Evaluation of fluorine-19 magnetic resonance imaging of the lungs using octafluorocyclobutane in a rat model.

Abstract:

PURPOSE:To test octafluorocyclobutane (OFCB) as an inhalation contrast agent for fluorine-19 MRI of the lung, and to compare the image quality of OFCB scans with perfluoropropane (PFP) scans THEORY AND METHODS: After normalizing for the number of signal averages, a theoretical comparison between the OFCB signal-to-noise ratio (SNR) and PFP SNR predicted the average SNR advantage of 90% using OFCB during gradient echo imaging. The OFCB relaxometry was conducted using single-voxel spectroscopy and spin-echo imaging. A comparison of OFCB and PFP SNRs was performed in vitro and in vivo. Five healthy Sprague-Dawley rats were imaged during single breath-hold and continuous breathing using a Philips Achieva 3.0T MRI scanner (Philips, Andover, MA). The scan time was constant for both gases. Statistical comparison between PFP and OFCB scans was conducted using a paired t test and by calculating the Bayes factor. RESULTS:Spin-lattice (T1 ) and effective spin-spin ( T 2 ∗ ) relaxation time constants of the pure OFCB gas were determined as 28.5 ± 1.2 ms and 10.5 ± 1.8 ms, respectively. Mixing with 21% of oxygen decreased T1 by 30% and T 2 ∗ by 20%. The OFCB in vivo images showed 73% higher normalized SNR on average compared with images acquired using PFP. The statistical significance was shown by both paired t test and calculated Bayes factors. The experimental results agree with theoretical calculations within the error of the relaxation parameter measurements. CONCLUSION:The quality of the lung images acquired using OFCB was significantly better compared with PFP scans. The OFCB images had higher a SNR and were artifact-free.

journal_name

Magn Reson Med

authors

Shepelytskyi Y,Li T,Grynko V,Newman C,Hane FT,Albert MS

doi

10.1002/mrm.28473

subject

Has Abstract

pub_date

2021-02-01 00:00:00

pages

987-994

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

85

pub_type

杂志文章
  • Flow-gated phase-contrast MRI using radial acquisitions.

    abstract::Phase-contrast (PC) MRI is a noninvasive method for imaging blood and tissue velocity. PC experiments are typically segmented into many cardiac cycles in order to obtain sufficient spatial and temporal resolution, and thus require a gating signal to properly combine the data from multiple cardiac cycles. Although the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20187

    authors: Thompson RB,McVeigh ER

    更新日期:2004-09-01 00:00:00

  • Model-based mapping of fat unsaturation and chain length by chemical shift imaging--phantom validation and in vivo feasibility.

    abstract::Knowledge about the triglyceride (fat) (1)H spectrum enables quantitative determination of several triglyceride characteristics. This work describes a model-based chemical shift imaging method that separates water and fat signal and provides maps of three triglyceride quantities: fatty acid carbon chain length, unsatu...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24196

    authors: Berglund J,Ahlström H,Kullberg J

    更新日期:2012-12-01 00:00:00

  • Selection and evaluation of optimal two-dimensional CAIPIRINHA kernels applied to time-resolved three-dimensional CE-MRA.

    abstract:PURPOSE:To develop and validate a method for choosing the optimal two-dimensional CAIPIRINHA kernel for subtraction contrast-enhanced MR angiography (CE-MRA) and estimate the degree of image quality improvement versus that of some reference acceleration parameter set at R ≥ 8. METHODS:A metric based on patient-specifi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25366

    authors: Weavers PT,Borisch EA,Riederer SJ

    更新日期:2015-06-01 00:00:00

  • Development and optimization of hardware for delta relaxation enhanced MRI.

    abstract:PURPOSE:Delta relaxation enhanced magnetic resonance (dreMR) imaging requires an auxiliary B0 electromagnet capable of shifting the main magnetic field within a clinical 1.5 Tesla (T) MR system. In this work, the main causes of interaction between an actively shielded, insertable resistive B0 electromagnet and a 1.5T s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25014

    authors: Harris CT,Handler WB,Araya Y,Martínez-Santiesteban F,Alford JK,Dalrymple B,Van Sas F,Chronik BA,Scholl TJ

