Influences of filler content and size on the color adjustment potential of nonlayered resin composites.

Abstract:

:The blending effect (BE) plays an important role in esthetics of the composite resin. The objective of this study was to determine the extents to which filler size and content affect the BE. Three types of fillers (0.7, 1.0, and 1.5 µm) were mixed at weight contents of 60, 70, 75, and 80%. This study simulated clinical class 3 or 4 cavities and quantitatively measured the color diffusion of the objects next to the cavities based on the CIELab color space. For each filler size, there was a trend of increasing BE as the filler content was increased. The translucency parameter (TP) exhibited the opposite trend of decreasing (p<0.05) with increases in filler content. The filler size did not affect the BE, and the different filler sizes produced statistically non-significant results in this study. Increases in filler content elevated the opacity of the composite resin and significantly influenced the BE.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Suh YR,Ahn JS,Ju SW,Kim KM

doi

10.4012/dmj.2016-083

subject

Has Abstract

pub_date

2017-01-31 00:00:00

pages

35-40

issue

1

eissn

0287-4547

issn

1881-1361

journal_volume

36

pub_type

杂志文章
  • Light activated resin containing organic dyestuff.

    abstract::The physical properties of experimental visible light-activated resins containing dyestuff, which could be quickly discolored by irradiation was, evaluated by analyzing light absorbance characteristics and measuring micro Vickers hardness. The experimental resin, which was prepared by mixing equivalent weights of Bis ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.147

    authors: Nakazato J,Itoh K,Wakumoto S

    更新日期:1989-12-01 00:00:00

  • Hardness and Young's modulus of transparent dentin associated with aging and carious disease.

    abstract::This study investigated the changes in hardness and Young's modulus of the transparent layer of dentin associated with aging and the carious process. Eighteen extracted human molars with or without coronal caries were used in this study. The normal teeth were divided into two groups by age, and the carious teeth were ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.648

    authors: Zheng L,Nakajima M,Higashi T,Foxton RM,Tagami J

    更新日期:2005-12-01 00:00:00

  • Evaluation of an articulated measuring apparatus for use in the oral cavity.

    abstract::The aim of this study was to evaluate the trial Teaching Robot for the development of a contact-type measuring apparatus for using directly in the oral cavity. A standard model was used to mimic the dentition by placing an arrangement of three bearing balls. The diameters of the balls were measured. A practical dentit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.168

    authors: Maikuma Y,Usui K,Araki K,Mataki S,Kurosaki N,Furuya N

    更新日期:2003-06-01 00:00:00

  • Effects of light sources and visible light-activated titanium dioxide photocatalyst on bleaching.

    abstract::The objective of this study was to evaluate, using methylene blue (MB), the effects of various light sources on the bleaching action of hydrogen peroxide (H(2)O(2)) with two titanium dioxide (TiO(2)) photocatalysts - an ultraviolet light-activated TiO(2) photocatalyst (UVTiO(2)) versus a visible light-activated TiO(2)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.693

    authors: Suyama Y,Otsuki M,Ogisu S,Kishikawa R,Tagami J,Ikeda M,Kurata H,Cho T

    更新日期:2009-11-01 00:00:00

  • Effect of monomer structure on the mechanical properties of light-cured composite resins.

    abstract::The effects of monomer structure on the mechanical properties of visible light-cured composite resins based on the seven types of aromatic dimethacrylates were investigated. The results of this study suggested that the mechanical properties of the composite resins were dependent upon the chemical structure of the dime...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.40

    authors: Kawaguchi M,Fukushima T,Horibe T

    更新日期:1989-06-01 00:00:00

  • Effect of adhesive primer developed exclusively for heat-curing resin on adhesive strength between plastic artificial tooth and acrylic denture base resin.

    abstract::Despite progress in the development of denture base resin and artificial tooth materials, dental clinics are still plagued with artificial teeth falling off the denture base--due to poor bond strength--after denture delivery. Against this background, this study sought to examine the effect and durability of an adhesiv...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.75

    authors: Nishigawa G,Maruo Y,Okamoto M,Oki K,Kinuta Y,Minagi S,Irie M,Suzuki K

    更新日期:2006-03-01 00:00:00

  • Bone formation and osseointegration with titanium implant using granular- and block-type porous hydroxyapatite ceramics (IP-CHA).

