Identification of a characteristic 31P NMR signal in acute experimental pancreatitis with the aid of 1H-31P correlated 2D measurements of intact pancreas.

Abstract:

:Two-dimensional 1H-31P correlation spectroscopy and relaxation time measurements of intact diseased pancreas were performed in order to identify an unknown peak appearing at -0.18 +/- 0.04 ppm in a 31P NMR spectrum of taurocholate-induced experimental acute pancreatitis in rats. The signal was identified as a solubilized lecithin taurocholate complex.

journal_name

Magn Reson Med

authors

Kushnir T,Kaplan O,Askenasy N,Navon G

doi

10.1002/mrm.1910100111

subject

Has Abstract

pub_date

1989-04-01 00:00:00

pages

119-24

issue

1

eissn

0740-3194

issn

1522-2594

journal_volume

10

pub_type

杂志文章
  • Motion correction in fMRI via registration of individual slices into an anatomical volume.

    abstract::An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired in the same fMRI ses...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<964::aid-mrm16

    authors: Kim B,Boes JL,Bland PH,Chenevert TL,Meyer CR

    更新日期:1999-05-01 00:00:00

  • Interventional MR elastography for MRI-guided percutaneous procedures.

    abstract:PURPOSE:MRI-guided thermal ablations require reliable monitoring methods to ensure complete destruction of the diseased tissue while avoiding damage to the surrounding healthy tissue. Based on the fact that thermal ablations result in substantial changes in biomechanical properties, interventional MR elastography (MRE)...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25694

    authors: Corbin N,Vappou J,Breton E,Boehler Q,Barbé L,Renaud P,de Mathelin M

    更新日期:2016-03-01 00:00:00

  • Mapping of redox status in a brain-disease mouse model by three-dimensional EPR imaging.

    abstract::Electron paramagnetic resonance imaging using nitroxides is a powerful method for visualizing the redox status modulated by oxidative stress in vivo. Typically, however, data acquisition times have been too slow to obtain a sufficient number of projections for three-dimensional images, when using continuous wave-elect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22598

    authors: Fujii H,Sato-Akaba H,Kawanishi K,Hirata H

    更新日期:2011-01-01 00:00:00

  • Inverse reconstruction method for segmented multishot diffusion-weighted MRI with multiple coils.

    abstract::Each k-space segment in multishot diffusion-weighted MRI is affected by a different spatially varying phase which is caused by unavoidable motions and amplified by the diffusion-encoding gradients. A proper image reconstruction therefore requires phase maps for each segment. Such maps are commonly derived from two-dim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22126

    authors: Uecker M,Karaus A,Frahm J

    更新日期:2009-11-01 00:00:00

  • Simultaneous image acquisition from the head (or body) coil and a surface coil.

    abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060212

    authors: Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

    更新日期:1988-02-01 00:00:00

  • Flow-suppressed hyperpolarized 13 C chemical shift imaging using velocity-optimized bipolar gradient in mouse liver tumors at 9.4 T.

    abstract:PURPOSE:To optimize and investigate the influence of bipolar gradients for flow suppression in metabolic quantification of hyperpolarized 13 C chemical shift imaging (CSI) of mouse liver at 9.4 T. METHODS:The trade-off between the amount of flow suppression using bipolar gradients and T2* effect from static spins was ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26578

    authors: Lee H,Lee J,Joe E,Yang S,Song JE,Choi YS,Wang E,Joo CG,Song HT,Kim DH

    更新日期:2017-11-01 00:00:00

  • Quantification of punctate iron sources using magnetic resonance phase.

    abstract::Iron-mediated tissue damage is present in cerebrovascular and neurodegenerative diseases and neurotrauma. Brain microbleeds are often present in these maladies and are assuming increasing clinical importance. Because brain microbleeds present a source of pathologic iron to the brain, the noninvasive quantification of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22185

    authors: McAuley G,Schrag M,Sipos P,Sun SW,Obenaus A,Neelavalli J,Haacke EM,Holshouser B,Madácsi R,Kirsch W

    更新日期:2010-01-01 00:00:00

  • The field dependence of NMR imaging. II. Arguments concerning an optimal field strength.

    abstract::Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal-to-noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information avail...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030509

    authors: Hoult DI,Chen CN,Sank VJ

    更新日期:1986-10-01 00:00:00

  • Sensitivity enhancement and reduction of Gibbs artifact in T2-weighted imaging using variable tip angle excitation.

    abstract::Introduction of a Gaussian weighting function into the phase encoding of the spin-echo imaging method via variable tip angle excitation, with concomitant optimization of the recycle delay, is shown to increase the sensitivity of T2-weighted imaging by up to 40%. In addition, the Gibbs artifact associated with sharp bo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910210216

    authors: Webb AG,Clarkson RB

    更新日期:1991-10-01 00:00:00

  • Imaging of single human carcinoma cells in vitro using a clinical whole-body magnetic resonance scanner at 3.0 T.