    更新日期:2014-10-01 00:00:00

  • Self-degrading, MRI-detectable hydrogel sensors with picomolar target sensitivity.

    abstract::Nanostructured hydrogels have been developed as synthetic tissues and scaffolds for cell and drug delivery, and as guides for tissue regeneration. A fundamental problem in the development of synthetic hydrogels is that implanted gel structure is difficult to monitor noninvasively. This work demonstrates that the aggre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22570

    authors: Colomb J,Louie K,Massia SP,Bennett KM

    更新日期:2010-12-01 00:00:00

  • Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone.

    abstract::Cortical bone in the mature skeleton has a short T(2)* and produces no detectable signal with conventional MR sequences. A two-dimensional ultrashort echo time (UTE) sequence employing half radio frequency (RF) pulse excitations and radial ramp sampling reduces the effective TE to 8 micros and is capable of detecting ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21397

    authors: Du J,Hamilton G,Takahashi A,Bydder M,Chung CB

    更新日期:2007-11-01 00:00:00

  • Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.

    abstract:PURPOSE:Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS:MR acquisition consiste...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25017

    authors: Celicanin Z,Auboiroux V,Bieri O,Petrusca L,Santini F,Viallon M,Scheffler K,Salomir R

    更新日期:2014-10-01 00:00:00

  • Diffusion-weighted imaging of the human optic nerve: a new approach to evaluate optic neuritis in multiple sclerosis.

    abstract::The apparent diffusion coefficient (ADC) in the optic nerve was measured from diffusion-weighted magnetic resonance imaging using an intravoxel incoherent motion (IVIM) sequence. The subjects were seven normal volunteers and eight patients with multiple sclerosis (MS) with a total of four optic nerves with acute neuri...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380317

    authors: Iwasawa T,Matoba H,Ogi A,Kurihara H,Saito K,Yoshida T,Matsubara S,Nozaki A

    更新日期:1997-09-01 00:00:00

  • MR angiography by selective inversion recovery.

    abstract::A modified inversion-recovery sequence is introduced which performs subtraction angiography by varying time-of-flight effects of blood flowing into an imaged slab. The selective 180 degrees excitation inverts different regions between measurements to isolate arterial and/or venous blood. On normal human subjects, high...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910040214

    authors: Nishimura DG,Macovski A,Pauly JM,Conolly SM

    更新日期:1987-02-01 00:00:00

  • In vivo MR imaging and spectroscopy using hyperpolarized 129Xe.

    abstract::Hyperpolarized 129Xe has been used to obtain gas phase images of mouse lung in vivo, showing distinct ventilation variation as a function of the breathing cycle. Spectra of 129Xe in the thorax show complex structure in both the gas phase (-4 to 3 ppm) and tissue-dissolved (190-205 ppm) regions. The alveolar gas peak s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360203

    authors: Wagshul ME,Button TM,Li HF,Liang Z,Springer CS,Zhong K,Wishnia A

    更新日期:1996-08-01 00:00:00

  • Fully automated patellofemoral MRI segmentation using holistically nested networks: Implications for evaluating patellofemoral osteoarthritis, pain, injury, pathology, and adolescent development.

    abstract:PURPOSE:Our clinical understanding of the relationship between 3D bone morphology and knee osteoarthritis, as well as our ability to investigate potential causative factors of osteoarthritis, has been hampered by the time-intensive nature of manually segmenting bone from MR images. Thus, we aim to develop and validate ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27920

    authors: Cheng R,Alexandridi NA,Smith RM,Shen A,Gandler W,McCreedy E,McAuliffe MJ,Sheehan FT

    更新日期:2020-01-01 00:00:00

  • Robust abdominal imaging with incomplete breath-holds.

    abstract:PURPOSE:Breath-holding is an established strategy for reducing motion artifacts in abdominal imaging. However, the breath-holding capabilities of patients are often overstrained by scans with large coverage and high resolution. In this work, a new strategy for coping with resulting incomplete breath-holds in abdominal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24829

    authors: Gdaniec N,Eggers H,Börnert P,Doneva M,Mertins A

    更新日期:2014-05-01 00:00:00

  • Changes in T2*-weighted images during hyperoxia differentiate tumors from normal tissue.

