Reducing oblique flow effects in interleaved EPI with a centric reordering technique.

Abstract:

:Segmented interleaved echo planar imaging offers a fast and efficient approach to magnetic resonance angiography. Unfortunately, this technique is particularly sensitive to oblique flow in the imaging plane. In this work, a mathematical analysis of oblique flow effects for several types of k-space coverage is presented. The conventional linear acquisition scheme, an alternating centric and a nonalternating centric encoding scheme are compared with respect to their flow properties. It is shown both by simulations and imaging experiments that artifacts from oblique in-plane flow are effectively reduced by both centric reordered phase-encoding schemes. The nonalternating centric acquisition scheme is preferred to the alternating centric scheme due to the smoother phase error transition in k-space in the presence of obliquely-angled flow. Magn Reson Med 45:623-629, 2001.

journal_name

Magn Reson Med

authors

Beck G,Li D,Haacke EM,Noll TG,Schad LR

doi

10.1002/mrm.1084

subject

Has Abstract

pub_date

2001-04-01 00:00:00

pages

623-9

issue

4

eissn

0740-3194

issn

1522-2594

pii

10.1002/mrm.1084

journal_volume

45

pub_type

杂志文章
  • Simultaneous assessment of cardiac metabolism and perfusion using copolarized [1-13 C]pyruvate and 13 C-urea.

    abstract:PURPOSE:To demonstrate the feasibility of imaging a bolus of co-polarized [1-13 C]pyruvate and 13 C-urea to simultaneously assess both metabolism and perfusion in the rodent heart. METHODS:Copolarized [1-13 C]pyruvate and 13 C-urea was imaged using a multi-echo, flow-sensitized spiral pulse sequence. Healthy rats were...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26106

    authors: Lau AZ,Miller JJ,Robson MD,Tyler DJ

    更新日期:2017-01-01 00:00:00

  • Strategy for lipid suppression in lactate imaging using STIR-DQCT: a study of hypoxic-ischemic brain injury.

    abstract::In vivo lactate detection using gradient enhanced double quantum coherence transfer (DQCT) was significantly improved by addition of short-time-inversion-recovery (STIR). Phantom studies demonstrated lipid suppression down to the background noise level with 33% loss of lactate signal. In vivo studies using a rabbit mo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400416

    authors: Nakai T,Rhine WD,Okada T,Stevenson DK,Spielman DM

    更新日期:1998-10-01 00:00:00

  • Improved data reconstruction method for GRAPPA.

    abstract::This paper presents an improved data reconstruction method for generalized autocalibrating partially parallel acquisitions (GRAPPA) using multicolumn multiline interpolation (MCMLI). Both nearest acquired line (ky) neighboring points and column (kx) neighboring points from all components of an array coil were used to ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20601

    authors: Wang Z,Wang J,Detre JA

    更新日期:2005-09-01 00:00:00

  • Iterative k-t principal component analysis with nonrigid motion correction for dynamic three-dimensional cardiac perfusion imaging.

    abstract:PURPOSE:In this study, an iterative k-t principal component analysis (PCA) algorithm with nonrigid frame-to-frame motion correction is proposed for dynamic contrast-enhanced three-dimensional perfusion imaging. METHODS:An iterative k-t PCA algorithm was implemented with regularization using training data corrected for...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24894

    authors: Schmidt JF,Wissmann L,Manka R,Kozerke S

    更新日期:2014-07-01 00:00:00

  • Real-time dynamic frequency and shim correction for single-voxel magnetic resonance spectroscopy.

    abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24129

    authors: Keating B,Ernst T

    更新日期:2012-11-01 00:00:00

  • MRI monitoring of focused ultrasound sonications near metallic hardware.

    abstract:PURPOSE:To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. METHOD:2DMSI was optimized for temperature sensitivity and applied...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27034

    authors: Weber H,Ghanouni P,Pascal-Tenorio A,Pauly KB,Hargreaves BA

    更新日期:2018-07-01 00:00:00

  • Kinetics of avidin-induced clearance of biotinylated bimodal liposomes for improved MR molecular imaging.

    abstract::Dual labeled liposomes, carrying both paramagnetic and fluorescent lipids, were recently proposed as potent contrast agents for MR molecular imaging. These nanoparticles are coated with poly(ethylene glycol) (PEG) to increase their blood circulation half-life, which should allow extensive accumulation at the targeted ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21780

    authors: van Tilborg GA,Strijkers GJ,Pouget EM,Reutelingsperger CP,Sommerdijk NA,Nicolay K,Mulder WJ

    更新日期:2008-12-01 00:00:00

  • Separation and quantification of lactate and lipid at 1.3 ppm by diffusion-weighted magnetic resonance spectroscopy.

    abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26144

    authors: Wang AM,Leung GK,Kiang KM,Chan D,Cao P,Wu EX

    更新日期:2017-02-01 00:00:00

  • Implementation of vascular-space-occupancy MRI at 7T.

