Contrast-enhanced MRI of brown adipose tissue after pharmacological stimulation.

Abstract:

:A non-invasive method for studying the modifications induced in lipid depots by hormonal stimulation could extend knowledge of adipose tissues. We studied the effect of adrenergic stimulation on interscapular brown adipose tissue (IBAT) of rats using contrast-enhanced MRI. Controls and rats pre-treated with adrenaline 40 s before the acquisition of pre-contrast images were used. In the control group, IBAT showed an enhancement of 56 +/- 29%, whereas adrenaline pre-treatment resulted in a significantly higher value (83 +/- 49%, P < 0.05). In the control group, the skeletal muscle of the anterior limb showed an enhancement of 24 +/- 12%, while adrenaline pre-treatment led to a higher value (26 +/- 10%), although the difference was not significant. In the control group, the skeletal muscle adjacent to the IBAT showed an enhancement of 30 +/- 13%, while adrenaline pre-treatment resulted in a non-significantly higher value (33 +/- 10%). In both groups, enhancement values in the muscle adjacent to the IBAT were significantly higher than the values in the muscle of the anterior limb (P < 0.05). This study demonstrates the feasibility of detecting the effect of hormonal stimulation on small fat depots. The demonstration of greater blood flow in the muscles surrounding the IBAT than in the muscles of the anterior limb suggests that the muscles of the back operate in synergy with the IBAT.

journal_name

Magn Reson Med

authors

Sbarbati A,Cavallini I,Marzola P,Nicolato E,Osculati F

doi

10.1002/mrm.20851

subject

Has Abstract

pub_date

2006-04-01 00:00:00

pages

715-8

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

55

pub_type

杂志文章
  • The effects of intravoxel contrast agent diffusion on the analysis of DCE-MRI data in realistic tissue domains.

    abstract:PURPOSE:Quantitative evaluation of dynamic contrast enhanced MRI (DCE-MRI) allows for estimating perfusion, vessel permeability, and tissue volume fractions by fitting signal intensity curves to pharmacokinetic models. These compart mental models assume rapid equilibration of contrast agent within each voxel. However, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26995

    authors: Woodall RT,Barnes SL,Hormuth DA 2nd,Sorace AG,Quarles CC,Yankeelov TE

    更新日期:2018-07-01 00:00:00

  • Fe(III) distribution varies substantially within and between atherosclerotic plaques.

    abstract:PURPOSE:Vulnerable atherosclerotic plaques are structurally weak and prone to rupture, presumably due to local oxidative stress. Redox active iron is linked to oxidative stress and the aim of this study was to investigate the distribution of Fe(III) in carotid plaques and its relation to vulnerability for rupture. MET...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24687

    authors: Gustafsson H,Hallbeck M,Norell M,Lindgren M,Engström M,Rosén A,Zachrisson H

    更新日期:2014-02-01 00:00:00

  • Imaging articular cartilage under compression--cartilage elastography.

    abstract::We constructed a device to compress small samples of articular cartilage while the samples were imaged in a 1.5 T imager. With the use of a piezoelectric piston, the device compressed 1-cm-diameter cylindrical samples of articular cartilage (200 microm) at a rate of 2 Hz. Simultaneously, we imaged the samples with a d...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20439

    authors: Hardy PA,Ridler AC,Chiarot CB,Plewes DB,Henkelman RM

    更新日期:2005-05-01 00:00:00

  • Theoretical analysis of the effect of imperfect slice profiles on tagging schemes for pulsed arterial spin labeling MRI.

    abstract::Pulsed arterial spin labeling (ASL) techniques provide a noninvasive method of obtaining qualitative and quantitative perfusion images with MRI. ASL techniques employ inversion recovery and/or saturation recovery to induce perfusion weighting, and thus the performance of these techniques is dependent on the slice prof...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1169

    authors: Keilholz-George SD,Knight-Scott J,Berr SS

    更新日期:2001-07-01 00:00:00

  • Fast diffusion imaging with high angular resolution.

    abstract:PURPOSE:High angular resolution diffusion imaging (HARDI) is a well-established method to help reveal the architecture of nerve bundles, but long scan times and geometric distortions inherent to echo planar imaging (EPI) have limited its integration into clinical protocols. METHODS:A fast imaging method is proposed he...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26163

    authors: Chao TC,Chiou JG,Maier SE,Madore B

    更新日期:2017-02-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Carotid-CNS MR flow imaging.

    abstract::The authors present their 1-year experience with the use of 3DFT, time-of-flight MR angiography for the evaluation of vascular diseases of the head and neck. Their experience with over 150 patients indicates that this examination may be performed in conjunction with standard spin-echo imaging with only a minimal incre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140215

    authors: Masaryk TJ,Laub GA,Modic MT,Ross JS,Haacke EM

    更新日期:1990-05-01 00:00:00

  • Clinical prostate T2 quantification using magnetization-prepared spiral imaging.

