In vitro comparison of autoclave polymerization on the transverse strength of denture base resins.

Abstract:

:The aim of this study was to determine the effect of autoclave polymerization on the transverse strength of denture base polymers. To this end, 30 rectangular test specimens were fabricated of two heat-polymerized denture base polymers. The test groups were: (I) control, i.e., conventional water bath to polymerize resins by heat at 100 degrees C for 30 minutes; (II) autoclave polymerization at 60 degrees C for 30 minutes followed by 130 degrees C for 10 minutes; and (III) autoclave polymerization at 60 degrees C for 30 minutes followed by 130 degrees C for 20 minutes. The specimens were tested with three-point bending test at a crosshead speed of 5 mm/min. It was revealed that the transverse strength of specimens increased with statistical significance when the autoclave was used for polymerization.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Durkan R,Ozel MB,Bağiş B,Usanmaz A

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

640-2

issue

4

eissn

0287-4547

issn

1881-1361

journal_volume

27

pub_type

杂志文章
  • Characterization of 50wt%SiO2-20wt%P2O5-30wt%CaO glass-ceramic powders prepared by the sol-gel process.

    abstract::Glass-ceramic powders with the oxide batch formulation 50wt%SiO2, 20wt%P2O5 and 30wt%CaO were prepared by the sol-gel process using tetraethoxysilane, calcium nitrate and phosphoric acid as raw materials. The obtained gels and powders were characterized by TG-DTA thermal analysis, FTIR analyses and XRD measurements. T...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.16.117

    authors: Taira M,Okazaki M,Takahashi J

    更新日期:1997-12-01 00:00:00

  • Stress distribution in tooth resin core build-ups with different post-end positions in alveolar bone level under two kinds of load directions.

    abstract::This study aimed to evaluate influence of different post-end positions in alveolar bone level on stress distributions in resin-core build-up tooth under different load directions. Three-dimensional mathematical models of a root-filled mandibular premolar tooth were constructed. Resin post and core were built-up with s...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-160

    authors: Hatayama T,Chiba A,Kainose K,Nakajima M,Hosaka K,Wakabayashi N,Foxton RM,Tagami J

    更新日期:2018-06-08 00:00:00

  • Analysis of abutment tooth movement utilizing mandibular kinesiography (MKG). Part 2. Effects of clasp design in unilateral free-end denture.

    abstract::The three-dimensional dynamic movement of the abutment tooth was successfully analyzed on a simulation model utilizing the mandibular kinesiography. When the unilateral free-end denture retained by the RPA, RPI or Aker's clasp was subjected to various directions of loads, the abutment tooth was inclined mainly by the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.56

    authors: Morikawa M,Masumi S,Kido H,Toyoda S,Kozono Y

    更新日期:1989-06-01 00:00:00

  • Spectroscopic characterization of enamel surfaces irradiated with Er:YAG laser.

    abstract::The purpose of this study was to investigate the effect of laser irradiation on the enamel surface spectroscopically. Polished bovine enamel surface was irradiated with an Er:YAG laser apparatus and chemically analyzed using X-ray photoelectron spectroscopy (XPS). XPS detected core electron peaks such as carbon (C 1s)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.214

    authors: Mine A,Yoshida Y,Suzuki K,Nakayama Y,Yatani H,Kuboki T

    更新日期:2006-06-01 00:00:00

  • Chemical mechanical polishing of titanium with colloidal silica containing hydrogen peroxide--mirror polishing and surface properties.

    abstract::Chemical mechanical polishing (CMP) of cpTi (Ti) was carried out using two types of slurries, acidic and basic colloidal silica containing H2O2 up to 3 wt%, to obtain flat and mirror-polished surfaces without any contaminated and reacted layers. Polishing behavior and surface properties were investigated using AFM, EP...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.68

    authors: Okawa S,Watanabe K

    更新日期:2009-01-01 00:00:00

  • SEM observation of collagen fibrils secreted from the body surface of osteoblasts on a CO3apatite-collagen sponge.

    abstract::The secretion of collagen by osteoblasts was observed by scanning electron microscopy (SEM). Osteoblast-like cells were cultured on a CO3apatite-collagen sponge reinforced with a porous HAp frame. After three days' incubation, a number of newly created matrix fibrils, forming a network structure, were observed at the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.460

    authors: Hirata I,Nomura Y,Tabata H,Miake Y,Yanagisawa T,Okazaki M

    更新日期:2005-09-01 00:00:00

  • New partition technique for two-chamber pressure casting unit for titanium.