    abstract::The aim of the present study was to examine whether interconnected porous hydroxyapatite ceramics (IP-CHA) could be used as bone substitute for implant treatment in reconstructive surgery. We firstly assessed if surround of the titanium surface placed into granular or block-type IP-CHA can observe new bone formation i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-169

    authors: Minami M,Takechi M,Ohta K,Ohta A,Ninomiya Y,Takamoto M,Fukui A,Tada M,Kamata N

    更新日期:2013-01-01 00:00:00

  • Micro computed tomography evaluation of the Self-adjusting file and ProTaper Universal system on curved mandibular molars.

    abstract::The aim of this investigation was to compare the cleaning and shaping efficiency of Self-adjusting file and Protaper, and to assess the correlation between root canal curvature and working time in mandibular molars using micro-computed tomography. Twenty extracted mandibular molars instrumented with Protaper and Self-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-255

    authors: Serefoglu B,Piskin B

    更新日期:2017-09-26 00:00:00

  • Effectiveness of sodium hypochlorite and sulfinic acid sodium salt treatment on dentin-resin bonding: Long-term durability of one-step self-etching adhesive.

    abstract::This study aimed to evaluate the effect of sulfinic acid sodium salt interposition after acid and sodium hypochlorite treatment (NC treatment) on dentin bonding durability using a mild type one-step self-etching adhesive. Fifteen human third molars were randomly assigned into three experimental groups according to den...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-105

    authors: Nakatani H,Mine A,Matsumoto M,Kabetani T,Kawaguchi-Uemura A,Higashi M,Tajiri Y,Imai D,Hagino R,Minamino T,Miura J,Yatani H

    更新日期:2017-11-29 00:00:00

  • Mold filling and microhardness of 1% Fe titanium alloys.

    abstract::We examined the mold filling capacity and microhardness of two industrial 1% Fe titanium alloys: Super-TIX800 (Nippon Steel Corp.) (Fe: 0.910%, O: 0.370%, N: 0.005%) and Super-TIX800N (Nippon Steel Corp.) (Fe: 0.960%, O: 0.300%, N: 0.041%). Two wedge-shaped acrylic patterns (with 30 degrees or 15 degrees angles) were ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.211

    authors: Sato H,Komatsu M,Miller B,Shimizu H,Fujii H,Okabe T

    更新日期:2004-06-01 00:00:00

  • Effect of placement technique on the push-out bond strength of calcium-silicate based cements.

    abstract::The purpose of this study was to evaluate the effects of ultrasonic and manual placement techniques on the push-out bond strength of Biodentine and MTA with and without calcium chloride. One hundred and twenty mid-root slices from forty freshly extracted single-rooted human mandibular premolar teeth were instrumented ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-094

    authors: Küçükkaya Eren S,Aksel H,Serper A

    更新日期:2016-10-01 00:00:00

  • Effect of surface preparation on the bond strength of heat-polymerized denture base resin to commercially pure titanium and cobalt-chromium alloy.

    abstract::The aim of this study was to investigate the bond durability of heat-polymerized denture base resin to cast CP Ti and Co-Cr alloy. The alloy specimens were divided into five groups: 1) airborne-particle abraded with 50 µm alumina (SAND), 2) Rocatec tribochemical silica coating system (RO), 3) air-abraded followed by a...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2010-089

    authors: Kawaguchi T,Shimizu H,Lassila LV,Vallittu PK,Takahashi Y

    更新日期:2011-01-01 00:00:00

  • Effects of experimental pastes containing surface pre-reacted glass ionomer fillers on inhibition of enamel demineralization.

    abstract::This study aimed to evaluate the inhibitory effect of experimental pastes containing surface pre-reacted glass ionomer (S-PRG) fillers on enamel demineralization. Bovine blocks were treated twice a day for 4 days by 7 groups; experimental pastes containing 0-30 wt% S-PRG filler (S00, S01, S05, S10, and S30), deionized...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-303

    authors: Nakamura K,Hamba H,Nakashima S,Sadr A,Nikaido T,Oikawa M,Uo M,Tagami J

    更新日期:2017-07-26 00:00:00

  • A new procedure of the tensile fatigue test for dental materials.

    abstract::A new tensile fatigue test using a stainless steel screw was introduced. A transparent PMMA rod was selected as the test material. A hole was drilled and tapped into the rod; a screw was put into the rod with dental cement or without cementation. Three types of cyclic loads were applied to the test piece; the number o...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.11.141

    authors: Nishimura F,Nakamura H,Watari F,Tanaka I,Takahashi H

    更新日期:1992-12-01 00:00:00

  • The extent of polymerization of Class II light-cured composite resin restorations; effects of incremental placement technique, exposure time and heating for resin inlays.

