Combined geometric and algebraic solutions for removal of bSSFP banding artifacts with performance comparisons.

Abstract:

PURPOSE:Balanced steady state free precession (bSSFP) imaging suffers from off-resonance artifacts such as signal modulation and banding. Solutions for removal of bSSFP off-resonance dependence are described and compared, and an optimal solution is proposed. THEORY AND METHODS:An Algebraic Solution (AS) that complements a previously described Geometric Solution (GS) is derived from four phase-cycled bSSFP datasets. A composite Geometric-Algebraic Solution (GAS) is formed from a noise-variance-weighted average of the AS and GS images. Two simulations test the solutions over a range of parameters, and phantom and in vivo experiments are implemented. Image quality and performance of the GS, AS, and GAS are compared with the complex sum and a numerical parameter estimation algorithm. RESULTS:The parameter estimation algorithm, GS, AS, and GAS remove most banding and signal modulation in bSSFP imaging. The variable performance of the GS and AS on noisy data justifies generation of the GAS, which consistently provides the highest performance. CONCLUSION:The GAS is a robust technique for bSSFP signal demodulation that balances the regional efficacy of the GS and AS to remove banding, a feat not possible with prevalent techniques. Magn Reson Med 77:644-654, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

journal_name

Magn Reson Med

authors

Hoff MN,Andre JB,Xiang QS

doi

10.1002/mrm.26150

subject

Has Abstract

pub_date

2017-02-01 00:00:00

pages

644-654

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

77

pub_type

杂志文章
  • Dynamic field map estimation using a spiral-in/spiral-out acquisition.

    abstract::The long readout times of single-shot acquisitions and the high field strengths desired for functional MRI (fMRI) using blood oxygenation level-dependent (BOLD) contrast make functional scans sensitive to magnetic field inhomogeneity. If it is not corrected during image reconstruction, field inhomogeneity can cause ge...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20079

    authors: Sutton BP,Noll DC,Fessler JA

    更新日期:2004-06-01 00:00:00

  • In vivo evaluation of intracellular pH and high-energy phosphate metabolites during regional myocardial ischemia in cats using 31P nuclear magnetic resonance.

    abstract::Phosphorus-31 nuclear magnetic resonance spectroscopy (31P NMR) was used to assess the temporal changes of high-energy phosphate metabolites in the region of acute myocardial ischemia of open-chest cats. Eight anesthetized cats were studied following ligation of the left anterior descending coronary artery. Creatine p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030209

    authors: Stein PD,Goldstein S,Sabbah HN,Liu ZQ,Helpern JA,Ewing JR,Lakier JB,Chopp M,LaPenna WF,Welch KM

    更新日期:1986-04-01 00:00:00

  • Deconvolution-based distortion correction of EPI using analytic single-voxel point-spread functions.

    abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28591

    authors: Patzig F,Mildner T,Schlumm T,Müller R,Möller HE

    更新日期:2020-11-21 00:00:00

  • The use of band-selectable digital filtering in magnetic resonance image enhancement.

    abstract::Manipulation of the data describing two-dimensional magnetic resonance (MR) images can be used to zoom an image, decrease image noise and artifacts by modeling, or emphasize object edges in the field of view. In this paper, a two-dimensional band-selectable digital filtering (2D-BSDF) technique is detailed. This can b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090307

    authors: Mitchell DK,Nichols ST,Smith MR,Scott K

    更新日期:1989-03-01 00:00:00

  • MRI assessment of coronary microvascular endothelial nitric oxide synthase function using myocardial T1 mapping.

    abstract:PURPOSE:Endothelial nitric oxide synthase (eNOS) plays a central role in regulating vascular tone, blood flow, and microvascular permeability. Endothelial dysfunction, including eNOS dysfunction, is an early biomarker of vascular disease. This study aimed to show that myocardial T1 mapping during nitric oxide synthase ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26870

    authors: Cui SX,Epstein FH

    更新日期:2018-04-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • Towards elimination of the dark-rim artifact in first-pass myocardial perfusion MRI: removing Gibbs ringing effects using optimized radial imaging.

    abstract:PURPOSE:Subendocardial dark-rim artifacts (DRAs) remain a major concern in first-pass perfusion (FPP) myocardial MRI and may lower the diagnostic accuracy for detection of ischemia. A major source of DRAs is the "Gibbs ringing" effect. We propose an optimized radial acquisition strategy aimed at eliminating ringing-ind...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24913

    authors: Sharif B,Dharmakumar R,LaBounty T,Arsanjani R,Shufelt C,Thomson L,Merz CN,Berman DS,Li D

    更新日期:2014-07-01 00:00:00

  • Magnetic resonance imaging of myocardial kinematics. Technique to detect, localize, and quantify the strain rates of the active human myocardium.

