Abstract:
:A technique for reconstructing dynamic undersampled MRI data, termed "x-f choice," was developed and applied to dynamic contrast-enhanced MR angiography (DCE-MRA). Regular undersampling in k-t space (a hybrid of k-space and time) creates aliasing in the conjugate x-f space that must be resolved. When regions in the object containing fast dynamic change are sparse, as in DCE-MRA, signal overlap caused by aliasing is often much less than the undersample factor would imply. x-f Choice reconstruction identifies overlapping signals using a model of the full non-aliased x-f space that is automatically generated from the undersampled data, and applies parallel imaging (PI) to separate them. No extra reference scans are required to generate either the model or the coil sensitivity maps. At each location in the reconstructed images, g-factor noise amplification is compared with predicted reconstruction errors to obtain an optimized solution. Acceleration factors greater than the number of receiver coils are possible, but are limited by the sparseness of the dynamic content and the signal-to-noise ratio (SNR) (in DCE-MRA the latter is dominant). Temporal fidelity was validated for up to a factor 10 speed-up using retrospectively undersampled data from a six-coil array. The method was tested on volunteers using fivefold prospective undersampling.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Malik SJ,Schmitz S,O'Regan D,Larkman DJ,Hajnal JVdoi
10.1002/mrm.21008subject
Has Abstractpub_date
2006-10-01 00:00:00pages
811-23issue
4eissn
0740-3194issn
1522-2594journal_volume
56pub_type
杂志文章abstract::Pulsed arterial spin labeling (ASL) techniques provide a noninvasive method of obtaining qualitative and quantitative perfusion images with MRI. ASL techniques employ inversion recovery and/or saturation recovery to induce perfusion weighting, and thus the performance of these techniques is dependent on the slice prof...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1169
更新日期:2001-07-01 00:00:00
abstract::Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21514
更新日期:2008-07-01 00:00:00
abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20848
更新日期:2006-05-01 00:00:00
abstract::The soft tissue contrast obtained in fast imaging using rapidly repeated partial saturation sequences is usually based on differences in T1. We describe here an extension of the method which results in the development of clinically useful T2-based contrast. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910040404
更新日期:1987-04-01 00:00:00
abstract:PURPOSE:Recent literature shows that diffusion tensor properties can be estimated more accurately with diffusion kurtosis imaging (DKI) than with diffusion tensor imaging (DTI). Furthermore, the additional non-Gaussian diffusion features from DKI can be sensitive markers for tissue characterization. Despite these benef...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25165
更新日期:2015-02-01 00:00:00
abstract::Parallel imaging presents a promising approach for MRI of hyperpolarized nuclei, as the penalty in signal-to-noise ratio typically encountered with (1)H MRI due to a reduction in acquisition time can be offset by an increase in flip angle. The signal-to-noise ratio of hyperpolarized MRI generally exhibits a strong dep...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22962
更新日期:2011-12-01 00:00:00
abstract:PURPOSE:Over the last two decades, extended criteria have promoted an increased number of donor livers available for liver transplantation. But posttransplant graft loss is still a major concern. Macrovesicular hepatic steatosis (MHS) is recognized as the most significant prognostic histologic parameter in predicting p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28592
更新日期:2020-11-16 00:00:00
abstract:PURPOSE:Fourier decomposition (FD) is a noninvasive method for assessing ventilation and perfusion-related information in the lungs. However, the technique has a low signal-to-noise ratio (SNR) in the lung parenchyma. We present an approach to increase the SNR in both morphological and functional images. METHODS:The d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25293
更新日期:2015-05-01 00:00:00
abstract::Experiments were performed to determine whether changes in T2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recyc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330306
更新日期:1995-03-01 00:00:00
abstract::Metallic particles have shaped the use of magnetic resonance imaging (MRI) for molecular and cellular imaging. Although these particles have generally been developed for extracellular residence, either as blood pool contrast agents or targeted contrast agents, the coopted use of these particles for intracellular label...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,评审
doi:10.1002/mrm.25263
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:To optimize and investigate the influence of bipolar gradients for flow suppression in metabolic quantification of hyperpolarized 13 C chemical shift imaging (CSI) of mouse liver at 9.4 T. METHODS:The trade-off between the amount of flow suppression using bipolar gradients and T2* effect from static spins was ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26578
更新日期:2017-11-01 00:00:00
abstract:PURPOSE:To improve the imaging quality of vessel walls with an endoesophageal Wireless Amplified NMR Detector (WAND). METHODS:A cylindrically shaped double-frequency resonator has been constructed with a single metal wire that is self-connected by a pair of nonlinear capacitors. The double-frequency resonator can conv...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26562
更新日期:2017-11-01 00:00:00
abstract::This study investigates the potential of in vivo 31P magnetic resonance spectroscopy (MRS) to characterize musculoskeletal tumors and to determine preoperative levels of histological necrosis, which is an important clinical indicator of patient response. Pretherapy MRS was performed on 28 patients with large musculosk...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910270204
更新日期:1992-10-01 00:00:00
abstract::Golgi impregnation is unique in its ability to display the dendritic trees and axons of large numbers of individual neurons by histology. Here we apply magnetic resonance microscopy to visualize the neuroanatomy of animal models by combining histologic fixation chemistry with paramagnetic contrast agents. Although the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22322
