Water and fat MR imaging with chemical shift selective 3D steady state methods.

Abstract:

:A new 3D acquisition regimen that enables the collection of conventional, water-suppressed, and fat-suppressed images with no increase in scan times compared with currently implemented 3D sequences is presented. The method is based on conventional 3D steady state with interleaved selective excitation of the fat resonance resulting in acquisition of a fat-based image during the TR period experienced by the water spins. This new sequence is relatively tolerant to susceptibility artifacts and results in excellent water-based images. Because the idea, which we propose, is independent of the type of steady-state imaging protocol utilized, it can be easily applied with regimens that are specifically tailored to enhance contrast.

journal_name

Magn Reson Med

authors

Sun L,Aletras AH,Schmalbrock P,Skinner TE,Chakeres D,Irsik R,Robitaille PM

doi

10.1002/mrm.1910310403

subject

Has Abstract

pub_date

1994-04-01 00:00:00

pages

359-64

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

31

pub_type

杂志文章
  • Sodium NMR imaging of lung water in rats.

    abstract::Coronal proton and sodium images of control rats and rats with either increased permeability edema produced by intravenous alloxan (300 mg/kg) or increased pressure edema produced by saline infusion (2 ml/min) were obtained. Axial chest CT images were used to monitor the development of pulmonary edema. Immediately aft...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060403

    authors: Kundel HL,Shetty A,Joseph PM,Summers RM,Kassab EA,Moore B

    更新日期:1988-04-01 00:00:00

  • x-f Choice: reconstruction of undersampled dynamic MRI by data-driven alias rejection applied to contrast-enhanced angiography.

    abstract::A technique for reconstructing dynamic undersampled MRI data, termed "x-f choice," was developed and applied to dynamic contrast-enhanced MR angiography (DCE-MRA). Regular undersampling in k-t space (a hybrid of k-space and time) creates aliasing in the conjugate x-f space that must be resolved. When regions in the ob...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21008

    authors: Malik SJ,Schmitz S,O'Regan D,Larkman DJ,Hajnal JV

    更新日期:2006-10-01 00:00:00

  • Ischemia-induced ADC changes are larger than osmotically-induced ADC changes in a neonatal rat hippocampus model.

    abstract::Diffusion-weighted imaging (DWI) is frequently used to diagnose stroke. However, the origin of the observed reduction in the apparent diffusion coefficient (ADC) in the acute phase following ischemia is not well understood. Although cell swelling is considered to play an important role, it is unclear whether this can ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20353

    authors: van Pul C,Jennekens W,Nicolay K,Kopinga K,Wijn PF

    更新日期:2005-02-01 00:00:00

  • MR imaging with hyperpolarized 3He gas.

    abstract::Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system off...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330219

    authors: Middleton H,Black RD,Saam B,Cates GD,Cofer GP,Guenther R,Happer W,Hedlund LW,Johnson GA,Juvan K

    更新日期:1995-02-01 00:00:00

  • Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI.

    abstract::The analysis of abdominal and thoracic dynamic contrast-enhanced MRI is often impaired by artifacts and misregistration caused by physiological motion. Breath-hold is too short to cover long acquisitions. A novel multipurpose reconstruction technique, entitled dynamic contrast-enhanced generalized reconstruction by in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22644

    authors: Filipovic M,Vuissoz PA,Codreanu A,Claudon M,Felblinger J

    更新日期:2011-03-01 00:00:00

  • Cerebral glucose is detectable by localized proton NMR spectroscopy in normal rat brain in vivo.

    abstract::This contribution reports the first direct and noninvasive observation of cerebral glucose in normal anesthetized rats (n = 16) using short-echo-time localized proton NMR spectroscopy (2.35 T, STEAM, TR = 6000 ms, TE = 20 ms, 125 microliters). In addition to resonances from N-acetyl aspartate (NAA), glutamate, total c...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910190243

    authors: Gyngell ML,Michaelis T,Hörstermann D,Bruhn H,Hänicke W,Merboldt KD,Frahm J

    更新日期:1991-06-01 00:00:00

  • Single-breath clinical imaging of hyperpolarized (129)Xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1-point Dixon acquisition.