    abstract::A magnetic resonance imaging (MRI) method is presented to detect, localize, and quantify myocardial kinematics by measuring the material rate-of-strain tensor at each pixel in gated NMR images of the heart. The immediate, local effect of muscular activity is self-deformation, and the strain tensor is the basic mathema...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910270107

    authors: Wedeen VJ

    更新日期:1992-09-01 00:00:00

  • Solvate structures in water-methanol solutions of MRI contrast agents: electron spin echo envelope modulation in gadolinium chelates.

    abstract::Electron Spin Echo Envelope Modulation (ESEEM) data are reported for three gadolinium (III) chelates, Gd-EDTA, Gd-DTPA, and Gd-TTHA, in frozen D2O/CH3OD glasses. This series includes Gd-DTPA, an MRI contrast agent that is in clinical use. Three-pulse electron spin echo modulation patterns can be modeled to yield geome...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290414

    authors: Clarkson RB,Hwang JH,Belford RL

    更新日期:1993-04-01 00:00:00

  • Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

    abstract::We have developed a method for measuring the electrocardiogram (ECG) continuously during MR examinations. In contrast to ECG acquisition by wires, our new method is to amplify and convert the ECG into an optical signal directly above the patient's heart. The optical signal is transmitted out of the magnet bore by opti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320416

    authors: Felblinger J,Lehmann C,Boesch C

    更新日期:1994-10-01 00:00:00

  • Single-Voxel 1 H MR spectroscopy of cerebral nicotinamide adenine dinucleotide (NAD+ ) in humans at 7T using a 32-channel volume coil.

    abstract:PURPOSE:Reliable monitoring of tissue nicotinamide adenine dinucleotide (NAD+ ) concentration may provide insights on its roles in normal and pathological aging. In the present study, we report a 1 H MRS pulse sequence for the in vivo, localized 1 H MRS detection of NAD+ from the human brain. METHODS:Studies were carr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27971

    authors: Bagga P,Hariharan H,Wilson NE,Beer JC,Shinohara RT,Elliott MA,Baur JA,Marincola FM,Witschey WR,Haris M,Detre JA,Reddy R

    更新日期:2020-03-01 00:00:00

  • More accurate estimation of diffusion tensor parameters using diffusion Kurtosis imaging.

    abstract::With diffusion tensor imaging, the diffusion of water molecules through brain structures is quantified by parameters, which are estimated assuming monoexponential diffusion-weighted signal attenuation. The estimated diffusion parameters, however, depend on the diffusion weighting strength, the b-value, which hampers t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22603

    authors: Veraart J,Poot DH,Van Hecke W,Blockx I,Van der Linden A,Verhoye M,Sijbers J

    更新日期:2011-01-01 00:00:00

  • Proteoglycan-induced changes in T1rho-relaxation of articular cartilage at 4T.

    abstract::Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1208

    authors: Akella SV,Regatte RR,Gougoutas AJ,Borthakur A,Shapiro EM,Kneeland JB,Leigh JS,Reddy R

    更新日期:2001-09-01 00:00:00

  • High-resolution Fourier-encoded sub-millisecond echo time musculoskeletal imaging at 3 Tesla and 7 Tesla.

    abstract:PURPOSE:The feasibility of imaging musculoskeletal fibrous tissue components, such as menisci, ligaments, and tendons, with a conventional spoiled gradient echo technique is explored in vivo at 3 T and 7 T. METHODS:To this end, the echo time (TE1 ) of a conventional Fourier-encoded multicontrast three-dimensional SGPR...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24578

    authors: Deligianni X,Bär P,Scheffler K,Trattnig S,Bieri O

    更新日期:2013-11-01 00:00:00

  • Robust diffusion tensor imaging by spatiotemporal encoding: Principles and in vivo demonstrations.

    abstract:PURPOSE:Evaluate the usefulness of single-shot and of interleaved spatiotemporally encoded (SPEN) methods to perform diffusion tensor imaging (DTI) under various preclinical and clinical settings. METHODS:A formalism for analyzing SPEN DTI data is presented, tailored to account for the spatially dependent b-matrix wei...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26197

    authors: Solomon E,Liberman G,Nissan N,Frydman L

    更新日期:2017-03-01 00:00:00

  • Motion robust respiratory-resolved 3D radial flow MRI and its application in neonatal congenital heart disease.

    abstract:PURPOSE:To test and implement a motion-robust and respiratory-resolved 3D Radial Flow framework that addresses the need for rapid, high resolution imaging in neonatal patients with congenital heart disease. METHODS:A 4-point velocity encoding and 3D radial trajectory with double-golden angle ordering was combined with...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27945

    authors: Schrauben EM,Lim JM,Goolaub DS,Marini D,Seed M,Macgowan CK

    更新日期:2020-02-01 00:00:00

  • Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

    abstract::For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phas...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10358

    authors: Kim J,Prince MR,Zabih R,Bezanson J,Watts R,Erel HE,Wang Y

    更新日期:2002-12-01 00:00:00

  • Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26824

    authors: Zhang Z,Frydman L

    更新日期:2018-03-01 00:00:00

  • Rapid whole-brain gray matter imaging using single-slab three-dimensional dual-echo fast spin echo: A feasibility study.

