Abstract:
:The purpose of this study was to investigate the retention force of complete palate coverage and palate-less dentures made with three polymerization systems (DS system, SR-Ivocap system, microwave polymerization system) in vitro. The retention force between each denture and a polyurethane model by intervening artificial saliva was measured using a tensile tester. In addition, discrepancies between the denture base and the stone cast were measured at several points. The retention force of complete palate coverage and palate-less dentures made with the 3 polymerization systems shows that the DS system had a greater retention force than the SR-Ivocap system and the microwave system. Moreover, the retention force of palate-less dentures was greater than that of complete dentures only in the case of the DS system. The interaction of the polymerization system and the denture type also had a statistically significant effect on the retention force. Dentures made with the DS system had smaller discrepancies compared with dentures processed with the other systems. The retention force correlated very closely with discrepancies at the denture border and the residual ridge.
journal_name
Dent Mater Jjournal_title
Dental materials journalauthors
Teraoka F,Nakagawa M,Takahashi Jdoi
10.4012/dmj.23.19keywords:
subject
Has Abstractpub_date
2004-03-01 00:00:00pages
19-23issue
1eissn
0287-4547issn
1881-1361journal_volume
23pub_type
杂志文章abstract::The aim of this study was to evaluate the effect of resin infiltration on root caries induced by Streptococcus mutans biofilms. Human premolar specimens were divided to 5 groups: negative control (NC), Clearfil SE Bond (SEB), Icon-etch120s+Icon-infiltrant (HA120), Icon-etch10s+Icon-infiltrant (HA10) and K-etchant10s+I...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2016-229
更新日期:2017-03-31 00:00:00
abstract::The aim of our study was twofold: to immobilize an organosilicon quaternary ammonium salt (3-(trimethoxysilyl)-propyldimethyl-octadecyl ammonium chloride, Si-QAC) on the surface of pure titanium and to investigate the antimicrobial activity of Si-QAC-immobilized titanium against microbial adherence and biofilm formati...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.24.570
更新日期:2005-12-01 00:00:00
abstract::This study examined the surface microhardness of four kinds of resin composites with different fillers and resin matrices. Ten specimens of 2 mm thickness and 4 mm diameter of each resin composite were polymerized using a halogen light, a blue light-emitted diode, and a plasma arc unit. Microhardness evaluation was pe...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:
更新日期:2007-11-01 00:00:00
abstract::Three commercially available porcelains bonded to titanium were evaluated to determine the weakest zone of the titanium-porcelain bonding structures. Tensile bond tests were performed for these specimens (NO, DU, and VI) and for Ni-Cr alloy-porcelain bonding samples that served as controls. The maximum bond strengths ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2013-263
更新日期:2014-01-01 00:00:00
abstract::The diamond burs of two dental CAD/CAM systems (GN and CD) were examined if they could be used to fabricate up to 21 ceramic full crowns without fracture. After one, 11, and 21 machining times, the surfaces of the diamond burs were observed and the number of particles captured on SEM pictures was counted. The average ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.24.134
更新日期:2005-03-01 00:00:00
abstract::This study evaluated the influence of an aqueous propolis-based solution (PROP) on gap formation and bond strength of posts bonded to root canal dentin using resin cements. Endodontically-treated bovine incisors received different irrigation protocols: 1) 2.5% sodium hypochlorite (NaOCl)/17% EDTA/NaOCl; 2) saline solu...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2019-111
更新日期:2020-06-05 00:00:00
abstract::In this study, two types of porous zirconia and dense zirconia were used. The flexural strength of non-layered zirconia specimens and those of the layered zirconia specimens with veneering porcelain were examined. Furthermore, the shear bond strength of veneering porcelain to zirconia was examined. The flexural streng...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2013-191
更新日期:2014-01-01 00:00:00
abstract::This study investigated the changes in hardness and Young's modulus of the transparent layer of dentin associated with aging and the carious process. Eighteen extracted human molars with or without coronal caries were used in this study. The normal teeth were divided into two groups by age, and the carious teeth were ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.24.648
更新日期:2005-12-01 00:00:00
abstract::The depths of cure and the distributions of degree of conversion (DC), polymerization conversion (PC) and percent pendant double bonds (PDB) of light-cured composite resins cured under various intensities of light were investigated. When the total amount of exposure, represented by the product of the light intensity a...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.13.198
更新日期:1994-12-01 00:00:00
abstract::'Tooth-coloured' ProRoot MTA is an endodontic cement comprising an 80:20 wt% mixture of white Portland cement (WPC) and bismuth oxide. The setting reactions within this cement system are not currently well understood. Accordingly, this research monitors the early hydration chemistry of ProRoot MTA by X-ray diffraction...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2014-309
更新日期:2015-01-01 00:00:00
abstract::The aim of this study was to examine the lifespan or number of cycles to failure of tapered rotary nickel-titanium (Ni-Ti) endodontic instruments. Simulated root canals with different curvatures were used to determine a relation between canal curvature and instrument lifespan. Using a novel mathematical model for the ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2011-254
更新日期:2012-01-01 00:00:00
abstract::This study investigated the efficacies of adhesive resin cements (Clearfil SA Luting, Maxcem, G-CEM, RelyX Unicem Clicker, Vitremer Paste) for bonding to Ag-Pd-Cu-Au alloy not surface-pretreated with metal primer. For control, Panavia F 2.0 -developed for use with a proprietary metal primer, Alloy Primer- was tested w...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2010-093
更新日期:2011-01-01 00:00:00
abstract::Photocatalytic activity from the reaction of titanium oxide with ultraviolet light has recently gained much attention. In particular, there is scientific interest in inducing photocatalytic reactions on Ti-Ni alloy, a material widely used in orthodontic applications. However, it is believed that inducing a photocataly...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.26.924
