Interactive continuously moving table (iCMT) large field-of-view real-time MRI.

Abstract:

:Continuously moving table (CMT) MRI is a new method that is capable of generating 3D, seamless, large field-of-view (FOV) images by acquiring readouts along the patient superior-inferior axis as the subject is translated through the scanner. For applications that require artifact-free images, such as arterial-phase contrast-enhanced (CE) angiography of the legs, a major challenge is to match the MR data acquisition and patient table motion with the dynamics of blood flow in the region of interest (ROI). Instead of restricting the CMT to predetermined constant table speeds, we adopted a more general approach in which the table motion is decoupled from the phase-encoding order. In our approach the table moves adaptively and in response to operator-provided feedback obtained from viewing real-time preview (or fluoroscopic) images. This interactivity is accomplished by integrating high temporal-spatial resolution encoding of the table position with real-time hybrid-space filling and image reconstruction. Experimental results obtained using our prototype interactive CMT (iCMT) system on a peripheral vascular phantom and five healthy volunteers demonstrate the feasibility of this robust and rapid imaging method for acquiring 3D large-FOV continuous images with patient-specific adaptive table motion profiles.

journal_name

Magn Reson Med

authors

Sabati M,Lauzon ML,Mahallati H,Frayne R

doi

10.1002/mrm.20848

subject

Has Abstract

pub_date

2006-05-01 00:00:00

pages

1202-9

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

55

pub_type

杂志文章
  • SAR comparison between CASL and pCASL at high magnetic field and evaluation of the benefit of a dedicated labeling coil.

    abstract:PURPOSE:To investigate the heating induced by (pseudo)-continuous arterial spin labeling ((p)CASL) sequences in vivo at 9.4T and to evaluate the benefit of a dedicated labeling coil. METHODS:Temperature was measured continuously in the brain, neck, and rectum of 9 rats with fiber-optic temperature probes while running...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27931

    authors: Hirschler L,Collomb N,Voiron J,Köhler S,Barbier EL,Warnking JM

    更新日期:2020-01-01 00:00:00

  • Validation of 13C NMR measurements of liver glycogen in vivo.

    abstract::The natural abundance 13C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310602

    authors: Gruetter R,Magnusson I,Rothman DL,Avison MJ,Shulman RG,Shulman GI

    更新日期:1994-06-01 00:00:00

  • A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla.

    abstract::Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imagin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22413

    authors: Adriany G,Auerbach EJ,Snyder CJ,Gözübüyük A,Moeller S,Ritter J,Van de Moortele PF,Vaughan T,Uğurbil K

    更新日期:2010-06-01 00:00:00

  • Online correction of respiratory-induced field disturbances for continuous MR-thermometry in the breast.

    abstract::MR-thermometry allows monitoring of the local temperature evolution during minimally invasive interventional therapies. However, for the particular case of MR-thermometry in the human breast, magnetic field variations induced by the respiratory cycle lead to phase fluctuations requiring a suitable correction strategy ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21954

    authors: Hey S,Maclair G,de Senneville BD,Lepetit-Coiffe M,Berber Y,Köhler MO,Quesson B,Moonen CT,Ries M

    更新日期:2009-06-01 00:00:00

  • Fast measurement of blood T1 in the human carotid artery at 3T: Accuracy, precision, and reproducibility.

    abstract:PURPOSE:To develop a fast protocol for measuring T1 values in the internal carotid artery (ICA), to validate this technique with in vitro measurements, and to evaluate its reproducibility. METHODS:A modified Look-Locker sequence was optimized to enable rapid determination of T1 in the ICA at 3T. T1 values from the ICA...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26325

    authors: Li W,Liu P,Lu H,Strouse JJ,van Zijl PCM,Qin Q

    更新日期:2017-06-01 00:00:00

  • Trace apparent diffusion coefficients of metabolites in human brain using diffusion weighted magnetic resonance spectroscopy.

    abstract::The rotationally invariant trace/3 apparent diffusion coefficients (ADC) of N-acetyl aspartate (NAA), creatine and phosphocreatine (tCr), and choline (Cho) were determined using a diffusion-weighted stimulated echo acquisition mode sequence at 3 T in three separate human brain regions, namely the subcortical white mat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20427

    authors: Ellegood J,Hanstock CC,Beaulieu C

    更新日期:2005-05-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • Stability constants and 1H relaxation effects of ternary complexes formed between Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, and Gd-EDTA and citrate, phosphate, and carbonate ions.

    abstract::Formation of ternary complexes between Gd-DTPA, Gd-DTPA-BMA, and Gd-DOTA, used as contrast enhancement agents in MRI and the endogenously available carbonate and phosphate ions, has been demonstrated. The extent of ternary complex formation and its effect on the proton relaxation, measured at 9 MHz, rates is negligibl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380120

    authors: Burai L,Hietapelto V,Király R,Tóth E,Brücher E

    更新日期:1997-07-01 00:00:00

  • Imaging of the active B1 field in vivo.

