Chemical mechanical polishing of titanium with colloidal silica containing hydrogen peroxide--mirror polishing and surface properties.

Abstract:

:Chemical mechanical polishing (CMP) of cpTi (Ti) was carried out using two types of slurries, acidic and basic colloidal silica containing H2O2 up to 3 wt%, to obtain flat and mirror-polished surfaces without any contaminated and reacted layers. Polishing behavior and surface properties were investigated using AFM, EPMA, and XPS. Weight loss of Ti polished by CMP using the basic slurry was larger than that using the acidic one, and surface roughness was less than 2 nm RMS when basic slurry containing 3 wt% H2O2 was used. Moreover, three kinds of chemical species, OH-, O2-, and H2O, were detected on the Ti surfaces polished by CMP using these slurries. Results of this study showed that CMP using colloidal silica containing H2O2 successfully created a mirror-polished surface without contaminated and reacted layers.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Okawa S,Watanabe K

doi

10.4012/dmj.28.68

subject

Has Abstract

pub_date

2009-01-01 00:00:00

pages

68-74

issue

1

eissn

0287-4547

issn

1881-1361

journal_volume

28

pub_type

杂志文章
  • Polymerization shrinkage, flexural and compression properties of low-shrinkage dental resin composites.

    abstract::This study evaluated the polymerization shrinkage, flexural and compressive properties of low-shrinkage resin composites. For the study, four methacrylate-based and one silorane-based resin composites were light cured using three different light-curing units (LCUs) and their polymerization shrinkage, flexural (strengt...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-126

    authors: Park JK,Lee GH,Kim JH,Park MG,Ko CC,Kim HI,Kwon YH

    更新日期:2014-01-01 00:00:00

  • Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns.

    abstract::Thermal misfit is deemed as one reason for the chipping of veneered zirconia restorations. Aim of the present study was to assess the effect of thermal misfit on the fracture load of veneered zirconia frameworks and to evaluate the applicability of a universal veneering ceramic for both zirconia and titanium framework...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.766

    authors: Fischer J,Stawarczyk B,Tomic M,Strub JR,Hämmerle CH

    更新日期:2007-11-01 00:00:00

  • Influences of filler content and size on the color adjustment potential of nonlayered resin composites.

    abstract::The blending effect (BE) plays an important role in esthetics of the composite resin. The objective of this study was to determine the extents to which filler size and content affect the BE. Three types of fillers (0.7, 1.0, and 1.5 µm) were mixed at weight contents of 60, 70, 75, and 80%. This study simulated clinica...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-083

    authors: Suh YR,Ahn JS,Ju SW,Kim KM

    更新日期:2017-01-31 00:00:00

  • Discoloration of manually fabricated resins and industrially fabricated CAD/CAM blocks versus glass-ceramic: effect of storage media, duration, and subsequent polishing.

    abstract::This study determined the discoloration of five CAD/CAM resins, four manually polymerized resins, and glass-ceramic as control group. Specimens were divided into three groups (N=300, n=30) to be stored in coffee, black tea and red wine (n=10). The discoloration was measured using a spectrophotometer after 1, 7, 29, 90...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-238

    authors: Stawarczyk B,Sener B,Trottmann A,Roos M,Ozcan M,Hämmerle CH

    更新日期:2012-01-01 00:00:00

  • Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor.

    abstract::The purpose of this study was to evaluate the effect of various incremental filling techniques on adhesion between composite and cavity floor using light-cured resin composite. Black ABS resin and hybrid resin composite were used as mold materials--instead of dentin--for the preparation of cavities, and standardized t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.503

    authors: Chikawa H,Inai N,Cho E,Kishikawa R,Otsuki M,Foxton RM,Tagami J

    更新日期:2006-09-01 00:00:00

  • Multi-purpose bonding performance of newly synthesized phosphonic acid monomers.

    abstract::Multi-purpose bonding performance of three kinds of newly synthesized phosphonic acid monomers was investigated. Methacryloxyalkyl or acryloxyalkyl phosphonoacetates of 6-MHPA, 6-AHPA, 10-MDPA were synthesized in 42.8-51.9% yields with a light yellow viscous liquid, and identified as new compounds by 1H NMR, IR, and e...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.105

    authors: Ikemura K,Tay FR,Nishiyama N,Pashley DH,Endo T

    更新日期:2007-01-01 00:00:00

  • Flexural properties of resin-modified "hybrid" glass-ionomers in comparison with conventional acid-base glass-ionomers.