    abstract:PURPOSE:To achieve rapid, high resolution whole-brain gray matter (GM) imaging by developing a novel, single-slab three-dimensional dual-echo fast-spin-echo pulse sequence and GM-selective reconstruction. METHODS:Unlike conventional GM imaging that uses time-consuming double-inversion-recovery preparation, the propose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26910

    authors: Lee H,Kim EY,Sohn CH,Park J

    更新日期:2017-11-01 00:00:00

  • Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla.

    abstract::Cervical spinal cord spectroscopy has the potential to add metabolic information to spinal cord MRI and improve the clinical evaluation and research investigation of spinal cord diseases, such as multiple sclerosis (MS) and intraspinal tumors. However, in vivo proton MR spectroscopy ((1)H-MRS) of the spinal cord is di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21113

    authors: Marliani AF,Clementi V,Albini-Riccioli L,Agati R,Leonardi M

    更新日期:2007-01-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • Interleaved diffusion-weighted improved by adaptive partial-Fourier and multiband multiplexed sensitivity-encoding reconstruction.

    abstract:PURPOSE:We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion-weighted imaging (DWI). METHODS:First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction alg...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25318

    authors: Chang HC,Guhaniyogi S,Chen NK

    更新日期:2015-05-01 00:00:00

  • Piezoelectric-controlled tuning capacitor for surface coils.

    abstract::The design of a piezoelectric-controlled trimmer capacitor and its use as a tuning element of an MRI surface coil at 63.8 MHz are described. It is found that image quality does not depend strongly on match of the coil to the transmission line but that tuning can be a significant factor. The work is intended to lead ev...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910120106

    authors: Hyde JS,Rilling RJ,Jesmanowicz A,Kneeland JB

    更新日期:1989-10-01 00:00:00

  • Materials and methods for higher performance screen-printed flexible MRI receive coils.

    abstract:PURPOSE:To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS:An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by scree...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26399

    authors: Corea JR,Lechene PB,Lustig M,Arias AC

    更新日期:2017-08-01 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Pattern recognition analysis of 1H NMR spectra from perchloric acid extracts of human brain tumor biopsies.

    abstract::Pattern recognition techniques (factor analysis and neural networks) were used to investigate and classify human brain tumors based on the 1H NMR spectra of chemically extracted biopsies (n = 118). After removing information from lactate (because of variable ischemia times), unsupervised learning suggested that the sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390604

    authors: Maxwell RJ,Martínez-Pérez I,Cerdán S,Cabañas ME,Arús C,Moreno A,Capdevila A,Ferrer E,Bartomeus F,Aparicio A,Conesa G,Roda JM,Carceller F,Pascual JM,Howells SL,Mazucco R,Griffiths JR

    更新日期:1998-06-01 00:00:00

  • Comparison between simulated decoupling regimes for specific absorption rate prediction in parallel transmit MRI.

    abstract:PURPOSE:The use of electromagnetic (EM) modeling is critical for specific absorption rate (SAR) characterization in parallel transmission MRI. Radiofrequency arrays that include decoupling networks can be difficult to characterize accurately in simulation. A practical method of simplifying modeling is to exclude the de...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25504

    authors: Beqiri A,Hand JW,Hajnal JV,Malik SJ

    更新日期:2015-11-01 00:00:00

  • Sodium NMR imaging of lung water in rats.

    abstract::Coronal proton and sodium images of control rats and rats with either increased permeability edema produced by intravenous alloxan (300 mg/kg) or increased pressure edema produced by saline infusion (2 ml/min) were obtained. Axial chest CT images were used to monitor the development of pulmonary edema. Immediately aft...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060403

    authors: Kundel HL,Shetty A,Joseph PM,Summers RM,Kassab EA,Moore B

    更新日期:1988-04-01 00:00:00

  • Spectroscopic imaging of glutamate C4 turnover in human brain.

    abstract::One-dimensional spectroscopic imaging of (13)C-4-glutamate turnover is performed in the human brain with a 6 cc nominal voxel resolution at 4T. Data were acquired with an indirect detection approach using a short spin echo single quantum (1)H-(13)C heteronuclear editing method and a 7 cm surface coil with quadrature (...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200011)44:5<673::aid-mrm3>3.0.co

    authors: Pan JW,Stein DT,Telang F,Lee JH,Shen J,Brown P,Cline G,Mason GF,Shulman GI,Rothman DL,Hetherington HP

    更新日期:2000-11-01 00:00:00

  • Robust water fat separated dual-echo MRI by phase-sensitive reconstruction.

    abstract:PURPOSE:The purpose of this work was to develop and evaluate a robust water-fat separation method for T1-weighted symmetric two-point Dixon data. THEORY AND METHODS:A method for water-fat separation by phase unwrapping of the opposite-phase images by phase-sensitive reconstruction (PSR) is introduced. PSR consists of ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26488

    authors: Romu T,Dahlström N,Leinhard OD,Borga M

    更新日期:2017-09-01 00:00:00