Carotid-CNS MR flow imaging.

Abstract:

:The authors present their 1-year experience with the use of 3DFT, time-of-flight MR angiography for the evaluation of vascular diseases of the head and neck. Their experience with over 150 patients indicates that this examination may be performed in conjunction with standard spin-echo imaging with only a minimal increase in patient examination time. This combined examination is most applicable to atherosclerotic disease of the carotid bifurcation, arterial occlusions of the primary and secondary branches of the intracranial circulation (particularly in pediatric patients such as those following ECMO or with sickle cell anemia), and patients with saccular berry aneurysms. This type of static, angiographic technique adds little to standard spin-echo imaging in patients with arteriovenous fistulae, neoplasms, and giant intracranial aneurysms. Limitations of the present technique include the inability to visualize slow flow lesions (e.g., giant aneurysms) and selected high flow states (arteriovenous fistulae, some severe stenoses).

journal_name

Magn Reson Med

authors

Masaryk TJ,Laub GA,Modic MT,Ross JS,Haacke EM

doi

10.1002/mrm.1910140215

subject

Has Abstract

pub_date

1990-05-01 00:00:00

pages

308-14

issue

2

eissn

0740-3194

issn

1522-2594

journal_volume

14

pub_type

杂志文章
  • In vivo multiple-mouse MRI at 7 Tesla.

    abstract::We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20683

    authors: Bock NA,Nieman BJ,Bishop JB,Mark Henkelman R

    更新日期:2005-11-01 00:00:00

  • Eddy current correction in diffusion-weighted imaging using pairs of images acquired with opposite diffusion gradient polarity.

    abstract::In echo-planar-based diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusion-sensitizing gradients. Correc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10690

    authors: Bodammer N,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2004-01-01 00:00:00

  • Steady state of echo-shifted sequences with radiofrequency phase cycling.

    abstract::Due to a delayed echo-formation, echo-shifted gradient echo sequences (ES-GRE) allow for an enhanced T(2)*-weighting at short repetition times. While they are in use with and without RF spoiling, analytical solutions are only known for the latter. The signal formation in the former could only be assessed in approximat...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21010

    authors: Ganter C

    更新日期:2006-10-01 00:00:00

  • Uncovering of intracellular water in cultured cells.

    abstract::The complexity of biologic tissues, with multiple compartments each with its own diffusion and relaxation properties, requires complex formalisms to model water signal in most magnetic resonance imaging or magnetic resonance spectroscopy experiments. In this article, we describe a magnetic susceptibility-induced shift...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20565

    authors: Galons JP,Lope-Piedrafita S,Divijak JL,Corum C,Gillies RJ,Trouard TP

    更新日期:2005-07-01 00:00:00

  • Extended ISIS sequences insensitive to T(1) smearing.

    abstract::Image selected in vivo spectroscopy (ISIS) is a volume selection method often used for in vivo (31)P MRS, since it is suitable for measurements of substances with short T(2). However, ISIS can suffer from significant signal contributions caused by T(1) smearing from regions outside the VOI. A computer model was develo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200010)44:4<546::aid-mrm8>3.0.co

    authors: Ljungberg M,Starck G,Vikhoff-Baaz B,Alpsten M,Ekholm S,Forssell-Aronsson E

    更新日期:2000-10-01 00:00:00

  • Identification of different lipid phases and calcium phosphate deposits in human carotid artery plaques by MAS NMR spectroscopy.

    abstract::Accumulation of lipids in atherosclerotic plaques causes progressive narrowing of the arterial lumen, often followed by thrombosis and ischemia. Currently several different methods, most requiring disruption of the plaque, are used to study the physical properties of lipids accumulated in plaques, and lipid compositio...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390204

    authors: Guo W,Morrisett JD,Lawrie GM,DeBakey ME,Hamilton JA

    更新日期:1998-02-01 00:00:00

  • Aortic wall shear stress in Marfan syndrome.

