Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

Abstract:

:For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phase images and mask images to generate an optimal summary arteriogram. A paired double-blinded comparison demonstrated that this automatic algorithm is as effective as the manual process.

journal_name

Magn Reson Med

authors

Kim J,Prince MR,Zabih R,Bezanson J,Watts R,Erel HE,Wang Y

doi

10.1002/mrm.10358

subject

Has Abstract

pub_date

2002-12-01 00:00:00

pages

1004-10

issue

6

eissn

0740-3194

issn

1522-2594

journal_volume

48

pub_type

杂志文章
  • Relayed nuclear Overhauser enhancement imaging with magnetization transfer contrast suppression at 3 T.

    abstract:PURPOSE:To develop a pulsed CEST magnetization-transfer method for rapidly acquiring relayed nuclear Overhauser enhancement (rNOE)-weighted images with magnetic transfer contrast (MTC) suppression at clinical field strength (3 T). METHODS:Using a pulsed CEST magnetization-transfer method with low saturation powers (B1...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28433

    authors: Huang J,Han X,Chen L,Xu X,Xu J,Chan KWY

    更新日期:2021-01-01 00:00:00

  • Correlation of spectroscopy and magnetization transfer imaging in the evaluation of demyelinating lesions and normal appearing white matter in multiple sclerosis.

    abstract::Magnetization transfer imaging (MT) and localized proton spectroscopy (1H-MRS) were utilized in the evaluation of lesions (high signal abnormalities on T2-weighted images) and normal-appearing white matter (NAWM) in multiple sclerosis (MS). Eleven patients with a clinical diagnosis of MS were independently evaluated w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320303

    authors: Hiehle JF Jr,Lenkinski RE,Grossman RI,Dousset V,Ramer KN,Schnall MD,Cohen JA,Gonzalez-Scarano F

    更新日期:1994-09-01 00:00:00

  • Simultaneous multi-site EPR spectroscopy in vivo.

    abstract::A gradient technique to measure electron paramagnetic resonance spectra simultaneously at several different locations is described. The technique is based on the use of point probes containing paramagnetic centers. The value of the magnetic field gradient is chosen to be sufficient to separate the EPR signals from the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300210

    authors: Smirnov AI,Norby SW,Clarkson RB,Walczak T,Swartz HM

    更新日期:1993-08-01 00:00:00

  • Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload.

    abstract:PURPOSE:MR-based quantification of liver magnetic susceptibility may enable field strength-independent measurement of liver iron concentration (LIC). However, susceptibility quantification is challenging, due to nonlocal effects of susceptibility on the B0 field. The purpose of this work is to demonstrate feasibility o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24848

    authors: Hernando D,Cook RJ,Diamond C,Reeder SB

    更新日期:2013-09-01 00:00:00

  • Removal of phase artifacts from fMRI data using a Stockwell transform filter improves brain activity detection.

    abstract::A novel and automated technique is described for removing fMRI image artifacts resulting from motion outside of the imaging field of view. The technique is based on the Stockwell transform (ST), a mathematical operation that provides the frequency content at each time point within a time-varying signal. Using this tec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10681

    authors: Goodyear BG,Zhu H,Brown RA,Mitchell JR

    更新日期:2004-01-01 00:00:00

  • Three-dimensional MRI with an undersampled spherical shells trajectory.

    abstract::The shells trajectory is a 3D data acquisition method with improved efficiency compared to Cartesian sampling. It is a true center-out trajectory that does not repeatedly resample the center of k-space, and also offers advantages for motion correction. This work demonstrates that k-space undersampling can be combined ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20977

    authors: Shu Y,Riederer SJ,Bernstein MA

    更新日期:2006-09-01 00:00:00

  • An analytical solution for the SSFP signal in MRI.

    abstract::Among previous analyses of the steady-state free-precession (SSFP) signal in rapid MRI, one treatment resulted in equations that require the evaluation of infinite binomial series. Here, an analytical solution is derived by a transformation into the power series expansion of the derivative of the inverse sine function...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10410

    authors: Hänicke W,Vogel HU

    更新日期:2003-04-01 00:00:00

  • Is the detection of fucose cancer markers by 2D 1H NMR unequivocal?

