Abstract:
:Parallel imaging presents a promising approach for MRI of hyperpolarized nuclei, as the penalty in signal-to-noise ratio typically encountered with (1)H MRI due to a reduction in acquisition time can be offset by an increase in flip angle. The signal-to-noise ratio of hyperpolarized MRI generally exhibits a strong dependence on flip angle, which makes a homogeneous B(1)(+) transmit field desirable. This paper presents a flexible 32-channel receive array for (3) He human lung imaging at 1.5T designed for insertion into an asymmetric birdcage transmit coil. While the 32-channel array allows parallel imaging at high acceleration factors, the birdcage transmit coil provides a homogeneous B(1)(+) field. Decoupling between array elements is achieved by using a concentric shielding approach together with preamplifier decoupling. Coupling between transmit coil and array elements is low by virtue of a low geometric coupling coefficient, which is reduced further by the concentric shields in the array. The combination of the 32-channel array and birdcage transmit coil provides (3)He ventilation images of excellent quality with similar signal-to-noise ratio at acceleration factors R = 2 and R = 4, while maintaining a homogeneous B(1)(+).
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Deppe MH,Parra-Robles J,Marshall H,Lanz T,Wild JMdoi
10.1002/mrm.22962subject
Has Abstractpub_date
2011-12-01 00:00:00pages
1788-97issue
6eissn
0740-3194issn
1522-2594journal_volume
66pub_type
杂志文章abstract::How stem cells promote myocardial repair in myocardial infarction (MI) is not well understood. The purpose of this study was to noninvasively monitor and quantify mesenchymal stem cells (MSC) from bone marrow to MI sites using magnetic resonance imaging (MRI). MSC were dual-labeled with an enhanced green fluorescent p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22735
更新日期:2011-05-01 00:00:00
abstract::Volume-localized proton NMR spectroscopy was used to estimate bone marrow cellularity in the posterior iliac crests of patients undergoing treatment with hematopoietic growth factors for a variety of hematologic and neoplastic disorders. Twelve patients were accrued, six of whom were studied more than once, yielding a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910190108
更新日期:1991-05-01 00:00:00
abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,评审
doi:10.1002/mrm.28471
更新日期:2021-01-01 00:00:00
abstract::Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imagin...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22413
更新日期:2010-06-01 00:00:00
abstract:PURPOSE:At high field, T2 -weighted (T2 w) imaging is limited by transmit field inhomogeneity and increased radiofrequency power deposition. In this work, we introduce SAMPA (Slice-selective Adiabatic Magnetization T2 PrepAration) and demonstrate its use for efficient brain T2 w imaging at 7 Tesla (T). METHODS:SAMPA w...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26067
更新日期:2016-12-01 00:00:00
abstract:PURPOSE:Oscillating gradient (OG) enables the access of short diffusion times for time-dependent diffusion MRI (dMRI); however, it poses several technical challenges for clinical use. This study proposes a 3D oscillating gradient-prepared gradient spin-echo (OGprep-GRASE) sequence to improve SNR and shorten acquisition...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28401
更新日期:2021-01-01 00:00:00
abstract::A receive-only phased-array coil was designed to image the lower extremities. The array consists of four volume coils placed on two cylindrical formers. The coil array has the ability to image both legs simultaneously over a 40 cm longitudinal field of view (FOV). Experiments using phantoms show an increase in signal-...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10712
更新日期:2004-03-01 00:00:00
abstract::A partial saturation method is described for obtaining rapid images of tissue 1H spin-lattice relaxation rates following administration of the paramagnetic contrast agent gadolinium-diethylenetriaminepentaacetate. The paramagnetic contribution to the relaxation rates is proportional to the concentration of contrast ag...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910310308
更新日期:1994-03-01 00:00:00
abstract::Cerebral metabolite concentrations and water content were measured by means of localized proton magnetic resonance spectroscopy in 50 children, while metabolite peak ratios in short echo time spectra were evaluated in 173 examinations. Normative curves for normal development were established for two cerebral locations...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910300405
更新日期:1993-10-01 00:00:00
abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>
更新日期:2000-03-01 00:00:00
abstract:PURPOSE:To develop a novel, simultaneous multislice reconstruction method that exploits Hankel subspace learning (SMS-HSL) for aliasing separation in the slice direction. METHODS:An SMS signal model with the Hankel-structured matrix was proposed. To efficiently suppress interslice leakage artifacts from a signal subsp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26527
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:A new method, called Transmit and Receive Patterns from Low-Tip-angle gradient-Echo Images (TRIPLET), is described which simultaneously maps the B1+ and B1- fields of a transmit/receive radiofrequency coil array. The input data are low-tip-angle gradient-echo images, which can be acquired in a relatively short ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24912
更新日期:2014-07-01 00:00:00
abstract::A new NMR parameter is suggested as a sensitive tool for monitoring thermal coagulation of liver tissue. That parameter is the proton magnetization exchange time (tau(MEX)) between water and the proteins. tau(MEX) was very sensitive to coagulation and insensitive to temperature, therefore representing only damage to t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20693
