Effect of thermocycling on the durability of etch-and-rinse and self-etch adhesives on dentin.

Abstract:

:The objective was to compare bond strengths of adhesives with/without thermocycling and to analyze the micromorphology of resindentin interfaces. Flat dentin surfaces were prepared and divided into eight groups to bond with four etch-and-rinse adhesives (Optibond FL, Adper Scotchbond Multi-Purpose, Optibond Solo Plus, and Single Bond 2) and four self-etch adhesives (Clearfil SE Bond, Adper SE Plus, Clearfil S(3) Bond and Adper Easy Bond). Specimens were further divided into two subgroups subjected for with/without thermocycling and then subjected to both micro-tensile test and resin-dentin interface evaluation. The results revealed that there were significant differences in bond strength between the groups with and without thermocycling for all etch-and-rinse groups and for the Adper Easy Bond self-etch group (p<0.01). Clearfil SE Bond demonstrated highly durable bond strengths. Furthermore, more silver ion uptake was observed at the resin-dentin interfaces for all etch-and-rinse adhesives and Adper SE Plus and Adper Easy Bond after thermocycling.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Sangwichit K,Kingkaew R,Pongprueksa P,Senawongse P

doi

10.4012/dmj.2015-253

subject

Has Abstract

pub_date

2016-01-01 00:00:00

pages

360-8

issue

3

eissn

0287-4547

issn

1881-1361

journal_volume

35

pub_type

杂志文章
  • Effect of experimental acid/base conditioner on microtensile bond strength of 4-META/MMA-TBB resin to dentin after long-term water immersion.

    abstract::An experimental conditioner (Exp), which was an aqueous solution of 10% ascorbic acid and 5% ferric chloride, was prepared in this study. This study evaluated the effect of Exp on the microtensile bond strength between a self-curing resin and dentin after long-term water immersion. Flat human dentin surfaces were sequ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-078

    authors: Soeno K,Taira Y,Ito S

    更新日期:2012-01-01 00:00:00

  • Cold plasma-induced surface modification of heat-polymerized acrylic resin and prevention of early adherence of Candida albicans.

    abstract::Atmospheric-pressure cold plasma was applied to process the surface of heat-polymerized acrylic resin. Changes to the physical properties and early adherence of Candida albicans were investigated. Alternating current cold plasma with Ar/O2 as working gas was used. Scanning electron microscopy (SEM) and X-ray photoelec...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-035

    authors: Pan H,Wang G,Pan J,Ye G,Sun K,Zhang J,Wang J

    更新日期:2015-01-01 00:00:00

  • Chemical structures of adhesion promoting monomers for precious metals and their bond strengths to dental metals.

    abstract::Adhesion promoting monomers for dental metals, 5-(4-vinylbenzyl)-2-thiobarbituric acid (5VS), 6- (4-vinylbenzyl-n-propyl) amino-1,3,5-triazine-2,4-dithione (VBATDT) and 9,10-epithiodecyl methacrylate (EP8MA), were synthesized and surface treatment agents were prepared by dissolving each monomer in ethanol or acetone. ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.343

    authors: Kadoma Y

    更新日期:2003-09-01 00:00:00

  • Shear bond strengths of a single-step bonding system to enamel and dentin.

    abstract::An experimental primer was developed as a single-step bonding system for resin-modified glass ionomer cements (GIC). Efficacy of this primer on adhesion of resin-modified GICs and resin composite to enamel and dentin was evaluated by shear bond test and SEM observation. Good bond strengths to enamel were obtained (> 1...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.16.40

    authors: Nikaido T,Nakajima M,Higashi T,Kanemura N,Pereira PN,Tagami J

    更新日期:1997-06-01 00:00:00

  • Effect of dentin cleansers on the bonding efficacy of dentin adhesive.

    abstract::The relation between the bonding efficacy of the dentin adhesive and the physical change of the dentin after treatment with various dentin cleansers was investigated. The dentin surface was cleaned with one of the seven experimental dentin cleansers, 5, 10, 20, 30 and 40% of the phosphoric acid, neutralized 0.5 M EDTA...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.76

    authors: Chiba M,Itoh K,Wakumoto S

    更新日期:1989-06-01 00:00:00

  • Retention force of complete palate coverage and palate-less dentures in vitro.

    abstract::The purpose of this study was to investigate the retention force of complete palate coverage and palate-less dentures made with three polymerization systems (DS system, SR-Ivocap system, microwave polymerization system) in vitro. The retention force between each denture and a polyurethane model by intervening artifici...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.19

    authors: Teraoka F,Nakagawa M,Takahashi J

    更新日期:2004-03-01 00:00:00

  • Synthesis of dimethacryloxy ethyl-1,1,6,6-tetrahydro-perfluorohexamethylene-1,6-dicarbamate as dental base monomers and the mechanical properties of the copolymers of the monomer and methyl methacrylate.

