Abstract:
:The combination of an in-plane B(1) sensitivity encoding (SENSE) technique with a simultaneous multiple-slice B(0) field step technique (multiple-acquisition micro B(0) array (MAMBA)) has produced high scan time reduction factors (R < or = 8). In this study, two slices were acquired simultaneously in combination with x2 and x4 SENSE in-plane encoding using a MAMBA stepped B(0) field coil inside a four-channel phased-array coil system. Experiments were performed on a 1.5 T Infinion system (Philips Medical Systems, Cleveland, OH). The signal-to-noise ratio (SNR) was reduced with higher R factors, as was expected from the reduced number of acquisitions used to create the unaliased images. The combination of SENSE and MAMBA offers great promise for reducing scan times through parallel acquisition while at the same time reducing the number of RF channels required by a factor equal to the number of field steps employed. The B(1) array combined with MAMBA (B(1)AC-MAMBA) technique is applicable when the length of an object is much greater than its diameter, as in scanning limbs or in whole-body screening for disease.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Paley MN,Lee KJ,Wild JM,Fichele S,Whitby EH,Wilkinson ID,Van Beek EJ,Griffiths PDdoi
10.1002/mrm.10464subject
Has Abstractpub_date
2003-06-01 00:00:00pages
1196-200issue
6eissn
0740-3194issn
1522-2594journal_volume
49pub_type
杂志文章abstract::Segmented interleaved echo planar imaging offers a fast and efficient approach to magnetic resonance angiography. Unfortunately, this technique is particularly sensitive to oblique flow in the imaging plane. In this work, a mathematical analysis of oblique flow effects for several types of k-space coverage is presente...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1084
更新日期:2001-04-01 00:00:00
abstract::Dynamic contrast-enhanced MRI data in vertebral bone marrow (vBM) are currently analyzed with descriptive indices. The purpose of this study was to develop and evaluate a quantitative approach, considering the tissue composition of vBM. Therefore, a measurement of the water fraction, f(wat), and the precontrast relaxa...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22415
更新日期:2010-07-01 00:00:00
abstract::The properties of the image noise for selective averaging of phase-encoding lines have been investigated. For a given acquisition time, selective averaging results in a signal-to-noise ratio penalty compared to averaging all lines equally. In addition, selective averaging yields a non uniform distribution of noise cha...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910190115
更新日期:1991-05-01 00:00:00
abstract:PURPOSE:To develop a 256-channel dense-array electroencephalography (dEEG) sensor net (the Ink-Net) using high-resistance polymer thick film (PTF) technology to improve safety and data quality during simultaneous dEEG/MRI. METHODS:Heating safety was assessed with temperature measurements in an anthropomorphic head pha...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26116
更新日期:2017-02-01 00:00:00
abstract::A novel and automated technique is described for removing fMRI image artifacts resulting from motion outside of the imaging field of view. The technique is based on the Stockwell transform (ST), a mathematical operation that provides the frequency content at each time point within a time-varying signal. Using this tec...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10681
更新日期:2004-01-01 00:00:00
abstract::There is increasing interest in quantitative T(1) mapping techniques for a variety of applications. Several methods for T(1) quantification have been described. The acquisition of two spoiled gradient-echo data sets with different flip angles allows for the calculation of T(1) maps with a high spatial resolution and a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21776
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:Magnetization transfer ratio (MTR) histograms are used widely for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast, but confounding factors should also be minimized for high reproducibility. To this end, a 1-minute whole-brain spiral ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28618
更新日期:2020-12-08 00:00:00
abstract::A novel method, called relaxo-oximetry, for rapid spatially resolved in vivo measurements of oxygen concentration using time-domain radiofrequency (RF) electron paramagnetic resonance (EPR) is described. Time-domain data from triaryl methyl (TAM)-based single-electron contrast agents were processed by systematic delet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10133
更新日期:2002-05-01 00:00:00
abstract::Keyhole acquisition techniques have been used to reduce image acquisition times primarily in contrast agent studies and via simulation in interventional MRI procedures. More recent simulations have suggested that improved definition of an interventional device [e.g., biopsy needles, radio frequency (RF) electrodes] co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199909)42:3<554::aid-mrm18
更新日期:1999-09-01 00:00:00
abstract::In an effort to develop MRI methods for the evaluation of tumor angiogenesis (new blood vessel formation), MRI-derived cerebral blood volume (CBV) information has been compared to histologic measures of microvessel density (MVD). Although MVD is a standard marker of angiogenesis, it is not a direct correlate of the vo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1252
更新日期:2001-10-01 00:00:00
abstract:PURPOSE:To introduce a multiplatform, Python language-based, development environment called graphical programming interface for prototyping MRI techniques. METHODS:The interface allows developers to interact with their scientific algorithm prototypes visually in an event-driven environment making tasks such as paramet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25528
更新日期:2015-11-01 00:00:00
abstract::A novel method based on selective detection of rapidly changing DeltaB(0) magnetic fields and suppression of slowly changing DeltaB(0) fields is presented. The ultimate goal of this work is to present a method that may allow detection of transient and subtle changes in B(0) in cortical tissue associated with electrica...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10159
更新日期:2002-06-01 00:00:00
abstract::The application of spectroscopy techniques to the study of normal and pathological tissue is currently limited by the difficulties of acquiring precisely localized spectra and analyzing the resulting, relatively low signal-to-noise data. Interpretation of multivoxel spectroscopy data is greatly facilitated by estimati...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910250109
更新日期:1992-05-01 00:00:00
abstract::Breathing motion is one of the main sources of artifacts in MRI acquisitions that can severely impair diagnosis. In MRI with continuously moving table, the application of common motion compensation approaches such as breath holding or the synchronization of the measurement with the breathing motion can be problematic....
