New partition technique for two-chamber pressure casting unit for titanium.

Abstract:

:Although titanium has been widely used in prosthetic appliances, such as cast removable partial denture frameworks, high quality castings are still difficult to obtain. This study proposes a new partition technique using a metal foil for improving castability of a two-chamber pressure casting unit. The metal foil was formed beforehand to bring it in contact with the mold crucible wall so that no clearance was left behind it. Using this formed foil, the mold cavity can be completely isolated from the upper chamber and can be maintained in a vacuum even after the rupture of the foil. Accordingly, a large casting force is generated very quickly, and as a result, castability is expected to be significantly improved. This expectation was confirmed by the experiments using wax patterns including thin plate and mesh plate.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Watanabe K,Okawa S,Kanatani M,Nakano S,Miyakawa O,Kobayashi M

doi

10.4012/dmj.19.307

keywords:

subject

Has Abstract

pub_date

2000-09-01 00:00:00

pages

307-16

issue

3

eissn

0287-4547

issn

1881-1361

journal_volume

19

pub_type

杂志文章
  • Anti-demineralization characteristics of surface pre-reacted glass-ionomer (S-PRG) filler-containing varnishes.

    abstract::This study investigated the anti-demineralization effects of surface pre-reacted glass-ionomer (S-PRG) filler-containing varnishes. Thirty-five bovine root specimens were divided into five treatment groups, with seven specimens each coated with 1) MI varnish (MIV), 2) F varnish (FV), 3) PRG varnish I (PV), 4) PRG varn...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-396

    authors: Shiiya T,Kataoka A,Tomiyama K,Fujino F,Mukai Y

    更新日期:2020-11-11 00:00:00

  • Evaluation of the amount of residual monomer on UDMA-based resins by FTIR.

    abstract::The purpose of this study was to establish a method using FTIR to evaluate the polymerization characteristics of UDMA-based resins. Three kinds of experimental UDMA-based resins were prepared with various molar fractions. IR spectra of the cured film specimens were measured with FTIR before and after extracting residu...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.18.176

    authors: Nomoto R,Hirasawa T

    更新日期:1999-06-01 00:00:00

  • Contraction gap versus shear bond strength of dentin adhesive in sound and sclerotic dentins.

    abstract::To evaluate the effect of a dentin adhesive on sclerotic dentin, contraction gap width and shear bond strength were measured. Dentin cavity wall was pretreated with an experimental dentin bonding system with and without a dentin primer, or with a commercial dentin bonding system. In the experimental dentin bonding gro...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.576

    authors: Kusunoki M,Itoh K,Takahashi Y,Hisamitsu H

    更新日期:2006-09-01 00:00:00

  • Effects of polishing on surface roughness and hardness of glass-fiber-reinforced polypropylene.

    abstract::Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-012

    authors: Tanimoto Y,Nagakura M

    更新日期:2018-11-30 00:00:00

  • Modification of electrochemically deposited apatite using supercritical water.

    abstract::Supercritical water was used as a modification method of electrochemically deposited apatite on pure titanium. The apatites were coated on a commercially pure titanium plate using a hydrothermal-electrochemical method. A constant direct current at 12.5 mA/cm2 was loaded for 1 hr at 25, 60, 100, 150 and 200 degrees C i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.247

    authors: Ban S,Hasegawa J

    更新日期:2001-12-01 00:00:00

  • Effect of bidirectional loading on contact and force characteristics under a newly developed masticatory simulator with a dual-direction loading system.

    abstract::Mechanical responses of the test specimen under bidirectional and unidirectional loading were investigated using a newly developed masticatory simulator. The simulator adopted a four-bar linkage mechanism to create both loading patterns. Scratch/occlusal contact characteristics, contact force profiles and the fracture...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-198

    authors: Singhatanadgit W,Junkaew P,Singhatanadgid P

    更新日期:2016-01-01 00:00:00

  • Evaluation of brittleness of porcelain fused to pure titanium by fracture toughness, hardness and fracture energy.

    abstract::To elucidate the cause of brittleness of porcelain fused to pure titanium (PFPT) which leads to chipping and cracking similar to that of conventional porcelain in clinical use, fracture toughness KIc, hardness (Hv and Hk) and fracture energy gamma reflecting the bonding energy of atoms were evaluated. In KIc there wer...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.532

    authors: Higashino Y,Yamauchi M,Goto T,Nagasawa T

    更新日期:2003-12-01 00:00:00

  • Bonding durability between orthodontic brackets and human enamel treated with megabond self-etching primer using 4-META/MMA-TBB resin cement.