    abstract::The mechanical properties of resin-modified "hybrid" glass-ionomers, for both restorative and liner/base applications, were assessed by a flexural test and compared with those of conventional acid-base glass-ionomers. Flexural strength, flexural modulus, and the modulus of resilience were determined 30 minutes after m...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.109

    authors: Momoi Y,Hirosaki K,Kohno A,McCabe JF

    更新日期:1995-12-01 00:00:00

  • Cytotoxic effects of contemporary bulk-fill dental composites: A real-time cell analysis.

    abstract::The aim of this study was to evaluate the cytotoxicity of contemporary flowable and paste-like bulk-fill dental composites by using a real-time cell analysis. In the present paper, cytotoxicity levels of five flowable, five paste-like bulk-fill composite materials and one conventional flowable, one conventional paste-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-336

    authors: Demirel G,Gür G,Demirsoy FF,Altuntaş EG,Yener-Ilce B,Kiliçarslan MA

    更新日期:2020-01-31 00:00:00

  • The application of cellulose acetate replication sheets in enamel wear investigations.

    abstract::Surface replication is a nondestructive evaluation technique applied in examining surfaces' cracks/wear. This is quite valuable when the surface of interest cannot be further manipulated by cutting or polishing to fit directly under a microscope. Replication by acetate sheets is one of the techniques applied in indust...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-444

    authors: Ijbara M,Wada K,Wada J,Jayawardena JA,Miyashin M

    更新日期:2019-02-08 00:00:00

  • Influence of a propolis-based irrigant solution on gap formation and bond strength of posts bonded to root canal dentin using different resin cements.

    abstract::This study evaluated the influence of an aqueous propolis-based solution (PROP) on gap formation and bond strength of posts bonded to root canal dentin using resin cements. Endodontically-treated bovine incisors received different irrigation protocols: 1) 2.5% sodium hypochlorite (NaOCl)/17% EDTA/NaOCl; 2) saline solu...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-111

    authors: Matochek MHM,Tomaz PLS,Oliveira TS,Polassi MR,Alonso RCB,Scremin FM,Sauro S,Marcucci MC,D'Alpino PHP

    更新日期:2020-06-05 00:00:00

  • Type I collagen grafting on titanium surfaces using low-temperature glow discharge.

    abstract::To improve the bioactivity of titanium surfaces, glow discharge was used to facilitate collagen grafting on titanium disks. Titanium test specimens were pre-treated by glow discharge fed with a mixture of argon and allylamine (AA) gases. Treated titanium disks were then grafted with type I collagen using glutaraldehyd...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.340

    authors: Chang WJ,Ou KL,Lee SY,Chen JY,Abiko Y,Lin CT,Huang HM

    更新日期:2008-05-01 00:00:00

  • Effect of polymerization cycles on flexural strengths and microhardness of different denture base materials.

    abstract::The purpose of this study was to evaluate the effect of different polymerization cycles on the flexural strengths and microhardness of two denture base materials (Meliodent and Paladent). Heat-polymerized acrylic resin specimens (65.0 mm long×10.0 mm wide×2.5 mm in height) were prepared using different short and long ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-023

    authors: Gungor H,Gundogdu M,Alkurt M,Yesil Duymus Z

    更新日期:2017-03-31 00:00:00

  • A biocompatible model for evaluation of the responses of rat periapical tissue to a new zinc oxide-eugenol sealer.

    abstract::We aimed to establish an experimental animal model to evaluate materials for endodontic therapy. We focused on the biocompatibility of new paste-type zinc oxide-eugenol (ZOE) sealer. The results of this sealer were compared with those of conventional powder/liquid ZOE and eugenol-free sealers. The molars of Wistar rat...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-095

    authors: Mutoh N,Tani-Ishii N

    更新日期:2011-01-01 00:00:00

  • Microtensile bond strength of a newly developed resin cement to dentin.

    abstract::The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a newly developed resin cement, ECD-89 (ECD, Tokuyama Dental, Tokyo, Japan) to dentin and to observe the interfacial micromorphology by comparing with two commercial resin cements, Multilink Automix (MA, Ivoclar Vivadent AG, Schaan, Lie...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-122

    authors: Kawano S,Fu J,Saikaew P,Chowdhury AA,Fukuzawa N,Kadowaki Y,Kakuda S,Hoshika S,Nakaoki Y,Ikeda T,Tanaka T,Sano H