更新日期:2007-11-01 00:00:00
abstract::We investigated the adsorption of lipoteichoic acid (LTA) on titanium surfaces by using the quartz crystal microbalance (QCM) method, and confirmed the influence of mucin (MUC) pre-adsorption on LTA adsorption. Two injection methods were evaluated. Namely, Method A: single-step injection of LTA solution to the Ti sens...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2019-209
更新日期:2020-12-03 00:00:00
abstract::The effects of monomer structure on the mechanical properties of visible light-cured composite resins based on the seven types of aromatic dimethacrylates were investigated. The results of this study suggested that the mechanical properties of the composite resins were dependent upon the chemical structure of the dime...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.8.40
更新日期:1989-06-01 00:00:00
abstract::The physical properties of experimental visible light-activated resins containing dyestuff, which could be quickly discolored by irradiation was, evaluated by analyzing light absorbance characteristics and measuring micro Vickers hardness. The experimental resin, which was prepared by mixing equivalent weights of Bis ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.8.147
更新日期:1989-12-01 00:00:00
abstract::The blending effect (BE) plays an important role in esthetics of the composite resin. The objective of this study was to determine the extents to which filler size and content affect the BE. Three types of fillers (0.7, 1.0, and 1.5 µm) were mixed at weight contents of 60, 70, 75, and 80%. This study simulated clinica...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2016-083
更新日期:2017-01-31 00:00:00
abstract::The purpose of this study was to propose a new numerical modeling of the glass fiber cloth reinforced denture base resin (GFRP). The proposed model is constructed with an isotropic shell, beam and orthotropic shell elements representing the outmost resin, interlaminar resin and glass fiber cloth, respectively. The pro...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.21.105
更新日期:2002-06-01 00:00:00
abstract::Temperature dependencies of thermal expansion coefficients for the alloys of Pd-Ag, Pd-Cu and Pd-Co binary systems were measured at temperatures up to 900 degrees C, with heating and cooling rates of 5 degrees C/min. The coefficient of thermal expansion of alloys with no transformation in the temperature range of inte...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.9.47
更新日期:1990-06-01 00:00:00
abstract::This study investigated the effects of spherical silica fillers on the physical and mechanical properties of resin-modified glass-ionomer cement (RMGIC). Specimens were fabricated by mixing untreated (UF) or silanized (SF) spherical silica filler into the powder of a commercially prepared RMGIC. The original RMGIC and...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.23.146
更新日期:2004-06-01 00:00:00
abstract::Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to i...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2018-012
更新日期:2018-11-30 00:00:00
abstract::The mechanical properties of resin-modified "hybrid" glass-ionomers, for both restorative and liner/base applications, were assessed by a flexural test and compared with those of conventional acid-base glass-ionomers. Flexural strength, flexural modulus, and the modulus of resilience were determined 30 minutes after m...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.14.109
更新日期:1995-12-01 00:00:00
abstract::This study evaluated the influence of filling technique and curing mode on the microtensile bond strengths (MTBS) of composite cores to pulpal floor dentin. Access cavities of human molars with pulpal floor dentin were restored with a two-step self-etch adhesive system, Clearfil Liner Bond 2V and a composite core, Cle...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2009-104
更新日期:2010-10-01 00:00:00
abstract::The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before ...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.28.307
更新日期:2009-05-01 00:00:00
abstract::Oral bacteria adhered to dental material surfaces are known to cause various oral diseases. This study aimed to develop a highsensitive and non-radioisotopic fluorescence dye method for quantification of oral bacteria (Streptococcus, Actinomyces and Veillonella) adhered to denture material surfaces. The amount of adhe...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2013-060
更新日期:2013-01-01 00:00:00
abstract::This study investigated hydrogen peroxide (H2O2) concentration of two home bleaching gels, in their dispensing syringes and their degradation in vivo in intraoral bleaching trays. Two bleaching gels were studied, 7.5% hydrogen peroxide (HP) and 20% carbamide peroxide (CP). The concentration of H2O2 was determined in d...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.2012-317
更新日期:2013-01-01 00:00:00
abstract::To clarify the mechanical properties of fiber-reinforced hybrid resin bridges, this study evaluated the influence of various bonding agents ((Modeling Liquid (ML), DE Resin (DE), Bell Bond (BE), Mega Bond (MG), Durafil Bond (DU), Fluoro Bond (FB), Mac-Bond (MC), EG Bond (EG), Unifill Bond (UN), Single Bond (SN)) impre...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.27.723
更新日期:2008-09-01 00:00:00
abstract::The biaxial flexural strength and cyclic fatigue biaxial flexural strength of CAD/CAM ceramics polished with #220, 400, 600 and 1000 diamond pads were measured in an effort to determine the effect of surface roughness on fatigue behavior of dental ceramics. The surface roughness was improved after polishing with a sma...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.18.395
更新日期:1999-12-01 00:00:00
abstract::To investigate the bonding of tooth-colored indirect restorations to cervical dentin, shear bond strengths of bonded resin inlays to cervical dentin and mid-coronal dentin were investigated and compared. Indirectly fabricated composite inlays (Estenia) were cemented with a dual-cured resin cement (Panavia Fluoro Cemen...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.25.7
更新日期:2006-03-01 00:00:00
abstract::The corrosion behavior of three Ni-Ti alloys with compositions as commercial super-elastic orthodontic wires was investigated using polished plate specimens. Corrosion resistance was estimated by potentiodynamic polarization measurement in 0.9% NaCl and 1% lactic acid solutions and analysis of released metals by atomi...
journal_title:Dental materials journal
pub_type: 杂志文章
doi:10.4012/dmj.17.31
更新日期:1998-03-01 00:00:00