In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T.

Abstract:

:This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired at three different levels in the murine myocardium with an in-plane resolution of 98 mum, a slice thickness of 0.6 mm, and a temporal resolution of 6 ms. The applied PC-MRI method was validated with phantom experiments that confirmed the correctness of the method with deviations of <1.7%. Myocardial in-plane velocities between 0.5 cm/s and 2.2 cm/s were determined for the healthy murine myocardium. Through-plane velocities of 0.1-0.83 cm/s were measured. Velocity data was also used to calculate the myocardial twist angle during systole at different slices in the short-axis view.

journal_name

Magn Reson Med

authors

Herold V,Mörchel P,Faber C,Rommel E,Haase A,Jakob PM

doi

10.1002/mrm.20866

subject

Has Abstract

pub_date

2006-05-01 00:00:00

pages

1058-64

issue

5

eissn

0740-3194

issn

1522-2594

journal_volume

55

pub_type

杂志文章
  • Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.

    abstract::The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<53::aid-mrm9>3

    authors: de Zwart JA,Vimeux FC,Delalande C,Canioni P,Moonen CT

    更新日期:1999-07-01 00:00:00

  • Joint image reconstruction and sensitivity estimation in SENSE (JSENSE).

    abstract::Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enhancement achievable with the tec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21245

    authors: Ying L,Sheng J

    更新日期:2007-06-01 00:00:00

  • Convex gradient optimization for increased spatiotemporal resolution and improved accuracy in phase contrast MRI.

    abstract:PURPOSE:To evaluate convex gradient optimization (CVX) for increased spatiotemporal resolution and improved accuracy for phase-contrast MRI (PC-MRI). METHODS:A conventional flow-compensated and flow-encoded (FCFE) PC-MRI sequence was compared with a CVX PC-MRI sequence using numerical simulations, flow phantom experim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25059

    authors: Middione MJ,Wu HH,Ennis DB

    更新日期:2014-12-01 00:00:00

  • Arterial spin labeling perfusion fMRI with very low task frequency.

    abstract::Functional magnetic resonance imaging (fMRI) has become the most widely used modality for visualizing regional brain activation in response to sensorimotor or cognitive tasks. While the majority of fMRI studies have used blood oxygenation level-dependent (BOLD) contrast as a marker for neural activation, baseline drif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10437

    authors: Wang J,Aguirre GK,Kimberg DY,Roc AC,Li L,Detre JA

    更新日期:2003-05-01 00:00:00

  • Fast diffusion imaging with high angular resolution.

    abstract:PURPOSE:High angular resolution diffusion imaging (HARDI) is a well-established method to help reveal the architecture of nerve bundles, but long scan times and geometric distortions inherent to echo planar imaging (EPI) have limited its integration into clinical protocols. METHODS:A fast imaging method is proposed he...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26163

    authors: Chao TC,Chiou JG,Maier SE,Madore B

    更新日期:2017-02-01 00:00:00

  • A reduced field-of-view method to increase temporal resolution or reduce scan time in cine MRI.

    abstract::In some dynamic applications of MRI, only a part of the field-of-view (FOV) actually undergoes dynamic changes. A class of methods, called reduced-FOV (rFOV) methods, convert the knowledge that some part of the FOV is static or not very dynamic into an increase in temporal resolution for the dynamic part, or into a re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200004)43:4<549::aid-mrm9>

    authors: Madore B,Fredrickson JO,Alley MT,Pelc NJ

    更新日期:2000-04-01 00:00:00

  • High-resolution quantitative sodium imaging at 9.4 Tesla.

    abstract:PURPOSE:Investigation of the feasibility to perform high-resolution quantitative sodium imaging at 9.4 Tesla (T). METHODS:A proton patch antenna was combined with a sodium birdcage coil to provide a proton signal without compromising the efficiency of the X-nucleus coil. Sodium density weighted images with a nominal r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25096

    authors: Mirkes CC,Hoffmann J,Shajan G,Pohmann R,Scheffler K

    更新日期:2015-01-01 00:00:00

  • Fully balanced steady-state 3D-spin-echo (bSSSE) imaging at 3 Tesla.

    abstract::In this work a 3D fully balanced steady-state spin-echo sequence (bSSSE) was designed and implemented on a 3-Tesla whole-body MR scanner. In contrast to previously introduced nonbalanced SSSE (nbSSSE) sequences, bSSSE features fully rewound imaging gradients. Additionally, all phase encodings and the readout prephasin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21037

    authors: Krug R,Han ET,Banerjee S,Majumdar S

    更新日期:2006-11-01 00:00:00

  • The use of band-selectable digital filtering in magnetic resonance image enhancement.

    abstract::Manipulation of the data describing two-dimensional magnetic resonance (MR) images can be used to zoom an image, decrease image noise and artifacts by modeling, or emphasize object edges in the field of view. In this paper, a two-dimensional band-selectable digital filtering (2D-BSDF) technique is detailed. This can b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090307

    authors: Mitchell DK,Nichols ST,Smith MR,Scott K

    更新日期:1989-03-01 00:00:00

  • Measuring extracellular volume fraction by MRI: First verification of values given by clinical sequences.

