Abstract:
PURPOSE:Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. METHODS:Quantitative perfusion MRI in mice was performed using both methods at rest, with a vasodilator, and one day after myocardial infarction. Image quality (score of 1-5; 5 best), between-session coefficient of variability (CVbs ), intra-user coefficient of variability (CVintra-user ), and inter-user coefficient of variability (CVinter-user ) were assessed. Acquisition time was 1-2 min for first-pass MRI and approximately 40 min for ASL. RESULTS:Image quality was higher for ASL (3.94 ± 0.09 versus 2.88 ± 0.10; P < 0.05). Infarct zone CVbs was lower with first-pass (17 ± 3% versus 46 ± 9%; P < 0.05). The stress perfusion CVintra-user was lower for ASL (3 ± 1% versus 14 ± 3%; P < 0.05). The stress perfusion CVinter-user was lower for ASL (4 ± 1% versus 17 ± 4%; P < 0.05). CONCLUSION:For low MBF conditions such as infarct, first-pass MRI is preferred due to better repeatability and variability. At high MBF such as at vasodilation, ASL may be more suitable due to superior image quality and lower user variability. First-pass MRI has a substantial speed advantage. Magn Reson Med 75:2394-2405, 2016. © 2015 Wiley Periodicals, Inc.
journal_name
Magn Reson Medjournal_title
Magnetic resonance in medicineauthors
Naresh NK,Chen X,Moran E,Tian Y,French BA,Epstein FHdoi
10.1002/mrm.25769subject
Has Abstractpub_date
2016-06-01 00:00:00pages
2394-405issue
6eissn
0740-3194issn
1522-2594journal_volume
75pub_type
杂志文章abstract::In echo-planar-based diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion-sensitizing gradients. Correc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10690
更新日期:2004-01-01 00:00:00
abstract::The diffusional kurtosis is an indicator for diffusion restrictions in biological tissue. It is observed experimentally that the kurtosis is largest for directions perpendicular to the fiber direction in white matter. The directional dependence of the kurtosis can be described by the diffusion kurtosis tensor. Since t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23133
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:To integrate markerless head motion tracking with prospectively corrected neuroanatomical MRI sequences and to investigate high-frequency motion correction during imaging echo trains. METHODS:A commercial 3D surface tracking system, which estimates head motion by registering point cloud reconstructions of the ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.27705
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to develop a three-dimensional black blood imaging method for simultaneously evaluating the carotid and intracranial arterial vessel walls with high spatial resolution and excellent blood suppression with and without contrast enhancement. METHODS:The delay alternating with nutatio...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25785
更新日期:2016-06-01 00:00:00
abstract::Localized 7Li MR point-resolved spectroscopy (PRESS) was developed as a technique to measure lithium (Li) concentration in rat brain in vivo. Localized 7Li spectra could be obtained at 4.7 T in a 0.7-ml voxel in rat brain over the entire therapeutic range of serum Li for humans. Localized 7Li spin-lattice (T1) and spi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20112
更新日期:2004-07-01 00:00:00
abstract::A method for evaluating the sensitivity of MRI protocols to changes in an arbitrary number of tissue parameters over a broad range of parameter values is presented. This analysis is useful for choosing an optimal basis set of images for either a "survey" protocol or tissue segmentation algorithms. A survey protocol is...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910130202
更新日期:1990-02-01 00:00:00
abstract::Intracranial vascular territories are usually visualized with the use of angiographic techniques. However, because it is difficult to visualize the distal vascular bed with any angiographic technique, it is also difficult to infer the parenchymal borders of vascular territories. Arterial spin labeling (ASL) MRI provid...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/mrm.20998
更新日期:2006-09-01 00:00:00
abstract::High-order radiofrequency transmitter coils are described that permit, in the context of NMR imaging, a knowledgeable trade-off between coil complexity and the degree of inhomogeneity over a specified volume of space. A mathematical formulation of high-order coils is developed for an axially symmetric polarizing dc fi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910030108
更新日期:1986-02-01 00:00:00
abstract::Dynamic susceptibility contrast (DSC) MRI is now increasingly used for measuring perfusion in many different applications. The quantification of DSC data requires the measurement of the arterial input function (AIF) and the deconvolution of the tissue concentration time curve. One of the most accepted deconvolution me...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.c
更新日期:2000-09-01 00:00:00
abstract:PURPOSE:To investigate the effect of realistic microstructural geometry on the susceptibility-weighted MR signal in white matter (WM), with application to demyelination. METHODS:Previous work has modeled susceptibility-weighted signals under the assumption that axons are cylindrical. In this study, we explored the imp...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26689
更新日期:2018-01-01 00:00:00
abstract::Ferumoxytol is an ultrasmall superparamagnetic iron oxide agent marketed for the treatment of anemia. There has been increasing interest in its properties as an MRI contrast agent as well as greater awareness of its adverse event profile. This mini-review summarizes the current state of knowledge of the risks of ferum...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章,评审
doi:10.1002/mrm.26151
更新日期:2016-05-01 00:00:00
abstract::This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.20866
更新日期:2006-05-01 00:00:00
abstract:PURPOSE:Spiral readouts combine several favorable properties that promise superior net sensitivity for diffusion imaging. The purpose of this study is to verify the signal-to-noise ratio (SNR) benefit of spiral acquisition in comparison with current echo-planar imaging (EPI) schemes. METHODS:Diffusion-weighted in vivo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28554
