Characterization of perfluorocarbon relaxation times and their influence on the optimization of fluorine-19 MRI at 3 tesla.

Abstract:

PURPOSE:To characterize and optimize 19 F MRI for different perfluorocarbons (PFCs) at 3T and quantify the loss of acquisition efficiency as a function of different temperature and cellular conditions. METHODS:The T1 and T2 relaxation times of the commonly used PFCs perfluoropolyether (PFPE), perfluoro-15-crown-5-ether (PFCE), and perfluorooctyl bromide (PFOB) were measured in phantoms and in several different conditions (cell types, presence of fixation agent, and temperatures). These relaxation times were used to optimize pulse sequences through numerical simulations. The acquisition efficiency in each cellular condition was then determined as the ratio of the signal after optimization with the reference relaxation times and after optimization with its proper relaxation times. Finally, PFC detection limits were determined. RESULTS:The loss of acquisition efficiency due to parameter settings optimized for the wrong temperature and cellular condition was limited to 13%. The detection limits of all PFCs were lower at 24 °C than at 37 °C and varied from 11.8 ± 3.0 mM for PFCE at 24 °C to 379.9 ± 51.8 mM for PFOB at 37 °C. CONCLUSION:Optimizing 19 F pulse sequences with a known phantom only leads to moderate loss in acquisition efficiency in cellular conditions that might be encountered in in vivo and in vitro experiments. Magn Reson Med 77:2263-2271, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

journal_name

Magn Reson Med

authors

Colotti R,Bastiaansen JAM,Wilson A,Flögel U,Gonzales C,Schwitter J,Stuber M,van Heeswijk RB

doi

10.1002/mrm.26317

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

2263-2271

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

77

pub_type

杂志文章
  • Piezoelectric-controlled tuning capacitor for surface coils.

    abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120106

    authors: Hyde JS,Rilling RJ,Jesmanowicz A,Kneeland JB

    更新日期:1989-10-01 00:00:00

  • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

    abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29

    authors: Wood JC,Johnson KM

    更新日期:1999-03-01 00:00:00

  • Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

    abstract:PURPOSE:Establishing a high-resolution non-ECG-gated first-pass perfusion (FPP) cardiac MRI technique may improve accessibility and diagnostic capability of FPP imaging. We propose a non-ECG-gated FPP imaging technique using continuous magnetization-driven golden-angle radial acquisition. The main purpose of this preli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25074

    authors: Sharif B,Dharmakumar R,Arsanjani R,Thomson L,Bairey Merz CN,Berman DS,Li D

    更新日期:2014-12-01 00:00:00

  • Dynamic slice-dependent shim and center frequency update in 3 T breast diffusion weighted imaging.

    abstract:PURPOSE:To demonstrate dynamic slice-dependent shim update as a simple method to reduce susceptibility-induced B0 inhomogeneity and associated pixel shift artifacts in diffusion-weighted echo planar imaging (DW-EPI) in 3 T breast imaging. METHODS:Dynamic slice-dependent update of linear shim and center frequency was i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24824

    authors: Lee SK,Tan ET,Govenkar A,Hancu I

    更新日期:2014-05-01 00:00:00

  • Assessing transneuronal dysfunction utilizing manganese-enhanced MRI (MEMRI).

    abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21648

    authors: Serrano F,Deshazer M,Smith KD,Ananta JS,Wilson LJ,Pautler RG

    更新日期:2008-07-01 00:00:00

  • Specific absorption rate benefits of including measured electric field interactions in parallel excitation pulse design.

    abstract::Specific absorption rate management and excitation fidelity are key aspects of radiofrequency pulse design for parallel transmission at ultra-high magnetic field strength. The design of radiofrequency pulses for multiple channels is often based on the solution of regularized least-squares optimization problems for whi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23004

    authors: Deniz CM,Alon L,Brown R,Sodickson DK,Zhu Y

    更新日期:2012-01-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • Susceptibility mapping in the human brain using threshold-based k-space division.

    abstract::A method for calculating quantitative three-dimensional susceptibility maps from field measurements acquired using gradient echo imaging at high field is presented. This method is based on division of the three-dimensional Fourier transforms of high-pass-filtered field maps by a simple function that is the Fourier tra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22334

    authors: Wharton S,Schäfer A,Bowtell R

    更新日期:2010-05-01 00:00:00

  • Lung imaging under free-breathing conditions.

    abstract::Respiratory motion and pulsatile blood flow can generate artifacts in morphological and functional lung imaging. Total acquisition time, and thus the achievable signal to noise ratio, is limited when performing breath-hold and/or electrocardiogram-triggered imaging. To overcome these limitations, imaging during free r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21846

    authors: Oechsner M,Pracht ED,Staeb D,Arnold JF,Köstler H,Hahn D,Beer M,Jakob PM

    更新日期:2009-03-01 00:00:00

  • Indirect 17(O)-magnetic resonance imaging of cerebral blood flow in the rat.