    abstract::The authors describe a method for accurate in vivo multislice imaging of the active component of the B1 field which is based on a previously proposed method, which uses the signal intensity ratio of two images measured with different excitation angles, and a repetition time TR 5 > or = 5 T1. The new method essentially...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350217

    authors: Stollberger R,Wach P

    更新日期:1996-02-01 00:00:00

  • Assessment of bias in experimentally measured diffusion tensor imaging parameters using SIMEX.

    abstract::Diffusion tensor imaging enables in vivo investigation of tissue cytoarchitecture through parameter contrasts sensitive to water diffusion barriers at the micrometer level. Parameters are derived through an estimation process that is susceptible to noise and artifacts. Estimated parameters (e.g., fractional anisotropy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24324

    authors: Lauzon CB,Crainiceanu C,Caffo BC,Landman BA

    更新日期:2013-03-01 00:00:00

  • Combined geometric and algebraic solutions for removal of bSSFP banding artifacts with performance comparisons.

    abstract:PURPOSE:Balanced steady state free precession (bSSFP) imaging suffers from off-resonance artifacts such as signal modulation and banding. Solutions for removal of bSSFP off-resonance dependence are described and compared, and an optimal solution is proposed. THEORY AND METHODS:An Algebraic Solution (AS) that complemen...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26150

    authors: Hoff MN,Andre JB,Xiang QS

    更新日期:2017-02-01 00:00:00

  • Fully automated patellofemoral MRI segmentation using holistically nested networks: Implications for evaluating patellofemoral osteoarthritis, pain, injury, pathology, and adolescent development.

    abstract:PURPOSE:Our clinical understanding of the relationship between 3D bone morphology and knee osteoarthritis, as well as our ability to investigate potential causative factors of osteoarthritis, has been hampered by the time-intensive nature of manually segmenting bone from MR images. Thus, we aim to develop and validate ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27920

    authors: Cheng R,Alexandridi NA,Smith RM,Shen A,Gandler W,McCreedy E,McAuliffe MJ,Sheehan FT

    更新日期:2020-01-01 00:00:00

  • Fast maximum intensity projection algorithm using shear warp factorization and reduced resampling.

    abstract::Maximal intensity projection (MIP) is routinely used to view MRA and other volumetric angiographic data. The straightforward implementation of MIP is ray casting that traces a volumetric data set in a computationally expensive manner. This article reports a fast MIP algorithm using shear warp factorization and reduced...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10114

    authors: Fang L,Wang Y,Qiu B,Qian Y

    更新日期:2002-04-01 00:00:00

  • Sensitivity and source of amine-proton exchange and amide-proton transfer magnetic resonance imaging in cerebral ischemia.

    abstract:PURPOSE:Amide-proton transfer (APT) and amine-water proton exchange (APEX) MRI can be viable to map pH-decreasing ischemic regions. However, their exact contributions are unclear. METHODS:We measured APEX- and APT-weighted magnetization transfer ratio asymmetry (denoted as APEXw and APTw), apparent diffusion coefficie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24639

    authors: Zong X,Wang P,Kim SG,Jin T

    更新日期:2014-01-01 00:00:00

  • Pulmonary perfusion: qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH.

    abstract::The accurate assessment of pulmonary perfusion is especially important in the evaluation of patients with suspected pulmonary embolism, a common and potentially lethal disorder that can be treated by aggressive anticoagulation. In this study, we demonstrate for the first time the use of MR to image pulmonary perfusion...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360402

    authors: Hatabu H,Gaa J,Kim D,Li W,Prasad PV,Edelman RR

    更新日期:1996-10-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Automated feature extraction for the classification of human in vivo 13C NMR spectra using statistical pattern recognition and wavelets.

    abstract::If magnetic resonance spectroscopy (MRS) is to become a useful tool in clinical medicine, it will be necessary to find reliable methods for analyzing and classifying MRS data. Automated methods are desirable because they can remove user bias and can deal with large amounts of data, allowing the use of all the availabl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910350608

    authors: Tate AR,Watson D,Eglen S,Arvanitis TN,Thomas EL,Bell JD

    更新日期:1996-06-01 00:00:00

  • Multiple inversion recovery MR subtraction imaging of human ventilation from inhalation of room air and pure oxygen.

    abstract::The feasibility of MR subtraction imaging of lung ventilation using air against oxygen using a multiple inversion recovery half-Fourier single-shot turbo spin echo (MIR-HASTE) sequence was investigated. Eight healthy, nonsmoking volunteers (3 males, 5 females; from 27 to 48 years of age) were studied on a 1.5 T MR uni...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/1522-2594(200006)43:6<913::aid-mrm21>3.0.c

    authors: Mai VM,Chen Q,Bankier AA,Edelman RR

    更新日期:2000-06-01 00:00:00

  • Motion correction in fMRI via registration of individual slices into an anatomical volume.

    abstract::An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired in the same fMRI ses...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<964::aid-mrm16

    authors: Kim B,Boes JL,Bland PH,Chenevert TL,Meyer CR

    更新日期:1999-05-01 00:00:00

  • Transcatheter intra-arterial perfusion (TRIP)-MRI biomarkers help detect immediate response to irreversible electroporation of rabbit VX2 liver tumor.