    abstract::The purpose of the present study was to examine whether single human carcinoma cells labeled with iron oxide nanoparticles could be detected by magnetic resonance (MR) imaging on a clinical 3-T scanner using a surface coil only. WiDr human colon carcinoma cells were loaded with two kinds of iron oxide nanoparticles di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20455

    authors: Pinkernelle J,Teichgräber U,Neumann F,Lehmkuhl L,Ricke J,Scholz R,Jordan A,Bruhn H

    更新日期:2005-05-01 00:00:00

  • Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    abstract:PURPOSE:To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS:Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27177

    authors: Fyrdahl A,Vargas Paris R,Nyrén S,Holst K,Ugander M,Lindholm P,Sigfridsson A

    更新日期:2018-11-01 00:00:00

  • Modulation of the pharmacokinetics of macromolecular contrast material by avidin chase: MRI, optical, and inductively coupled plasma mass spectrometry tracking of triply labeled albumin.

    abstract::The goal of this work was to develop an MRI method for mapping the clearance of interstitial macromolecular plasma proteins after their extravasation from permeable blood vessels. To that end, a well-defined window of exposure to elevated blood levels was generated by inducing rapid clearance of macromolecular contras...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10638

    authors: Dafni H,Gilead A,Nevo N,Eilam R,Harmelin A,Neeman M

    更新日期:2003-11-01 00:00:00

  • Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

    abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10358

    authors: Kim J,Prince MR,Zabih R,Bezanson J,Watts R,Erel HE,Wang Y

    更新日期:2002-12-01 00:00:00

  • Direct imaging of hyperpolarized 129Xe alveolar gas uptake in a mouse model of emphysema.

    abstract::MRI of hyperpolarized (129)Xe dissolved in pulmonary tissues, and blood has the potential to offer a new tool for regional evaluation of pulmonary gas exchange and perfusion; however, the extremely short T2* and low magnetization density make it difficult to acquire the image. In this study, an ultrashort echo-time se...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24452

    authors: Iguchi S,Imai H,Hori Y,Nakajima J,Kimura A,Fujiwara H

    更新日期:2013-07-01 00:00:00

  • Dual-polarity slice-GRAPPA for concurrent ghost correction and slice separation in simultaneous multi-slice EPI.

    abstract:PURPOSE:A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultane...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27113

    authors: Hoge WS,Setsompop K,Polimeni JR

    更新日期:2018-10-01 00:00:00

  • Group sparse reconstruction using intensity-based clustering.

    abstract::Compressed sensing has been of great interest to speed up the acquisition of MR images. The k-t group sparse (k-t GS) method has recently been introduced for dynamic MR images to exploit not just the sparsity, as in compressed sensing, but also the spatial group structure in the sparse representation. k-t GS achieves ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24333

    authors: Prieto C,Usman M,Wild JM,Kozerke S,Batchelor PG,Schaeffter T

    更新日期:2013-04-01 00:00:00

  • Real-time dynamic frequency and shim correction for single-voxel magnetic resonance spectroscopy.

    abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24129

    authors: Keating B,Ernst T

    更新日期:2012-11-01 00:00:00

  • TOWERS: T-One with Enhanced Robustness and Speed.

    abstract:PURPOSE:A new T1 mapping method is proposed that is accurate, rapid, and robust to motion. Considering these features, the method is dubbed "T-One with Enhanced Robustness and Speed (TOWERS)." METHODS:TOWERS is composed of inversion recovery (IR) and saturation recovery (SR) acquisitions. In the IR acquisitions, a sli...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25864

    authors: Eldeniz C,Finsterbusch J,Lin W,An H

    更新日期:2016-07-01 00:00:00

  • Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition.

    abstract::Dynamic susceptibility contrast (DSC) MRI is now increasingly used for measuring perfusion in many different applications. The quantification of DSC data requires the measurement of the arterial input function (AIF) and the deconvolution of the tissue concentration time curve. One of the most accepted deconvolution me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.c

    authors: Calamante F,Gadian DG,Connelly A

    更新日期:2000-09-01 00:00:00

  • Resolution-recovery for EPR imaging of free radical molecules in mice.

    abstract::A method of post-processing to enhance the image resolution of the distribution of free radical molecules obtained with continuous-wave electron paramagnetic resonance (CW-EPR) imaging is reported. The low spatial resolution of EPR imaging, which has created difficulties in biomedical applications, was overcome by the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22029

    authors: Ikebata Y,Sato-Akaba H,Aoyama T,Fujii H,Itoh K,Hirata H

    更新日期:2009-09-01 00:00:00

  • Real-time Triggered RAdial Single-Shot Inversion recovery for arrhythmia-insensitive myocardial T1 mapping: motion phantom validation and in vivo comparison.

    abstract:PURPOSE:Cardiac T1 mapping has become an increasingly important imaging technique, contributing novel diagnostic options. However, currently utilized methods are often associated with accuracy problems because of heart rate variations and cardiac arrhythmia, limiting their value in clinical routine. This study aimed to...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27526

    authors: Gensler D,Salinger T,Düring M,Lorenz K,Jahns R,Wech T,Frantz S,Ertl G,Jakob PM,Nordbeck P