    abstract:PURPOSE:We sought to develop and test a clinically feasible 1-point Dixon, three-dimensional (3D) radial acquisition strategy to create isotropic 3D MR images of (129)Xe in the airspaces, barrier, and red blood cells (RBCs) in a single breath. The approach was evaluated in healthy volunteers and subjects with idiopathi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25675

    authors: Kaushik SS,Robertson SH,Freeman MS,He M,Kelly KT,Roos JE,Rackley CR,Foster WM,McAdams HP,Driehuys B

    更新日期:2016-04-01 00:00:00

  • Highly accelerated submillimeter resolution 3D GRASE with controlled T 2 blurring in T 2 -weighted functional MRI at 7 Tesla: A feasibility study.

    abstract:PURPOSE:To achieve highly accelerated submillimeter resolution T 2 -weighted functional MRI at 7T by developing a three-dimensional gradient and spin echo imaging (GRASE) with inner-volume sel...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28589

    authors: Park S,Torrisi S,Townsend JD,Beckett A,Feinberg DA

    更新日期:2020-11-24 00:00:00

  • Adaptive self-calibrating iterative GRAPPA reconstruction.

    abstract::Parallel magnetic resonance imaging in k-space such as generalized auto-calibrating partially parallel acquisition exploits spatial correlation among neighboring signals over multiple coils in calibration to estimate missing signals in reconstruction. It is often challenging to achieve accurate calibration information...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.23188

    authors: Park S,Park J

    更新日期:2012-06-01 00:00:00

  • In vivo measurement of T2 distributions and water contents in normal human brain.

    abstract::Using a 32-echo imaging pulse sequence, T2 relaxation decay curves were acquired from five white- and six gray-matter brain structures outlined in 12 normal volunteers. The water contents of white and gray matter were 0.71 (0.01) and 0.83 (0.03) g/ml, respectively. All white-matter structures had significantly higher ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370107

    authors: Whittall KP,MacKay AL,Graeb DA,Nugent RA,Li DK,Paty DW

    更新日期:1997-01-01 00:00:00

  • Multivendor implementation and comparison of volumetric whole-brain echo-planar MR spectroscopic imaging.

    abstract:PURPOSE:To assess volumetric proton MR spectroscopic imaging (MRSI) of the human brain on multivendor MRI instruments. METHODS:Echo-planar spectroscopic imaging was developed on instruments from three manufacturers, with matched specifications and acquisition protocols that accounted for differences in sampling perfor...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25510

    authors: Sabati M,Sheriff S,Gu M,Wei J,Zhu H,Barker PB,Spielman DM,Alger JR,Maudsley AA

    更新日期:2015-11-01 00:00:00

  • Potassium transport in Langendorff-perfused mouse hearts assessed by 87Rb NMR spectroscopy.

    abstract::We studied the fluxes of a potassium congener (Rb(+)) in mouse hearts by (87)Rb MRS at 8.4T. The hearts were loaded with Rb(+) by perfusion with Krebs-Henseleit buffer, in which 50% of K(+) was substituted with Rb(+). We initiated Rb(+) efflux by changing the perfusion medium to Rb(+)-free buffer. Spectra were acquire...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20450

    authors: Jilkina O,Xiang B,Kuzio B,Rendell J,Kupriyanov VV

    更新日期:2005-05-01 00:00:00

  • Evaluation of hepatic steatosis before liver transplantation in ex vivo by volumetric quantitative PDFF-MRI.

    abstract:PURPOSE:Over the last two decades, extended criteria have promoted an increased number of donor livers available for liver transplantation. But posttransplant graft loss is still a major concern. Macrovesicular hepatic steatosis (MHS) is recognized as the most significant prognostic histologic parameter in predicting p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28592

    authors: Chen G,Jiang J,Wang X,Yang M,Xie Y,Guo H,Tang H,Zhou L,Hu D,Kamel IR,Chen Z,Li Z

    更新日期:2020-11-16 00:00:00

  • The effect of reducing repetition time TR on the measurement of liver R2 for the purpose of measuring liver iron concentration.

    abstract::The effects of reducing the pulse repetition time from 2500 ms to 1000 ms when using spin-density-projection-assisted R2-magnetic resonance imaging for the purpose of measuring liver iron concentration were evaluated. Repeated liver R2 measurements were made using both protocols on 60 subjects with liver iron concentr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22712

    authors: Pavitt HL,Aydinok Y,El-Beshlawy A,Bayraktaroglu S,Ibrahim AS,Hamdy MM,Pang W,Sharples C,St Pierre TG

