Simultaneous image acquisition from the head (or body) coil and a surface coil.

Abstract:

:Any number of coils can in principle be used simultaneously and independently in magnetic resonance imaging if the mutual inductances are sufficiently small. Surface coils and head or body coils have equal sensitivity at some crossover depth of the order of 6 to 10 cm. Using a 7.5-cm-diameter surface coil that was intrinsically isolated from the head coil, images were acquired simultaneously from both coils and combined to improve the signal-to-noise ratio at 6 cm depth by 2 1/2. A similar experiment with the body coil showed 2 1/2 improvement at about 8 cm depth.

journal_name

Magn Reson Med

authors

Hyde JS,Froncisz W,Jesmanowicz A,Kneeland JB

doi

10.1002/mrm.1910060212

subject

Has Abstract

pub_date

1988-02-01 00:00:00

pages

235-9

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

6

pub_type

杂志文章
  • Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

    abstract:PURPOSE:The goal of this study is to characterize and improve the accuracy of 2D magnetic resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B1 imperfections, which are two main factors that affect quantitative results in MRF. METHODS:The SP and B1 imperfections are characterized and correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26580

    authors: Ma D,Coppo S,Chen Y,McGivney DF,Jiang Y,Pahwa S,Gulani V,Griswold MA

    更新日期:2017-11-01 00:00:00

  • Globally optimal, minimum stored energy, double-doughnut superconducting magnets.

    abstract::The use of the minimum stored energy current density map-based methodology of designing closed-bore symmetric superconducting magnets was described recently. The technique is further developed to cater for the design of interventional-type MRI systems, and in particular open symmetric magnets of the double-doughnut co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22189

    authors: Tieng QM,Vegh V,Brereton IM

    更新日期:2010-01-01 00:00:00

  • Multiclass imbalance learning: Improving classification of pediatric brain tumors from magnetic resonance spectroscopy.

    abstract:PURPOSE:Classification of pediatric brain tumors from 1 H-magnetic resonance spectroscopy (MRS) can aid diagnosis and management of brain tumors. However, varied incidence of the different tumor types leads to imbalanced class sizes and introduces difficulties in classifying rare tumor groups. This study assessed diffe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26318

    authors: Zarinabad N,Wilson M,Gill SK,Manias KA,Davies NP,Peet AC

    更新日期:2017-06-01 00:00:00

  • Simultaneous quantification of T2 and T'2 using a combined gradient echo-spin echo sequence at ultrahigh field.

    abstract::Measuring T(2) at 7.0 T is not trivial due to RF inhomogeneity effects, however, gradient echo sampling of a spin echo is insensitive to RF pulse errors, does not suffer from significant distortions, and allows T'(2) and T(2) to be estimated simultaneously. Gradient echo sampling of a spin echo results are relatively ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22522

    authors: Cox EF,Gowland PA

    更新日期:2010-11-01 00:00:00

  • MR angiography by selective inversion recovery.

    abstract::A modified inversion-recovery sequence is introduced which performs subtraction angiography by varying time-of-flight effects of blood flowing into an imaged slab. The selective 180 degrees excitation inverts different regions between measurements to isolate arterial and/or venous blood. On normal human subjects, high...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040214

    authors: Nishimura DG,Macovski A,Pauly JM,Conolly SM

    更新日期:1987-02-01 00:00:00

  • Relaxation effects of ferucarbotran-labeled mesenchymal stem cells at 1.5T and 3T: discrimination of viable from lysed cells.

    abstract::Human mesenchymal stem cells (hMSCs) were labeled with Ferucarbotran by simple incubation and cultured for up to 14 d. Iron content was determined by spectrometry and the intracellular localization of the contrast agent uptake was studied by electron and confocal microscopy. At various time points after labeling, rang...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22011

    authors: Henning TD,Wendland MF,Golovko D,Sutton EJ,Sennino B,Malek F,Bauer JS,McDonald DM,Daldrup-Link H

    更新日期:2009-08-01 00:00:00

  • Diffusion tensor imaging using single-shot SENSE-EPI.

    abstract::SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10184

    authors: Bammer R,Auer M,Keeling SL,Augustin M,Stables LA,Prokesch RW,Stollberger R,Moseley ME,Fazekas F

    更新日期:2002-07-01 00:00:00

  • Highly accelerated submillimeter resolution 3D GRASE with controlled T 2 blurring in T 2 -weighted functional MRI at 7 Tesla: A feasibility study.

    abstract:PURPOSE:To achieve highly accelerated submillimeter resolution T 2 -weighted functional MRI at 7T by developing a three-dimensional gradient and spin echo imaging (GRASE) with inner-volume sel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28589

    authors: Park S,Torrisi S,Townsend JD,Beckett A,Feinberg DA

    更新日期:2020-11-24 00:00:00

  • Evaluation of MRI resolution affecting trabecular bone parameters: determination of acceptable resolution.