    abstract::To recognize good mechanical properties and water-resistance of a dental resin, dimethacryloxyethyl-1,1,6,6-tetrahydro-perfluoro-hexamethylene-1,6-dicarbamate (FDMHD) was newly synthesized. FDMHD initially was a white powder with m.p. 98.5-99.5°C. The copolymers of FDMHD and methyl methacrylate (MMA), FDMHD/MMA copoly...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-126

    authors: Kurata S,Yamazaki N

    更新日期:2011-01-01 00:00:00

  • Microhardness evaluation of resin composites polymerized by three different light sources.

    abstract::This study examined the surface microhardness of four kinds of resin composites with different fillers and resin matrices. Ten specimens of 2 mm thickness and 4 mm diameter of each resin composite were polymerized using a halogen light, a blue light-emitted diode, and a plasma arc unit. Microhardness evaluation was pe...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:

    authors: Hubbezoğlu I,Bolayir G,Doğan OM,Doğan A,Ozer A,Bek B

    更新日期:2007-11-01 00:00:00

  • Cytotoxic effects of contemporary bulk-fill dental composites: A real-time cell analysis.

    abstract::The aim of this study was to evaluate the cytotoxicity of contemporary flowable and paste-like bulk-fill dental composites by using a real-time cell analysis. In the present paper, cytotoxicity levels of five flowable, five paste-like bulk-fill composite materials and one conventional flowable, one conventional paste-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-336

    authors: Demirel G,Gür G,Demirsoy FF,Altuntaş EG,Yener-Ilce B,Kiliçarslan MA

    更新日期:2020-01-31 00:00:00

  • Effects of dental porcelain containing silver nanoparticles on static fatigue.

    abstract::The purpose of this study was to clarify the effect of silver nanoparticles on the behavior of subcritical crack growth (SCG) in dental porcelains. Prior to occurrence of fast fracture in dental porcelains, SCG occurs and leads to strength degradation over time. SCG in dental porcelains can be characterized by the str...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-266

    authors: Fujieda T,Uno M,Ishigami H,Kurachi M,Kamemizu H,Wakamatsu N,Doi Y

    更新日期:2013-01-01 00:00:00

  • Discoloration of manually fabricated resins and industrially fabricated CAD/CAM blocks versus glass-ceramic: effect of storage media, duration, and subsequent polishing.

    abstract::This study determined the discoloration of five CAD/CAM resins, four manually polymerized resins, and glass-ceramic as control group. Specimens were divided into three groups (N=300, n=30) to be stored in coffee, black tea and red wine (n=10). The discoloration was measured using a spectrophotometer after 1, 7, 29, 90...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-238

    authors: Stawarczyk B,Sener B,Trottmann A,Roos M,Ozcan M,Hämmerle CH

    更新日期:2012-01-01 00:00:00

  • Corrosion behavior of dental alloys coupled with titanium. Part 2. The area ratio dependence in five solutions.

    abstract::Sixteen alloys and five pure metals were used and the open circuit potentials (OCP) and the coupled potentials with titanium were measured in five kinds of solutions. All alloys and metals showed the maximum OCP in 1.3% lactic acid solution, and the minimum in 0.01% sodium sulfide solution. The coupled potential depen...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.20.75

    authors: Nakayama M,Ando N

    更新日期:2001-03-01 00:00:00

  • Degradation of dental ZrO2-based materials after hydrothermal fatigue. Part I: XRD, XRF, and FESEM analyses.

    abstract::The aim was to investigate the effect of simulated low-temperature degradation (s-LTD) and hydrothermal fatigue on the degradation of three ZrO(2)-based dental materials. Lava, IPS, and NanoZr discs were randomly assigned to (1) Control-Storage in distilled water at 37°C; (2) Aging at 134°C for 5 h (s-LTD); (3) Thermo...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-216

    authors: Perdigão J,Pinto AM,Monteiro RC,Braz Fernandes FM,Laranjeira P,Veiga JP

    更新日期:2012-01-01 00:00:00

  • A study of self-adhesive resin cements for bonding to silver-palladium-copper-gold alloy -- effect of including primer components in cement base.