更新日期:2021-04-01 00:00:00
abstract::Optimization of experimental settings of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), like the contrast administration protocol, is of great importance for reliable quantification of the microcirculatory properties, such as the volume transfer-constant K(trans). Using system identification theory an...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21575
更新日期:2008-05-01 00:00:00
abstract::A novel method based on selective detection of rapidly changing DeltaB(0) magnetic fields and suppression of slowly changing DeltaB(0) fields is presented. The ultimate goal of this work is to present a method that may allow detection of transient and subtle changes in B(0) in cortical tissue associated with electrica...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.10159
更新日期:2002-06-01 00:00:00
abstract:PURPOSE:To compare experimental transverse relaxivities of iron oxide nanocrystals (IONC) as a function of clustering and magnetic field strength with different theoretical model predictions. THEORY AND METHODS:Well-defined IONC clusters in nanoemulsions (NEs) of which both size and IONC loading could be judiciously t...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25465
更新日期:2015-09-01 00:00:00
abstract::The differential effects of high temperature on 9L rat gliosarcoma cells cultured in two distinctive forms, namely, anchored monolayer cells and multicellular spheroids, were investigated using 31P nuclear magnetic resonance spectroscopy. The critical temperatures resulting in irreversible changes in cellular energeti...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910190233
更新日期:1991-06-01 00:00:00
abstract::When deoxygenated, blood behaves as an effective susceptibility contrast agent. Changes in brain oxygenation can be monitored using gradient-echo echo-planar imaging. With this technique, difference images also demonstrate that blood oxygenation is increased during periods of recovery from respiratory challenge. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910220117
更新日期:1991-11-01 00:00:00
abstract:PURPOSE:To develop a pulsed CEST magnetization-transfer method for rapidly acquiring relayed nuclear Overhauser enhancement (rNOE)-weighted images with magnetic transfer contrast (MTC) suppression at clinical field strength (3 T). METHODS:Using a pulsed CEST magnetization-transfer method with low saturation powers (B1...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28433
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:Evaluate the usefulness of single-shot and of interleaved spatiotemporally encoded (SPEN) methods to perform diffusion tensor imaging (DTI) under various preclinical and clinical settings. METHODS:A formalism for analyzing SPEN DTI data is presented, tailored to account for the spatially dependent b-matrix wei...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26197
更新日期:2017-03-01 00:00:00
abstract:PURPOSE:To develop a fast three-dimensional (3D) k-space encoding method based on spiral projection imaging (SPI) with an interleaved golden-angle approach and to validate this novel sequence on small animal models. METHODS:A disk-like trajectory, in which each disk contained spirals, was developed. The 3D encoding wa...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.26263
更新日期:2017-05-01 00:00:00
abstract::Accurate and fast quantification of myocardial blood flow (MBF) with MR first-pass perfusion imaging techniques on a pixel-by-pixel basis remains difficult due to relatively long calculation times and noise-sensitive algorithms. In this study, Zierler's central volume principle was used to develop an algorithm for the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21559
更新日期:2008-06-01 00:00:00
abstract::In MRI, imaging using receiving coil arrays with a large number of elements is an area of growing interest. With increasing channel numbers for parallel acquisition, longer reconstruction times have become a significant concern. Channel reduction techniques have been proposed to reduce the processing time of channel-b...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23048
更新日期:2012-03-01 00:00:00
abstract::The ability to generate in vivo maps of lactate may have significant diagnostic utility in staging and treatment planning of a wide variety of cancers. The double selective multiple quantum filter technique (SelMQC) has been shown to be effective for nonlocalized detection of lactate with little or no interference fro...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21659
更新日期:2008-08-01 00:00:00
abstract::A comparison between contrast and signal-to-noise ratio (SNR), as obtained by both maximum entropy (ME) and 2DFT reconstruction, is reported for NMR images. Our results show that in the ME elaboration the contrast and SNR are generally increased with respect to the 2DFT elaboration. The magnitude of such an increase d...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.1910080310
更新日期:1988-11-01 00:00:00
abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>
更新日期:1999-04-01 00:00:00
abstract:PURPOSE:To improve ultrahigh field diffusion-weighted imaging (DWI) in the presence of inhomogeneous transmit B1 field by designing a novel semi-adiabatic single-refocused DWI technique. METHODS:A 180° slice-selective, adiabatic radiofrequency (RF) pulse of 4 ms duration was designed using the adiabatic Shinnar-Le Rou...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.25790
更新日期:2016-05-01 00:00:00
abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.21584
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) a...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.28430
更新日期:2021-01-01 00:00:00
abstract::Three-dimensional MRI is typically performed with the same orientation for radiofrequency slab excitation and slab select phase encoding. We introduce independent slab excitation and encoding to create a new degree of freedom in three-dimensional MRI, which is the angular relationship between the prescribed excitation...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/mrm.23043
更新日期:2012-02-01 00:00:00