    abstract::Fucose is believed to be a marker for cancer that may be detectable by the 2D proton NMR (COSY) of human plasma. However, the COSY technique is time consuming and prone to error. These problems may be alleviated by using the SUPERCOSY pulse sequence; this technique shows that there are many other cross peaks in the re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150102

    authors: Phillips PS,Herring FG

    更新日期:1990-07-01 00:00:00

  • Correction of chemical-shift artifacts in 19F imaging of PFOB: a robust signed magnitude method.

    abstract::This paper describes a method for correcting the chemical-shift artifacts in 19F NMR imaging of perfluoroctylbromide emulsion (PFOB) by utilizing the two spectral peaks of PFOB which have a long T2 value in conjunction with the Dixon method. Corrected images are obtained from the magnitude of the measured images using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230206

    authors: Lee HK,Nalcioglu O,Buxton RB

    更新日期:1992-02-01 00:00:00

  • GlucoCEST imaging with on-resonance variable delay multiple pulse (onVDMP) MRI.

    abstract:PURPOSE:To examine the detection sensitivity for the rapidly exchanging hydroxyl protons of D-glucose using the recently developed on-resonance variable delay multi-pulse (onVDMP) chemical exchange saturation transfer (CEST) technique. METHODS:The onVDMP method was applied for the detection of water signal changes upo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27364

    authors: Xu X,Xu J,Chan KWY,Liu J,Liu H,Li Y,Chen L,Liu G,van Zijl PCM

    更新日期:2019-01-01 00:00:00

  • MR coil design for simultaneous tip tracking and curvature delineation of a catheter.

    abstract::In active catheter tracking, small RF coils are attached to the catheter for localization. For interactive catheter steering at vessel branchings, it is necessary to visualize not only a single point near the catheter tip but also the entire shape and orientation of the catheter's distal end. Therefore, a 35-mm-long t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20108

    authors: Zuehlsdorff S,Umathum R,Volz S,Hallscheidt P,Fink C,Semmler W,Bock M

    更新日期:2004-07-01 00:00:00

  • Whole-body continuously moving table fat-water MRI with dynamic B0 shimming at 3 Tesla.

    abstract:PURPOSE:The purpose of this work was to develop a rapid and robust whole-body fat-water MRI (FWMRI) method using a continuously moving table (CMT) with dynamic field corrections at 3 Tesla. METHODS:CMT FWMRI was developed at 3 Tesla with a multiecho golden angle (GA) radial trajectory and dynamic B0 field shimming. Wh...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25848

    authors: Sengupta S,Smith DS,Gifford A,Welch EB

    更新日期:2016-07-01 00:00:00

  • Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling.

    abstract::The regional cerebral blood flow (rCBF) values determined using continuous arterial spin labeling (CASL) are subject to several sources of variability, including natural physiologic variations, sensitivity to the input parameters, and the use of different quantification models. To date, a thorough analysis of the impa...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20440

    authors: Steger TR,White RA,Jackson EF

    更新日期:2005-04-01 00:00:00

  • Fast diffusion tensor imaging and tractography of the whole cervical spinal cord using point spread function corrected echo planar imaging.

    abstract::Diffusion tensor imaging has been used in a number of spinal cord studies, but severe distortions caused by susceptibility induced field inhomogeneities limit its applicability to investigate small volumes within acceptable acquisition times. A way to evaluate image distortions is to map the point spread function of t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24235

    authors: Lundell H,Barthelemy D,Biering-Sørensen F,Cohen-Adad J,Nielsen JB,Dyrby TB

    更新日期:2013-01-01 00:00:00

  • Perfusion-weighted imaging of interictal hypoperfusion in temporal lobe epilepsy using FAIR-HASTE: comparison with H(2)(15)O PET measurements.