    abstract::The aim of this study was to quantify changes in thoracic aortic wall shear stress (WSS) in asymptomatic patients with Marfan syndrome (MFS) compared with healthy controls. WSS in the thoracic aorta was quantified based on time-resolved 3D phase contrast MRI with three-directional velocity encoding (4D flow MRI, tempo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24562

    authors: Geiger J,Arnold R,Herzer L,Hirtler D,Stankovic Z,Russe M,Langer M,Markl M

    更新日期:2013-10-01 00:00:00

  • The effect of reconstruction and acquisition parameters for GRAPPA-based parallel imaging on the image quality.

    abstract::Parallel imaging based on generalized autocalibrating partially parallel acquisitions is widely used in the clinical routine. To date, no detailed analysis has been presented describing the dependence of the image quality on the reconstruction and acquisition parameters such as the number of autocalibration signal (AC...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22803

    authors: Bauer S,Markl M,Honal M,Jung BA

    更新日期:2011-08-01 00:00:00

  • 1H and (31)P magnetization transfer studies of hindleg muscle in wild-type and creatine kinase-deficient mice.

    abstract::The authors addressed the hypothesis that interactions with creatine kinase (CK) play a role in the off-resonance magnetization transfer (MT) effect of creatine in skeletal muscle. Toward that aim, (1)H MT studies were done on hindleg muscle in wild-type mice and in transgenic mice, lacking cytoplasmic CK and/or mitoc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200005)43:5<657::aid-mrm7>

    authors: Kruiskamp MJ,van Vliet G,Nicolay K

    更新日期:2000-05-01 00:00:00

  • Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    abstract:PURPOSE:To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. METHODS:Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were ima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27177

    authors: Fyrdahl A,Vargas Paris R,Nyrén S,Holst K,Ugander M,Lindholm P,Sigfridsson A

    更新日期:2018-11-01 00:00:00

  • In vivo waveguide elastography: effects of neurodegeneration in patients with amyotrophic lateral sclerosis.

    abstract:PURPOSE:Waveguide elastography (WGE) combines magnetic resonance elastography (MRE), diffusion tensor imaging (DTI), and anisotropic inversions for a determination of the elastic properties of white matter. Previously, the method evaluated the anisotropic elastic properties of the corticospinal tracts (CSTs) of healthy...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25067

    authors: Romano A,Guo J,Prokscha T,Meyer T,Hirsch S,Braun J,Sack I,Scheel M

    更新日期:2014-12-01 00:00:00

  • Identification of signal bias in the variable flip angle method by linear display of the algebraic Ernst equation.

    abstract::A novel linear parameterization for the variable flip angle method for longitudinal relaxation time T(1) quantification from spoiled steady state MRI is derived from the half angle tangent transform, τ, of the flip angle. Plotting the signal S at coordinates x=Sτ and y=S/τ, respectively, establishes a line that render...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22849

    authors: Helms G,Dathe H,Weiskopf N,Dechent P

    更新日期:2011-09-01 00:00:00

  • MR image reconstruction from generalized projections.

    abstract:PURPOSE:Currently, the time required for image reconstruction is prohibitively long if data are acquired using multidimensional imaging trajectories that make use of multichannel systems equipped with nonlinear gradients. Methods are presented that reduce the computational complexity of the iterative time-domain recons...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24928

    authors: Schultz G,Gallichan D,Reisert M,Hennig J,Zaitsev M

    更新日期:2014-08-01 00:00:00

  • T2 accuracy on a whole-body imager.

    abstract::MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380512

    authors: Foltz WD,Stainsby JA,Wright GA

    更新日期:1997-11-01 00:00:00

  • Longitudinal assessment of spinal cord injuries in nonhuman primates with quantitative magnetization transfer.