    abstract::Proton T(1rho)-dispersion MRI is demonstrated for indirect, in vivo detection of (17)O in the brain. This technique, which may be readily implemented on any clinical MRI scanner, is applied towards high-resolution, quantitative mapping of cerebral blood flow (CBF) in the rat by monitoring the clearance of (17)O-enrich...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10403

    authors: Tailor DR,Roy A,Regatte RR,Charagundla SR,McLaughlin AC,Leigh JS,Reddy R

    更新日期:2003-03-01 00:00:00

  • Spatial-frequency-tuned markers and adaptive correction for rotational motion.

    abstract::A common type of motion present in clinical magnetic resonance imaging examinations is rotational motion, such as that due to voluntary motion during head examinations. The correction scheme presented in this work offers a method for eliminating the effects of rotations within the imaging plane. Integral to the implem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330511

    authors: Korin HW,Felmlee JP,Riederer SJ,Ehman RL

    更新日期:1995-05-01 00:00:00

  • Q-space truncation and sampling in diffusion spectrum imaging.

    abstract:PURPOSE:To characterize the q-space truncation and sampling on the spin-displacement probability density function (PDF) in diffusion spectrum imaging (DSI). METHODS:DSI data were acquired using the MGH-USC connectome scanner (Gmax  = 300 mT/m) with bmax  = 30,000 s/mm2 , 17 × 17 × 17, 15 × 15 × 15 and 11 × 11 × 11 gri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26071

    authors: Tian Q,Rokem A,Folkerth RD,Nummenmaa A,Fan Q,Edlow BL,McNab JA

    更新日期:2016-12-01 00:00:00

  • Identification of a characteristic 31P NMR signal in acute experimental pancreatitis with the aid of 1H-31P correlated 2D measurements of intact pancreas.

    abstract::Two-dimensional 1H-31P correlation spectroscopy and relaxation time measurements of intact diseased pancreas were performed in order to identify an unknown peak appearing at -0.18 +/- 0.04 ppm in a 31P NMR spectrum of taurocholate-induced experimental acute pancreatitis in rats. The signal was identified as a solubili...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910100111

    authors: Kushnir T,Kaplan O,Askenasy N,Navon G

    更新日期:1989-04-01 00:00:00

  • Impact of signal-to-noise on functional MRI.

    abstract::Functional magnetic resonance imaging (fMRI) has recently been adopted as an investigational tool in the field of neuroscience. The signal changes induced by brain activations are small ( approximately 1-2%) at 1.5T. Therefore, the signal-to-noise ratio (SNR) of the time series used to calculate the functional maps is...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200012)44:6<925::aid-mrm14>3.0.c

    authors: Parrish TB,Gitelman DR,LaBar KS,Mesulam MM

    更新日期:2000-12-01 00:00:00

  • Fast maximum intensity projection algorithm using shear warp factorization and reduced resampling.

    abstract::Maximal intensity projection (MIP) is routinely used to view MRA and other volumetric angiographic data. The straightforward implementation of MIP is ray casting that traces a volumetric data set in a computationally expensive manner. This article reports a fast MIP algorithm using shear warp factorization and reduced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10114

    authors: Fang L,Wang Y,Qiu B,Qian Y

    更新日期:2002-04-01 00:00:00

  • A pitfall associated with lactate detection using stimulated-echo proton spectroscopy.

    abstract::At TE values of 136 ms, it has recently been shown that the lactate methyl signal, when obtained with a stimulated-echo (STE) sequence, is modulated at the zero-quantum (ZQ) frequency when TM is varied. Here we describe an additional modulation of the ZQ lactate signal, due to spin-spin coupling, that results in a 10-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170223

    authors: Sotak CH,Alger JR

    更新日期:1991-02-01 00:00:00

  • Cocaine administration decreases functional connectivity in human primary visual and motor cortex as detected by functional MRI.

    abstract::Functional magnetic resonance imaging (fMRI) was conducted to observe the effects of cocaine administration on the physiological fluctuations of fMRI signal in two brain regions. Seven long-term cocaine users with an average age of 32 years and 8 years of cocaine use history were recruited for the study. A T2*-weighte...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<45::aid-mrm6>3

    authors: Li SJ,Biswal B,Li Z,Risinger R,Rainey C,Cho JK,Salmeron BJ,Stein EA

    更新日期:2000-01-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • On the application of ultra-fast RARE experiments.

    abstract::The ultra-fast application of the RARE experiment is described in detail, with special emphasis on its multifarious applications with preparation experiments that produce transverse magnetization. The factors affecting the temporal evolution of the magnetization during the experiment are described, and the implication...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270114

    authors: Norris DG,Börnert P,Reese T,Leibfritz D

    更新日期:1992-09-01 00:00:00

  • The flip-angle effect: a method for detection of sodium-23 quadrupole splitting in tissue.