    abstract::Experiments were performed to determine whether changes in T2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recyc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330306

    authors: Kuperman VYu,River JN,Lewis MZ,Lubich LM,Karczmar GS

    更新日期:1995-03-01 00:00:00

  • Intracellular and extracellular spaces and the direct quantification of molar intracellular concentrations of phosphorus metabolites in the isolated rat heart using 31P NMR spectroscopy and phosphonate markers.

    abstract::To quantify metabolite and cation concentrations using NMR spectroscopy, the volumes of intracellular and extracellular spaces must be known. We describe a simple 31P NMR spectroscopic method that employs dimethyl methylphosphonate (DMMP) as a marker of total water space and phenylphosphonate (PPA) as a marker of extr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910320206

    authors: Clarke K,Anderson RE,Nédélec JF,Foster DO,Ally A

    更新日期:1994-08-01 00:00:00

  • Accelerated 3D T2 mapping with dictionary-based matching for prostate imaging.

    abstract:PURPOSE:To develop a fast and accurate method for 3D T2 mapping of prostate cancer using undersampled acquisition and dictionary-based fitting. METHODS:3D high-resolution T2 -weighted images (0.9 × 0.9 × 3 mm3 ) were obtained with a multishot T2 -prepared balanced steady-state free precession (T2 -prep-bSSFP) acquisit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27540

    authors: Roccia E,Vidya Shankar R,Neji R,Cruz G,Munoz C,Botnar R,Goh V,Prieto C,Dregely I

    更新日期:2019-03-01 00:00:00

  • High-resolution 1H NMR spectroscopy in the diagnosis of breast cancer.

    abstract::Surgical specimens from 22 patients with infiltrating ductal carcinoma of the breast were analyzed by high-resolution 1H NMR spectroscopy at 80 and 300 MHz. Results were compared with those obtained from 9 benign (proliferative dysplasia without atypia) breast samples. NMR spectra at 80 MHz showed well-resolved water ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910080407

    authors: Bradamante S,Barchiesi E,Pilotti S,Borasi G

    更新日期:1988-12-01 00:00:00

  • Cerebral T1rho relaxation time increases immediately upon global ischemia in the rat independently of blood glucose and anoxic depolarization.

    abstract::Time-dependent changes of T1 in the rotating frame (T1rho), diffusion, T2, and magnetization transfer contrast on cardiac arrest-induced global ischemia in rat were investigated. T1rho, as acquired with spin lock amplitudes >0.6 G, started to increase 10-20 sec after cardiac arrest followed by an increase within 3-4 m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1228

    authors: Kettunen MI,Gröhn OH,Penttonen M,Kauppinen RA

    更新日期:2001-09-01 00:00:00

  • Improved myocardial tagging contrast.

    abstract::Myocardial tagging is a new noninvasive MRI method that allows the study of myocardial motion with high accuracy. However, with conventional tagging techniques tagging contrast is impaired at later heart phases due to longitudinal relaxation. An improved method, called Complementary SPAtial Modulation of Magnetization...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300207

    authors: Fischer SE,McKinnon GC,Maier SE,Boesiger P

    更新日期:1993-08-01 00:00:00

  • The effect of realistic geometries on the susceptibility-weighted MR signal in white matter.

    abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26689

    authors: Xu T,Foxley S,Kleinnijenhuis M,Chen WC,Miller KL

    更新日期:2018-01-01 00:00:00

  • A multicontrast imaging method using steady-state free precession with alternating RF flip angles.

    abstract:PURPOSE:To obtain multicontrast images including fat-suppressed contrast image, a novel multicontrast imaging method using an SSFP sequence with alternating RF flip angles is proposed. METHODS:The proposed method uses the balanced SSFP sequence with 2 flip angles. In general, the conventional balanced SSFP sequence ha...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27342

    authors: Kim J,Seo H,So S,Park H

    更新日期:2018-10-01 00:00:00

  • Double average parallel steady-state free precession imaging: optimized eddy current and transient oscillation compensation.

