Perfusion imaging using dynamic arterial spin labeling (DASL).

Abstract:

:Recently, a technique based on arterial spin labeling, called dynamic arterial spin labeling (DASL (Magn Reson Med 1999;41:299-308)), has been introduced to measure simultaneously the transit time of the labeled blood from the labeling plane to the exchange site, the longitudinal relaxation time of the tissue, and the perfusion of the tissue. This technique relies on the measurement of the tissue magnetization response to a time varying labeling function. The analysis of the characteristics of the tissue magnetization response (transit time, filling time constant, and perfusion) allows for quantification of the tissue perfusion and for transit time map computations. In the present work, the DASL scheme is used in conjunction with echo planar imaging at 4.7 T to produce brain maps of perfusion and transit time in the anesthetized rat, under graded hypercapnia. The data obtained show the variation of perfusion and transit time as a function of arterial pCO2. Based on the data, CO2 reactivity maps are computed. Published 2001 Wiley-Liss, Inc.

journal_name

Magn Reson Med

authors

Barbier EL,Silva AC,Kim SG,Koretsky AP

doi

10.1002/mrm.1136

subject

Has Abstract

pub_date

2001-06-01 00:00:00

pages

1021-9

issue

6

eissn

0740-3194

issn

1522-2594

pii

10.1002/mrm.1136

journal_volume

45

pub_type

杂志文章
  • Super-resolution for upper abdominal MRI: Acquisition and post-processing protocol optimization using brain MRI control data and expert reader validation.

    abstract:PURPOSE:Magnetic resonance (MR) cholangiopancreatography (MRCP) is an established specialist method for imaging the upper abdomen and biliary/pancreatic ducts. Due to limitations of either MR image contrast or low through-plane resolution, patients may require further evaluation with contrast-enhanced computed tomograp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27852

    authors: Ebner M,Patel PA,Atkinson D,Caselton L,Firmin L,Amin Z,Bainbridge A,De Coppi P,Taylor SA,Ourselin S,Chouhan MD,Vercauteren T

    更新日期:2019-11-01 00:00:00

  • Uncovering of intracellular water in cultured cells.

    abstract::The complexity of biologic tissues, with multiple compartments each with its own diffusion and relaxation properties, requires complex formalisms to model water signal in most magnetic resonance imaging or magnetic resonance spectroscopy experiments. In this article, we describe a magnetic susceptibility-induced shift...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20565

    authors: Galons JP,Lope-Piedrafita S,Divijak JL,Corum C,Gillies RJ,Trouard TP

    更新日期:2005-07-01 00:00:00

  • Bayesian multipoint velocity encoding for concurrent flow and turbulence mapping.

    abstract::An approach to efficiently measure three-dimensional velocity vector fields and turbulent kinetic energy of blood flow is presented. Multipoint phase-contrast imaging is used in combination with Bayesian analysis to map both mean and fluctuating velocities over a large dynamic range and for practically relevant signal...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24370

    authors: Binter C,Knobloch V,Manka R,Sigfridsson A,Kozerke S

    更新日期:2013-05-01 00:00:00

  • Three-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain.

    abstract::Diffusion tensor imaging is gaining increasing importance for anatomical imaging of the developing mouse brain. However, the application of diffusion tensor imaging to mouse brain imaging at microscopic levels is hindered by the limitation on achievable spatial resolution. In this study, fast diffusion tensor microima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22426

    authors: Aggarwal M,Mori S,Shimogori T,Blackshaw S,Zhang J

    更新日期:2010-07-01 00:00:00

  • Imaging of single human carcinoma cells in vitro using a clinical whole-body magnetic resonance scanner at 3.0 T.

    abstract::The purpose of the present study was to examine whether single human carcinoma cells labeled with iron oxide nanoparticles could be detected by magnetic resonance (MR) imaging on a clinical 3-T scanner using a surface coil only. WiDr human colon carcinoma cells were loaded with two kinds of iron oxide nanoparticles di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20455

    authors: Pinkernelle J,Teichgräber U,Neumann F,Lehmkuhl L,Ricke J,Scholz R,Jordan A,Bruhn H

    更新日期:2005-05-01 00:00:00

  • Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload.

    abstract:PURPOSE:MR-based quantification of liver magnetic susceptibility may enable field strength-independent measurement of liver iron concentration (LIC). However, susceptibility quantification is challenging, due to nonlocal effects of susceptibility on the B0 field. The purpose of this work is to demonstrate feasibility o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24848

    authors: Hernando D,Cook RJ,Diamond C,Reeder SB

    更新日期:2013-09-01 00:00:00

  • Quantification of regional blood volumes by rapid T1 mapping.