    abstract:PURPOSE:To verify MR measurements of myocardial extracellular volume fraction (ECV) based on clinically applicable T1-mapping sequences against ECV measurements by radioisotope tracer in pigs and to relate the results to those obtained in volunteers. METHODS:Between May 2016 and March 2017, 8 volunteers (25 ± 4 years,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27938

    authors: Nordlund D,Xanthis C,Bidhult S,Jablonowski R,Kanski M,Kopic S,Carlsson M,Engblom H,Aletras AH,Arheden H

    更新日期:2020-02-01 00:00:00

  • Quantitative proton magnetic resonance spectroscopy of the human cervical spinal cord at 3 Tesla.

    abstract::Cervical spinal cord spectroscopy has the potential to add metabolic information to spinal cord MRI and improve the clinical evaluation and research investigation of spinal cord diseases, such as multiple sclerosis (MS) and intraspinal tumors. However, in vivo proton MR spectroscopy ((1)H-MRS) of the spinal cord is di...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21113

    authors: Marliani AF,Clementi V,Albini-Riccioli L,Agati R,Leonardi M

    更新日期:2007-01-01 00:00:00

  • Variable echo time imaging: signal characteristics of 1-M gadobutrol contrast agent at 1.5 and 3T.

    abstract::Gadobutrol (Gd-Bt; Gadovist(R), Schering AG) is a 1-M Gadolinium (Gd)-based contrast agent. Its higher Gd concentration allows for reduction of injection volumes in first pass contrast-enhanced MR angiography (CE-MRA) and should increase bolus sharpness and image quality. However, ambivalent results were reported. In ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21345

    authors: Stalder AF,Elverfeldt DV,Paul D,Hennig J,Markl M

    更新日期:2008-01-01 00:00:00

  • Evaluation of fluorine-19 magnetic resonance imaging of the lungs using octafluorocyclobutane in a rat model.

    abstract:PURPOSE:To test octafluorocyclobutane (OFCB) as an inhalation contrast agent for fluorine-19 MRI of the lung, and to compare the image quality of OFCB scans with perfluoropropane (PFP) scans THEORY AND METHODS: After normalizing for the number of signal averages, a theoretical comparison between the OFCB signal-to-nois...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28473

    authors: Shepelytskyi Y,Li T,Grynko V,Newman C,Hane FT,Albert MS

    更新日期:2021-02-01 00:00:00

  • Probing treatment response of glutaminolytic prostate cancer cells to natural drugs with hyperpolarized [5-(13) C]glutamine.

    abstract:PURPOSE:The correlation between glutamine metabolism and oncogene expression in cancers has led to a renewed interest in the role of glutamine in cancer cell survival. Hyperpolarized [5-(13) C]glutamine is evaluated as a potential biomarker for noninvasive metabolic measurements of drug response in prostate cancer cell...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25360

    authors: Canapè C,Catanzaro G,Terreno E,Karlsson M,Lerche MH,Jensen PR

    更新日期:2015-06-01 00:00:00

  • Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating.

    abstract::Four-dimensional (4D) flow imaging has been used to study flow patterns and pathophysiology, usually focused on specific thoracic vessels and cardiac chambers. Whole-heart 4D flow at high measurement accuracy covering the entire thoracic cardiovascular system would be desirable to simplify and improve hemodynamic asse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22090

    authors: Uribe S,Beerbaum P,Sørensen TS,Rasmusson A,Razavi R,Schaeffter T

    更新日期:2009-10-01 00:00:00

  • SENSE reconstruction for multiband EPI including slice-dependent N/2 ghost correction.

    abstract:PURPOSE:Sensitivity encoding (SENSE) reconstruction of multiband echo planar imaging (EPI) may cause artifacts when simultaneously excited slices require different phase correction to remove the EPI-specific ghost shifted by half of the matrix size (N). We propose a simplified solution of this problem that combines SEN...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25915

    authors: Hennel F,Buehrer M,von Deuster C,Seuven A,Pruessmann KP

    更新日期:2016-09-01 00:00:00

  • Correction for geometric distortion in echo planar images from B0 field variations.

    abstract::A method is described for the correction of geometric distortions occurring in echo planar images. The geometric distortions are caused in large part by static magnetic field inhomogeneities, leading to pixel shifts, particularly in the phase encode direction. By characterizing the field inhomogeneities from a field m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340111

    authors: Jezzard P,Balaban RS

    更新日期:1995-07-01 00:00:00

  • Image reconstruction using a gradient impulse response model for trajectory prediction.

    abstract:PURPOSE:Gradient imperfections remain a challenge in MRI, especially for sequences relying on long imaging readouts. This work aims to explore image reconstruction based on k-space trajectories predicted by an impulse response model of the gradient system. THEORY AND METHODS:Gradient characterization was performed twi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25841

    authors: Vannesjo SJ,Graedel NN,Kasper L,Gross S,Busch J,Haeberlin M,Barmet C,Pruessmann KP

    更新日期:2016-07-01 00:00:00

  • Accurate quantification of in vivo 31P NMR signals using the variable projection method and prior knowledge.