    abstract::The purpose of this study was to determine the bonding durability when a Megabond self-etching primer is used with 4-META/MMA-TBB resin to bond metal orthodontic brackets to human premolar enamel. Three conditions of enamel were prepared: Megabond self-etching primer without saliva contamination, Megabond self-etching...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.251

    authors: Sirirungrojying S,Hayakawa T,Saito K,Meguro D,Nemoto K,Kasai K

    更新日期:2004-09-01 00:00:00

  • Hardness and Young's modulus of transparent dentin associated with aging and carious disease.

    abstract::This study investigated the changes in hardness and Young's modulus of the transparent layer of dentin associated with aging and the carious process. Eighteen extracted human molars with or without coronal caries were used in this study. The normal teeth were divided into two groups by age, and the carious teeth were ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.648

    authors: Zheng L,Nakajima M,Higashi T,Foxton RM,Tagami J

    更新日期:2005-12-01 00:00:00

  • Effect of finishing condition on fracture strength of monolithic zirconia crowns.

    abstract::This study was to evaluate the load bearing capacity of monolithic dental zirconia crowns, and the effect of surface finishing on fracture strength. (1) The zirconia plates were divided into 5 groups and polished by various types of polishing bur, every specimen was analyzed by surface roughness testing, and X-ray dif...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-391

    authors: Yin R,Lee MH,Bae TS,Song KY

    更新日期:2019-03-31 00:00:00

  • Proliferation and differentiation of cultured MC3T3-E1 osteoblasts on surface-layer modified hydroxyapatite ceramic with acid and heat treatments.

    abstract::Effects of functionally gradient calcium phosphate consisting of hydroxyapatite (HAP) and alpha-tricalcium phosphate (alpha-TCP) on proliferation and differentiation of osteoblasts were evaluated using MC3T3-E1 cells. There were no significant differences in the proliferation of MC3T3-E1 cells among HAP-alpha-TCP func...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.207

    authors: Yuasa T,Miyamoto Y,Kon M,Ishikawa K,Takechi M,Momota Y,Tatehara S,Takano H,Mimamiguchi S,Nagayama M

    更新日期:2005-06-01 00:00:00

  • The protective effect of resveratrol against dentin bonding agents-induced cytotoxicity.

    abstract::This study was designed to evaluate the cytotoxicity of four dentin bonding agents and the effects of an antioxidant addition. Group A: G-aenial Bond, Group B: Optibond All in One, Group C: Gluma Self Etch and Group D: Clearfil S(3) Bond were added to the medium using extract method. The cells were cultured with or wi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-079

    authors: Atalayin C,Armagan G,Konyalioglu S,Kemaloglu H,Tezel H,Ergucu Z,Keser A,Dagci T,Onal B

    更新日期:2015-01-01 00:00:00

  • Effect of different remaining dentin thickness and long term water storage on dentin bond strength.

    abstract::The purpose of this study was to investigate the effect of remaining dentin thickness (RDT) and long term water storage on dentin bond strength in-vitro. Twenty-seven third molars were randomly divided into 3 groups: Clearfil Bond SE ONE (SE1, Kuraray Noritake Dental, Okayama, Japan), G-Bond plus (GB, GC, Tokyo, Japan...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-140

    authors: Ting S,Chowdhury AFMA,Sun J,Kakuda S,Sidhu SK,Yoshida Y,Selimovic D,Sano H

    更新日期:2018-07-29 00:00:00

  • Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses.

    abstract::This study evaluated and compared the influence of different supporting abutment models on the fracture loads of three-unit fixed dental prostheses (FDPs) fabricated from the following materials (n=24/material): (i) IPS e.max CAD-on, (ii) IPS e.max ZirCAD, and (iii) Telio CAD. Twelve FDPs of each group were adhesively...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-344

    authors: Wimmer T,Erdelt KJ,Eichberger M,Roos M,Edelhoff D,Stawarczyk B

    更新日期:2014-01-01 00:00:00

  • Bone formation and osseointegration with titanium implant using granular- and block-type porous hydroxyapatite ceramics (IP-CHA).

    abstract::The aim of the present study was to examine whether interconnected porous hydroxyapatite ceramics (IP-CHA) could be used as bone substitute for implant treatment in reconstructive surgery. We firstly assessed if surround of the titanium surface placed into granular or block-type IP-CHA can observe new bone formation i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-169

    authors: Minami M,Takechi M,Ohta K,Ohta A,Ninomiya Y,Takamoto M,Fukui A,Tada M,Kamata N