    abstract::A new method is presented for the quantitative determination of regional blood volumes in vivo. It is based on rapid quantitative T1 mapping by Snapshot FLASH MRI combined with the injection of an intravascular MR contrast agent. Regional blood volumes in four different tissues of the rat (skeletal muscle, heart, live...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290521

    authors: Schwarzbauer C,Syha J,Haase A

    更新日期:1993-05-01 00:00:00

  • Optimization of survey protocols for MRI.

    abstract::A method for evaluating the sensitivity of MRI protocols to changes in an arbitrary number of tissue parameters over a broad range of parameter values is presented. This analysis is useful for choosing an optimal basis set of images for either a "survey" protocol or tissue segmentation algorithms. A survey protocol is...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910130202

    authors: McVeigh ER,Henkelman RM,Bronskill MJ

    更新日期:1990-02-01 00:00:00

  • Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method.

    abstract::The Shinnar-Le Roux (SLR) radiofrequency (RF) pulse design algorithm is widely used for designing slice-selective RF pulses due to its intuitiveness, optimality, and speed. SLR is limited, however, in that it is only capable of designing one-dimensional pulses played along constant gradients. We present a nonuniform S...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23269

    authors: Grissom WA,McKinnon GC,Vogel MW

    更新日期:2012-09-01 00:00:00

  • A pitfall associated with determination of transverse relaxation times of the 31P NMR signals of ATP using the Hahn spin-echo.

    abstract::T2 measurements of 31P NMR signals of ATP using the Hahn 90 degrees-180 degrees spin-echo sequence imply difficulties whenever the 180 degrees pulse angle is not completely perfect. The reason for this finding is the crucial influence of the J-couplings of the ATP signals which result in intensity modulations and cons...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300122

    authors: Jung WI,Straubinger K,Bunse M,Widmaier S,Schick F,Küper K,Dietze G,Lutz O

    更新日期:1993-07-01 00:00:00

  • Fast Fourier imaging.

    abstract::A new NMR imaging technique, aiming at a reduction of the data acquisition time, is described in detail. The method is applicable in all multidimensional imaging situations where at least one spatial coordinate is resolved. Discussed at some length are the point-spread function, the required bandwidth of the NMR spect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020304

    authors: van Uijen CM,den Boef JH,Verschuren FJ

    更新日期:1985-06-01 00:00:00

  • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

    abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21614

    authors: Leupold J,Hennig J,Scheffler K

    更新日期:2008-07-01 00:00:00

  • High-resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch.

    abstract::Genetically engineered mouse models provide enormous potential for investigation of the underlying mechanisms of atherosclerotic disease, but noninvasive imaging methods for analysis of atherosclerosis in mice are currently limited. This study aimed to demonstrate the feasibility of MRI to noninvasively visualize athe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10500

    authors: Wiesmann F,Szimtenings M,Frydrychowicz A,Illinger R,Hunecke A,Rommel E,Neubauer S,Haase A

    更新日期:2003-07-01 00:00:00

  • Flow velocity measurement with ac gradients.

    abstract::Two NMR experiments are described that use ac field gradients to measure flow velocities. Both experiments perform no spacial localization; instead, fluid velocity is converted to a resonance frequency shift. Thus, by Fourier transformation of a single FID or echo train the distribution of velocities is available. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040308

    authors: Walton JH,Conradi MS

    更新日期:1987-03-01 00:00:00

  • x-f Choice: reconstruction of undersampled dynamic MRI by data-driven alias rejection applied to contrast-enhanced angiography.

    abstract::A technique for reconstructing dynamic undersampled MRI data, termed "x-f choice," was developed and applied to dynamic contrast-enhanced MR angiography (DCE-MRA). Regular undersampling in k-t space (a hybrid of k-space and time) creates aliasing in the conjugate x-f space that must be resolved. When regions in the ob...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21008

    authors: Malik SJ,Schmitz S,O'Regan D,Larkman DJ,Hajnal JV

    更新日期:2006-10-01 00:00:00

  • Volumetric navigators for real-time motion correction in diffusion tensor imaging.

    abstract::Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel techn...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23314

    authors: Alhamud A,Tisdall MD,Hess AT,Hasan KM,Meintjes EM,van der Kouwe AJ

    更新日期:2012-10-01 00:00:00

  • Robust diffusion tensor imaging by spatiotemporal encoding: Principles and in vivo demonstrations.

    abstract:PURPOSE:Evaluate the usefulness of single-shot and of interleaved spatiotemporally encoded (SPEN) methods to perform diffusion tensor imaging (DTI) under various preclinical and clinical settings. METHODS:A formalism for analyzing SPEN DTI data is presented, tailored to account for the spatially dependent b-matrix wei...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26197

    authors: Solomon E,Liberman G,Nissan N,Frydman L

    更新日期:2017-03-01 00:00:00

  • SSFP signal with finite RF pulses.