    abstract:PURPOSE:This study aimed to evaluate the reproducibility and specificity of quantitative magnetization transfer (qMT) imaging for monitoring spinal cord injuries (SCIs). METHODS:MRI scans were performed in anesthetized monkeys at 9.4T, before and serially after a unilateral lesion of the cervical spinal cord. A two-po...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25725

    authors: Wang F,Li K,Mishra A,Gochberg D,Min Chen L,Gore JC

    更新日期:2016-04-01 00:00:00

  • Quantitative and qualitative fat analysis in human leg muscle of neuromuscular diseases by 1H MR spectroscopy in vivo.

    abstract::1H MR spectra were recorded from human gastrocnemius muscle at 63.86 MHz using the body coil of the Signa scanner as transmitter and a 3-in. surface coil as receiver. The fat content of the muscle was quantified relative to that of water in a selected volume or slice. The fat/water ratio was 0.05-0.07 for normal muscl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910100206

    authors: Bárány M,Venkatasubramanian PN,Mok E,Siegel IM,Abraham E,Wycliffe ND,Mafee MF

    更新日期:1989-05-01 00:00:00

  • Complete elimination of the extracellular 23Na NMR signal in triple quantum filtered spectra of rat hearts in the presence of shift reagents.

    abstract::A method is suggested whereby the shifted extracellular triple quantum filtered 23Na signal of an isolated organ is completely eliminated. The method is based on the long relaxation time of the triple quantum coherence and on its fast evolution rate. When the carrier frequency is set on top of the intracellular sodium...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910300415

    authors: Navon G

    更新日期:1993-10-01 00:00:00

  • The use of band-selectable digital filtering in magnetic resonance image enhancement.

    abstract::Manipulation of the data describing two-dimensional magnetic resonance (MR) images can be used to zoom an image, decrease image noise and artifacts by modeling, or emphasize object edges in the field of view. In this paper, a two-dimensional band-selectable digital filtering (2D-BSDF) technique is detailed. This can b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910090307

    authors: Mitchell DK,Nichols ST,Smith MR,Scott K

    更新日期:1989-03-01 00:00:00

  • Evaluation of motion and realignment for functional magnetic resonance imaging in real time.

    abstract::Functional magnetic resonance imaging in real time is an emerging tool for the assessment of dynamic changes in brain activation. The short response latency (tens of seconds) renders the technique more sensitive to motion artifacts. Motion correction in real time requires computationally efficient algorithms which can...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/1522-2594(200101)45:1<167::aid-mrm1023>3.0

    authors: Mathiak K,Posse S

    更新日期:2001-01-01 00:00:00

  • Characterization and correction of center-frequency effects in X-nuclear eddy current compensations on a clinical MR system.

    abstract:PURPOSE:The aim of the study was to investigate whether incorrectly compensated eddy currents are the source of persistent X-nuclear spectroscopy and imaging artifacts, as well as methods to correct this. METHODS:Pulse-acquire spectra were collected for 1 H and X-nuclei (23 Na or 31 P) using the minimum TR permitted o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28607

    authors: McLean MA,Hinks RS,Kaggie JD,Woitek R,Riemer F,Graves MJ,McIntyre DJO,Gallagher FA,Schulte RF

    更新日期:2020-12-04 00:00:00

  • Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

    abstract::Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performe...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400307

    authors: Spielman DM,Adalsteinsson E,Lim KO

    更新日期:1998-09-01 00:00:00

  • Water and fat MR imaging with chemical shift selective 3D steady state methods.

    abstract::A new 3D acquisition regimen that enables the collection of conventional, water-suppressed, and fat-suppressed images with no increase in scan times compared with currently implemented 3D sequences is presented. The method is based on conventional 3D steady state with interleaved selective excitation of the fat resona...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310403

    authors: Sun L,Aletras AH,Schmalbrock P,Skinner TE,Chakeres D,Irsik R,Robitaille PM

    更新日期:1994-04-01 00:00:00

  • Interleaved diffusion-weighted improved by adaptive partial-Fourier and multiband multiplexed sensitivity-encoding reconstruction.