    abstract::Vascular-space-occupancy (VASO) MRI exploits the difference between blood and tissue T1 to null blood signal and measure cerebral blood volume changes using the residual tissue signal. VASO imaging is more difficult at higher field because of sensitivity loss due to the convergence of tissue and blood T1 values and in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24334

    authors: Hua J,Jones CK,Qin Q,van Zijl PC

    更新日期:2013-04-01 00:00:00

  • Theory of heterogeneous relaxation in compartmentalized tissues.

    abstract::A new model of compartmentalized relaxation--that which occurs for spins (protons) exchanging between compartments of different relaxation rates--is presented. This model generalizes previous ones by allowing spatially dependent relaxation within compartments. Solutions for the diffusion-Bloch equations are found via ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370507

    authors: Barsky D,Pütz B,Schulten K

    更新日期:1997-05-01 00:00:00

  • Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles.

    abstract::There is increasing interest in quantitative T(1) mapping techniques for a variety of applications. Several methods for T(1) quantification have been described. The acquisition of two spoiled gradient-echo data sets with different flip angles allows for the calculation of T(1) maps with a high spatial resolution and a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21776

    authors: Preibisch C,Deichmann R

    更新日期:2009-01-01 00:00:00

  • Characterization of estrogen-receptor-targeted contrast agents in solution, breast cancer cells, and tumors in vivo.

    abstract::The estrogen receptor (ER) is a major prognostic biomarker of breast cancer, currently determined in surgical specimens by immunohistochemistry. Two new ER-targeted probes, pyridine-tetra-acetate-Gd chelate (PTA-Gd) conjugated either to 17β-estradiol (EPTA-Gd) or to tamoxifen (TPTA-Gd), were explored as contrast agent...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24442

    authors: Pais A,Biton IE,Margalit R,Degani H

    更新日期:2013-07-01 00:00:00

  • Comparison of blood oxygenation and cerebral blood flow effects in fMRI: estimation of relative oxygen consumption change.

    abstract::The most widely-used functional magnetic resonance imaging (fMRI) technique is based on the blood oxygenation level dependent (BOLD) effect, which requires at least partial uncoupling between cerebral blood flow (CBF) and oxygen consumption changes during increased mental activity. To compare BOLD and CBF effects duri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380110

    authors: Kim SG,Uğurbil K

    更新日期:1997-07-01 00:00:00

  • Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

    abstract::Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20615

    authors: Markl M,Leupold J,Bieri O,Scheffler K,Hennig J

    更新日期:2005-10-01 00:00:00

  • In vivo field-cycling relaxometry using an insert coil for magnetic field offset.

    abstract:PURPOSE:The T(1) of tissue has a strong dependence on the measurement magnetic field strength. T(1) -dispersion could be a useful contrast parameter, but is unavailable to clinical MR systems which operate at fixed magnetic field strength. The purpose of this work was to implement a removable insert magnet coil for fie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25040

    authors: Pine KJ,Goldie F,Lurie DJ

    更新日期:2014-11-01 00:00:00

  • ΔR2 (*) gadolinium-diethylenetriaminepentacetic acid relaxivity in venous blood.

    abstract::The accuracy of perfusion measurements using dynamic, susceptibility-weighted, contrast-enhanced MRI depends on estimating contrast agent concentration in an artery, i.e., the arterial input function. One of the difficulties associated with obtaining an arterial input function are partial volume effects when both bloo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24331

    authors: Patil V,Johnson G

    更新日期:2013-04-01 00:00:00

  • Direct CSF injection of MnCl(2) for dynamic manganese-enhanced MRI.

    abstract::MnCl(2) was injected intrathecally through the cisterna magna in rats, allowing infusion of divalent manganese ions (Mn(++)) into the CSF space and thence into the brain, without breaking the blood-brain barrier (BBB). Mn(++) uptake and washout dynamics in the brain were measured by serial T(1)-weighted MRI and EPI T(...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20047

    authors: Liu CH,D'Arceuil HE,de Crespigny AJ

    更新日期:2004-05-01 00:00:00

  • Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

    abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10358

    authors: Kim J,Prince MR,Zabih R,Bezanson J,Watts R,Erel HE,Wang Y

    更新日期:2002-12-01 00:00:00

  • Fat-water separation based on Transition REgion Extraction (TREE).

    abstract:PURPOSE:To develop a method based on fat-water transition region extraction (TREE) for robust fat-water separation and quantification in challenging scenarios, including low signal-to-noise ratio (SNR), fast changing B0 field, and disjointed anatomies. THEORY AND METHODS:In TREE method, the phasor solutions of each pi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27710

    authors: Peng H,Zou C,Cheng C,Tie C,Qiao Y,Wan Q,Lv J,He Q,Liang D,Liu X,Liu W,Zheng H

    更新日期:2019-07-01 00:00:00

  • B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

    abstract:PURPOSE:Imaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time-varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26790

    authors: Weavers PT,Tao S,Trzasko JD,Frigo LM,Shu Y,Frick MA,Lee SK,Foo TK,Bernstein MA