    abstract::A method is presented for the detection of quadrupole splitting in tissue, where the spectral line splittings are typically unobservable. The method used is a study of the rate of rotation of the flip angle as a function of radiofrequency (rf) amplitude. Our results with samples of skeletal muscle and cat brain indica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040108

    authors: Joseph PM,Summers RM

    更新日期:1987-01-01 00:00:00

  • Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRI.

    abstract:PURPOSE:To investigate the influence of transcytolemmal water exchange on estimates of tissue microstructural parameters derived from diffusion MRI using conventional PGSE and IMPULSED methods. METHODS:Computer simulations were performed to incorporate a broad range of intracellular water life times τin (50-∞ ms), cel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26309

    authors: Li H,Jiang X,Xie J,Gore JC,Xu J

    更新日期:2017-06-01 00:00:00

  • Diffusional kurtosis imaging: the quantification of non-gaussian water diffusion by means of magnetic resonance imaging.

    abstract::A magnetic resonance imaging method is presented for quantifying the degree to which water diffusion in biologic tissues is non-Gaussian. Since tissue structure is responsible for the deviation of water diffusion from the Gaussian behavior typically observed in homogeneous solutions, this method provides a specific me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20508

    authors: Jensen JH,Helpern JA,Ramani A,Lu H,Kaczynski K

    更新日期:2005-06-01 00:00:00

  • Analysis and correction of biases in cross-relaxation MRI due to biexponential longitudinal relaxation.

    abstract:PURPOSE:Cross-relaxation imaging (CRI) is a family of quantitative magnetization transfer techniques that utilize images obtained with off-resonance saturation and longitudinal relaxation rate (R1) maps reconstructed by the variable flip angle (VFA) method. It was demonstrated recently that a significant bias in an app...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24677

    authors: Mossahebi P,Yarnykh VL,Samsonov A

    更新日期:2014-02-01 00:00:00

  • Global and peak local specific absorption rate control on parallel transmit systems using k-means SAR compression model.

    abstract:PURPOSE:To improve the specific absorption rate (SAR) compression model capability in parallel transmission (pTx) MRI systems. METHODS:A k-means clustering method is proposed to group voxels with similar SAR behaviors in the scanned object, providing a controlled upper-bounded estimation of peak local SARs. This k-mea...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28456

    authors: Mao X,Bari S,Love DJ,Rispoli JV

    更新日期:2021-02-01 00:00:00

  • T2 measurement in articular cartilage: impact of the fitting method on accuracy and precision at low SNR.

    abstract::T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal-to-noise ratio of images available from clinical examinations. The purpose of this work was to assess the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22178

    authors: Raya JG,Dietrich O,Horng A,Weber J,Reiser MF,Glaser C

    更新日期:2010-01-01 00:00:00

  • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging.

    abstract::Radiofrequency (RF) -spoiled gradient echo sequences were developed with the aim to produce images with T(1) weighted contrast within short acquisition time. Over the past two decades, this type of sequence has proven to be a robust technique and represents a reliable workhorse in clinical MRI. This study presents an ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21614

    authors: Leupold J,Hennig J,Scheffler K

    更新日期:2008-07-01 00:00:00

  • Optimized 3D ultrashort echo time pulmonary MRI.

    abstract:PURPOSE:To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS:3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise pe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24570

    authors: Johnson KM,Fain SB,Schiebler ML,Nagle S

    更新日期:2013-11-01 00:00:00

  • Complete elimination of the extracellular 23Na NMR signal in triple quantum filtered spectra of rat hearts in the presence of shift reagents.

    abstract::A method is suggested whereby the shifted extracellular triple quantum filtered 23Na signal of an isolated organ is completely eliminated. The method is based on the long relaxation time of the triple quantum coherence and on its fast evolution rate. When the carrier frequency is set on top of the intracellular sodium...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300415

    authors: Navon G

    更新日期:1993-10-01 00:00:00

  • Multi-turn transmit coil to increase b1 efficiency in current source amplification.

    abstract:PURPOSE:A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS:Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24612

    authors: Gudino N,Griswold MA

    更新日期:2013-04-01 00:00:00

  • "PINOT": time-resolved parallel magnetic resonance imaging with a reduced dynamic field of view.

    abstract::This article introduces a novel method named "Parallel Imaging and Noquist in Tandem" (PINOT) for accelerated image acquisition of cine cardiac magnetic resonance imaging. This method combines two prior information formalisms, the SPACE-RIP implementation of parallel imaging and the Noquist method for reduced-data ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22696

    authors: Hamilton LH,Fabregat JA,Moratal D,Ramamurthy S,Lerakis S,Parks WJ,Sallee D 3rd,Brummer ME

    更新日期:2011-04-01 00:00:00