    abstract::This study investigated the efficacies of adhesive resin cements (Clearfil SA Luting, Maxcem, G-CEM, RelyX Unicem Clicker, Vitremer Paste) for bonding to Ag-Pd-Cu-Au alloy not surface-pretreated with metal primer. For control, Panavia F 2.0 -developed for use with a proprietary metal primer, Alloy Primer- was tested w...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-093

    authors: Muraguchi K,Minami H,Minesaki Y,Suzuki S,Tanaka T

    更新日期:2011-01-01 00:00:00

  • Development of cell-hybrid artificial bone: effect of osteogenic differentiation of bone marrow stromal stem cells on bone formation with newly developed interconnected porous calcium hydroxyapatite.

    abstract::The purpose of this study was to evaluate the effect of osteogenic differentiation of bone marrow stromal stem cells (BMSCs) on bone formation in a novel interconnected porous calcium hydroxyapatite (IP-CHA). BMSCs/IP-CHA composites, as a cell-hybrid artificial bone, were made by injecting BMSCs solution into IP-CHA s...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.162

    authors: Doi K,Kubo T,Hayashi K,Imura K,Akagawa Y

    更新日期:2007-03-01 00:00:00

  • Evaluation of temperature changes in the pulp chamber during polymerization of light-cured pulp-capping materials by using a VALO LED light curing unit at different curing distances.

    abstract::The aim of this study was to evaluate temperature changes in the pulp chamber during polymerization of four different pulp-capping materials using a LED-light-curing-unit in the contact and noncontact positions. A pulpal circulation mechanism was simulated to measure increases in temperature in four pulp-capping mater...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-274

    authors: Savas S,Botsali MS,Kucukyilmaz E,Sari T

    更新日期:2014-01-01 00:00:00

  • Response of osteoblast-like cells to zirconia with different surface topography.

    abstract::The objective of this study was to clarify the effect of surface topography on osteoblast-like cell behavior on yttria stabilized tetragonal zirconia polycrystals (TZP). Mirror-polished; blasted with 50- or 150-µm alumina (SB50 and SB150); and SB150 acid-etched with hydrofluoric acid (SB150E) were prepared on TZP. Ini...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-208

    authors: Ito H,Sasaki H,Saito K,Honma S,Yajima Y,Yoshinari M

    更新日期:2013-01-01 00:00:00

  • Influence of ultraviolet irradiation treatment on porcelain bond strength of titanium surfaces.

    abstract::To determine the effect of titanium (Ti) surface modification by ultraviolet irradiation (UVI) on the bond strength between Ti and porcelain. Grade 2 Ti plates were allotted to five groups: sandblasted (SA), 15 min UVI (UV), SA+5 min UVI (SA+UV5), SA+10 min UVI (SA+UV10), and SA+15 min UVI (SA+UV15). After surface tre...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-417

    authors: Kumasaka T,Ohno A,Hori N,Hoshi N,Maruo K,Kuwabara A,Seimiya K,Toyoda M,Kimoto K

    更新日期:2018-06-08 00:00:00

  • Effects of a barbituric acid/CuCl2 initiator system on resin adhesion to dentin.

    abstract::The effectiveness of a barbituric acid/copper (II) chloride initiator system in dentin was examined in terms of the effects of barbituric acid structures and dentin conditioners on bond strength. Curing times and tensile bond strengths to bovine dentin were measured for PMMA/MMA resins in conjunction with initiators c...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.221

    authors: Suzuki A,Imai Y

    更新日期:1995-12-01 00:00:00

  • Anisotropy of tensile strengths of bovine dentin regarding dentinal tubule orientation and location.

    abstract::The purpose of this study was to investigate the effects of the location and orientation of dentinal tubules in the tooth on tensile strengths of the dentin. Dumbbell-shaped specimens of 12 groups from various locations and dentinal tubule orientations were prepared. The tensile test was performed in distilled water a...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.32

    authors: Inoue T,Takahashi H,Nishimura F

    更新日期:2002-03-01 00:00:00

  • Correlation in the mechanical properties of acrylic denture base resins.

    abstract::The aim of the present study was to measure various mechanical properties of acrylic denture base resins, including flexural modulus, flexural strength, fracture toughness, Barcol and Vickers hardness and their related properties, and to investigate correlations between different mechanical properties. Resin specimens...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-205

    authors: Lee HH,Lee CJ,Asaoka K

    更新日期:2012-02-03 00:00:00

  • Self-cleaning ability of a photocatalyst-containing denture base material.

    abstract::This study examined the ability of a photocatalyst mixed in a denture base resin to decompose organic substances which adhered to the denture base resin surface. The photocatalyst was mixed with denture base resin at concentrations of 0, 5, 10, and 15% (w/w). Decomposition test, bending test, and surface roughness mea...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.179

    authors: Cheng Y,Sakai T,Moroi R,Nakagawa M,Sakai H,Ogata T,Terada Y

    更新日期:2008-03-01 00:00:00

  • Changes on NiTi orthodontic wired due to acidic fluoride solution.