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22162
更新日期:2010-03-01 00:00:00
abstract::Subject motion during scan is a major source of artifacts in MR examinations. Prospective motion correction is a promising technique that tracks subject motion and adjusts the imaging volume in real time; however, additional retrospective correction may be necessary to achieve robust image quality and compatibility wi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24269
更新日期:2013-02-01 00:00:00
abstract::A MultiEcho Segmented EPI with z-shimmed BAckground gradient Compensation (MESBAC) pulse sequence is proposed and validated for functional MRI (fMRI) study in regions suffering from severe susceptibility artifacts. This sequence provides an effective tradeoff between spatial and temporal resolution and reduces image d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10219
更新日期:2002-08-01 00:00:00
abstract:PURPOSE:To validate an automatic algorithm for offline T2* measurements, providing robust, vendor-independent T2*, and uncertainty estimates for iron load quantification in the heart and liver using clinically available imaging sequences. METHODS:A T2* region of interest (ROI)-based algorithm was developed for robustn...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25767
更新日期:2016-04-01 00:00:00
abstract::The purpose of the study was to test a newly developed, MR-compatible, liquid nitrogen-cooled cryoprobe. The probe has an outer diameter of 3.5 mm and was specifically developed for percutaneous, MR-guided, interstitial cryotherapy. The probe was inserted percutaneously into the livers of 10 rabbits. The cryotherapy p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390304
更新日期:1998-03-01 00:00:00
abstract::Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20848
更新日期:2006-05-01 00:00:00
abstract::A multifocal mouse liver tumor model chemically induced with 5,9-dimethyl-7H-dibenzo[c,g]carbazole was investigated by respiratory-triggered morphological and functional MRI (fMRI) at 4.7 Tesla. The model is characterized by the presence of two tumor types: hypovascular cholangioma and vascularized hepatocellular carc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10555
更新日期:2003-09-01 00:00:00
abstract:PURPOSE:To investigate previously unreported effects of signal drift as a result of temporal scanner instability on diffusion MRI data analysis and to propose a method to correct this signal drift. METHODS:We investigated the signal magnitude of non-diffusion-weighted EPI volumes in a series of diffusion-weighted imag...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26124
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:To investigate Shift Undersampling improves Parametric mapping Efficiency and Resolution (SUPER), a novel blockwise curve-fitting method for accelerating parametric mapping with very fast reconstruction. METHODS:SUPER uses interleaved k-space undersampling, which enables a blockwise decomposition of the otherw...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27662
更新日期:2019-06-01 00:00:00
abstract::Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was int...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910060212
更新日期:1988-02-01 00:00:00
abstract:PURPOSE:Quantitative myocardial perfusion mapping has advantages over qualitative assessment, including the ability to detect global flow reduction. However, it is not clinically available and remains a research tool. Building upon the previously described imaging sequence, this study presents algorithm and implementat...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27954
更新日期:2020-02-01 00:00:00
abstract::A method is demonstrated for detection of magnetization from a selected region within the sensitive volume of a surface coil in a single acquisition. Composite pulses are described which eliminate signals from regions where magnetization is rotated 270 and 450 degrees. There is a loss of 1.3% or less of signal from re...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030221
更新日期:1986-04-01 00:00:00
abstract::MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910380512
更新日期:1997-11-01 00:00:00
abstract:PURPOSE:To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. METHODS:The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calcula...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28139
更新日期:2020-08-01 00:00:00
abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10358
更新日期:2002-12-01 00:00:00
abstract::Algorithms to reliably detect motion in navigator echoes are crucial to many MRI motion suppression techniques. The accuracy of these algorithms is affected by noise and deformation of navigator echo profile caused by physiologic motion. This study compared the performance of algorithms based on correlation and least ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910360120
更新日期:1996-07-01 00:00:00
abstract:PURPOSE:Cardiac T1 mapping has become an increasingly important imaging technique, contributing novel diagnostic options. However, currently utilized methods are often associated with accuracy problems because of heart rate variations and cardiac arrhythmia, limiting their value in clinical routine. This study aimed to...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27526
更新日期:2019-03-01 00:00:00