    abstract:PURPOSE:We report a series of techniques to reliably eliminate artifacts in interleaved echo-planar imaging (EPI) based diffusion-weighted imaging (DWI). METHODS:First, we integrate the previously reported multiplexed sensitivity encoding (MUSE) algorithm with a new adaptive Homodyne partial-Fourier reconstruction alg...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25318

    authors: Chang HC,Guhaniyogi S,Chen NK

    更新日期:2015-05-01 00:00:00

  • Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

    abstract::Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21728

    authors: Robson PM,Grant AK,Madhuranthakam AJ,Lattanzi R,Sodickson DK,McKenzie CA

    更新日期:2008-10-01 00:00:00

  • Fully automated patellofemoral MRI segmentation using holistically nested networks: Implications for evaluating patellofemoral osteoarthritis, pain, injury, pathology, and adolescent development.

    abstract:PURPOSE:Our clinical understanding of the relationship between 3D bone morphology and knee osteoarthritis, as well as our ability to investigate potential causative factors of osteoarthritis, has been hampered by the time-intensive nature of manually segmenting bone from MR images. Thus, we aim to develop and validate ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.27920

    authors: Cheng R,Alexandridi NA,Smith RM,Shen A,Gandler W,McCreedy E,McAuliffe MJ,Sheehan FT

    更新日期:2020-01-01 00:00:00

  • Correction of chemical-shift artifacts in 19F imaging of PFOB: a robust signed magnitude method.

    abstract::This paper describes a method for correcting the chemical-shift artifacts in 19F NMR imaging of perfluoroctylbromide emulsion (PFOB) by utilizing the two spectral peaks of PFOB which have a long T2 value in conjunction with the Dixon method. Corrected images are obtained from the magnitude of the measured images using...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910230206

    authors: Lee HK,Nalcioglu O,Buxton RB

    更新日期:1992-02-01 00:00:00

  • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.

    abstract::For perfusion-based functional magnetic resonance imaging, the previously introduced flow-sensitive alternating inversion recovery (FAIR) technique is combined with single-shot RARE (rapid acquisition with relaxation enhancement) and GRASE (gradient and spin echo) imaging sequences. The advantages of these sequences c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199901)41:1<132::aid-mrm18

    authors: Crelier GR,Hoge RD,Munger P,Pike GB

    更新日期:1999-01-01 00:00:00

  • Real-time dynamic frequency and shim correction for single-voxel magnetic resonance spectroscopy.

    abstract::Subject motion during brain magnetic resonance spectroscopy acquisitions generally reduces the magnetic field (B₀) homogeneity across the volume of interest or voxel. This is the case even if prospective motion correction ensures that the voxel follows the head. We introduce a novel method for rapidly mapping linear v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24129

    authors: Keating B,Ernst T

    更新日期:2012-11-01 00:00:00

  • Pattern recognition of MRSI data shows regions of glioma growth that agree with DTI markers of brain tumor infiltration.

    abstract::Gliomas are the most common primary brain tumors and the majority are highly malignant, with one of the worst prognoses for patients. Gliomas are characterized by invasive growth into normal brain tissue that makes complete surgical resection and accurate radiotherapy planning extremely difficult. We have performed in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22163

    authors: Wright AJ,Fellows G,Byrnes TJ,Opstad KS,McIntyre DJ,Griffiths JR,Bell BA,Clark CA,Barrick TR,Howe FA

    更新日期:2009-12-01 00:00:00

  • Water in tendon: orientational analysis of the free induction decay.

    abstract::The orientation dependence of the free induction decay (FID) of 1H NMR water signal in ex vivo bovine digital flexor tendon at the native level of hydration is reported. Residual dipolar coupling due to the overall tissue anisotropy produces a 6:1 change in the signal intensity as an angle between the long axis of a s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20540

    authors: Krasnosselskaia LV,Fullerton GD,Dodd SJ,Cameron IL

    更新日期:2005-08-01 00:00:00