Abstract:
PURPOSE:To develop a semiautomatic method for rapid segmentation of myocardial tissue phase mapping (TPM) data. METHODS:Manual segmentation of the myocardium was performed at end-diastole and end-systole. The points in both user-defined masks were then automatically tracked over the entire cardiac cycle using temporal integration of the velocity field. Paths that failed to visit both masks at the expected times were excluded, after which masks for all time points were generated automatically from the accepted paths. Midventricular and basal phase contrast TPM slices from 12 rats were segmented using the proposed method and fully manual segmentation. The results were compared using Dice's metric and Bland-Altman analysis, and interobserver variability was assessed. RESULTS:The semiautomatic method reduced the average user input time from 21 min to 1 min per slice. The Dice metrics between the methods were 0.88 ± 0.03 (midventricular) and 0.83 ± 0.06 (basal), and Bland-Altman limits of agreement of peak systolic and diastolic regional velocities were: midventricular: 0.05 ± 0.65 cm/s, -0.02 ± 0.42 cm/s, and -0.03 ± 0.40 cm/s (radial, tangential, longitudinal); basal: -0.04 ± 0.73 cm/s, 0.03 ± 0.60 cm/s, and -0.04 ± 0.48 cm/s (radial, tangential, longitudinal). Interobserver variability following semiautomatic segmentation was lower than for manual segmentation. CONCLUSION:The proposed method reduced the segmentation time substantially and exhibited well-preserved data quality and excellent interobserver limits of agreement. Magn Reson Med 78:1199-1207, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Espe EKS,Skårdal K,Aronsen JM,Zhang L,Sjaastad Idoi
10.1002/mrm.26486subject
Has Abstractpub_date
2017-09-01 00:00:00pages
1199-1207issue
3eissn
0740-3194issn
1522-2594journal_volume
78pub_type
杂志文章abstract::For patients with impaired breath-hold capacity and/or arrhythmias, real-time cine MRI may be more clinically useful than breath-hold cine MRI. However, commercially available real-time cine MRI methods using parallel imaging typically yield relatively poor spatio-temporal resolution due to their low image acquisition...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24440
更新日期:2013-07-01 00:00:00
abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21648
更新日期:2008-07-01 00:00:00
abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22415
更新日期:2010-07-01 00:00:00
abstract::Diffusion tensor imaging has been used in a number of spinal cord studies, but severe distortions caused by susceptibility induced field inhomogeneities limit its applicability to investigate small volumes within acceptable acquisition times. A way to evaluate image distortions is to map the point spread function of t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24235
更新日期:2013-01-01 00:00:00
abstract::Two single-shot volume imaging techniques are described. The first, single-echo echo-volume imaging, is essentially the echo-volume imaging (EVI) sequence suggested by Mansfield (J. Phys. C. 10, L55 (1977)). The second is a multi-spin-echo approach in which one plane of k-space is collected during each spin echo. In b...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320518
更新日期:1994-11-01 00:00:00
abstract::High polarization of nuclear spins in liquid state through hyperpolarized technology utilizing dynamic nuclear polarization has enabled the direct monitoring of (13)C metabolites in vivo at a high signal-to-noise ratio. Acquisition time limitations due to T(1) decay of the hyperpolarized signal require accelerated ima...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22233
更新日期:2010-02-01 00:00:00
abstract::A non-invasive method for studying the modifications induced in lipid depots by hormonal stimulation could extend knowledge of adipose tissues. We studied the effect of adrenergic stimulation on interscapular brown adipose tissue (IBAT) of rats using contrast-enhanced MRI. Controls and rats pre-treated with adrenaline...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20851
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:An increasing number of studies show that magnetic susceptibility in white matter fibers is anisotropic and may be described by a tensor. However, the limited head rotation possible for in vivo human studies leads to an ill-conditioned inverse problem in susceptibility tensor imaging (STI). Here we suggest the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25322
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28430
更新日期:2021-01-01 00:00:00
abstract::Excitation by conventional B1 pulses in surface coil chemical-shift imaging experiments yields resonance intensities that vary greatly with position. B1-compensated semi-selective pulses overcome much of this problem. These pulses are employed for excitation and refocusing in 1H NMR spectroscopic localization in the i...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910250118
更新日期:1992-05-01 00:00:00
abstract:PURPOSE:The clinical potential of the diffusion imaging-based analysis of fine brain structures such as fornix or cingulum is high due to the central role of these structures in psychiatric diseases. However, the quantification of diffusion parameters in fine structures is especially prone to partial volume effects (PV...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24774
更新日期:2014-03-01 00:00:00
abstract::We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20683
更新日期:2005-11-01 00:00:00
abstract:PURPOSE:A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS:Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanne...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24612
更新日期:2013-04-01 00:00:00
abstract::We have obtained high-field (11.7 Tesla), high-resolution carbon-13 solid-state "magic-angle" sample-spinning nuclear magnetic resonance (NMR) spectra of a variety of phospholipids, sphingolipids, myelin and white matter samples, resolving and assigning over 40 resonances in the spectra of human and bovine myelin. The...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290204
更新日期:1993-02-01 00:00:00