    abstract::T(2) quantification may augment diagnostic T(2)-weighted imaging; to improve cancer detection via auto-segmentation of multi-parametric acquisitions and to potentiate longitudinal studies of prostate cancer. However, robust quantitative techniques are not generally accessible or refined for clinical translation. This ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22492

    authors: Foltz WD,Chopra S,Chung P,Bayley A,Catton C,Jaffray D,Wright GA,Haider MA,Ménard C

    更新日期:2010-10-01 00:00:00

  • The field dependence of NMR imaging. II. Arguments concerning an optimal field strength.

    abstract::Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal-to-noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information avail...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030509

    authors: Hoult DI,Chen CN,Sank VJ

    更新日期:1986-10-01 00:00:00

  • A new approach to autocalibrated dynamic parallel imaging based on the Karhunen-Loeve transform: KL-TSENSE and KL-TGRAPPA.

    abstract::TSENSE and TGRAPPA are autocalibrated parallel imaging techniques that can improve the temporal resolution and/or spatial resolution in dynamic magnetic resonance imaging applications. In its original form, TSENSE uses temporal low-pass filtering of the undersampled frames to create the sensitivity map. TGRAPPA uses a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22766

    authors: Ding Y,Chung YC,Jekic M,Simonetti OP

    更新日期:2011-06-01 00:00:00

  • Ifosfamide pharmacokinetics and hepatobiliary uptake in vivo investigated using single- and double-resonance 31P MRS.

    abstract::MRS has considerable potential for the measurement of drug pharmacokinetics in vivo. In this study single- and double-resonance (31)P MRS was used to investigate the biodistribution, pharmacokinetics, and metabolism of ifosfamide following administration of 500 mg/kg ifosfamide in guinea pigs. (1)H-decoupling was foun...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10540

    authors: Mancini L,Payne GS,Dzik-Jurasz AS,Leach MO

    更新日期:2003-08-01 00:00:00

  • Shielded-coaxial-cable coils as receive and transceive array elements for 7T human MRI.

    abstract:PURPOSE:To investigate the use of shielded-coaxial-cable (SCC) coils as elements for multi-channel receive-only and transceive arrays for 7T human MRI and to compare their performance with equivalently sized conventional loop coils. METHODS:The SCC coil element consists of a coaxial loop with interrupted central condu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27964

    authors: Ruytenberg T,Webb A,Zivkovic I

    更新日期:2020-03-01 00:00:00

  • Evidence for a contribution of paramagnetic ions to water proton spin-lattice relaxation in normal and malignant mouse tissues.

    abstract::Paramagnetic ions complexed to proteins may lose, retain, or enhance solvent paramagnetic relaxation (SPR) relative to free solution. We measured T1 and T2 of three mouse cancers, their normal counterparts, and six additional tissues. Long T1 of cancers was not caused by necrosis or by different contents of water, fat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180204

    authors: Negendank W,Corbett T,Crowley M,Kellogg C

    更新日期:1991-04-01 00:00:00

  • Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: preliminary results in 12 patients.

    abstract::The purpose of this study was to determine the value of a blood-pool contrast media (NC100150, Nycomed Imaging (now Amersham Health) Oslo, Norway) for evaluation of venous thrombosis of the deep veins of the pelvis and lower extremities. Twelve patients were prospectively evaluated with conventional X-ray venography (...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1002/mrm.10607

    authors: Aschauer M,Deutschmann HA,Stollberger R,Hausegger KA,Obernosterer A,Schöllnast H,Ebner F

    更新日期:2003-11-01 00:00:00

  • Total removal of unwanted harmonic peaks (TruHARP) MRI for single breath-hold high-resolution myocardial motion and strain quantification.

    abstract::Current MRI methods for myocardial motion and strain quantification have limited resolution because of Fourier space spectral peak interference. Methods have been proposed to remove this interference in order to improve resolution; however, these methods are clinically impractical due to the prolonged imaging times. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22403

    authors: Agarwal HK,Prince JL,Abd-Elmoniem KZ

    更新日期:2010-08-01 00:00:00

  • Magnitude image CSPAMM reconstruction (MICSR).

    abstract::Image reconstruction of tagged cardiac MR images using complementary spatial modulation of magnetization (CSPAMM) requires the subtraction of two complex datasets to remove the untagged signal. Although the resultant images typically have sharper and more persistent tags than images formed without complementary taggin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10523

    authors: NessAiver M,Prince JL

    更新日期:2003-08-01 00:00:00

  • Gadodiamide T1 relaxivity in brain tissue in vivo is lower than in saline.

    abstract::In vivo measurements of gadodiamide (Gd-DTPA-BMA) T(1) relaxivity were performed at 4.7 T in injured and normal rat brains. Cerebral lesions were induced in nine rats by a localized freezing method. T(1) maps of the lesions were generated before and after injection of Gd-DTPA-BMA (0.1-0.6 mmol/kg). Samples of normal a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20336

    authors: Pickup S,Wood AK,Kundel HL

    更新日期:2005-01-01 00:00:00

  • On the use of Bayesian probability theory for analysis of exponential decay data: an example taken from intravoxel incoherent motion experiments.