    更新日期:2013-01-01 00:00:00

  • Effects of experimental pastes containing surface pre-reacted glass ionomer fillers on inhibition of enamel demineralization.

    abstract::This study aimed to evaluate the inhibitory effect of experimental pastes containing surface pre-reacted glass ionomer (S-PRG) fillers on enamel demineralization. Bovine blocks were treated twice a day for 4 days by 7 groups; experimental pastes containing 0-30 wt% S-PRG filler (S00, S01, S05, S10, and S30), deionized...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-303

    authors: Nakamura K,Hamba H,Nakashima S,Sadr A,Nikaido T,Oikawa M,Uo M,Tagami J

    更新日期:2017-07-26 00:00:00

  • Discoloration and dissolution of titanium and titanium alloys with immersion in peroxide- or fluoride-containing solutions.

    abstract::This study compared differences in discoloration and dissolution in several titanium alloys with immersion in peroxide- or fluoride-containing solution. Commercially pure titanium (CP-Ti) and six titanium-based alloys were used: Ti-0.15Pd, Ti-6Al-4V, Ti-7Nb-6Al, Ti-55Ni, Ti-10Cu, and Ti-20Cr. Two test solutions were p...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.117

    authors: Noguchi T,Takemoto S,Hattori M,Yoshinari M,Kawada E,Oda Y

    更新日期:2008-01-01 00:00:00

  • Zirconia ceramics, their contrast ratio and grain size depending on sintering parameters.

    abstract::This study investigated the contrast ratio and grain size depending on sintering parameters of twelve different zirconia materials and compared with glass-ceramic (N=156, n=12 per group). Contrast ratio of all ceramics was measured using a spectrophotometer according to ISO 2471: 2008. Grain sizes of zirconia were det...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-056

    authors: Stawarczyk B,Emslander A,Roos M,Sener B,Noack F,Keul C

    更新日期:2014-01-01 00:00:00

  • Fluorescence of thulium-doped translucent zirconia.

    abstract::The fluorescence and physical properties of thulium-doped zirconia were investigated. A standard grade of zirconia (TZ-3Y-E) and two translucent dental zirconia materials (Zpex and Zpex Smile) were examined. The specimens were prepared by addition of 0-1.5 wt% Tm2O3 and then sintering. When exposed to UV light, the Tm...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-384

    authors: Nakamura T,Okamura S,Nishida H,Usami H,Nakano Y,Wakabayashi K,Sekino T,Yatani H

    更新日期:2018-11-30 00:00:00

  • In vivo analyses of the effects of polyamidoamine dendrimer on dentin biomineralization and dentinal tubules occlusion.

    abstract::This study evaluated the biomineralization and dentinal tubules occlusion abilities of the carboxyl-terminated polyamidoamine dendrimer (PAMAM-COOH) on human demineralized dentin in vivo at different time points. Demineralization dentin model with and without treated with PAMAM-COOH were sutured to the interior side o...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-209

    authors: Xie F,Wei X,Li Q,Zhou T

    更新日期:2016-01-01 00:00:00

  • Antibacterial activity of composite resin with glass-ionomer filler particles.

    abstract::The purpose of this study was to examine the antibacterial activity of composite resin with glass-ionomer filler particles versus that of contemporary commercial composite resins. Three composite resins were used: Beautifil II (containing S-PRG filler), Clearfil AP-X, and Filtek Z250. Resin blocks were bonded to maxil...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2009-050

    authors: Saku S,Kotake H,Scougall-Vilchis RJ,Ohashi S,Hotta M,Horiuchi S,Hamada K,Asaoka K,Tanaka E,Yamamoto K

    更新日期:2010-03-01 00:00:00

  • Shear bond strengths of a single-step bonding system to enamel and dentin.

    abstract::An experimental primer was developed as a single-step bonding system for resin-modified glass ionomer cements (GIC). Efficacy of this primer on adhesion of resin-modified GICs and resin composite to enamel and dentin was evaluated by shear bond test and SEM observation. Good bond strengths to enamel were obtained (> 1...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.16.40

    authors: Nikaido T,Nakajima M,Higashi T,Kanemura N,Pereira PN,Tagami J

    更新日期:1997-06-01 00:00:00

  • Bond strength of artificial teeth to thermoplastic denture base resin for injection molding.