    abstract::Although titanium has been widely used in prosthetic appliances, such as cast removable partial denture frameworks, high quality castings are still difficult to obtain. This study proposes a new partition technique using a metal foil for improving castability of a two-chamber pressure casting unit. The metal foil was ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.307

    authors: Watanabe K,Okawa S,Kanatani M,Nakano S,Miyakawa O,Kobayashi M

    更新日期:2000-09-01 00:00:00

  • Hardness and Young's modulus of transparent dentin associated with aging and carious disease.

    abstract::This study investigated the changes in hardness and Young's modulus of the transparent layer of dentin associated with aging and the carious process. Eighteen extracted human molars with or without coronal caries were used in this study. The normal teeth were divided into two groups by age, and the carious teeth were ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.648

    authors: Zheng L,Nakajima M,Higashi T,Foxton RM,Tagami J

    更新日期:2005-12-01 00:00:00

  • Tensile bond strength of a lithium-disilicate pressed glass ceramic to dentin of different surface treatments.

    abstract::The effects of desensitizer, disinfectant, saliva, blood, and hydrogen peroxide on the tensile bond strength between adhesive and ceramic as well as between adhesive and dentin were examined. Sixty 7x3 mm pressed ceramic discs of IPS e.max were fabricated and randomly assigned to six groups of different dentin surface...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2009-074

    authors: Zortuk M,Kilic K,Gurbulak AG,Kesim B,Uctasli S

    更新日期:2010-08-01 00:00:00

  • Flexural properties of resin-modified "hybrid" glass-ionomers in comparison with conventional acid-base glass-ionomers.

    abstract::The mechanical properties of resin-modified "hybrid" glass-ionomers, for both restorative and liner/base applications, were assessed by a flexural test and compared with those of conventional acid-base glass-ionomers. Flexural strength, flexural modulus, and the modulus of resilience were determined 30 minutes after m...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.109

    authors: Momoi Y,Hirosaki K,Kohno A,McCabe JF

    更新日期:1995-12-01 00:00:00

  • Effects of polishing on surface roughness and hardness of glass-fiber-reinforced polypropylene.

    abstract::Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-012

    authors: Tanimoto Y,Nagakura M

    更新日期:2018-11-30 00:00:00

  • The protective effect of resveratrol against dentin bonding agents-induced cytotoxicity.

    abstract::This study was designed to evaluate the cytotoxicity of four dentin bonding agents and the effects of an antioxidant addition. Group A: G-aenial Bond, Group B: Optibond All in One, Group C: Gluma Self Etch and Group D: Clearfil S(3) Bond were added to the medium using extract method. The cells were cultured with or wi...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-079

    authors: Atalayin C,Armagan G,Konyalioglu S,Kemaloglu H,Tezel H,Ergucu Z,Keser A,Dagci T,Onal B

    更新日期:2015-01-01 00:00:00

  • A high-sensitive and non-radioisotopic fluorescence dye method for evaluating bacterial adhesion to denture materials.

    abstract::Oral bacteria adhered to dental material surfaces are known to cause various oral diseases. This study aimed to develop a highsensitive and non-radioisotopic fluorescence dye method for quantification of oral bacteria (Streptococcus, Actinomyces and Veillonella) adhered to denture material surfaces. The amount of adhe...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-060

    authors: Sakuma Y,Washio J,Sasaki K,Takahashi N

    更新日期:2013-01-01 00:00:00

  • Influence of abutment model materials on the fracture loads of three-unit fixed dental prostheses.

    abstract::This study evaluated and compared the influence of different supporting abutment models on the fracture loads of three-unit fixed dental prostheses (FDPs) fabricated from the following materials (n=24/material): (i) IPS e.max CAD-on, (ii) IPS e.max ZirCAD, and (iii) Telio CAD. Twelve FDPs of each group were adhesively...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-344

    authors: Wimmer T,Erdelt KJ,Eichberger M,Roos M,Edelhoff D,Stawarczyk B

    更新日期:2014-01-01 00:00:00

  • Calcium-ion incorporation into titanium surfaces accompanied by electrochemical apatite-deposition.