    abstract::The extent of polymerization of light-cured composite resins cured in relatively large class II cavities was estimated by measuring Knoop hardness on sectioned surfaces of resin restorations. The influences of the incremental placement technique, exposure time, and post-curing of resin inlay on the extent of polymeriz...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.159

    authors: Hirabayashi S,Hood JA,Hirasawa T

    更新日期:1993-12-01 00:00:00

  • Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor.

    abstract::The purpose of this study was to evaluate the effect of various incremental filling techniques on adhesion between composite and cavity floor using light-cured resin composite. Black ABS resin and hybrid resin composite were used as mold materials--instead of dentin--for the preparation of cavities, and standardized t...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.503

    authors: Chikawa H,Inai N,Cho E,Kishikawa R,Otsuki M,Foxton RM,Tagami J

    更新日期:2006-09-01 00:00:00

  • Improving biocompatibility of zirconia surface by incorporating Ca ions.

    abstract::Though zirconia has been used in dental implant fixtures, the biocompatibility of the zirconia surface is not optimal for the surrounding tissue, and many surface modifications have been attempted. We have developed a novel method for improving the biocompatibility of zirconia by incorporating Ca ions. Elemental analy...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-199

    authors: Sasaki K,Hayashi T,Asakura M,Ando M,Kawai T,Ban S

    更新日期:2015-01-01 00:00:00

  • The preparation of PLLA/calcium phosphate hybrid composite and its evaluation of biocompatibility.

    abstract::In tissue engineering, biodegradable polymer materials with both high biocompatibility and high strength are very important as scaffolds for long term use. Therefore, in this research, we tried to prepare the three types of poly(L-lactic acid) (PLLA)/calcium phosphate (CP) hybrid composite for a scaffold biomaterial. ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-117

    authors: Hamada Y,Fujitani W,Kawaguchi N,Daito K,Niido T,Uchinaka A,Mori S,Kojima Y,Manabe M,Nishida K,Arita K,Nakano T,Matsuura N

    更新日期:2012-01-01 00:00:00

  • Immobilization of octadecyl ammonium chloride on the surface of titanium and its effect on microbial colonization in vitro.

    abstract::The aim of our study was twofold: to immobilize an organosilicon quaternary ammonium salt (3-(trimethoxysilyl)-propyldimethyl-octadecyl ammonium chloride, Si-QAC) on the surface of pure titanium and to investigate the antimicrobial activity of Si-QAC-immobilized titanium against microbial adherence and biofilm formati...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.570

    authors: Nikawa H,Ishida K,Hamada T,Satoda T,Murayama T,Takemoto T,Tamamoto M,Tajima H,Shimoe S,Fujimoto H,Makihira S

    更新日期:2005-12-01 00:00:00

  • Evaluation of brittleness of porcelain fused to pure titanium by fracture toughness, hardness and fracture energy.

    abstract::To elucidate the cause of brittleness of porcelain fused to pure titanium (PFPT) which leads to chipping and cracking similar to that of conventional porcelain in clinical use, fracture toughness KIc, hardness (Hv and Hk) and fracture energy gamma reflecting the bonding energy of atoms were evaluated. In KIc there wer...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.532

    authors: Higashino Y,Yamauchi M,Goto T,Nagasawa T

    更新日期:2003-12-01 00:00:00

  • Titanium removable denture based on a one-metal rehabilitation concept.

    abstract::The use of a single metal for all restorations would be necessary because it protects against metal corrosion caused by the contact of different metals. For this "one-metal rehabilitation" concept, non-alloyed commercially pure (CP) titanium should be used for all restorations. Titanium frameworks have been cast and u...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-137

    authors: Ohkubo C,Sato Y,Nishiyama Y,Suzuki Y

    更新日期:2017-09-26 00:00:00

  • Novel, multi-purpose, PMMA-type adhesive resin with newly synthesized microcapsule of radical polymerization initiators.