    更新日期:2015-01-01 00:00:00

  • Antimicrobial potential of bismuth lipophilic nanoparticles embedded into chitosan-based membrane.

    abstract::The objective of this work was to analyze the antimicrobial and antibiofilm activities of bismuth lipophilic nanoparticles (BisBAL NPs) incorporated into chitosan-based membranes. Chitosan-based membranes were homogeneously embedded with BisBAL NPs, confirming the bismuth presence by scanning electron microscopy. The ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-173

    authors: Martínez-Martínez MA,Hernandez-Delgadillo R,Abada BS,Pineda-Aguilar N,Solís-Soto JM,Nakagoshi-Cepeda MAA,Nakagoshi-Cepeda SE,Chellam S,Sánchez-Nájera RI,Cabral-Romero C

    更新日期:2019-07-31 00:00:00

  • Analysis of abutment tooth movement utilizing mandibular kinesiography (MKG). Part 2. Effects of clasp design in unilateral free-end denture.

    abstract::The three-dimensional dynamic movement of the abutment tooth was successfully analyzed on a simulation model utilizing the mandibular kinesiography. When the unilateral free-end denture retained by the RPA, RPI or Aker's clasp was subjected to various directions of loads, the abutment tooth was inclined mainly by the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.56

    authors: Morikawa M,Masumi S,Kido H,Toyoda S,Kozono Y

    更新日期:1989-06-01 00:00:00

  • New partition technique for two-chamber pressure casting unit for titanium.

    abstract::Although titanium has been widely used in prosthetic appliances, such as cast removable partial denture frameworks, high quality castings are still difficult to obtain. This study proposes a new partition technique using a metal foil for improving castability of a two-chamber pressure casting unit. The metal foil was ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.307

    authors: Watanabe K,Okawa S,Kanatani M,Nakano S,Miyakawa O,Kobayashi M

    更新日期:2000-09-01 00:00:00

  • Kinetic polymerization behavior of fluorinated monomers for dental use.

    abstract::The kinetic polymerization behavior of 2,2,2-trifluoroethyl methacrylate (TFEMA), 1,1,1,3,3,3-hexafluoroisopropyl methacrylate (HFIPMA), 2,2,2-trifluoroethyl acrylate (TFEA) and 1,1,1,3,3,3-hexafluoroisopropyl acrylate (HFIPA) was determined by isothermal differential scanning calorimetry (DSC) and high-performance li...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-054

    authors: Kadoma Y

    更新日期:2010-10-01 00:00:00

  • Deformation properties of Ti-6A1-7Nb alloy castings for removable partial denture frameworks.

    abstract::Ti-6Al-7Nb alloy was cast into three differently designed, removable partial denture frameworks: Palatal strap (PS), Anterior-posterior bar (AP), and Horseshoe-shaped bar (HS). The vertical displacement and local strain of Ti-6Al-7Nb alloy frameworks were investigated to compare against those of Co-Cr alloy frameworks...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.497

    authors: Srimaneepong V,Yoneyama T,Wakabayashi N,Kobayashi E,Hanawa T,Doi H

    更新日期:2004-12-01 00:00:00

  • Retention force of complete palate coverage and palate-less dentures in vitro.

    abstract::The purpose of this study was to investigate the retention force of complete palate coverage and palate-less dentures made with three polymerization systems (DS system, SR-Ivocap system, microwave polymerization system) in vitro. The retention force between each denture and a polyurethane model by intervening artifici...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.19

    authors: Teraoka F,Nakagawa M,Takahashi J

    更新日期:2004-03-01 00:00:00

  • Evaluation of brittleness of porcelain fused to pure titanium by fracture toughness, hardness and fracture energy.

    abstract::To elucidate the cause of brittleness of porcelain fused to pure titanium (PFPT) which leads to chipping and cracking similar to that of conventional porcelain in clinical use, fracture toughness KIc, hardness (Hv and Hk) and fracture energy gamma reflecting the bonding energy of atoms were evaluated. In KIc there wer...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.532

    authors: Higashino Y,Yamauchi M,Goto T,Nagasawa T

    更新日期:2003-12-01 00:00:00

  • Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions.

    abstract::This study compared differences in discoloration and dissolution in several titanium alloys with immersion in peroxide- or fluoride-containing solution. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-0.15Pd, Ti-6Al-4V, Ti-7Nb-6Al, Ti-55Ni, Ti-10Cu, and Ti-20Cr. Two test solutions were p...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.117

    authors: Noguchi T,Takemoto S,Hattori M,Yoshinari M,Kawada E,Oda Y

    更新日期:2008-01-01 00:00:00

  • Influence of mucin pre-adsorption for lipoteichoic acid adsorption on titanium surfaces.

