Development and optimization of hardware for delta relaxation enhanced MRI.

Abstract:

PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T superconducting system are systematically identified and mitigated. METHODS:The effects of nonideal fabrication of the field-shifting magnet are taken into consideration through careful measurement during winding and improved accuracy in the design of the associated active shield. The shielding performance of the resultant electromagnet is compared against a previously built system in which the shield design was based on an ideal primary coil model. Hardware and software approaches implemented to eliminate residual image artifacts are presented in detail. RESULTS:The eddy currents produced by the newly constructed dreMR system are shown to have a significantly smaller "long-time-constant" component, consistent with the hypothesis that less energy is deposited into the cryostat of the MR system. CONCLUSION:With active compensation, the dreMR imaging system is capable of 0.22T field shifts within a clinical 1.5T MRI with no significant residual eddy-current fields.

journal_name

Magn Reson Med

authors

Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

doi

10.1002/mrm.25014

subject

Has Abstract

pub_date

2014-10-01 00:00:00

pages

1182-90

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

72

pub_type

杂志文章
  • Correction for geometric distortion in echo planar images from B0 field variations.

    abstract::A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340111

    authors: Jezzard P,Balaban RS

    更新日期:1995-07-01 00:00:00

  • Ultrahigh-resolution quantitative spinal cord MRI at 9.4T.

    abstract:PURPOSE:To present the results of the first human spinal cord in vivo MRI scans at 9.4T. METHODS:A human brain coil was used to image the human spinal cord at 9.4T. All anatomical images were acquired with a T2 *-weighted gradient-echo sequence. A comparison of the influence of four different B0 shimming routines on t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28455

    authors: Geldschläger O,Bosch D,Avdievich NI,Henning A

    更新日期:2021-02-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    abstract:PURPOSE:Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26824

    authors: Zhang Z,Frydman L

    更新日期:2018-03-01 00:00:00

  • Analysis and correction of biases in cross-relaxation MRI due to biexponential longitudinal relaxation.

    abstract:PURPOSE:Cross-relaxation imaging (CRI) is a family of quantitative magnetization transfer techniques that utilize images obtained with off-resonance saturation and longitudinal relaxation rate (R1) maps reconstructed by the variable flip angle (VFA) method. It was demonstrated recently that a significant bias in an app...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24677

    authors: Mossahebi P,Yarnykh VL,Samsonov A

    更新日期:2014-02-01 00:00:00

  • Performance evaluation of whole-body NMR scanner antenna systems.

    abstract::Whole-body NMR imaging antennas (probes) are strongly affected by the inevitable magnetic and controllable dielectric losses. Using a convenient parallelepiped model, the magnetic losses are evaluated. By introducing the "ideal power gain," the best possible antenna performance is delimited as a function of the freque...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910020403

    authors: Sergiadis G

    更新日期:1985-08-01 00:00:00

  • On the use of Bayesian probability theory for analysis of exponential decay data: an example taken from intravoxel incoherent motion experiments.

    abstract::Traditionally, the method of nonlinear least squares (NLLS) analysis has been used to estimate the parameters obtained from exponential decay data. In this study, we evaluated the use of Bayesian probability theory to analyze such data; specifically, that resulting from intravoxel incoherent motion NMR experiments. An...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290510

    authors: Neil JJ,Bretthorst GL

    更新日期:1993-05-01 00:00:00

  • Oxygen extraction fraction mapping at 3 Tesla using an artificial neural network: A feasibility study.

    abstract:PURPOSE:The oxygen extraction fraction (OEF) is an important biomarker for tissue-viability. MRI enables noninvasive estimation of the OEF based on the blood-oxygenation-level-dependent (BOLD) effect. Quantitative OEF-mapping is commonly applied using least-squares regression (LSR) to an analytical tissue model. Howeve...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26749

    authors: Domsch S,Mürle B,Weingärtner S,Zapp J,Wenz F,Schad LR

    更新日期:2018-02-01 00:00:00

  • Reduction of B1 sensitivity in selective single-slab 3D turbo spin echo imaging with very long echo trains.

    abstract::Single-slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is vulnerable to image degradation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22070

    authors: Park J,Mugler JP 3rd,Hughes T

    更新日期:2009-10-01 00:00:00

  • Real-time measurements of cellular oxygen consumption, pH, and energy metabolism using nuclear magnetic resonance spectroscopy.

    abstract::Changes in molecular expression or apoptotic behavior, induced by malignant transformation or anticancer treatment, are frequently reflected in cellular metabolism and oxygen consumption. A technique to monitor oxygen consumption, cell physiology, and metabolism noninvasively would provide a better understanding of in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1102

    authors: Pilatus U,Aboagye E,Artemov D,Mori N,Ackerstaff E,Bhujwalla ZM

    更新日期:2001-05-01 00:00:00

  • Phase-labeled reference EPI for frequency-segmented inhomogeneity corrections (PREFICS).