    abstract::The objective of this study is to evaluate the effect of MR image resolution on trabecular bone parameters and to determine the acceptable resolution that can be accurately analyzed to assess structural parameters. Ten distal femoral condyle specimens of 1 × 1 × 1 cm(3) were scanned with a 4.7-T Bruker BioSpec MRI sca...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22984

    authors: Kim N,Lee JG,Song Y,Kim HJ,S Yeom J,Cho G

    更新日期:2012-01-01 00:00:00

  • Restricted field of view magnetic resonance imaging of a dynamic time series.

    abstract::A restricted field of view (rFOV) approach for imaging a dynamic time series of volumes of limited spatial extent within a larger subject is described. The shorter readout with rFOV-MRI can be exploited to either limit image artifacts or increase spatial resolution. To accomplish rFOV imaging of a multislice volume fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21115

    authors: Pisani L,Bammer R,Glover G

    更新日期:2007-02-01 00:00:00

  • The phenomenon of separate intra- and extracellular resonances of difluorophosphate in 31P and 19F NMR spectra of erythrocytes.

    abstract::Trifluoroacetate and trifluoroacetamide, when added to a suspension of human red blood cells, give rise to separate 19F NMR signals from the intra- and extracellular species. This phenomenon has recently been exploited for measuring the membrane potential of erythrocytes. However, the separation of the peaks was incor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910180119

    authors: Xu AS,Potts JR,Kuchel PW

    更新日期:1991-03-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Rapid T1 mapping of mouse myocardium with saturation recovery Look-Locker method.

    abstract::Dynamic contrast-enhanced MRI using gadolinium or manganese provides unique characterization of myocardium and its pathology. In this study, an electrocardiography (ECG) triggered saturation recovery Look-Locker method was developed and validated for fast cardiac T(1) mapping in small animal models. By sampling the in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22544

    authors: Li W,Griswold M,Yu X

    更新日期:2010-11-01 00:00:00

  • Efficient sample density estimation by combining gridding and an optimized kernel.

    abstract::The reconstruction of non-Cartesian k-space trajectories often requires the estimation of nonuniform sampling density. Particularly for 3D, this calculation can be computationally expensive. The method proposed in this work combines an iterative algorithm previously proposed by Pipe and Menon (Magn Reson Med 1999;41:1...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23041

    authors: Zwart NR,Johnson KO,Pipe JG

    更新日期:2012-03-01 00:00:00

  • T1 rho relaxation and its application to MR histology.

    abstract::The application of T1 rho an an alternative contrast parameter in high-field magnetic resonance histology (MRH) has been investigated. Spectroscopic measurements of T1 rho were performed on 5.75% agar and 1.0 mM MnCI2 phantoms at 9.4 T to validate the accuracy of the imaging measurements. Image studies were performed ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350520

    authors: Engelhardt RT,Johnson GA

    更新日期:1996-05-01 00:00:00

  • In vivo measurement of brain metabolites using two-dimensional double-quantum MR spectroscopy--exploration of GABA levels in a ketogenic diet.

    abstract::A localized proton 2D double-quantum (DQ) spin-echo spectroscopy technique was implemented on 1.5 T clinical MRI scanners for the detection of gamma-aminobutyrate (GABA) in the brain. The 2D approach facilitates separation of peaks overlapping with GABA in 1D DQ-filtered (DQF) spectra. This technique was applied to fo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10429

    authors: Wang ZJ,Bergqvist C,Hunter JV,Jin D,Wang DJ,Wehrli S,Zimmerman RA

    更新日期:2003-04-01 00:00:00

  • Ventricular shape biomarkers for Alzheimer's disease in clinical MR images.

    abstract::The aim of this work was to identify ventricular shape-based biomarkers in MR images to discriminate between patients with Alzheimer's disease (AD) and healthy elderly. Clinical MR images were collected for 58 patients and 28 age-matched healthy controls. After normalizing all the images the ventricular cerebrospinal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21471

    authors: Ferrarini L,Palm WM,Olofsen H,van der Landen R,van Buchem MA,Reiber JH,Admiraal-Behloul F

    更新日期:2008-02-01 00:00:00

  • Exploring the limits of RF shimming for high-field MRI of the human head.

    abstract::Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21013

    authors: Mao W,Smith MB,Collins CM

    更新日期:2006-10-01 00:00:00

  • Methodological consensus on clinical proton MRS of the brain: Review and recommendations.

    abstract::Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,评审

    doi:10.1002/mrm.27742

    authors: Wilson M,Andronesi O,Barker PB,Bartha R,Bizzi A,Bolan PJ,Brindle KM,Choi IY,Cudalbu C,Dydak U,Emir UE,Gonzalez RG,Gruber S,Gruetter R,Gupta RK,Heerschap A,Henning A,Hetherington HP,Huppi PS,Hurd RE,Kantarci K,Ka