    abstract::The effect of acidic fluoride solution on NiTi arch wires was examined by testing crystal structure, tensile strength, morphology after fracture, and element release from wire under four different test solutions after 1 or 3 d immersion. Three-day immersion in a 0.2%/pH 4 solution did not form any new crystal structur...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.557

    authors: Kwon YH,Cheon YD,Seol HJ,Lee JH,Kim HI

    更新日期:2004-12-01 00:00:00

  • Effect of surface preparation on the bond strength of heat-polymerized denture base resin to commercially pure titanium and cobalt-chromium alloy.

    abstract::The aim of this study was to investigate the bond durability of heat-polymerized denture base resin to cast CP Ti and Co-Cr alloy. The alloy specimens were divided into five groups: 1) airborne-particle abraded with 50 µm alumina (SAND), 2) Rocatec tribochemical silica coating system (RO), 3) air-abraded followed by a...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2010-089

    authors: Kawaguchi T,Shimizu H,Lassila LV,Vallittu PK,Takahashi Y

    更新日期:2011-01-01 00:00:00

  • Microtensile bond strength of a newly developed resin cement to dentin.

    abstract::The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a newly developed resin cement, ECD-89 (ECD, Tokuyama Dental, Tokyo, Japan) to dentin and to observe the interfacial micromorphology by comparing with two commercial resin cements, Multilink Automix (MA, Ivoclar Vivadent AG, Schaan, Lie...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2014-122

    authors: Kawano S,Fu J,Saikaew P,Chowdhury AA,Fukuzawa N,Kadowaki Y,Kakuda S,Hoshika S,Nakaoki Y,Ikeda T,Tanaka T,Sano H

    更新日期:2015-01-01 00:00:00

  • Effects of incorporation of nano-fluorapatite particles on microhardness, fluoride releasing properties, and biocompatibility of a conventional glass ionomer cement (GIC).

    abstract::Present study evaluated effects of addition of Nanoparticles fluorapatite (Nano-FA) on microhardness and fluoride release of a Glass Ionomer Cement (GIC, Fuji IX GP Fast). Forty-eight specimens prepared, divided equally into 4 groups (2 with Nano-FA); after 24 h and one week Vickers microhardness (HV) was measured. Na...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2015-437

    authors: Moshaverinia M,Borzabadi-Farahani A,Sameni A,Moshaverinia A,Ansari S

    更新日期:2016-01-01 00:00:00

  • CAD/CAM-fabricated inlay restorations: Can the resin-coating technique improve bond strength and internal adaptation?

    abstract::This study assessed the effect of the resin-coating technique on the bond strength and internal adaptation of computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated inlays. Seventy-two mesio-occlusal-distal (MOD) cavities were prepared and distributed into 3 groups according to the resin-coating techn...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2019-309

    authors: Rozan S,Takahashi R,Nikaido T,Tichy A,Tagami J

    更新日期:2020-12-03 00:00:00

  • Type I collagen grafting on titanium surfaces using low-temperature glow discharge.

    abstract::To improve the bioactivity of titanium surfaces, glow discharge was used to facilitate collagen grafting on titanium disks. Titanium test specimens were pre-treated by glow discharge fed with a mixture of argon and allylamine (AA) gases. Treated titanium disks were then grafted with type I collagen using glutaraldehyd...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.340

    authors: Chang WJ,Ou KL,Lee SY,Chen JY,Abiko Y,Lin CT,Huang HM

    更新日期:2008-05-01 00:00:00

  • Effect of placement technique on the push-out bond strength of calcium-silicate based cements.

    abstract::The purpose of this study was to evaluate the effects of ultrasonic and manual placement techniques on the push-out bond strength of Biodentine and MTA with and without calcium chloride. One hundred and twenty mid-root slices from forty freshly extracted single-rooted human mandibular premolar teeth were instrumented ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-094

    authors: Küçükkaya Eren S,Aksel H,Serper A

    更新日期:2016-10-01 00:00:00

  • Effect of sodium hypochlorite contamination on microhardness of dental core build-up materials.

    abstract::This study aimed to determine the influence of sodium hypochlorite (NaOCl) contamination on the microhardness of build-up composites. Fifty-two samples, from each of three build-up materials (LuxaCore Dual, MultiCore flow and Rebilda DC) were prepared. Half of the samples from each material were stored in physiologic ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2010-007

    authors: Wegehaupt FJ,Betschart J,Attin T

    更新日期:2010-08-01 00:00:00