    abstract::Balanced steady-state free precession (SSFP) imaging is sensitive to off-resonance effects, which can lead to considerable artifacts during a transient phase following magnetization preparation or steady-state interruption. In addition, nonlinear k-space encoding is required if contrast-relevant k-space regions need t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20615

    authors: Markl M,Leupold J,Bieri O,Scheffler K,Hennig J

    更新日期:2005-10-01 00:00:00

  • The effect of B1 field inhomogeneity and the nonselective inversion profile on the kinetics of FAIR-based perfusion MRI.

    abstract::Perfusion imaging with pulsed arterial spin labeling techniques, like flow-sensitive alternating inversion recovery (FAIR), may suffer from inflow of fresh, i.e., unlabeled, spins. Inflow of fresh spins is caused by the arrival of unlabeled spins in the image slice and can lead to underestimation of the perfusion if n...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20480

    authors: Schepers J,van Osch MJ,Bartels LW,Heukels SN,Viergever MA,Nicolay K

    更新日期:2005-06-01 00:00:00

  • Carotid-CNS MR flow imaging.

    abstract::The authors present their 1-year experience with the use of 3DFT, time-of-flight MR angiography for the evaluation of vascular diseases of the head and neck. Their experience with over 150 patients indicates that this examination may be performed in conjunction with standard spin-echo imaging with only a minimal incre...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910140215

    authors: Masaryk TJ,Laub GA,Modic MT,Ross JS,Haacke EM

    更新日期:1990-05-01 00:00:00

  • Advantage of sampling density weighted apodization over postacquisition filtering apodization for sodium MRI of the human brain.

    abstract::For sodium imaging of the human brain, Gibbs' ringing can degrade image appearance and confound image analysis; k-space filtering is generally required. In this work, the signal to noise ratio (SNR) advantage of sampling density weighted apodization (SDWA) over uniform k-space sampling with postacquisition filtering a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21738

    authors: Stobbe R,Beaulieu C

    更新日期:2008-10-01 00:00:00

  • Wavelet transform-based Wiener filtering of event-related fMRI data.

    abstract::The advent of event-related functional magnetic resonance imaging (fMRI) has resulted in many exciting studies that have exploited its unique capability. However, the utility of event-related fMRI is still limited by several technical difficulties. One significant limitation in event-related fMRI is the low signal-to-...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200011)44:5<746::aid-mrm13>3.0.c

    authors: LaConte SM,Ngan SC,Hu X

    更新日期:2000-11-01 00:00:00

  • Multi-band MR fingerprinting (MRF) ASL imaging using artificial-neural-network trained with high-fidelity experimental data.

    abstract:PURPOSE:We aim to leverage the power of deep-learning with high-fidelity training data to improve the reliability and processing speed of hemodynamic mapping with MR fingerprinting (MRF) arterial spin labeling (ASL). METHODS:A total of 15 healthy subjects were studied on a 3T MRI. Each subject underwent 10 runs of a m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28560

    authors: Fan H,Su P,Huang J,Liu P,Lu H

    更新日期:2021-04-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI.

    abstract:PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was perform...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25769

    authors: Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FH

    更新日期:2016-06-01 00:00:00

  • Localized double-quantum filter and correlation spectroscopy experiments.

    abstract::Problems with in vivo proton spectroscopy include strong water and lipid signals, and the very complicated structures of the spectra. Multiple-quantum experiments can be designed to overcome these difficulties. Using a volume selective refocusing technique, one can demonstrate how multiple-quantum experiments can be p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060311

    authors: McKinnon GC,Bosiger P

    更新日期:1988-03-01 00:00:00

  • Multi-angle ratiometric approach to measure chemical exchange in amide proton transfer imaging.

    abstract::Amide proton transfer imaging, a specific form of chemical exchange saturation transfer imaging, has previously been applied to studies of acute ischemic acidosis, stroke, and cancer. However, interpreting the resulting contrast is complicated by its dependence on the exchange rate between amides and water, the amide ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23276

    authors: Zu Z,Janve VA,Li K,Does MD,Gore JC,Gochberg DF

    更新日期:2012-09-01 00:00:00