    更新日期:2011-05-01 00:00:00

  • Regularized higher-order in vivo shimming.

    abstract::A regularized algorithm is presented for localized in vivo shimming. The technique uses first- (X,Y,Z), second- (Z(2), ZX, ZY, X(2)-Y(2), XY), and third-order (Z(3)) shim coils, and is robust when applied to arbitrarily-shaped, as well as off-center, regions of interest (ROIs). A single-shot spiral pulse sequence is u...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10267

    authors: Kim DH,Adalsteinsson E,Glover GH,Spielman DM

    更新日期:2002-10-01 00:00:00

  • Fast diffusion tensor imaging and tractography of the whole cervical spinal cord using point spread function corrected echo planar imaging.

    abstract::Diffusion tensor imaging has been used in a number of spinal cord studies, but severe distortions caused by susceptibility induced field inhomogeneities limit its applicability to investigate small volumes within acceptable acquisition times. A way to evaluate image distortions is to map the point spread function of t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24235

    authors: Lundell H,Barthelemy D,Biering-Sørensen F,Cohen-Adad J,Nielsen JB,Dyrby TB

    更新日期:2013-01-01 00:00:00

  • Work-related factors associated with occupational exposure to static magnetic stray fields from MRI scanners.

    abstract:PURPOSE:This study aims to identify work-related and personal factors associated with workers' exposure to static magnetic fields (SMF) and motion-induced time-varying magnetic fields (TVMF) from MRI scanners. METHODS:Measurements of personal exposure to SMF and TVMF were performed among MRI staff during 439 work shif...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25720

    authors: Schaap K,Christopher-De Vries Y,Cambron-Goulet É,Kromhout H

    更新日期:2016-05-01 00:00:00

  • The impact of the relaxivity definition on the quantitative measurement of glycosaminoglycans in cartilage by the MRI dGEMRIC method.

    abstract::The relaxivities (R-values) of the gadolinium diethylene triamine pentaacetic acid (Gd(DTPA)2-) ions in a series of skim-milk solutions at 0-40% milk concentrations were measured using NMR spectroscopy. The R-value was found to be approximately linearly proportional to the concentration of the solid component in the m...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22169

    authors: Zheng S,Xia Y

    更新日期:2010-01-01 00:00:00

  • Total brain N-acetylaspartate concentration in normal, age-grouped females: quantitation with non-echo proton NMR spectroscopy.

    abstract::The intra-individual and inter-individual variations of the global N-acetylaspartate (NAA) concentration were measured in a cohort of five 42+/-5 year-old normal females. The total NAA signal from the whole head was obtained with non-localized non-echo proton spectroscopy (1H-MRS) and converted into absolute mole amou...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/mrm.1910400506

    authors: Gonen O,Viswanathan AK,Catalaa I,Babb J,Udupa J,Grossman RI

    更新日期:1998-11-01 00:00:00

  • Reduction of B1 sensitivity in selective single-slab 3D turbo spin echo imaging with very long echo trains.

    abstract::Single-slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is vulnerable to image degradation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22070

    authors: Park J,Mugler JP 3rd,Hughes T

    更新日期:2009-10-01 00:00:00

  • Vascular transit times in calcarine cortex: kinetic analysis of R2* changes observed using localized 1H spectroscopy.

    abstract::A kinetic analysis of water signal intensity changes measured in human visual cortex by PRESS localized 1H spectroscopy at 500 ms resolution with light-emitting diode (LED) goggle stimulation was used to determine vascular transit times for transitions between rest and activation. Monoexponential curve fitting was use...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340308

    authors: Detre JA,Wang Z,Stecker MM,Zimmerman RA

    更新日期:1995-09-01 00:00:00

  • Phosphonate-modified GdDTPA complexes. I. NMRD study of the solution behavior of new tissue-specific contrast agents.