    abstract::Free induction decay signals are analyzed by fitting a model function directly in the time domain. No starting values are needed for linear model parameters, and omission of corrupted data points poses no problems. A significant gain of accuracy is achieved by imposing prior knowledge about the model parameters. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060111

    authors: van der Veen JW,de Beer R,Luyten PR,van Ormondt D

    更新日期:1988-01-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00

  • Simultaneous quantitative mapping of conductivity and susceptibility using a double-echo ultrashort echo time sequence: Example using a hematoma evolution study.

    abstract:PURPOSE:The primary purpose of this study is to propose a method for the simultaneous quantitative three-dimensional (3D) mapping of conductivity and susceptibility using double-echo ultrashort echo time (UTE) imaging. The secondary purpose is to investigate the changes of these properties over time during in vitro hem...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25869

    authors: Gho SM,Shin J,Kim MO,Kim DH

    更新日期:2016-07-01 00:00:00

  • Proton high-resolution magic angle spinning NMR analysis of fresh and previously frozen tissue of human prostate.

    abstract::The previously observed improvement in spectral resolution of tissue proton NMR with high-resolution magic angle spinning (HRMAS) was speculated to be due largely to freeze-thawing artifacts resulting from tissue storage. In this study, 12 human prostate samples were analyzed on a 14.1T spectrometer at 3 degrees C, wi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10645

    authors: Wu CL,Taylor JL,He W,Zepeda AG,Halpern EF,Bielecki A,Gonzalez RG,Cheng LL

    更新日期:2003-12-01 00:00:00

  • S5FP: spectrally selective suppression with steady state free precession.

    abstract::A method is presented that employs the inherent spectral selectivity of the Steady-State Free Precession (SSFP) pulse sequence to provide a spectral band of suppression. At TE = TR/2, SSFP partitions the magnetization into two phase-opposed spectral components. Z-storing one of these components simultaneously further ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20633

    authors: Derbyshire JA,Herzka DA,McVeigh ER

    更新日期:2005-10-01 00:00:00

  • Transcatheter intra-arterial perfusion (TRIP)-MRI biomarkers help detect immediate response to irreversible electroporation of rabbit VX2 liver tumor.

    abstract:PURPOSE:Irreversible electroporation (IRE) is a nonthermal tissue ablation technique that represents a promising treatment option for unresectable liver tumors, but the effectively treated zone cannot be reliably predicted. We investigate the potential benefit of transcatheter intra-arterial perfusion (TRIP) -MRI for t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28104

    authors: Figini M,Zhou K,Pan L,Sun C,Wang B,Hu S,Yang J,Shangguan J,Eresen A,Velichko Y,Yaghmai V,Zhang Z

    更新日期:2020-07-01 00:00:00

  • Deconvolution-based distortion correction of EPI using analytic single-voxel point-spread functions.

    abstract:PURPOSE:To develop a postprocessing algorithm that corrects geometric distortions due to spatial variations of the static magnetic field amplitude, B0 , and effects from relaxation during signal acquisition in EPI. THEORY AND METHODS:An analytic, complex point-spread function is deduced for k-space trajectories of EPI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28591

    authors: Patzig F,Mildner T,Schlumm T,Müller R,Möller HE

    更新日期:2020-11-21 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Differentiation of human tumors from nonmalignant tissue by natural-abundance 13C NMR spectroscopy.

    abstract::High-quality, high-resolution, proton-decoupled natural-abundance 13C NMR spectra have been obtained in vitro at 100.6 MHz from unprocessed human pathology specimens of tumors and adjacent nonneoplastic control tissues from lung, colon, and prostate. In these preliminary studies, specific molecular parameters were ide...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070403

    authors: Halliday KR,Fenoglio-Preiser C,Sillerud LO

    更新日期:1988-08-01 00:00:00

  • Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution.

    abstract::The feasibility of reconstructing three-dimensional (3D) MRI data sets from limited-view projections is investigated in phantom and in vivo animal studies to improve the temporal resolution of magnetic resonance angiography without sacrificing spatial resolution. Thirty-two pairs of orthogonal biplane projections are ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20727

    authors: Huang Y,Gurr D,Wright GA

    更新日期:2006-01-01 00:00:00

  • 31P nuclear magnetic resonance study of acute renal dysfunction in rat kidney transplants.

    abstract::31P NMR spectroscopy was used to study renal allografts in rats subjected to allograft rejection, cyclosporine toxicity, ischemia, and ureteral obstruction. Parameters of relative peak areas and intracellular pH were accurately distinguished among the different causes of graft dysfunction. Ureteral obstruction was cle...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050405

    authors: Shapiro JI,Haug CE,Weil R 3rd,Chan L

    更新日期:1987-10-01 00:00:00

  • Diffusion tensor imaging using single-shot SENSE-EPI.

    abstract::SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10184

    authors: Bammer R,Auer M,Keeling SL,Augustin M,Stables LA,Prokesch RW,Stollberger R,Moseley ME,Fazekas F

    更新日期:2002-07-01 00:00:00