    更新日期:2019-08-01 00:00:00

  • In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

    abstract:PURPOSE:To investigate the feasibility of estimating calibration constants (K and T2o ) in vivo for converting whole-blood T2 to blood hemoglobin oxygen saturation (HbO2 ) according to the Luz-Meiboom model, 1/T2=1/T2o+K(1-HbO2)2, where K and T2o are relaxivity and transverse relaxation time of fully saturated blood, r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26885

    authors: Langham MC,Rodríguez-Soto AE,Schwartz N,Wehrli FW

    更新日期:2018-04-01 00:00:00

  • Sensitivity of MR diffusion measurements to variations in intracellular structure: effects of nuclear size.

    abstract::Magnetic resonance imaging measurements of the apparent rate of water diffusion in tumors are sensitive to variations in tissue cellularity, which have been shown useful for characterizing tumors and their responses to treatments. However, because of technical limitations on most MRI systems, conventional pulse gradie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21793

    authors: Xu J,Does MD,Gore JC

    更新日期:2009-04-01 00:00:00

  • Estimates of systolic and diastolic myocardial blood flow by dynamic contrast-enhanced MRI.

    abstract::Myocardial blood flow varies during the cardiac cycle in response to pulsatile changes in epicardial circulation and cyclical variation in myocardial tension. First-pass assessment of myocardial perfusion by dynamic contrast-enhanced MRI is one of the most challenging applications of MRI because of the spatial and tem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22538

    authors: Radjenovic A,Biglands JD,Larghat A,Ridgway JP,Ball SG,Greenwood JP,Jerosch-Herold M,Plein S

    更新日期:2010-12-01 00:00:00

  • Ultrahigh field single-refocused diffusion weighted imaging using a matched-phase adiabatic spin echo (MASE).

    abstract:PURPOSE:To improve ultrahigh field diffusion-weighted imaging (DWI) in the presence of inhomogeneous transmit B1 field by designing a novel semi-adiabatic single-refocused DWI technique. METHODS:A 180° slice-selective, adiabatic radiofrequency (RF) pulse of 4 ms duration was designed using the adiabatic Shinnar-Le Rou...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25790

    authors: Dyvorne H,O'Halloran R,Balchandani P

    更新日期:2016-05-01 00:00:00

  • Model-based mapping of fat unsaturation and chain length by chemical shift imaging--phantom validation and in vivo feasibility.

    abstract::Knowledge about the triglyceride (fat) (1)H spectrum enables quantitative determination of several triglyceride characteristics. This work describes a model-based chemical shift imaging method that separates water and fat signal and provides maps of three triglyceride quantities: fatty acid carbon chain length, unsatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24196

    authors: Berglund J,Ahlström H,Kullberg J

    更新日期:2012-12-01 00:00:00

  • Local specific absorption rate in brain tumors at 7 tesla.

    abstract:PURPOSE:MR safety at 7 Tesla relies on accurate numerical simulations of transmit electromagnetic fields to fully assess local specific absorption rate (SAR) safety. Numerical simulations for SAR safety are currently performed using models of healthy patients. These simulations might not be useful for estimating SAR in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25653

    authors: Restivo MC,van den Berg CA,van Lier AL,Polders DL,Raaijmakers AJ,Luijten PR,Hoogduin H

    更新日期:2016-01-01 00:00:00

  • Multi-turn transmit coil to increase b1 efficiency in current source amplification.

    abstract:PURPOSE:A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS:Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24612

    authors: Gudino N,Griswold MA

    更新日期:2013-04-01 00:00:00

  • Reducing oblique flow effects in interleaved EPI with a centric reordering technique.

    abstract::Segmented interleaved echo planar imaging offers a fast and efficient approach to magnetic resonance angiography. Unfortunately, this technique is particularly sensitive to oblique flow in the imaging plane. In this work, a mathematical analysis of oblique flow effects for several types of k-space coverage is presente...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1084

    authors: Beck G,Li D,Haacke EM,Noll TG,Schad LR

    更新日期:2001-04-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • MR microscopy of lung airways with hyperpolarized 3He.

    abstract::A technique using hyperpolarized (HP) 3He to image the small airways of the lung by using moderate flip angles and a short scanning period during early inspiration is demonstrated. Flip angles (alpha) ranging from 10-90 degrees were used in guinea pig experiments with scanning during the entire inspiration period. A s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390113

    authors: Chen XJ,Chawla MS,Hedlund LW,Möller HE,MacFall JR,Johnson GA

    更新日期:1998-01-01 00:00:00

  • A framework for optimization-based design of motion encoding in magnetic resonance elastography.

    abstract:PURPOSE:In conventional three-dimensional magnetic resonance elastography, motion encoding gradients (MEGs) synchronized to a mechanical excitation are applied separately in each direction to encode tissue displacement generated by the corresponding waves. This requires long acquisition times that introduce errors due ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25280

    authors: Nir G,Sahebjavaher RS,Sinkus R,Salcudean SE

    更新日期:2015-04-01 00:00:00