更新日期:2010-05-01 00:00:00
abstract:PURPOSE:To propose a phase error correction scheme for monopolar time-interleaved multi-echo gradient echo water-fat imaging that allows accurate and robust complex-based quantification of the proton density fat fraction (PDFF). METHODS:A three-step phase correction scheme is proposed to address a) a phase term induce...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26485
更新日期:2017-09-01 00:00:00
abstract:PURPOSE:To study the feasibility of black-blood contrast in native T1 mapping for reduction of partial voluming at the blood-myocardium interface. METHODS:A saturation pulse prepared heart-rate-independent inversion recovery (SAPPHIRE) T1 mapping sequence was combined with motion-sensitized driven-equilibrium (MSDE) b...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26378
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:The heterogeneous tumor cell population and dynamic microenvironment within a tumor lead to regional variations in cell proliferation, migration, and differentiation. In this work, MRI and optical projection tomography were used to examine and compare the redistribution of a cellular label in two mouse glioma m...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24790
更新日期:2014-04-01 00:00:00
abstract::An automatic fMRI protocol for the investigation of the human auditory cortex has been developed. For the activation of the auditory system, the scanner noise itself is the source of sound. Rapid switching of B0 gradients allows the generation of tones of defined frequencies and amplitude on a conventional scanner wit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910400621
更新日期:1998-12-01 00:00:00
abstract:PURPOSE:To investigate and compare several quantification methods of myocardial perfusion measurements, paying special attention to the relation between the techniques and the required measurement duration. METHODS:Seven patients underwent contrast-enhanced rest and stress cardiac perfusion measurements at 3T. Three s...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,随机对照试验
doi:10.1002/mrm.25212
更新日期:2015-03-01 00:00:00
abstract:PURPOSE:Dipole antennas in ultrahigh field MRI have demonstrated advantages over more conventional designs. In this study, the fractionated dipole antenna is presented: a dipole where the legs are split into segments that are interconnected by capacitors or inductors. METHODS:A parameter study has been performed on di...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25596
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To develop a novel analytical method for quantification of chemical exchange saturation transfer (CEST) in the transient state. The proposed method aims to reduce the effects of non-chemical-exchange (non-CE) parameters on the CEST signal, emphasizing the effect of chemical exchange. METHODS:The difference in ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26559
更新日期:2017-11-01 00:00:00
abstract::A MultiEcho Segmented EPI with z-shimmed BAckground gradient Compensation (MESBAC) pulse sequence is proposed and validated for functional MRI (fMRI) study in regions suffering from severe susceptibility artifacts. This sequence provides an effective tradeoff between spatial and temporal resolution and reduces image d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10219
更新日期:2002-08-01 00:00:00
abstract::Metallic implants, such as stents, have long been a concern in magnetic resonance imaging (MRI). In addition to safety issues, they are commonly associated with image artifacts. The mechanisms of radiofrequency- (RF) and susceptibility-induced artifacts have been thoroughly investigated. However, gradient-switching-in...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20294
更新日期:2004-12-01 00:00:00
abstract:PURPOSE:To quantify chemical exchange saturation transfer contrast in upper extremities of participants with lymphedema before and after standardized lymphatic mobilization therapy using correction procedures for B0 and B1 heterogeneity, and T1 relaxation. METHODS:Females with (n = 12) and without (n = 17) breast canc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28031
更新日期:2020-05-01 00:00:00
abstract:PURPOSE:To develop and validate closed form mathematical expressions that predict the optimal contrast agent concentration for the maximum T1-weighted spoiled gradient echo (SGRE) signal. THEORY AND METHODS:Gadolinium and iron-based contrast agents can have significant transverse relaxivity that leads to signal dropou...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25744
更新日期:2016-04-01 00:00:00
abstract::The proton T(1) was measured at 132 μT in ex vivo prostate tissue specimens from radical prostatectomies of 35 patients with prostate cancer. Each patient provided two specimens. The NMR and MRI measurements involved proton repolarization, a field of typically 150 mT and detection of the 5.6-kHz signal with a supercon...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24177
更新日期:2012-04-01 00:00:00
abstract:PURPOSE:To assess the feasibility of using dissolved hyperpolarized xenon-129 (129 Xe) MRI to study renal physiology in humans at 3 T. METHODS:Using a flexible transceiver RF coil, dynamic and spatially resolved 129 Xe spectroscopy was performed in the abdomen after inhalation of hyperpolarized 129 Xe gas with 3 healt...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27923
更新日期:2020-01-01 00:00:00
abstract::Time-resolved three-dimensional phase-contrast MRI is an important tool for physiological as well as clinical studies of blood flow in the heart and vessels. The application of the technique is, however, limited by the long scan times required. In this work, we investigate the feasibility of using spiral readouts to r...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23297
更新日期:2012-10-01 00:00:00
abstract::An in vitro study was performed to investigate the effects of B(o) inhomogeneity on magnetic resonance images of flow. Controlled inhomogeneity gradients (Gi) were applied and the magnitude of the artifacts produced was quantified for different echo delay times (TE). Both steady and pulsatile flows were examined. In t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910350116
更新日期:1996-01-01 00:00:00
abstract::A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24137
更新日期:2012-03-01 00:00:00