    abstract::The theoretical description of steady state free precession (SSFP) sequences is generally well accepted and unquestioned, although it is based on instantaneously acting radiofrequency (RF) pulses. In practice, however, all excitation processes are finite, thereby questioning the overall validity of the common SSFP sig...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22116

    authors: Bieri O,Scheffler K

    更新日期:2009-11-01 00:00:00

  • A 1H-NMR method for determining temperature in cell culture perfusion systems.

    abstract::This report describes a noninvasive 1H-NMR method for measuring absolute temperatures (+/- 0.2 degrees C) in biological samples and, in particular, in cell culture perfusion systems, utilizing the linear temperature dependence of the water chemical shift relative to the temperature-independent shift of one of the comp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290120

    authors: Lutz NW,Kuesel AC,Hull WE

    更新日期:1993-01-01 00:00:00

  • Trajectory optimization based on the signal-to-noise ratio for spatial encoding with nonlinear encoding fields.

    abstract:PURPOSE:Multiple nonlinear gradient fields offer many potential benefits for spatial encoding including reduced acquisition time, fewer artefacts and region-specific imaging, although designing a suitable trajectory for such a setup is difficult. This work aims to optimize encoding trajectories for multiple nonlinear g...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25859

    authors: Layton KJ,Kroboth S,Jia F,Littin S,Yu H,Zaitsev M

    更新日期:2016-07-01 00:00:00

  • Magnetic resonance imaging of blood vessels at high fields: in vivo and in vitro measurements and image simulation.

    abstract::Unusually high image contrast in vivo magnetic resonance imaging of the brain becomes observable at high magnetic fields when the blood oxygenation level is lowered. The cause of the contrast has been attributed to a magnetic susceptibility effect induced by paramagnetic deoxyhemoglobin in red cells. When the cylinder...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910160103

    authors: Ogawa S,Lee TM

    更新日期:1990-10-01 00:00:00

  • Comparison between simulated decoupling regimes for specific absorption rate prediction in parallel transmit MRI.

    abstract:PURPOSE:The use of electromagnetic (EM) modeling is critical for specific absorption rate (SAR) characterization in parallel transmission MRI. Radiofrequency arrays that include decoupling networks can be difficult to characterize accurately in simulation. A practical method of simplifying modeling is to exclude the de...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25504

    authors: Beqiri A,Hand JW,Hajnal JV,Malik SJ

    更新日期:2015-11-01 00:00:00

  • Sensitivity regularization of the Cramér-Rao lower bound to minimize B1 nonuniformity effects in quantitative magnetization transfer imaging.

    abstract:PURPOSE:To develop and validate a regularization approach of optimizing B1 insensitivity of the quantitative magnetization transfer (qMT) pool-size ratio (F). METHODS:An expression describing the impact of B1 inaccuracies on qMT fitting parameters was derived using a sensitivity analysis. To simultaneously optimize fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27337

    authors: Boudreau M,Pike GB

    更新日期:2018-12-01 00:00:00

  • View-ordering in radial fast spin-echo imaging.

    abstract::Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20031

    authors: Theilmann RJ,Gmitro AF,Altbach MI,Trouard TP

    更新日期:2004-04-01 00:00:00

  • Unifying linear prior-information-driven methods for accelerated image acquisition.

    abstract::In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1242

    authors: Tsao J,Behnia B,Webb AG

    更新日期:2001-10-01 00:00:00

  • Sampling errors in projection reconstruction MRI.

    abstract::Certain kinds of artifacts have been reported when projection reconstruction (PR) techniques are used in magnetic resonance imaging (MRI). These will occur if the spacing between samples in k-space is too large. It has been suggested that PR requires finer k-space sampling than does two-dimensional Fourier reconstruct...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400317

    authors: Joseph PM

    更新日期:1998-09-01 00:00:00

  • Algorithms for extracting motion information from navigator echoes.

    abstract::Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360120

    authors: Wang Y,Grimm RC,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1996-07-01 00:00:00

  • Extended graphical model for analysis of dynamic contrast-enhanced MRI.

    abstract::Kinetic analysis with mathematical models has become increasingly important to quantify physiological parameters in computed tomography (CT), positron emission tomography (PET), and dynamic contrast-enhanced MRI (DCE-MRI). The modified Kety/Tofts model and the graphical (Patlak) model have been widely applied to DCE-M...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22819

    authors: Chen H,Li F,Zhao X,Yuan C,Rutt B,Kerwin WS

    更新日期:2011-09-01 00:00:00

  • Uniform spinning sampling gradient electron paramagnetic resonance imaging.

    abstract:PURPOSE:To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition. THEORY AND METHODS:A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24712

    authors: Johnson DH,Ahmad R,Liu Y,Chen Z,Samouilov A,Zweier JL

    更新日期:2014-02-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00