    更新日期:2018-03-01 00:00:00

  • 3D-printed Shepp-Logan phantom as a real-world benchmark for MRI.

    abstract:PURPOSE:As prescribed and reliable geometrical entities, phantoms have served as indispensable validation tools in a variety of MR-related topics. Though a number of phantoms have been conceived, certain applications may warrant highly customized geometries. The purpose of this study was to demonstrate the expediency o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25593

    authors: Kasten JA,Vetterli T,Lazeyras F,Van De Ville D

    更新日期:2016-01-01 00:00:00

  • Phase constrained encoding (PACE): a technique for MRI in large static field inhomogeneities.

    abstract::In spin echo imaging, magnetization is assigned to a location defined by its frequency of rotation. In the presence of a static magnetic field inhomogeneity, however, this location does not correspond to the true location of the magnetization. This paper describes a magnetic resonance imaging technique called phase co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330407

    authors: Kim JK,Plewes DB,Henkelman RM

    更新日期:1995-04-01 00:00:00

  • Image reconstruction algorithm for motion insensitive MR Fingerprinting (MRF): MORF.

    abstract:PURPOSE:The purpose of this study is to increase the robustness of MR fingerprinting (MRF) toward subject motion. METHODS:A novel reconstruction algorithm, MOtion insensitive MRF (MORF), was developed, which uses an iterative reconstruction based retrospective motion correction approach. Each iteration loops through t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27227

    authors: Mehta BB,Ma D,Pierre EY,Jiang Y,Coppo S,Griswold MA

    更新日期:2018-12-01 00:00:00

  • Introduction of the snake antenna array: Geometry optimization of a sinusoidal dipole antenna for 10.5T body imaging with lower peak SAR.

    abstract:PURPOSE:To improve imaging performance for body MRI with a local transmit array at 10.5T, the geometry of a dipole antenna was optimized to achieve lower peak specific absorption rate (SAR) levels and a more uniform transmit profile. METHODS:Electromagnetic simulations on a phantom were used to evaluate the SAR and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28297

    authors: Steensma B,van de Moortele PF,Ertürk A,Grant A,Adriany G,Luijten P,Klomp D,van den Berg N,Metzger G,Raaijmakers A

    更新日期:2020-11-01 00:00:00

  • Automatic segmentation of the brain and intracranial cerebrospinal fluid in T1-weighted volume MRI scans of the head, and its application to serial cerebral and intracranial volumetry.

    abstract::A new fully automatic algorithm for the segmentation of the brain and total intracranial cerebrospinal fluid (CSF) from T(1)-weighted volume MRI scans of the head, called Exbrain v.2, is described. The algorithm was developed in the context of serial intracranial volumetry. A brain mask obtained using a previous versi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10436

    authors: Lemieux L,Hammers A,Mackinnon T,Liu RS

    更新日期:2003-05-01 00:00:00

  • A novel phase-unwrapping method based on pixel clustering and local surface fitting with application to Dixon water-fat MRI.

    abstract:PURPOSE:To develop and evaluate a novel 2D phase-unwrapping method that works robustly in the presence of severe noise, rapid phase changes, and disconnected regions. THEORY AND METHODS:The MR phase map usually varies rapidly in regions adjacent to wraps. In contrast, the phasors can vary slowly, especially in regions...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26647

    authors: Cheng J,Mei Y,Liu B,Guan J,Liu X,Wu EX,Feng Q,Chen W,Feng Y

    更新日期:2018-01-01 00:00:00

  • Echo time-dependent quantitative susceptibility mapping contains information on tissue properties.

    abstract:PURPOSE:Magnetic susceptibility is a physical property of matter that varies depending on chemical composition and abundance of different molecular species. Interest is growing in mapping of magnetic susceptibility in the human brain using magnetic resonance imaging techniques, but the influences affecting the mapped v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26281

    authors: Sood S,Urriola J,Reutens D,O'Brien K,Bollmann S,Barth M,Vegh V

    更新日期:2017-05-01 00:00:00

  • Fast, three-dimensional free-breathing MR imaging of myocardial infarction: a feasibility study.

    abstract::Imaging delayed hyperenhancement of myocardial infarction is most commonly performed using an inversion recovery (IR) prepared 2D breathhold segmented k-space gradient echo (FGRE) sequence. Since only one slice is acquired per breathhold in this technique, 12-16 successive breathholds are required for complete anatomi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20061

    authors: Saranathan M,Rochitte CE,Foo TK

    更新日期:2004-05-01 00:00:00

  • Comparison of measuring energy metabolism by different (31) P-magnetic resonance spectroscopy techniques in resting, ischemic, and exercising muscle.

    abstract::Alternate methods to quantify mitochondrial activity or function have been extensively used for studying insulin resistance and type 2 diabetes mellitus, namely saturation transfer and phosphocreatine (PCr) recovery. As these methods are in fact determining different parameters, this study aimed to compare saturation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23095

    authors: Schmid AI,Schrauwen-Hinderling VB,Andreas M,Wolzt M,Moser E,Roden M

    更新日期:2012-04-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00