, and their effects on adhesion wer...

    journal_title:Dental materials journal

    pub_type: 杂志文章,评审

    doi:10.4012/dmj.2009-057

    authors: Ikemura K,Endo T

    更新日期:2010-03-01 00:00:00

  • Evaluation of the responses of MHC class II molecule-expressing cells and macrophages to epoxy resin-based and 4-META-containing, methacrylate resin-based root canal sealers in rat subcutaneous tissue.

    abstract::Major histocompatibility complex (MHC) class II molecule-expressing cells and macrophages play a pivotal role in mediating the host tissue response to biomaterials. This study investigated the responses of these cells to epoxy resin-based and 4-META-containing, methacrylate resin-based endodontic sealers (AH Plus and ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-005

    authors: Yamanaka Y,Shigetani Y,Yoshiba K,Kaneko T,Yoshiba N,Okiji T

    更新日期:2013-01-01 00:00:00

  • Effect of different remaining dentin thickness and long term water storage on dentin bond strength.

    abstract::The purpose of this study was to investigate the effect of remaining dentin thickness (RDT) and long term water storage on dentin bond strength in-vitro. Twenty-seven third molars were randomly divided into 3 groups: Clearfil Bond SE ONE (SE1, Kuraray Noritake Dental, Okayama, Japan), G-Bond plus (GB, GC, Tokyo, Japan...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-140

    authors: Ting S,Chowdhury AFMA,Sun J,Kakuda S,Sidhu SK,Yoshida Y,Selimovic D,Sano H

    更新日期:2018-07-29 00:00:00

  • Flexural properties of three kinds of experimental fiber-reinforced composite posts.

    abstract::The aim of this study was to estimate the flexural properties of three kinds of experimental fiber-reinforced composite (FRC) posts and to evaluate their potential use as posts. Experimental FRC posts were fabricated with glass, aramid, and UHMWP fibers. Commercial FRC posts were used for comparison. A three-point ben...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-053

    authors: Kim MJ,Jung WC,Oh S,Hattori M,Yoshinari M,Kawada E,Oda Y,Bae JM

    更新日期:2011-01-01 00:00:00

  • A simplified numerical simulation method of bending properties for glass fiber cloth reinforced denture base resin.

    abstract::The purpose of this study was to propose a new numerical modeling of the glass fiber cloth reinforced denture base resin (GFRP). The proposed model is constructed with an isotropic shell, beam and orthotropic shell elements representing the outmost resin, interlaminar resin and glass fiber cloth, respectively. The pro...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.105

    authors: Tanimoto Y,Nishiwaki T,Nishiyama N,Nemoto K,Maekawa Z

    更新日期:2002-06-01 00:00:00

  • Effect of surface modification on the photocatalysis of Ti-Ni alloy in orthodontics.

    abstract::Photocatalytic activity from the reaction of titanium oxide with ultraviolet light has recently gained much attention. In particular, there is scientific interest in inducing photocatalytic reactions on Ti-Ni alloy, a material widely used in orthodontic applications. However, it is believed that inducing a photocataly...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.924

    authors: Horiuchi Y,Horiuchi M,Hanawa T,Soma K

    更新日期:2007-11-01 00:00:00

  • Modification of electrochemically deposited apatite using supercritical water.

    abstract::Supercritical water was used as a modification method of electrochemically deposited apatite on pure titanium. The apatites were coated on a commercially pure titanium plate using a hydrothermal-electrochemical method. A constant direct current at 12.5 mA/cm2 was loaded for 1 hr at 25, 60, 100, 150 and 200 degrees C i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.247

    authors: Ban S,Hasegawa J

    更新日期:2001-12-01 00:00:00

  • Novel, multi-purpose, PMMA-type adhesive resin with newly synthesized microcapsule of radical polymerization initiators.

    abstract::The behavior of microencapsulated polymerization initiators in dental adhesives is unknown. This study investigated the effects of new microencapsulated initiators in novel, multi-purpose, PMMA-type adhesive resin on the bonding performance and polymerization reactivity. Microencapsulated BPO and 1,3,5-trimethylbarbit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.35

    authors: Fuchigami K,Ikemura K,Ichizawa K

    更新日期:2008-01-01 00:00:00

  • Predicting in vivo failure of rotary nickel-titanium endodontic instruments under cyclic fatigue.

    abstract::The aim of this study was to examine the lifespan or number of cycles to failure of tapered rotary nickel-titanium (Ni-Ti) endodontic instruments. Simulated root canals with different curvatures were used to determine a relation between canal curvature and instrument lifespan. Using a novel mathematical model for the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-254

    authors: Stojanac I,Drobac M,Petrovic L,Atanackovic T

    更新日期:2012-01-01 00:00:00

  • Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin.

    abstract::The aim of this study was to investigate in how far the way the specimen is fixed to the testing device influences the micro-tensile bond strength of adhesives to dentin. Compared to a flat jig, a notched jig enables the specimen to be aligned easier and more accurately perpendicular to the interface, thereby concentr...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.694

    authors: Poitevin A,De Munck J,Van Landuyt K,Coutinho E,Peumans M,Lambrechts P,Van Meerbeek B

    更新日期:2007-09-01 00:00:00