Abstract:
:In some dynamic applications of MRI, only a part of the field-of-view (FOV) actually undergoes dynamic changes. A class of methods, called reduced-FOV (rFOV) methods, convert the knowledge that some part of the FOV is static or not very dynamic into an increase in temporal resolution for the dynamic part, or into a reduction in the scan time. Although cardiac imaging is an important example of an imaging situation where changes are concentrated in a fraction of the FOV, the rFOV methods developed up to now are not compatible with one of the most common cardiac sequences, the so-called retrospective cine method. The present work is a rFOV method designed to be compatible with cine imaging. An increase by a factor n in temporal resolution or a decrease by n in scan time is obtained in the case where only one nth of the FOV is dynamic (the rest being considered static). Results are presented for both Cartesian and spiral imaging.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Madore B,Fredrickson JO,Alley MT,Pelc NJdoi
10.1002/(sici)1522-2594(200004)43:4<549::aid-mrm9>subject
Has Abstractpub_date
2000-04-01 00:00:00pages
549-58issue
4eissn
0740-3194issn
1522-2594pii
10.1002/(SICI)1522-2594(200004)43:4<549::AID-MRM9>journal_volume
43pub_type
杂志文章abstract:PURPOSE:Magnetization transfer in white matter (WM) causes biexponential relaxation, but most quantitative T1 measurements fit data assuming monoexponential relaxation. The resulting monoexponential T1 estimate varies based on scan parameters and represents a source of variation between studies, especially at high fiel...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25729
更新日期:2016-06-01 00:00:00
abstract::A method is presented for measuring myocardial deformation in a breath-hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16- to 64-fold from previous techniques. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910280214
更新日期:1992-12-01 00:00:00
abstract:PURPOSE:Magnetic resonance elastography (MRE) measures stiffness of soft tissues by analyzing their spatial harmonic response to externally induced shear vibrations. Many MRE methods use inversion-based reconstruction approaches, which invoke first- or second-order derivatives by finite difference operators (first- and...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28247
更新日期:2020-07-01 00:00:00
abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910320206
更新日期:1994-08-01 00:00:00
abstract::Strong, extensive magnetic fringe fields are a significant problem with magnetic resonance imaging magnets. This is particularly acute with 4-T, whole-body research magnets. To date this problem has been addressed by restricting an extensive zone around the unshielded magnet or by placing external unsaturated iron shi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910290107
更新日期:1993-01-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) has recently been adopted as an investigational tool in the field of neuroscience. The signal changes induced by brain activations are small ( approximately 1-2%) at 1.5T. Therefore, the signal-to-noise ratio (SNR) of the time series used to calculate the functional maps is...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200012)44:6<925::aid-mrm14>3.0.c
更新日期:2000-12-01 00:00:00
abstract::Current implementations of coronary artery magnetic resonance angiography (MRA) suffer from limited coverage of the coronary arterial system. Whole-heart coronary MRA was implemented based on a free-breathing steady-state free-precession (SSFP) technique with magnetization preparation. The technique was compared to a ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10653
更新日期:2003-12-01 00:00:00
abstract::The reconstruction of non-Cartesian k-space trajectories often requires the estimation of nonuniform sampling density. Particularly for 3D, this calculation can be computationally expensive. The method proposed in this work combines an iterative algorithm previously proposed by Pipe and Menon (Magn Reson Med 1999;41:1...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23041
更新日期:2012-03-01 00:00:00
abstract::Adipose tissue as well as other depots of fat (triglycerides) are increasingly being recognized as active contributors to the human function and metabolism. In addition to the fat concentration, also the fatty acid chemical composition (FAC) of the triglyceride molecules may play an important part in diseases such as ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,评审
doi:10.1002/mrm.28471
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:The goal of this study was to measure and compare the apparent transverse relaxation time constants (T2 ) of five intracellular metabolites using localization by adiabatic selective refocusing (LASER) and point-resolved spectroscopy (PRESS) sequences in the human brain at 3 T. METHODS:Five healthy subjects wer...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26826
更新日期:2018-03-01 00:00:00
abstract:PURPOSE:To develop a practical method for mapping macromolecule distribution in the brain using ultrashort-TE MRSI data. METHODS:An FID-based chemical shift imaging acquisition without metabolite-nulling pulses was used to acquire ultrashort-TE MRSI data that capture the macromolecule signals with high signal-to-noise...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26896
更新日期:2018-05-01 00:00:00
abstract::A novel and automated technique is described for removing fMRI image artifacts resulting from motion outside of the imaging field of view. The technique is based on the Stockwell transform (ST), a mathematical operation that provides the frequency content at each time point within a time-varying signal. Using this tec...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10681
更新日期:2004-01-01 00:00:00
abstract::Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the superior/inferior (S/I) direction, t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21260
更新日期:2007-07-01 00:00:00
abstract::An optimized multislice data acquisition scheme for phase acquisition of composite echoes (PACE) imaging is presented. This new scheme uses a repetition time equal to the mixing time and an appropriate phase cycling scheme, which allows for more efficient exploitation of all composite echoes. These modifications provi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199912)42:6<1089::aid-mrm1