    abstract::This research was conducted to investigate the bond strength between artificial teeth and a thermoplastic denture base resin for injection molding with different surface preparations for use in flexible resin removable partial dentures. Composite resin denture teeth and acrylic denture resin teeth were bonded to three...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-183

    authors: Tashiro S,Kawaguchi T,Hamanaka I,Takahashi Y

    更新日期:2021-01-15 00:00:00

  • Effects of incorporation of nano-fluorapatite particles on microhardness, fluoride releasing properties, and biocompatibility of a conventional glass ionomer cement (GIC).

    abstract::Present study evaluated effects of addition of Nanoparticles fluorapatite (Nano-FA) on microhardness and fluoride release of a Glass Ionomer Cement (GIC, Fuji IX GP Fast). Forty-eight specimens prepared, divided equally into 4 groups (2 with Nano-FA); after 24 h and one week Vickers microhardness (HV) was measured. Na...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-437

    authors: Moshaverinia M,Borzabadi-Farahani A,Sameni A,Moshaverinia A,Ansari S

    更新日期:2016-01-01 00:00:00

  • Bond strength and microleakage of self-adhesive and conventional fissure sealants.

    abstract::The aim of this study was to compare the shear bond strengths (SBS), failure modes (adhesive, cohesive, or mixed), and marginal microleakage occurrence of conventional resin (CR)-based, glass ionomer (GI)-based, and self-adhesive resin (SAR)-based fissure sealants with or without prior phosphoric acid (PA) etching. Fi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-227

    authors: Simsek Derelioglu S,Yilmaz Y,Celik P,Carikcioglu B,Keles S

    更新日期:2014-01-01 00:00:00

  • Measurement of the remaining dentin thickness using optical coherence tomography for crown preparation.

    abstract::This study aimed to investigate the maximum depth imaging and optical properties of the dentin near the pulp by using optical coherence tomography (OCT) and to explore the possibility of measuring the remaining dentin thickness (RDT). Human third molars were used. In experiment 1, the cuspal dentin blocks (0.50-mm to ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-303

    authors: Fujita R,Komada W,Nozaki K,Miura H

    更新日期:2014-01-01 00:00:00

  • Effects of temperature-responsive hydrogel on viscosity of denture adhesives.

    abstract::The cream type of denture adhesives after use cannot be easily removed from oral mucosa and have the potential risk to change the oral flora. The effects of the temperature-responsive hydrogel Pluronic F-127 (PF) on the complex viscosity of denture adhesives were evaluated. Carboxy methylcellulose (CMC) mass fractions...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-191

    authors: Zhao H,Akiba N,Tanimoto H,Yoshizaki T,Yalikun K,Minakuchi S

    更新日期:2016-01-01 00:00:00

  • Effects of potassium and sodium fluoride in different concentrations on micro-shear bond strength and inhibition of demineralization.

    abstract::The aim of this study was to investigate the effects of potassium fluoride (KF) and sodium fluoride (NaF) in different concentrations on micro-shear bond strength (µSBS) and their protective effects against acid. The enamel blocks were treated with several concentrations of KF and NaF. For µSBS, Clearfil SE Bond 2 was...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2020-019

    authors: Al-Qahtani A,Inoue G,Abdou A,Nikaido T,Tagami J

    更新日期:2020-10-27 00:00:00

  • Effect of Cr and Cu addition on corrosion behavior of Ni-Ti alloys.

    abstract::The corrosion behavior of three Ni-Ti alloys with compositions as commercial super-elastic orthodontic wires was investigated using polished plate specimens. Corrosion resistance was estimated by potentiodynamic polarization measurement in 0.9% NaCl and 1% lactic acid solutions and analysis of released metals by atomi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.31

    authors: Iijima M,Endo K,Ohno H,Mizoguchi I

    更新日期:1998-03-01 00:00:00

  • Multi-purpose bonding performance of newly synthesized phosphonic acid monomers.

    abstract::Multi-purpose bonding performance of three kinds of newly synthesized phosphonic acid monomers was investigated. Methacryloxyalkyl or acryloxyalkyl phosphonoacetates of 6-MHPA, 6-AHPA, 10-MDPA were synthesized in 42.8-51.9% yields with a light yellow viscous liquid, and identified as new compounds by 1H NMR, IR, and e...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.105

    authors: Ikemura K,Tay FR,Nishiyama N,Pashley DH,Endo T

    更新日期:2007-01-01 00:00:00