更新日期:2005-11-01 00:00:00
abstract::High-order radiofrequency transmitter coils are described that permit, in the context of NMR imaging, a knowledgeable trade-off between coil complexity and the degree of inhomogeneity over a specified volume of space. A mathematical formulation of high-order coils is developed for an axially symmetric polarizing dc fi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030108
更新日期:1986-02-01 00:00:00
abstract::Proton T(1rho)-dispersion MRI is demonstrated for indirect, in vivo detection of (17)O in the brain. This technique, which may be readily implemented on any clinical MRI scanner, is applied towards high-resolution, quantitative mapping of cerebral blood flow (CBF) in the rat by monitoring the clearance of (17)O-enrich...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10403
更新日期:2003-03-01 00:00:00
abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21095
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:Golden-angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k-space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP recon...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27030
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:The purpose of this project was to construct a physical brain phantom for MRI, mimicking structure and T1 relaxation properties of white matter (WM) and gray matter (GM). METHODS:The phantom design comprised 2 compartments, 1 resembling the WM and 1 resembling the GM. Their T1 relaxation times, as assessed usi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27464
更新日期:2019-02-01 00:00:00
abstract::Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real-time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21044
更新日期:2006-11-01 00:00:00
abstract::Gradient-recalled echo-planar (T2*-weighted) imaging was used to noninvasively monitor regional blood oxygenation state changes in real time during transient episodes of focal ischemia in cat brain. Varying ischemic intervals (12 s to 30 min) were caused by middle cerebral artery occlusion. A rapid signal drop was not...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910270220
更新日期:1992-10-01 00:00:00
abstract::The goal of this study was to measure the interindividual reproducibility of glutamate quantification in 1.5-T (1)H MRS of human brains. To determine the effective echo time (TE) for glutamate quantification, spectra from a phantom and 12 participants were obtained with TE = 30, 35, 40, and 144 ms (repetition time (TR...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20387
更新日期:2005-03-01 00:00:00
abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25262
更新日期:2015-04-01 00:00:00
abstract::Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200003)43:3<459::aid-mrm19
更新日期:2000-03-01 00:00:00
abstract::We improved the three-point phase-contrast method by regularization of MR velocity data after acquisition of a low velocity-to-noise ratio (VNR) velocity image and a high VNR aliased velocity image. The phase unwrapping algorithm is based on the assumed correlation of the velocity of adjacent flow voxels on the low VN...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200007)44:1<122::aid-mrm18>3.0.c
更新日期:2000-07-01 00:00:00
abstract::The selective multiple-quantum coherence transfer method has been applied to image polyunsaturated fatty acids (PUFA) distributions in human breast tissues in vivo for cancer detection, with complete suppression of the unwanted lipid and water signals in a single scan. The Cartesian k-space mapping of PUFA in vivo usi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22901
更新日期:2012-01-01 00:00:00
abstract::Formation of ternary complexes between Gd-DTPA, Gd-DTPA-BMA, and Gd-DOTA, used as contrast enhancement agents in MRI and the endogenously available carbonate and phosphate ions, has been demonstrated. The extent of ternary complex formation and its effect on the proton relaxation, measured at 9 MHz, rates is negligibl...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910380120
更新日期:1997-07-01 00:00:00
abstract:PURPOSE:We aimed to develop a novel free-breathing cardiac diffusion tensor MRI (DT-MRI) approach, M2-MT-MOCO, capable of whole left ventricular coverage that leverages second-order motion compensation (M2) diffusion encoding and multitasking (MT) framework to efficiently correct for respiratory motion (MOCO). METHODS...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28611
更新日期:2020-11-30 00:00:00
abstract:PURPOSE:To develop a fully automated trajectory and gradient waveform design for the non-Cartesian shells acquisition, and to develop a magnetization-prepared (MP) shells acquisition to achieve an efficient three-dimensional acquisition with improved gray-to-white brain matter contrast. METHODS:After reviewing the she...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26863
更新日期:2018-04-01 00:00:00
abstract:PURPOSE:To characterize and optimize 19 F MRI for different perfluorocarbons (PFCs) at 3T and quantify the loss of acquisition efficiency as a function of different temperature and cellular conditions. METHODS:The T1 and T2 relaxation times of the commonly used PFCs perfluoropolyether (PFPE), perfluoro-15-crown-5-ethe...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26317
更新日期:2017-06-01 00:00:00
abstract:PURPOSE:To determine whether neurochemical concentrations obtained at two MRI sites using clinical 3T scanners can be pooled when a highly optimized, nonvendor short-echo, single-voxel proton MRS pulse sequence is used in conjunction with identical calibration and quantification procedures. METHODS:A modified semi-LAS...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25295
更新日期:2015-05-01 00:00:00