    abstract::The behavior of microencapsulated polymerization initiators in dental adhesives is unknown. This study investigated the effects of new microencapsulated initiators in novel, multi-purpose, PMMA-type adhesive resin on the bonding performance and polymerization reactivity. Microencapsulated BPO and 1,3,5-trimethylbarbit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.35

    authors: Fuchigami K,Ikemura K,Ichizawa K

    更新日期:2008-01-01 00:00:00

  • Bactericidal efficacy of glycine-type amphoteric surfactant as a denture cleaner and its influence on properties of denture base resins.

    abstract::The bactericidal efficacy of 1.00-4.50% glycine-type amphoteric surfactant (Gly) was evaluated by measuring its microorganism removal rate in denture plaque. Physical and mechanical properties such as surface roughness, color difference, and bending strength of two different denture base resins were determined before ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.307

    authors: Hashiguchi M,Nishi Y,Kanie T,Ban S,Nagaoka E

    更新日期:2009-05-01 00:00:00

  • Changes on NiTi orthodontic wired due to acidic fluoride solution.

    abstract::The effect of acidic fluoride solution on NiTi arch wires was examined by testing crystal structure, tensile strength, morphology after fracture, and element release from wire under four different test solutions after 1 or 3 d immersion. Three-day immersion in a 0.2%/pH 4 solution did not form any new crystal structur...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.557

    authors: Kwon YH,Cheon YD,Seol HJ,Lee JH,Kim HI

    更新日期:2004-12-01 00:00:00

  • Bioactive-glass in periodontal surgery and implant dentistry.

    abstract::Bioactive-glass (B-G) is a material known for its favorable biological response when in contact with surrounding fibro-osseous tissues, due not only to an osteoconductive property, but also to an osteostimulatory capacity, and superior biocompatibility for use in human body. The objectives of this paper are to review ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-233

    authors: Profeta AC,Prucher GM

    更新日期:2015-01-01 00:00:00

  • Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin.

    abstract::The aim of this study was to investigate in how far the way the specimen is fixed to the testing device influences the micro-tensile bond strength of adhesives to dentin. Compared to a flat jig, a notched jig enables the specimen to be aligned easier and more accurately perpendicular to the interface, thereby concentr...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.694

    authors: Poitevin A,De Munck J,Van Landuyt K,Coutinho E,Peumans M,Lambrechts P,Van Meerbeek B

    更新日期:2007-09-01 00:00:00

  • Effect of commercially available bonding agents impregnated with fibers on bending strength of hybrid resin.

    abstract::To clarify the mechanical properties of fiber-reinforced hybrid resin bridges, this study evaluated the influence of various bonding agents ((Modeling Liquid (ML), DE Resin (DE), Bell Bond (BE), Mega Bond (MG), Durafil Bond (DU), Fluoro Bond (FB), Mac-Bond (MC), EG Bond (EG), Unifill Bond (UN), Single Bond (SN)) impre...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.723

    authors: Tsushima S,Gomi H,Shinya A,Yokoyama D,Vallittu PK,Shinya A

    更新日期:2008-09-01 00:00:00

  • Effects of thermal cycling and surface roughness on the Weibull distribution of porcelain strength.

    abstract::The objective of this study was to test the hypothesis that thermal cycling weakens the flexural strength of porcelain. Specimens of Deguceram Gold and Vita Omega 900 were tested in four groups of 30 specimens each: in the original glazed condition versus being ground with 1000-grit, 600-grit, and 100-grit silicon car...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.433

    authors: Nakamura Y,Hojo S,Sato H

    更新日期:2009-07-01 00:00:00

  • Irrigation effectiveness of continuous ultrasonic irrigation system: An ex vivo study.

    abstract::This study evaluated the irrigation extrusion and smear layer (SL) removal of continuous ultrasonic irrigation (CUI). Forty root canals were shaped, embedded in warm sterile saline agar colored with 1% acid red, and distributed into four groups; three groups had the final irrigation sequence of sodium hypochlorite and...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-411

    authors: Jamleh A,Suda H,Adorno CG

    更新日期:2018-01-30 00:00:00

  • Influence of mucin pre-adsorption for lipoteichoic acid adsorption on titanium surfaces.

    abstract::We investigated the adsorption of lipoteichoic acid (LTA) on titanium surfaces by using the quartz crystal microbalance (QCM) method, and confirmed the influence of mucin (MUC) pre-adsorption on LTA adsorption. Two injection methods were evaluated. Namely, Method A: single-step injection of LTA solution to the Ti sens...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-209

    authors: Yoshida E,Hayakawa T

    更新日期:2020-12-03 00:00:00