    abstract::The depths of calcium-ion incorporation into a commercially pure titanium and an experimental beta-type titanium alloy were determined using Auger electron spectroscopy. After the electrochemical deposition of apatite, new compositional gradients appeared in the profiles in which the Ca and P concentrations gradually ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.306

    authors: Ban S,Kamiya A,Sonoda T

    更新日期:2002-12-01 00:00:00

  • Modification of electrochemically deposited apatite using supercritical water.

    abstract::Supercritical water was used as a modification method of electrochemically deposited apatite on pure titanium. The apatites were coated on a commercially pure titanium plate using a hydrothermal-electrochemical method. A constant direct current at 12.5 mA/cm2 was loaded for 1 hr at 25, 60, 100, 150 and 200 degrees C i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.247

    authors: Ban S,Hasegawa J

    更新日期:2001-12-01 00:00:00

  • Comparative evaluation of various miniplate systems for the repair of mandibular corpus fractures.

    abstract::Miniplates have been used during the last decade to facilitate stability between bony fragments in the maxillofacial region and are currently the preferred surgical method for the fixation of fractures and osteotomies. The aim of this study was to evaluate and compare the biomechanical behaviors of six different types...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-315

    authors: Ergun S,Ofluoğlu D,Saruhanoğlu A,Karataşli B,Deniz E,Özel S,Tanyeri H

    更新日期:2014-01-01 00:00:00

  • Effect of thermocycling on the durability of etch-and-rinse and self-etch adhesives on dentin.

    abstract::The objective was to compare bond strengths of adhesives with/without thermocycling and to analyze the micromorphology of resindentin interfaces. Flat dentin surfaces were prepared and divided into eight groups to bond with four etch-and-rinse adhesives (Optibond FL, Adper Scotchbond Multi-Purpose, Optibond Solo Plus,...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-253

    authors: Sangwichit K,Kingkaew R,Pongprueksa P,Senawongse P

    更新日期:2016-01-01 00:00:00

  • Diametral tensile strength of novel fast-setting calcium silicate cement.

    abstract::Novel fast-setting calcium silicate cement with fluoride (CSC) has been developed for potential applications in tooth crown. The aim of this study was to test the diametral tensile strength (DTS) of different CSC compositions in humid condition on day1, 28, and 180. We tested 'bond CSC' with 3.5% fluoride and no radio...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-390

    authors: Ranjkesh B,Isidor F,Dalstra M,Løvschall H

    更新日期:2016-01-01 00:00:00

  • Mechanical properties and radiopacity of flowable fiber-reinforced composite.

    abstract::The aim was to evaluate the effect of different zirconia discontinuous fiber fractions on radiopacity and other selected properties of glass discontinuous fiber-reinforced flowable composite (Exp-SFRC). Exp-SFRC was prepared by mixing 30 wt% of resin-matrix and 45 wt% of particulate-fillers to 25 wt% of various weight...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-102

    authors: Garoushi S,Vallittu P,Lassila L

    更新日期:2019-03-31 00:00:00

  • Anisotropy of tensile strengths of bovine dentin regarding dentinal tubule orientation and location.

    abstract::The purpose of this study was to investigate the effects of the location and orientation of dentinal tubules in the tooth on tensile strengths of the dentin. Dumbbell-shaped specimens of 12 groups from various locations and dentinal tubule orientations were prepared. The tensile test was performed in distilled water a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.32

    authors: Inoue T,Takahashi H,Nishimura F

    更新日期:2002-03-01 00:00:00

  • High temperature characteristics and solidification microstructures of dental metallic materials. Part II. ADAS Type 3 gold alloy.

    abstract::Previously, high temperature properties of the silver-palladium-copper-gold alloy were investigated. In this study, the thermal expansion percentage and coefficient, and high temperature strengths of ADAS Type 3 gold alloy were investigated up to the liquidus temperature. Furthermore, microstructural and compositional...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.81

    authors: Nagasawa S,Yoshida T,Terashima N,Mizoguchi T,Yagasaki H,Kamijo K,Ito M,Platt JA,Oshida Y

    更新日期:2004-06-01 00:00:00

  • Pit and fissure nanocomposite sealants reinforced with organically modified montmorillonite: A study of their mechanical properties, surface roughness and color stability.