    abstract::We investigated the adsorption of lipoteichoic acid (LTA) on titanium surfaces by using the quartz crystal microbalance (QCM) method, and confirmed the influence of mucin (MUC) pre-adsorption on LTA adsorption. Two injection methods were evaluated. Namely, Method A: single-step injection of LTA solution to the Ti sens...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-209

    authors: Yoshida E,Hayakawa T

    更新日期:2020-12-03 00:00:00

  • Bonding durability between orthodontic brackets and human enamel treated with megabond self-etching primer using 4-META/MMA-TBB resin cement.

    abstract::The purpose of this study was to determine the bonding durability when a Megabond self-etching primer is used with 4-META/MMA-TBB resin to bond metal orthodontic brackets to human premolar enamel. Three conditions of enamel were prepared: Megabond self-etching primer without saliva contamination, Megabond self-etching...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.251

    authors: Sirirungrojying S,Hayakawa T,Saito K,Meguro D,Nemoto K,Kasai K

    更新日期:2004-09-01 00:00:00

  • Effects of experimental pastes containing surface pre-reacted glass ionomer fillers on inhibition of enamel demineralization.

    abstract::This study aimed to evaluate the inhibitory effect of experimental pastes containing surface pre-reacted glass ionomer (S-PRG) fillers on enamel demineralization. Bovine blocks were treated twice a day for 4 days by 7 groups; experimental pastes containing 0-30 wt% S-PRG filler (S00, S01, S05, S10, and S30), deionized...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-303

    authors: Nakamura K,Hamba H,Nakashima S,Sadr A,Nikaido T,Oikawa M,Uo M,Tagami J

    更新日期:2017-07-26 00:00:00

  • Effect of new light curing units on microleakage and microhardness of resin sealants.

    abstract::To determine new developed light curing units with shorter curing times effects on microleakage and microhardness values for resin fissure sealants. Resin filled sealant (UltraSeal-XT), resin unfilled sealant (Delton Type-II) and ormocer-based sealant (Admira-Seal) were light cured with a quartz-tungsten-halogen (QTH)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-357

    authors: Bani M,Tirali RE

    更新日期:2016-01-01 00:00:00

  • Influence of a denture strengthener on the deformation of a maxillary complete denture.

    abstract::The present study investigated the influences of a denture strengthener on the deformation of a maxillary complete denture. Three groups of maxillary complete dentures were fabricated (Group 1 without a strengthener; Group 2 with a Co-Cr alloy wire strengthener; Group 3 with an experimental fiberglass strengthener). T...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.507

    authors: Hirajima Y,Takahashi H,Minakuchi S

    更新日期:2009-07-01 00:00:00

  • A study of in vivo degradation of two vital home bleaching gels.

    abstract::This study investigated hydrogen peroxide (H2O2) concentration of two home bleaching gels, in their dispensing syringes and their degradation in vivo in intraoral bleaching trays. Two bleaching gels were studied, 7.5% hydrogen peroxide (HP) and 20% carbamide peroxide (CP). The concentration of H2O2 was determined in d...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-317

    authors: Alonso De La Peña V,Rodriguez Carreira A,Corral Aneiros R,López Ratón M,Guitián Rivera F

    更新日期:2013-01-01 00:00:00

  • Effects of polishing on surface roughness and hardness of glass-fiber-reinforced polypropylene.

    abstract::Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-012

    authors: Tanimoto Y,Nagakura M

    更新日期:2018-11-30 00:00:00

  • Water durability of resin bond to pure gold treated with various adhesion promoting thiirane monomers.

    abstract::Adhesion promoting monomers for precious metals, 2,3-epithiopropyl methacrylate (EP1MA), 4,5-epithiopentyl methacrylate (EP3MA), 9,10-epithiodecyl methacrylate (EP8MA), 10,11-epithioundecyl methacrylate (EP9MA), 9,10-epithiodecyl 4-vinylbenzoate (EP8VB), 2,3-epithiocyclohexyl methacrylate (EPCHMA), and 3,4-epithiobuty...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.29

    authors: Kadoma Y,Kojima K,Tamaki Y,Nomura Y

    更新日期:2007-01-01 00:00:00