    更新日期:2019-03-01 00:00:00

  • Quantification of vessel wall motion and cyclic strain using cine phase contrast MRI: in vivo validation in the porcine aorta.

    abstract::Artery wall motion and strain play important roles in vascular remodeling and may be important in the pathogenesis of vascular disease. In vivo observations of circumferentially nonuniform wall motion in the human aorta suggest that nonuniform strain may contribute to the localization of vascular pathology. A velocity...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20137

    authors: Draney MT,Arko FR,Alley MT,Markl M,Herfkens RJ,Pelc NJ,Zarins CK,Taylor CA

    更新日期:2004-08-01 00:00:00

  • Inferring multiple maxima in intravoxel white matter fiber distribution.

    abstract::A new methodology is introduced that characterizes the intravoxel orientation distribution function (ODF) based on a single-fiber model of the diffusion MRI signal. Using a Bayesian framework the probability of finding a fiber in a specific orientation is obtained. The proposed ODF estimation relies on a cigar-like di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21673

    authors: Canales-Rodríguez EJ,Melie-García L,Iturria-Medina Y,Martínez-Montes E,Alemán-Gómez Y,Lin CP

    更新日期:2008-09-01 00:00:00

  • Insights into tissue microstructure using a double diffusion encoding sequence on a clinical scanner: Validation and application to experimental tumor models.

    abstract:PURPOSE:To present a double diffusion encoding MRI sequence on a clinical scanner to analyze micro-structure and micro-vasculature of tumors. METHODS:The sequence was tested on phantoms, asparaguses, and 2 tumors allografts in a rodent. Results were analyzed using an adapted VERDICT model to estimate microstructural p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28012

    authors: Duchêne G,Abarca-Quinones J,Leclercq I,Duprez T,Peeters F

    更新日期:2020-04-01 00:00:00

  • Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

    abstract:PURPOSE:This study aims to (i) develop a new high-speed MRI approach by implementing correlation imaging in wavelet-space, and (ii) demonstrate the ability of wavelet-space correlation imaging to image human anatomy with involuntary or physiological motion. METHODS:Correlation imaging is a high-speed MRI framework in ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25546

    authors: Li Y,Wang H,Tkach J,Roach D,Woods J,Dumoulin C

    更新日期:2015-12-01 00:00:00

  • T2 relaxation reveals spatial collagen architecture in articular cartilage: a comparative quantitative MRI and polarized light microscopic study.

    abstract::It has been suggested that orientational changes in the collagen network of articular cartilage account for the depthwise T2 anisotropy of MRI through the magic angle effect. To investigate the relationship between laminar T2 appearance and collagen organization (anisotropy), bovine osteochondral plugs (N = 9) were T2...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1218

    authors: Nieminen MT,Rieppo J,Töyräs J,Hakumäki JM,Silvennoinen J,Hyttinen MM,Helminen HJ,Jurvelin JS

    更新日期:2001-09-01 00:00:00

  • Proton high-resolution magic angle spinning NMR analysis of fresh and previously frozen tissue of human prostate.

    abstract::The previously observed improvement in spectral resolution of tissue proton NMR with high-resolution magic angle spinning (HRMAS) was speculated to be due largely to freeze-thawing artifacts resulting from tissue storage. In this study, 12 human prostate samples were analyzed on a 14.1T spectrometer at 3 degrees C, wi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10645

    authors: Wu CL,Taylor JL,He W,Zepeda AG,Halpern EF,Bielecki A,Gonzalez RG,Cheng LL

    更新日期:2003-12-01 00:00:00

  • A semiautomatic method for rapid segmentation of velocity-encoded myocardial magnetic resonance imaging data.

    abstract:PURPOSE:To develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. METHODS:Manual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26486

    authors: Espe EKS,Skårdal K,Aronsen JM,Zhang L,Sjaastad I

    更新日期:2017-09-01 00:00:00

  • 3T MR of the prostate: reducing susceptibility gradients by inflating the endorectal coil with a barium sulfate suspension.

    abstract::Most prostate MRI/MRS examinations are performed with an endorectal coil inflated with air, leading to an air-tissue interface that induces magnetic susceptibility gradients within the gland. Inflation of the coil with a barium sulfate suspension is described and compared to inflation with air or liquid perfluorocarbo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21166

    authors: Rosen Y,Bloch BN,Lenkinski RE,Greenman RL,Marquis RP,Rofsky NM

    更新日期:2007-05-01 00:00:00

  • Analysis of the evolution of focal cerebral ischemia in the rat using the eigenimage filter.

    abstract::The eigenimage filter was used to evaluate the results of a MRI study of cerebral ischemia in a rat model. This linear filter segments a desired feature in an image sequence from other features which may interfere with its observation. The animals were imaged temporally, after occlusion of the middle cerebral artery, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910260207

    authors: Peck DJ,Spickler EM,Knight RA,Hearshen DO,Windham JP

    更新日期:1992-08-01 00:00:00