    abstract:PURPOSE:To develop a method to correct for geometric distortions in non-Cartesian echo planar imaging using data acquired in a fast prescan. METHODS:Echo planar images were obtained using a non-Cartesian density weighted k-space trajectory. In contrast to linear Cartesian acquisition, distortions arising in non-Cartes...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24737

    authors: Zeller M,Müller A,Hahn D,Köstler H

    更新日期:2014-03-01 00:00:00

  • Chemically induced analgesic nephropathy in the rat monitored by proton-electron double-resonance imaging (PEDRI).

    abstract::Proton-electron double-resonance imaging (PEDRI) was used to assess renal function by monitoring the flow of the exogenous nitroxide free radical proxyl carboxylic acid (PCA) through normal and injured kidneys in the living rat. Kidney damage was induced by treatment with 2-bromoethylamine (BEA), which provides a well...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400214

    authors: Seimenis I,Foster MA,Lurie DJ,Hutchison JM,Whiting PH,Payne S

    更新日期:1998-08-01 00:00:00

  • Intracellular and extracellular spaces and the direct quantification of molar intracellular concentrations of phosphorus metabolites in the isolated rat heart using 31P NMR spectroscopy and phosphonate markers.

    abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320206

    authors: Clarke K,Anderson RE,Nédélec JF,Foster DO,Ally A

    更新日期:1994-08-01 00:00:00

  • Simple analytical dual-band spectral-spatial RF pulses for B(1) + and susceptibility artifact reduction in gradient echo MRI.

    abstract::Susceptibility artifacts and transmission radio frequency (RF) field (B(1) +) inhomogeneity are major limitations in high-field gradient echo MRI. Previously proposed numerical 2D spectral-spatial RF pulses have been shown to be promising for reducing the through-plane signal loss susceptibility artifact by incorporat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22725

    authors: Yang C,Deng W,Stenger VA

    更新日期:2011-02-01 00:00:00

  • Detection of liver fibrosis with magnetic cross-relaxation.

    abstract::The utility of MRI using magnetization transfer (MT) enhanced pulse sequences to diagnose hepatic cirrhosis in a rat model was investigated. Hepatic T1 was measured with and without MT off-resonance RF pulses in 17 treated and six control rats. The livers were evaluated histologically, and the hydroxyproline content q...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310513

    authors: Aisen AM,Doi K,Swanson SD

    更新日期:1994-05-01 00:00:00

  • Contributions of chemical exchange to T1ρ dispersion in a tissue model.

    abstract::Variations in T(1ρ) with locking-field strength (T(1ρ) dispersion) may be used to estimate proton exchange rates. We developed a novel approach utilizing the second derivative of the dispersion curve to measure exchange in a model system of cross-linked polyacrylamide gels. These gels were varied in relative compositi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22947

    authors: Cobb JG,Xie J,Gore JC

    更新日期:2011-12-01 00:00:00

  • Nonuniform and multidimensional Shinnar-Le Roux RF pulse design method.

    abstract::The Shinnar-Le Roux (SLR) radiofrequency (RF) pulse design algorithm is widely used for designing slice-selective RF pulses due to its intuitiveness, optimality, and speed. SLR is limited, however, in that it is only capable of designing one-dimensional pulses played along constant gradients. We present a nonuniform S...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23269

    authors: Grissom WA,McKinnon GC,Vogel MW

    更新日期:2012-09-01 00:00:00

  • Molecular imaging of angiogenic therapy in peripheral vascular disease with alphanubeta3-integrin-targeted nanoparticles.

    abstract::Noninvasive molecular imaging of angiogenesis could play a critical role in the clinical management of peripheral vascular disease patients. The alpha(nu)beta(3)-integrin, a well-established biomarker of neovascular proliferation, is an ideal target for molecular imaging of angiogenesis. This study investigates whethe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22447

    authors: Winter PM,Caruthers SD,Allen JS,Cai K,Williams TA,Lanza GM,Wickline SA

    更新日期:2010-08-01 00:00:00

  • In vivo GABA editing using a novel doubly selective multiple quantum filter.

    abstract::A novel multiple quantum filtering method is proposed that uses a doubly selective pulse termed Delays Alternating with Nutations for Tailored Excitation (DANTE) for multiple quantum preparation. This method selectively prepares GABA-3 and GABA-4 into a multiple quantum state and suppresses all other resonances at 3.0...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10104

    authors: Shen J,Rothman DL,Brown P

    更新日期:2002-03-01 00:00:00

  • In vivo measurements of bone marrow cellularity using volume-localized proton NMR spectroscopy.