    abstract:PURPOSE:Irreversible electroporation (IRE) is a nonthermal tissue ablation technique that represents a promising treatment option for unresectable liver tumors, but the effectively treated zone cannot be reliably predicted. We investigate the potential benefit of transcatheter intra-arterial perfusion (TRIP) -MRI for t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28104

    authors: Figini M,Zhou K,Pan L,Sun C,Wang B,Hu S,Yang J,Shangguan J,Eresen A,Velichko Y,Yaghmai V,Zhang Z

    更新日期:2020-07-01 00:00:00

  • Brain water diffusion in normal and creatine-supplemented rats during transient global ischemia.

    abstract::Brain water diffusion in response to transient global ischemia (12 min), reperfusion (60 min), and cardiac arrest was monitored by localized proton magnetic resonance spectroscopy. The trace of the apparent diffusion coefficient tensor (ADC(Av)) was determined at high temporal resolution (10 sec) to assess the putativ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<798::aid-mrm23

    authors: Wick M,Fujimori H,Michaelis T,Frahm J

    更新日期:1999-10-01 00:00:00

  • Magnetization-prepared shells trajectory with automated gradient waveform design.

    abstract:PURPOSE:To develop a fully automated trajectory and gradient waveform design for the non-Cartesian shells acquisition, and to develop a magnetization-prepared (MP) shells acquisition to achieve an efficient three-dimensional acquisition with improved gray-to-white brain matter contrast. METHODS:After reviewing the she...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26863

    authors: Shu Y,Tao S,Trzasko JD,Huston J 3rd,Weavers PT,Bernstein MA

    更新日期:2018-04-01 00:00:00

  • Parallel transmit capability of various RF transmit elements and arrays at 7T MRI.

    abstract:PURPOSE:In this work, 22 configurations for remote radiofrequency (RF) coil arrays consisting of different transmit element designs for 7 Tesla (T) ultrahigh-field MRI are compared by numerical simulations. METHODS:Investigated transmit RF element types are rectangular loops, micro striplines, micro striplines with me...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26704

    authors: Rietsch SHG,Orzada S,Bitz AK,Gratz M,Ladd ME,Quick HH

    更新日期:2018-02-01 00:00:00

  • Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners.

    abstract:PURPOSE:This study aims to identify work-related and personal factors associated with workers' exposure to static magnetic fields (SMF) and motion-induced time-varying magnetic fields (TVMF) from MRI scanners. METHODS:Measurements of personal exposure to SMF and TVMF were performed among MRI staff during 439 work shif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25720

    authors: Schaap K,Christopher-De Vries Y,Cambron-Goulet É,Kromhout H

    更新日期:2016-05-01 00:00:00

  • SENSE reconstruction for multiband EPI including slice-dependent N/2 ghost correction.

    abstract:PURPOSE:Sensitivity encoding (SENSE) reconstruction of multiband echo planar imaging (EPI) may cause artifacts when simultaneously excited slices require different phase correction to remove the EPI-specific ghost shifted by half of the matrix size (N). We propose a simplified solution of this problem that combines SEN...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25915

    authors: Hennel F,Buehrer M,von Deuster C,Seuven A,Pruessmann KP

    更新日期:2016-09-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • Three-dimensional MRI with independent slab excitation and encoding.

    abstract::Three-dimensional MRI is typically performed with the same orientation for radiofrequency slab excitation and slab select phase encoding. We introduce independent slab excitation and encoding to create a new degree of freedom in three-dimensional MRI, which is the angular relationship between the prescribed excitation...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23043

    authors: Eissa A,Wilman AH

    更新日期:2012-02-01 00:00:00

  • Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

    abstract::Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<167::aid-mrm1023>3.0

    authors: Mathiak K,Posse S

    更新日期:2001-01-01 00:00:00

  • Quantitative magnetization transfer imaging in human brain at 3 T via selective inversion recovery.

    abstract::Quantitative magnetization transfer imaging yields indices describing the interactions between free water protons and immobile, macromolecular protons-including the macromolecular to free pool size ratio (PSR) and the rate of magnetization transfer between pools k(mf) . This study describes the first implementation of...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22928

    authors: Dortch RD,Li K,Gochberg DF,Welch EB,Dula AN,Tamhane AA,Gore JC,Smith SA

    更新日期:2011-11-01 00:00:00

  • Diffusion-weighted imaging of the human optic nerve: a new approach to evaluate optic neuritis in multiple sclerosis.

    abstract::The apparent diffusion coefficient (ADC) in the optic nerve was measured from diffusion-weighted magnetic resonance imaging using an intravoxel incoherent motion (IVIM) sequence. The subjects were seven normal volunteers and eight patients with multiple sclerosis (MS) with a total of four optic nerves with acute neuri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380317

    authors: Iwasawa T,Matoba H,Ogi A,Kurihara H,Saito K,Yoshida T,Matsubara S,Nozaki A

    更新日期:1997-09-01 00:00:00