    abstract::To detect perfusion abnormalities in areas of high magnetic susceptibility in the brain, an arterial spin-labeling MRI technique utilizing flow-sensitive alternating inversion recovery (FAIR) and half-Fourier single shot turbo spin-echo (HASTE) for spin preparation and image acquisition, respectively, was developed. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200103)45:3<431::aid-mrm1056>3.0

    authors: Liu HL,Kochunov P,Hou J,Pu Y,Mahankali S,Feng CM,Yee SH,Wan YL,Fox PT,Gao JH

    更新日期:2001-03-01 00:00:00

  • MR microimaging of articular cartilage and contrast enhancement by manganese ions.

    abstract::Saline solutions of manganese ions (Mn2+) were used as articular contrast agents in magnetic resonance microscopy (9.4 T) of cartilage of chicken femoral condyles and pig temporomandibular joints. The diffusion of Mn2+ from the articular surface into the cartilage matrix led to a strong contrast enhancement in the car...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910240114

    authors: Kusaka Y,Gründer W,Rumpel H,Dannhauer KH,Gersonde K

    更新日期:1992-03-01 00:00:00

  • Dynamic changes in water ADC, energy metabolism, extracellular space volume, and tortuosity in neonatal rat brain during global ischemia.

    abstract::To obtain a better understanding of the mechanisms underlying early changes in the brain water apparent diffusion coefficient (ADC) observed in cerebral ischemia, dynamic changes in the ADC of water and in the energy status were measured at postnatal day 8 or 9 in neonatal rat brains after cardiac arrest using 1H MRS/...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360110

    authors: van der Toorn A,Syková E,Dijkhuizen RM,Vorísek I,Vargová L,Skobisová E,van Lookeren Campagne M,Reese T,Nicolay K

    更新日期:1996-07-01 00:00:00

  • Linear combination of multiecho data: short T2 component selection.

    abstract::The myelin sheath, which is wrapped around the axons in the brain, can be affected by many diseases, resulting in cognitive and physical disability. Other work showed water in the myelin sheath has a T2 approximately 15 ms. The current standard technique to estimate the fraction of myelin water in vivo is to collect m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10713

    authors: Jones CK,Xiang QS,Whittall KP,MacKay AL

    更新日期:2004-03-01 00:00:00

  • Modulation of the pharmacokinetics of macromolecular contrast material by avidin chase: MRI, optical, and inductively coupled plasma mass spectrometry tracking of triply labeled albumin.

    abstract::The goal of this work was to develop an MRI method for mapping the clearance of interstitial macromolecular plasma proteins after their extravasation from permeable blood vessels. To that end, a well-defined window of exposure to elevated blood levels was generated by inducing rapid clearance of macromolecular contras...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10638

    authors: Dafni H,Gilead A,Nevo N,Eilam R,Harmelin A,Neeman M

    更新日期:2003-11-01 00:00:00

  • Fast model-based T2 mapping using SAR-reduced simultaneous multislice excitation.

    abstract:PURPOSE:To obtain whole-brain high-resolution T2 maps in 2 minutes by combining simultaneous multislice excitation and low-power PINS (power independent of number of slices) refocusing pulses with undersampling and a model-based reconstruction. METHODS:A multi-echo spin-echo sequence was modified to acquire multiple s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27890

    authors: Hilbert T,Schulz J,Marques JP,Thiran JP,Krueger G,Norris DG,Kober T

    更新日期:2019-12-01 00:00:00

  • Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

    abstract:PURPOSE:At high field, T2 -weighted (T2 w) imaging is limited by transmit field inhomogeneity and increased radiofrequency power deposition. In this work, we introduce SAMPA (Slice-selective Adiabatic Magnetization T2 PrepAration) and demonstrate its use for efficient brain T2 w imaging at 7 Tesla (T). METHODS:SAMPA w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26067

    authors: Dyvorne H,Balchandani P

    更新日期:2016-12-01 00:00:00

  • Transceive phase mapping using the PLANET method and its application for conductivity mapping in the brain.

    abstract:PURPOSE:To demonstrate feasibility of transceive phase mapping with the PLANET method and its application for conductivity reconstruction in the brain. METHODS:Accuracy and precision of transceive phase (ϕ± ) estimation with PLANET, an ellipse fitting approach to phase-cycled balanced steady state free precession (bSS...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27958

    authors: Gavazzi S,Shcherbakova Y,Bartels LW,Stalpers LJA,Lagendijk JJW,Crezee H,van den Berg CAT,van Lier ALHMW