更新日期:1999-12-01 00:00:00
abstract::A new volume selection/spectral editing pulse sequence (VOSING) is presented. The features specific to the technique are that the volume selection and the editing intervals coincide and that no decoupling is necessary. The pulse sequence can be applied under both homo- and heteronuclear conditions. Phantom experiments...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910080108
更新日期:1988-09-01 00:00:00
abstract::In radiotherapy, target tissues are defined best on MR images due to their superior soft tissue contrast. Computed tomography imaging is geometrically accurate and it is needed for dose calculation and generation of reference images for treatment localization. Co-registration errors between MR and computed tomography ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,随机对照试验
doi:10.1002/mrm.24459
更新日期:2013-07-01 00:00:00
abstract:PURPOSE:The aim of this study was to develop a technique for rapid collection of chemical exchange saturation transfer images with the saturation varied to modulate signal loss transfer and enhance contrast. METHODS:Multi-echo Length and Offset VARied Saturation (MeLOVARS) divides the saturation pulse of length Tsat i...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25567
更新日期:2015-02-01 00:00:00
abstract:PURPOSE:Spiral-based trajectories for magnetic resonance imaging can be advantageous, but are often cumbersome to design or create. This work presents a flexible numerical algorithm for designing trajectories based on explicit definition of radial undersampling, and also gives several analytical expressions for charact...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24675
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:Diffusion-weighted magnetic resonance imaging suffers from physiological noise, such as artifacts caused by motion or system instabilities. Therefore, there is a need for robust diffusion parameter estimation techniques. In the past, several techniques have been proposed, including RESTORE and iRESTORE (Chang e...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25351
更新日期:2015-06-01 00:00:00
abstract:PURPOSE:Nicotinamide adenine dinucleotide (NAD), in oxidized (NAD(+) ) or reduced (NADH) form, plays key roles in cellular metabolism. Intracellular NAD(+) /NADH ratio represents the cellular redox state; however, it is difficult to measure in vivo. We report here a novel in vivo (31) P MRS method for noninvasive measu...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24859
更新日期:2014-06-01 00:00:00
abstract::MR acoustic, or sound, noise due to gradient pulsing has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources that obscures the small signals obtainable ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390224
更新日期:1998-02-01 00:00:00
abstract::In vivo echo-planar MR imaging was used to measure apparent diffusion coefficients (ADC) of cerebral tissues in a comprehensive noninvasive evaluation of early ischemic brain damage induced by occlusion of the middle cerebral artery (MCA) in a cat model of acute regional stroke. Within 10 min after arterial occlusion,...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910190220
更新日期:1991-06-01 00:00:00
abstract:PURPOSE:To accelerate the acquisition of J-resolved proton magnetic resonance spectroscopic imaging (1 H-MRSI) data for high-resolution mapping of brain metabolites and neurotransmitters. METHODS:The proposed method used a subspace model to represent multidimensional spatiospectral functions, which significantly reduc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28413
更新日期:2021-01-01 00:00:00
abstract::Cortical bone in the mature skeleton has a short T(2)* and produces no detectable signal with conventional MR sequences. A two-dimensional ultrashort echo time (UTE) sequence employing half radio frequency (RF) pulse excitations and radial ramp sampling reduces the effective TE to 8 micros and is capable of detecting ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21397
更新日期:2007-11-01 00:00:00
abstract::A gradient coil design algorithm capable of controlling the position of the homogeneous region of interest (ROI) with respect to the current-carrying wires is required for many advanced imaging and spectroscopy applications. A modified minimum inductance target field method that allows the placement of a set of constr...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910390214
更新日期:1998-02-01 00:00:00
abstract::Regional values of fractional anisotropy (FA) and mean diffusivity (D(av)) of in vivo and excised rat spinal cords were measured using an iscosahedral encoding scheme that is based on 21 uniformly distributed and alternating gradient directions with an echo planar imaging (EPI) readout. Based on the water phantom stud...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20304
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:To measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffus...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26969
更新日期:2018-06-01 00:00:00
abstract::Skeletal muscle triglycerides are markers for insulin resistance in type 2 diabetes. Recently, MR spectroscopy was adapted for in vivo measurement of triglycerides in animal models and for the characterization of new therapeutic approaches. Because of small MR spectroscopy voxel sizes used in skeletal muscles, surface...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.22149
更新日期:2009-10-01 00:00:00
abstract::A novel ultra-rapid gradient echo (URGE) NMR imaging technique is introduced, which is capable of continuous high resolution 3D scanning while neither subject to fast gradient switching nor excessive RF power deposition. Sampling free induction decays instead of creating spin echoes enables maintaining a workable stea...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910330123
更新日期:1995-01-01 00:00:00
abstract:PURPOSE:Atherosclerotic carotid plaques can be quantified in vivo by MRI. However, the accuracy in segmentation and quantification of components such as the thin fibrous cap (FC) and lipid-rich necrotic core (LRNC) remains unknown due to the lack of a submillimeter scale ground truth. METHODS:A novel approach was take...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.24905
更新日期:2014-07-01 00:00:00