    abstract::The aim of the present work was to investigate the effect of the different organically modified nanoclays on clinically significant properties of new synthesized dental pit and fissure nanocomposite sealants. Their morphological characteristics were examined by means of X-ray diffraction (XRD) analysis and scanning el...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-214

    authors: Nikolaidis A,Vouzara T,Koulaouzidou E

    更新日期:2020-09-29 00:00:00

  • Surface properties and biocompatibility of acid-etched titanium.

    abstract::The purpose of this study was to evaluate the effects of acid-etched titanium on the biological responses of osteoblast-like MC3T3-E1 cells. Four types of treatments (polishing, sandblasting, concentrated H2SO4 etching, and concentrated H2SO4 etching with vacuum firing) were carried out on the surfaces of commercially...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.415

    authors: Iwaya Y,Machigashira M,Kanbara K,Miyamoto M,Noguchi K,Izumi Y,Ban S

    更新日期:2008-05-01 00:00:00

  • Influence of ultraviolet irradiation treatment on porcelain bond strength of titanium surfaces.

    abstract::To determine the effect of titanium (Ti) surface modification by ultraviolet irradiation (UVI) on the bond strength between Ti and porcelain. Grade 2 Ti plates were allotted to five groups: sandblasted (SA), 15 min UVI (UV), SA+5 min UVI (SA+UV5), SA+10 min UVI (SA+UV10), and SA+15 min UVI (SA+UV15). After surface tre...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-417

    authors: Kumasaka T,Ohno A,Hori N,Hoshi N,Maruo K,Kuwabara A,Seimiya K,Toyoda M,Kimoto K

    更新日期:2018-06-08 00:00:00

  • Effect of placement technique on the push-out bond strength of calcium-silicate based cements.

    abstract::The purpose of this study was to evaluate the effects of ultrasonic and manual placement techniques on the push-out bond strength of Biodentine and MTA with and without calcium chloride. One hundred and twenty mid-root slices from forty freshly extracted single-rooted human mandibular premolar teeth were instrumented ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-094

    authors: Küçükkaya Eren S,Aksel H,Serper A

    更新日期:2016-10-01 00:00:00

  • Antimicrobial effects of several calcium silicate-based root-end filling materials.

    abstract::The purpose of this study was to evaluate, in vitro, the antimicrobial effect of iRoot BP, iRoot BP Plus, and mineral trioxide aggregate (MTA) against Entercoccus faecalis and Candida albicans by using direct contact test. The materials were tested immediately after application to the microtiter wells and after settin...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-250

    authors: Damlar I,Ozcan E,Yula E,Yalcin M,Celik S

    更新日期:2014-01-01 00:00:00

  • Predicting in vivo failure of rotary nickel-titanium endodontic instruments under cyclic fatigue.

    abstract::The aim of this study was to examine the lifespan or number of cycles to failure of tapered rotary nickel-titanium (Ni-Ti) endodontic instruments. Simulated root canals with different curvatures were used to determine a relation between canal curvature and instrument lifespan. Using a novel mathematical model for the ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-254

    authors: Stojanac I,Drobac M,Petrovic L,Atanackovic T

    更新日期:2012-01-01 00:00:00

  • Development of cell-hybrid artificial bone: effect of osteogenic differentiation of bone marrow stromal stem cells on bone formation with newly developed interconnected porous calcium hydroxyapatite.

    abstract::The purpose of this study was to evaluate the effect of osteogenic differentiation of bone marrow stromal stem cells (BMSCs) on bone formation in a novel interconnected porous calcium hydroxyapatite (IP-CHA). BMSCs/IP-CHA composites, as a cell-hybrid artificial bone, were made by injecting BMSCs solution into IP-CHA s...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.162

    authors: Doi K,Kubo T,Hayashi K,Imura K,Akagawa Y

    更新日期:2007-03-01 00:00:00

  • Microtensile bond strengths of adhesively bonded polymer-based CAD/CAM materials to dentin.

    abstract::This in vitro study aimed to evaluate the effect of two different polymer-based CAD/CAM materials; resin-nano ceramic (Lava Ultimate [LVU]) and composite (CERASMART [CS]), their different surface pre-treatments, and use of different resin cements on the µTBS of adhesively bonded CAD/CAM onlays to dentin. CAD/CAM mater...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2017-442

    authors: Capa N,Say EC,Celebi C,Casur A

    更新日期:2019-02-08 00:00:00