    更新日期:2020-02-01 00:00:00

  • Resolution-recovery for EPR imaging of free radical molecules in mice.

    abstract::A method of post-processing to enhance the image resolution of the distribution of free radical molecules obtained with continuous-wave electron paramagnetic resonance (CW-EPR) imaging is reported. The low spatial resolution of EPR imaging, which has created difficulties in biomedical applications, was overcome by the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22029

    authors: Ikebata Y,Sato-Akaba H,Aoyama T,Fujii H,Itoh K,Hirata H

    更新日期:2009-09-01 00:00:00

  • Phase contrast MRI with flow compensation view sharing.

    abstract:PURPOSE:To develop and evaluate a technique for accelerating phase contrast MRI (PC-MRI) acquisitions without significant compromise in flow quantification accuracy. METHODS:PC-MRI is commonly acquired using interleaved flow-compensated (FC) and flow-encoded (FE) echoes. We hypothesized that FC data, which represent b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25133

    authors: Wang D,Shao J,Rapacchi S,Middione MJ,Ennis DB,Hu P

    更新日期:2015-02-01 00:00:00

  • On the calculation of magnetization slice profiles for NMR imaging and in vivo spectroscopy.

    abstract::When developing new techniques for NMR imaging and in vivo spectroscopy it is a major advantage to be able to calculate the magnetization slice profiles, at any point during a pulse sequence in the presence of a field gradient. While this has frequently been done by treating the problem as a number of discrete resonan...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050511

    authors: Bulsing JM,Galloway GJ,Brereton IM,Doddrell DM

    更新日期:1987-11-01 00:00:00

  • MR elastography for evaluating regeneration of tissue-engineered cartilage in an ectopic mouse model.

    abstract:PURPOSE:The purpose of the present study was to apply noninvasive methods for monitoring regeneration and mechanical properties of tissue-engineered cartilage in vivo at different growth stages using MR elastography (MRE). METHODS:Three types of scaffolds, including silk, collagen, and gelatin seeded by human mesenchy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25745

    authors: Khalilzad-Sharghi V,Han Z,Xu H,Othman SF

    更新日期:2016-03-01 00:00:00

  • Robust estimation of spatially variable noise fields.

    abstract::Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22013

    authors: Landman BA,Bazin PL,Smith SA,Prince JL

    更新日期:2009-08-01 00:00:00

  • On the origin of paramagnetic inhomogeneity effects in blood.

    abstract::Hydrogen, sodium, and fluorine (added F-) NMR spectra of venous and oxygenated blood were measured. The fluorine resonance was seen as a single peak in both samples, and all three resonances exhibited the same deoxy-oxy shift. Because F- exchanges slowly across the red cell membrane, and because sodium is 95% extracel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120210

    authors: Brooks RA,Brunetti A,Alger JR,Di Chiro G

    更新日期:1989-11-01 00:00:00

  • Proton NMR study of the state of water in fibrin gels, plasma, and blood clots.

    abstract::A proton NMR relaxation and pulsed field gradient self-diffusion study of water in fibrin gels, plasma, and blood clots has been performed with special emphasis on the effect of the sol-gel and shrinkage transitions. Deuteron NMR in fibrin gels was also studied to supplement the proton data. It is shown that a measure...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140111

    authors: Blinc A,Lahajnar G,Blinc R,Zidansek A,Sepe A

    更新日期:1990-04-01 00:00:00

  • Assessment and correction of macroscopic field variations in 2D spoiled gradient-echo sequences.

    abstract:PURPOSE:To model and correct the dephasing effects in the gradient-echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations. METHODS:The dephasing of the spoiled 2D gradient-echo signal was modeled using a numerical solution of the Bloch equations to calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28139

    authors: Soellradl M,Lesch A,Strasser J,Pirpamer L,Stollberger R,Ropele S,Langkammer C

    更新日期:2020-08-01 00:00:00