    abstract::NMRD profiles, the magnetic field dependence of the water proton longitudinal relaxation rates, have been acquired for two new diphosphonate-modified GdDTPA complexes currently under evaluation as relaxation agents for the MRI detection of soft-tissue calcifications. Fresh dilute solutions show profiles identical to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170118

    authors: Adzamli IK,Blau M

    更新日期:1991-01-01 00:00:00

  • Dynamic 13C NMR analysis of pyruvate and lactate oxidation in the in vivo canine myocardium: evidence of reduced utilization with increased work.

    abstract::In this work, substrate selection was monitored in the left ventricle of the canine myocardium by following pyruvate and lactate oxidation under in vivo conditions at basal and elevated workloads. These studies were conducted in the open chest model using dynamic 13C NMR techniques in the presence and absence of dichl...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380608

    authors: Rath DP,Zhu H,Tong X,Jiang Z,Hamlin RL,Robitaille PM

    更新日期:1997-12-01 00:00:00

  • Local planar gradients with order-of-magnitude strength and speed advantage.

    abstract::A three-axis uniplanar gradient coil was designed and built to provide order-of-magnitude increases in gradient strength of up to 500 mT/m on the x- and y-axes, and 1000 mT/m for the z-axis at 640 A input over a limited FOV ( approximately 16 cm) for superficial regions, compared to conventional gradient coils, with s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21263

    authors: Aksel B,Marinelli L,Collick BD,Von Morze C,Bottomley PA,Hardy CJ

    更新日期:2007-07-01 00:00:00

  • Rapid T2 estimation with phase-cycled variable nutation steady-state free precession.

    abstract::Variable nutation SSFP (DESPOT2) permits rapid, high-resolution determination of the transverse (T2) relaxation constant. A limitation of DESPOT2, however, is the presence of T2 voids due to off-resonance banding artifacts associated with SSFP images. These artifacts typically occur in images acquired with long repeti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20159

    authors: Deoni SC,Ward HA,Peters TM,Rutt BK

    更新日期:2004-08-01 00:00:00

  • Data-driven optimized flip angle selection for T1 estimation from spoiled gradient echo acquisitions.

    abstract:PURPOSE:Define criteria for selection of optimal flip angle sets for T1 estimation and evaluate effects on T1 mapping. THEORY AND METHODS:Flip angle sets for spoiled gradient echo-based T1 mapping were selected by minimizing T1 estimate variance weighted by the joint density of M0 and T1 in an initial acquisition. The...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25920

    authors: Lewis CM,Hurley SA,Meyerand ME,Koay CG

    更新日期:2016-09-01 00:00:00

  • Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

    abstract::A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The dec...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21095

    authors: Gabr RE,Aksit P,Bottomley PA,Youssef AB,Kadah YM

    更新日期:2006-12-01 00:00:00

  • Study of the effect of CSF suppression on white matter diffusion anisotropy mapping of healthy human brain.

    abstract::Healthy human brain diffusion anisotropy maps derived from standard spin echo diffusion tensor imaging (DTI) were compared with those using fluid-attenuated inversion recovery (FLAIR) preparation prior to DTI to null the signal from cerebrospinal fluid (CSF). Consistent comparisons entailed development of DTI postproc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10204

    authors: Papadakis NG,Martin KM,Mustafa MH,Wilkinson ID,Griffiths PD,Huang CL,Woodruff PW

    更新日期:2002-08-01 00:00:00

  • On consideration of radiated power in RF field simulations for MRI.

    abstract::In numerical analyses of radiofrequency (RF) fields for MRI, RF power is often permitted to radiate out of the problem region. In reality, RF power will be confined by the magnet bore and RF screen enclosing the magnet room. We present numerical calculations at different frequencies for various surface and volume coil...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24244

    authors: Liu W,Kao CP,Collins CM,Smith MB,Yang QX

    更新日期:2013-01-01 00:00:00

  • Enhancement of respiratory navigator-gated three-dimensional spoiled gradient-recalled echo sequence with variable flip angle scheme.

    abstract:PURPOSE:To develop and demonstrate the feasibility of a new technique for respiratory-gated, fat-suppressed, three-dimensional spoiled gradient-recalled echo (3D-SPGR) with navigator gating for more accurate and robust motion detection. METHODS:A navigator-gated 3D-SPGR technique was modified to include a wait period ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24902

    authors: Iwadate Y,Brau AC,Vasanawala SS,Kabasawa H

    更新日期:2014-07-01 00:00:00