    abstract::Volume-localized proton NMR spectroscopy was used to estimate bone marrow cellularity in the posterior iliac crests of patients undergoing treatment with hematopoietic growth factors for a variety of hematologic and neoplastic disorders. Twelve patients were accrued, six of whom were studied more than once, yielding a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190108

    authors: Ballon D,Jakubowski A,Gabrilove J,Graham MC,Zakowski M,Sheridan C,Koutcher JA

    更新日期:1991-05-01 00:00:00

  • Commutator filter: a novel technique for the identification of structures producing significant susceptibility inhomogeneities and its application to functional MRI.

    abstract::A robust postprocessing method to detect regions of magnetic field change is presented. High resolution gradient echo data is acquired to create a complex baseline image. From this image, two low resolution images are obtained by applying a low pass filter on the magnitude image and the complex image, respectively. Su...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360518

    authors: Lai S,Reichenbach JR,Haacke EM

    更新日期:1996-11-01 00:00:00

  • Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating.

    abstract::Four-dimensional (4D) flow imaging has been used to study flow patterns and pathophysiology, usually focused on specific thoracic vessels and cardiac chambers. Whole-heart 4D flow at high measurement accuracy covering the entire thoracic cardiovascular system would be desirable to simplify and improve hemodynamic asse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22090

    authors: Uribe S,Beerbaum P,Sørensen TS,Rasmusson A,Razavi R,Schaeffter T

    更新日期:2009-10-01 00:00:00

  • Application of parallel imaging to fMRI at 7 Tesla utilizing a high 1D reduction factor.

    abstract::Gradient-echo EPI, blood oxygenation level-dependent (BOLD) functional MRI (fMRI) using parallel imaging (PI) is demonstrated at 7 Tesla with 16 channels, a fourfold 1D reduction factor (R), and fourfold maximal aliasing. The resultant activation detection in finger-tapping fMRI studies was robust, in full agreement w...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20934

    authors: Moeller S,Van de Moortele PF,Goerke U,Adriany G,Ugurbil K

    更新日期:2006-07-01 00:00:00

  • Optimized saturation pulse train for human first-pass myocardial perfusion imaging at 7T.

    abstract:PURPOSE:To investigate whether saturation using existing methods developed for 3T imaging is feasible for clinical perfusion imaging at 7T, and to propose a new design of saturation pulse train for first-pass myocardial perfusion imaging at 7T. METHODS:The new design of saturation pulse train consists of four hyperbol...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25262

    authors: Tao Y,Hess AT,Keith GA,Rodgers CT,Liu A,Francis JM,Neubauer S,Robson MD

    更新日期:2015-04-01 00:00:00

  • Parallel MRI reconstruction using variance partitioning regularization.

    abstract::Multiple receivers can be utilized to enhance the spatiotemporal resolution of MRI by employing the parallel imaging technique. Previously, we have reported the L-curve Tikhonov regularization technique to mitigate noise amplification resulting from the geometrical correlations between channels in a coil array. Nevert...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21356

    authors: Lin FH,Wang FN,Ahlfors SP,Hämäläinen MS,Belliveau JW

    更新日期:2007-10-01 00:00:00

  • Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle.

    abstract:PURPOSE:To establish a series of relationships defining how muscle microstructure and diffusion tensor imaging (DTI) are related. METHODS:The relationship among key microstructural features of skeletal muscle (fiber size, fibrosis, edema, and permeability) and the diffusion tensor were systematically simulated over ph...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26993

    authors: Berry DB,Regner B,Galinsky V,Ward SR,Frank LR

    更新日期:2018-07-01 00:00:00

  • Robust abdominal imaging with incomplete breath-holds.

    abstract:PURPOSE:Breath-holding is an established strategy for reducing motion artifacts in abdominal imaging. However, the breath-holding capabilities of patients are often overstrained by scans with large coverage and high resolution. In this work, a new strategy for coping with resulting incomplete breath-holds in abdominal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24829

    authors: Gdaniec N,Eggers H,Börnert P,Doneva M,Mertins A

    更新日期:2014-05-01 00:00:00

  • Determination of extracellular/intracellular fluid ratios from magnetic resonance images: accuracy, feasibility, and implementation.

    abstract::This study determines the accuracy and feasibility of using localized spin-lattice (T1) relaxation time measurements from magnetic resonance (MR) images to follow changes in extracellular/intracellular fluid ratios in defined subvolumes of living tissue. A red blood cell suspension was used as a test system and a simp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910150107

    authors: Martin MA,Tatton WG,Lemaire C,Armstrong RL

    更新日期:1990-07-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T.

    abstract::This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20866

    authors: Herold V,Mörchel P,Faber C,Rommel E,Haase A,Jakob PM

    更新日期:2006-05-01 00:00:00