abstract::This study aims to assess whether an alternative method, that is based on volumetric surface detection (VoSD) without tracing and is totally free of geometric assumptions, can improve the reproducibility of right ventricular (RV) volume quantification from cardiac magnetic resonance (CMR) images, in comparison with a ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21157
更新日期:2007-03-01 00:00:00
abstract::Spatially resolved spectroscopy (SPARS) is a method for obtaining high-resolution NMR spectra of well-defined volumes of human tissues in situ. This method was combined with the Carr-Purcell-Meiboom-Gill multiple-echo sequence for T2, and with inversion recovery for T1 relaxation measurements. Relaxation times obtaine...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910040504
更新日期:1987-05-01 00:00:00
abstract::High-field (>or=3 T) cardiac MRI is challenged by inhomogeneities of both the static magnetic field (B(0)) and the transmit radiofrequency field (B(1)+). The inhomogeneous B fields not only demand improved shimming methods but also impede the correct determination of the zero-order terms, i.e., the local resonance fre...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22234
更新日期:2010-02-01 00:00:00
abstract::The potential application of gas microbubbles as a unique intravascular susceptibility contrast agent for MRI has not been fully explored. In this study, the MR susceptibility effect of an ultrasound microbubble contrast agent, Optison, was studied with rat liver imaging at 7 T. Optison suspension in two different dos...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20181
更新日期:2004-09-01 00:00:00
abstract::A gradient coil design algorithm capable of controlling the position of the homogeneous region of interest (ROI) with respect to the current-carrying wires is required for many advanced imaging and spectroscopy applications. A modified minimum inductance target field method that allows the placement of a set of constr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390214
更新日期:1998-02-01 00:00:00
abstract:PURPOSE:A new method, called Transmit and Receive Patterns from Low-Tip-angle gradient-Echo Images (TRIPLET), is described which simultaneously maps the B1+ and B1- fields of a transmit/receive radiofrequency coil array. The input data are low-tip-angle gradient-echo images, which can be acquired in a relatively short ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24912
更新日期:2014-07-01 00:00:00
abstract::Spiral k-space magnetic resonance spectroscopic imaging (MRSI) requires high performance from gradient hardware systems. During the readout phase, oscillating gradients are continuously played out, which can cause undesired effects. These effects on the quality of SI data are non-intuitive because of their time-varyin...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20928
更新日期:2006-07-01 00:00:00
abstract::How stem cells promote myocardial repair in myocardial infarction (MI) is not well understood. The purpose of this study was to noninvasively monitor and quantify mesenchymal stem cells (MSC) from bone marrow to MI sites using magnetic resonance imaging (MRI). MSC were dual-labeled with an enhanced green fluorescent p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22735
更新日期:2011-05-01 00:00:00
abstract::Although promising for visualizing the structure of ordered tissues, MR diffusion tensor imaging (DTI) has been hampered by long acquisition time and low spatial resolution associated with its inherently low signal-to-noise ratio (SNR). Moreover, the uncertainty in the DTI measurements has a direct impact on the accur...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20582
更新日期:2005-08-01 00:00:00
abstract::Rapid flow imaging was achieved with a partial field of view (pFOV) spiral motion-encoded technique. The FOV and the acquisition time were reduced by a factor of 2 by undersampling k-space. The pFOV spiral k-space trajectory aliased signals from outside a circular ring whose radius was inversely proportional to the di...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/mrm.20975
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:To investigate Shift Undersampling improves Parametric mapping Efficiency and Resolution (SUPER), a novel blockwise curve-fitting method for accelerating parametric mapping with very fast reconstruction. METHODS:SUPER uses interleaved k-space undersampling, which enables a blockwise decomposition of the otherw...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27662
更新日期:2019-06-01 00:00:00
abstract::Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21013
更新日期:2006-10-01 00:00:00
abstract::The combination of an in-plane B(1) sensitivity encoding (SENSE) technique with a simultaneous multiple-slice B(0) field step technique (multiple-acquisition micro B(0) array (MAMBA)) has produced high scan time reduction factors (R < or = 8). In this study, two slices were acquired simultaneously in combination with ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10464
更新日期:2003-06-01 00:00:00
abstract::A method for evaluating the sensitivity of MRI protocols to changes in an arbitrary number of tissue parameters over a broad range of parameter values is presented. This analysis is useful for choosing an optimal basis set of images for either a "survey" protocol or tissue segmentation algorithms. A survey protocol is...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910130202
更新日期:1990-02-01 00:00:00
abstract:PURPOSE:This study aimed to evaluate the reproducibility and specificity of quantitative magnetization transfer (qMT) imaging for monitoring spinal cord injuries (SCIs). METHODS:MRI scans were performed in anesthetized monkeys at 9.4T, before and serially after a unilateral lesion of the cervical spinal cord. A two-po...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25725
更新日期:2016-04-01 00:00:00
abstract::The purpose of this study is (1) to determine the correlation between T(1rho) and T(2) and degenerative grade in intervertebral discs using in vivo 3.0-T MRI, and (2) to determine the association between T(1rho) and T(2) and clinical findings as quantified by the SF-36 Questionnaire and Oswestry Disability Index. Sixt...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22362
更新日期:2010-05-01 00:00:00