    abstract::Traditionally, the method of nonlinear least squares (NLLS) analysis has been used to estimate the parameters obtained from exponential decay data. In this study, we evaluated the use of Bayesian probability theory to analyze such data; specifically, that resulting from intravoxel incoherent motion NMR experiments. An...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290510

    authors: Neil JJ,Bretthorst GL

    更新日期:1993-05-01 00:00:00

  • A 3 T sodium and proton composite array breast coil.

    abstract:PURPOSE:The objective of this study was to determine whether a sodium phased array would improve sodium breast MRI at 3 T. The secondary objective was to create acceptable proton images with the sodium phased array in place. METHODS:A novel composite array for combined proton/sodium 3 T breast MRI is compared with a c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24860

    authors: Kaggie JD,Hadley JR,Badal J,Campbell JR,Park DJ,Parker DL,Morrell G,Newbould RD,Wood AF,Bangerter NK

    更新日期:2014-06-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • Null space imaging: nonlinear magnetic encoding fields designed complementary to receiver coil sensitivities for improved acceleration in parallel imaging.

    abstract::To increase image acquisition efficiency, we develop alternative gradient encoding strategies designed to provide spatial encoding complementary to the spatial encoding provided by the multiple receiver coil elements in parallel image acquisitions. Intuitively, complementary encoding is achieved when the magnetic fiel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24114

    authors: Tam LK,Stockmann JP,Galiana G,Constable RT

    更新日期:2012-10-01 00:00:00

  • Gradient field switching as a source for artifacts in MR imaging of metallic stents.

    abstract::Metallic implants, such as stents, have long been a concern in magnetic resonance imaging (MRI). In addition to safety issues, they are commonly associated with image artifacts. The mechanisms of radiofrequency- (RF) and susceptibility-induced artifacts have been thoroughly investigated. However, gradient-switching-in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20294

    authors: Shenhav A,Azhari H

    更新日期:2004-12-01 00:00:00

  • Mechanisms of proton spin dephasing in a system of magnetic particles.

    abstract::For protons diffusing among a system of magnetic particles, the process by which initial phase coherence is lost depends substantially on particle size. In this article, evidence for three dephasing mechanisms is presented: an incremental process at small particle sizes (motional averaging regime), a discrete process ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22966

    authors: de Haan HW

    更新日期:2011-12-01 00:00:00

  • A fuse for magnetic resonance imaging probes.

    abstract::In a research environment, a magnetic resonance imaging system's manufacturer-supplied protection against excessive rf power deposition in the sample is often compromised. This paper presents a widely applicable scheme, based on a commonly available fuse, that simply and effectively limits the average rf power into a ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090213

    authors: Hedges LK

    更新日期:1989-02-01 00:00:00

  • SUPER: A blockwise curve-fitting method for accelerating MR parametric mapping with fast reconstruction.

    abstract:PURPOSE:To investigate Shift Undersampling improves Parametric mapping Efficiency and Resolution (SUPER), a novel blockwise curve-fitting method for accelerating parametric mapping with very fast reconstruction. METHODS:SUPER uses interleaved k-space undersampling, which enables a blockwise decomposition of the otherw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27662

    authors: Hu C,Peters DC

    更新日期:2019-06-01 00:00:00

  • Assessment and compensation of susceptibility artifacts in gradient echo MRI of hyperpolarized 3He gas.

    abstract::The effects of macroscopic background field gradients upon 2D gradient echo images of inhaled (3)He in the human lung were investigated at 1.5 T. Effective compensation of in-slice signal loss in (3)He gradient echo images was then demonstrated using a multiple acquisition interleaved single gradient echo sequence. Th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10549

    authors: Wild JM,Fichele S,Woodhouse N,Paley MN,Swift A,Kasuboski L,van Beek EJ

    更新日期:2003-08-01 00:00:00

  • Sweep MRI with algebraic reconstruction.

    abstract::In the recently proposed technique Sweep Imaging with Fourier Transform (SWIFT), frequency-modulated radiofrequency pulses are used in concert with simultaneous acquisition to facilitate MRI of samples with very short transverse relaxation time. In the present work, sweep MRI is reviewed from a reconstruction perspect...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22516

    authors: Weiger M,Hennel F,Pruessmann KP

    更新日期:2010-12-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

    abstract::Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<167::aid-mrm1023>3.0

    authors: Mathiak K,Posse S

    更新日期:2001-01-01 00:00:00

  • MRI-based transfer function determination through the transfer matrix by jointly fitting the incident and scattered B 1 + field.

    abstract:PURPOSE:A purely experimental method for MRI-based transfer function (TF) determination is presented. A TF characterizes the potential for radiofrequency heating of a linear implant by relating the incident tangential electric field to a scattered electric field at its tip. We utilize the previously introduced transfer...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27974

    authors: Tokaya JP,Raaijmakers AJE,Luijten PR,Sbrizzi A,van den Berg CAT

    更新日期:2020-03-01 00:00:00